175 resultados para Permanganate-periodate


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oxidation of selected clinically important neurotransmitter metabolites with acidic potassium permanganate in the presence of polyphosphates evokes chemiluminescence of sufficient intensity to enable the sensitive determination of these species. Limits of detection for 5-hydroxyindole-3-acetic acid (5-HIAA), vanilmandelic acid (VMA; α,4-dihydroxy-3-methoxybenzeneacetic acid), 4-hydroxy-3-methoxyphenylglycol (MHPG), homovanillic acid (HVA, 4-hydroxy-3-methoxyphenylacetic acid) and 3,4-dihydroxyphenylacetic acid (DOPAC) were between 5 × 10−9 and 4 × 10−8 M, using flow-injection analysis methodology. In addition, we demonstrate the rapid determination of homovanillic acid and 5-hydroxyindole-3-acetic acid in human urine – without the need for extraction procedures – using monolithic column chromatography with chemiluminescence detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid method for screening drug seizure samples for 3,6-diacetylmorphine (heroin), which consists of a simple hydrolysis procedure and flow-injection analysis with two chemiluminescence reagents, is described. Before hydrolysis, 3,6-diacetylmorphine evokes an intense response with a tris(2,2'-bipyridyl)ruthenium(III) reagent (prepared by dissolving the perchlorate salt in acetonitrile), and a relatively weak chemiluminescence response with a second reagent: potassium permanganate in an aqueous acidic polyphosphate solution. However, the permanganate reagent is extremely sensitive toward the hydrolysis products of 3,6-diacetylmorphine (i.e., 6-monoacetylmorphine and morphine). Some compounds commonly found in drug laboratories may cause false positives with tris(2,2'-bipyridyl)ruthenium(III), but do not produce the markedly increased response with the permanganate reagent after the hydrolysis procedure. The combination of these two tests therefore provides an effective presumptive test for the presence of 3,6-diacetylmorphine, which we have verified with 14 samples obtained from a forensic science laboratory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selective determination of morphine in the larvae of Calliphora stygia (Fabricius) (Diptera: Calliphoridae) using acidic potassium permanganate chemiluminescence detection coupled with flow injection analysis and high-performance liquid chromatography (HPLC) is described. Larvae of C. stygia were reared on minced meat substrates that had been spiked with varying concentrations of morphine. Morphine concentrations were chosen to reflect typical levels in human tissues from opiate overdose victims. After maturing on substrates, larvae were analyzed for the presence of morphine using chemiluminescence detection coupled to flow injection analysis and a rapid HPLC method. Analysis of the larval matrix by flow injection analysis with chemiluminescence detection indicated the presence of interferants capable of generating chemiluminescence. A rapid chromatographic separation with a monolithic column allowed selective determination of morphine in larvae using postcolumn chemiluminescence detection. Larvae of C. stygia reared on substrates containing morphine at concentrations of 500 and 1000 ng/g did not sequester morphine at detectable concentrations. Larvae reared on substrates containing morphine concentrations of 2500, 5000, and 10,000 ng/g tested positive for the drug at concentrations of 765, 2720, and 3010 ng/g, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2′-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids – morphine, codeine, oripavine and thebaine – were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 × 10−10 M, 5 × 10−10 M, 5 × 10−10 M and 1 × 10−9 M, for morphine, codeine, oripavine and thebaine, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the results of our investigations into the use of soluble manganese(IV) as a chemiluminescence reagent, which include a significantly faster method of preparation and a study on the effect of formaldehyde and orthophosphoric acid concentration on signal intensity. Chemiluminescence detection was applied to the determination of 16 analytes, including opiate alkaloids, indoles and analytes of forensic interest, using flow injection analysis methodology. The soluble manganese(IV) reagent was less selective than either acidic potassium permanganate or tris(2,2′-bipyridyl)ruthenium(III) and therefore provided a more universal chemiluminescence detection system for HPLC. A broad spectral distribution with a maximum at 730 ± 5 nm was observed for the reaction between the soluble manganese(IV) and a range of analytes, as well as the background emission from the reaction with the formaldehyde enhancer. This spectral distribution matches that reported for chemiluminescence reactions with acidic potassium permanganate, where a manganese(II) emitting species was elucidated. This provides further evidence that the emission evoked in reactions with soluble manganese(IV) also emanates from a manganese(II) species, and not bimolecular singlet oxygen as suggested by previous authors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2′-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An investigation into the chemiluminescence of fourteen organic acids and tris(2,2′-bipyridyl)ruthenium(II) was undertaken. Particular emphasis was placed upon the method of production of the reagent, tris(2,2′-bipyridyl)ruthenium(III), with cerium(IV) sulfate, potassium permanganate, lead dioxide and electrochemical generation. Analytically useful chemiluminescence was observed when Ce(IV) or potassium permanganate were employed as oxidants. The kinetics of analyte oxidation was related to the intensity of the chemiluminescence emission, which increased by three orders of magnitude for tartaric acid after 40 h of oxidation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel chemiluminescence flow injection procedure for the determination of As(III) in aqueous samples is described. The method involves injection of As(III) samples into a 1% (m/v) sodium hexametaphosphate in 0.02 M H2SO4 carrier stream, which then merges at a Y-piece with a reagent stream consisting of potassium permanganate (5.0 × 10−5 M) made up in the acidic sodium hexametaphosphate carrier solution. The chemiluminescence intensity of the resulting reaction mixture was measured at a photomultiplier tube operated at a voltage of 0.93 kV. Under optimized conditions, the method is characterised by a linear range from 0.5 to 5.0 μg l−1, a detection limit of 0.3 μg l−1 and a sampling frequency of 150 h−1. The effects of common anionic and cationic interferences were investigated, and it was found that the only ions to cause serious interference were those which react with potassium permanganate, namely sulphide, iodide and ferrous.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Article Outline
• Introduction
• Acidic Potassium Permanganate
• Acridinium Esters
• Diaryl Oxalates and Oxamides
• Dioxetanes
• Hypohalites
• Luminol and Its Analogs
• Tris(2,2′-bipyridyl)ruthenium(II)
• Practical Considerations
• HPLC and Flow Analysis
• Capillary Electrophoresis
• Enzyme Reaction Products
• Immunoassay and DNA Assays
• Further Reading


Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is neither comprehensive nor appropriate that the bioremediation of a benzo[a]pyrene (BaP)-contaminated environment be assessed only by its high degradation extent because its metabolites' chemical structures are similar to the parent compound and maybe equally toxic. Therefore, further degradation of BaP metabolites is significant. Three methods, combining the Zoogloea sp. with potassium permanganate, combining the Zoogloea sp. with H2O2, Zoogloea sp. alone, were investigated to degrade cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol, which are the metabolites of BaP formed by bacterium-Zoogloea sp. Optimum parameters of degradation in the best method are that: of the three methods, coupling the Zoogloea sp. and KMnO4 is the best; compared with cis-BP7,8-dihydrodiol, cis-BP4,5-dihydrodiol is the more liable to be accumulated in pure cultures; the degradation effect of the two metabolites is optimal when the initial concentration of KMnO4 in the cultures is 0.05%; initial concentration of cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol is 4 mg L−1, 8 mg L−1, respectively; cometabolic substance is salicylic acid or sodium succinate. The degradation extent of cis-BP4,5-dihydrodiol and cis-BP7,8-dihydrodiol using combining the Zoogloea sp. and KMnO4 reach 76.1% and 85.9% after 12 days of cultivation, respectively, which were more than twice compared with conventional method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sequential injection analysis procedure with dual-reagent chemiluminescence detection was applied to the screening of street drug seizure samples for the presence of heroin. The chemiluminescence reagents (acidic potassium permanganate and tris(2,2′-bipyridine)ruthenium(III)) were aspirated from either side of a sample aliquot that was sufficiently large to prevent interdispersion of the reagent zones, and therefore two different chemical reactions could be performed simultaneously at either end of the sample zone. The presence of heroin in seizure samples was indicated by a strong response with the tris(2,2′-bipyridine)ruthenium(III) reagent and confirmed by a significant increase in the response with the permanganate reagent when the sample was treated with sodium hydroxide to hydrolyse the heroin to morphine. Nicomorphine (a morphine-derived pharmaceutical) was synthesised and tested under the same conditions. The responses with the permanganate reagent were similar to those for heroin, which supports the proposed chemical basis for the test. However, the responses with tris(2,2′-bipyridine)ruthenium(III) were far lower for nicomorphine than heroin (approximately 5-fold for the samples that had not been hydrolysed).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A review with 98 references. The determination of the opium poppy (Papaver somniferum) alkaloids and their semi-synthetic derivatives has important applications in industrial process monitoring, clinical analysis and forensic science. Liquid-phase chemiluminescence reagents such as tris(2,2′-bipyridyl)ruthenium(II) and acidic potassium permanganate exhibit remarkable sensitivity and complementary selectivity for many P. somniferum alkaloids, which has been exploited in the development of a range of analytical procedures using flow analysis, high-performance liquid chromatography, capillary electrophoresis and microfluidic instrumentation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although potassium permanganate [Mn(VII)] has been used extensively as a chemiluminescence reagent for many decades, other manganese-based oxidants have only recently been explored for this purpose. There is strong evidence to suggest that, like permanganate, manganese(III) and manganese(IV) oxidants react with many molecules to produce an excited manganese(II) species that emits light. However, these reagents differ markedly in terms of selectivity, and possess characteristics that provide new avenues for detection, such as the immobilisation of solid manganese dioxide, the production of ‘soluble’ manganese(IV) nanoparticles, and the electrochemical generation of manganese(III). In this review we examine the emergence of these alternative manganese oxidants as chemiluminescence reagents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a new chemiluminescence detector, with solution channels that have been machined into a Teflon disk and sealed with a sapphire window. The configuration of the flow cell can be conveniently modified by replacing the Teflon disk. A comparison of some existing and novel designs, using the chemiluminescence reaction of morphine with acidic potassium permanganate and the bioluminescence reaction of ATP with the commercially available “BacTiter-Glo” reagent, has revealed that a serpentine channel allows greater quantities of light to be captured than a spiral channel, due to more efficient mixing of the analyte and reagent solutions within the cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The health benefits of antioxidant-rich ‘Mediterranean’ type diets high in grain, olives and red wine are well recognised. Since these foodstuffs consist of a complex matrix of chemical components, to date, the primary challenge lies in prioritising and isolating molecules for a physiologically relevant cell culture assay to assess their human health benefits. Currently, the most common approach requires arduous sample fractionation into smaller ‘crude’ extracts, followed by costly cell culture assays, with the bioactive identified only after a positive response in the cell. The work presented within this poster demonstrates the potential for an acidified potassium permanganate chemiluminescence detector as a much simpler screening tool to identify the best bioactive candidates from a complex sample matrix.