Investigation of Electromagnetic Gauges for Determining In-Place HMA Density, 2007
Data(s) |
2007
|
---|---|
Resumo |
Density is an important component of hot-mix asphalt (HMA) pavement quality and long-term performance. Insufficient density of an in-place HMA pavement is the most frequently cited construction-related performance problem. This study evaluated the use of electromagnetic gauges to nondestructively determine densities. Field and laboratory measurements were taken with two electromagnetic gauges—a PaveTracker and a Pavement Quality Indicator (PQI). Test data were collected in the field during and after paving operations and also in a laboratory on field mixes compacted in the lab. This study revealed that several mix- and project-specific factors affect electromagnetic gauge readings. Consequently, the implementation of these gauges will likely need to be done utilizing a test strip on a project- and mix-specific basis to appropriately identify an adjustment factor for the specific electromagnetic gauge being used for quality control and quality assurance (QC/QA) testing. The substantial reduction in testing time that results from employing electromagnetic gauges rather than coring makes it possible for more readings to be used in the QC/QA process with real-time information without increasing the testing costs. |
Formato |
application/pdf |
Identificador |
http://publications.iowa.gov/5288/1/tr547.pdf (2007) Investigation of Electromagnetic Gauges for Determining In-Place HMA Density, 2007. Iowa State University |
Idioma(s) |
en |
Relação |
http://publications.iowa.gov/5288/ |
Palavras-Chave | #Design and Construction #Concrete |
Tipo |
Departmental Report NonPeerReviewed |