734 resultados para Monochromatic Aberrations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Ewing sarcoma family of tumors (ESFT) are rare but highly malignant neoplasms that occur mainly in bone or but also in soft tissue. ESFT affects patients typically in their second decade of life, whereby children and adolescents bear the heaviest incidence burden. Despite recent advances in the clinical management of ESFT patients, their prognosis and survival are still disappointingly poor, especially in cases with metastasis. No targeted therapy for ESFT patients is currently available. Moreover, based merely on current clinical and biological characteristics, accurate classification of ESFT patients often fails at the time of diagnosis. Therefore, there is a constant need for novel molecular biomarkers to be applied in tandem with conventional parameters to further intensify ESFT risk-stratification and treatment selection, and ultimately to develop novel targeted therapies. In this context, a greater understanding of the genetics and immune characteristics of ESFT is needed. Aims: This study sought to open novel insights into gene copy number changes and gene expression in ESFT and, further, to enlighten the role of inflammation in ESFT. For this purpose, microarrays were used to provide gene-level information on a genomewide scale. In addition, this study focused on screening of 9p21.3 deletion sizes and frequencies in ESFT and, in another pediatric cancer, acute lymphocytic leukemia (ALL), in order to define more exact criteria for highrisk patient selection and to provide data for developing a more reliable diagnostic method to detect CDKN2A deletions. Results: In study I, 20 novel ESFT-associated suppressor genes and oncogenes were pinpointed using combined array CGH and expression analysis. In addition, interesting chromosomal rearrangements were identified: (1) Duplication of derivative chromosome der(22)(11;22) was detected in three ESFT patients. This duplication included the EWSR1-FLI1 fusion gene leading to increase in its copy number; (2) Cryptic amplifications on chromosomes 20 and 22 were detected, suggesting a novel translocation between chromosomes 20 and 22, which most probably produces a fusion between EWSR1 and NFATC2. In study II, bioinformatic analysis of ESFT expression profiles showed that inflammatory gene activation is detectable in ESFT patient samples and that the activation is characterized by macrophage gene expression. Most interestingly, ESFT patient samples were shown to express certain inflammatory genes that were prognostically significant. High local expression of C5 and JAK1 at the tumor site was shown to associate with favorable clinical outcome, whereas high local expression of IL8 was shown to be detrimental. Studies III and IV showed that the smallest overlapping region of deletion in 9p21.3 includes CDKN2A in all cases and that the length of this region is 12.2 kb in both Ewing sarcoma and ALL. Furthermore, our results showed that the most widely used commercial CDKN2A FISH probe creates false negative results in the narrowest microdeletion cases (<190 kb). Therefore, more accurate methods should be developed for the detection of deletions in the CDKN2A locus. Conclusions: This study provides novel insights into the genetic changes involved in the biology of ESFT, in the interaction between ESFT cells and immune system, and in the inactivation of CDKN2A. Novel ESFT biomarker genes identified in this study serve as a useful resource for future studies and in developing novel therapeutic strategies to improve the survival of patients with ESFT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Straylight, lens yellowing and ocular aberrations were assessed in a group of people with type 1 diabetes and in an age matched control group. Most of the former had low levels of neuropathy. Relative to the control group, the type 1 diabetes group demonstrated greater straylight, greater lens yellowing, and differences in some higher-order aberration co-efficients without significant increase in root-mean-square higher-order aberrations. Differences between groups did not increase significantly with age. The results are similar to the findings for ocular biometry reported previously for this group of participants, and suggest that age-related changes in the optics of the eyes of people with well-controlled diabetes need not be accelerated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Wavefront-guided Laser-assisted in situ keratomileusis (LASIK) is a widespread and effective surgical treatment for myopia and astigmatic correction but whether it induces higher-order aberrations remains controversial. The study was designed to evaluate the changes in higher-order aberrations after wavefront-guided ablation with IntraLase femtosecond laser in moderate to high astigmatism. Methods Twenty-three eyes of 15 patients with moderate to high astigmatism (mean cylinder, −3.22 ± 0.59 dioptres) aged between 19 and 35 years (mean age, 25.6 ± 4.9 years) were included in this prospective study. Subjects with cylinder ≥ 1.5 and ≤2.75 D were classified as moderate astigmatism while high astigmatism was ≥3.00 D. All patients underwent a femtosecond laser–enabled (150-kHz IntraLase iFS; Abbott Medical Optics Inc) wavefront-guided ablation. Uncorrected (UDVA), corrected (CDVA) distance visual acuity in logMAR, keratometry, central corneal thickness (CCT) and higher-order aberrations (HOAs) over a 6 mm pupil, were assessed before and 6 months, postoperatively. The relationship between postoperative change in HOA and preoperative mean spherical equivalent refraction, mean astigmatism, and postoperative CCT were tested. Results At the last follow-up, the mean UDVA was increased (P < 0.0001) but CDVA remained unchanged (P = 0.48) and no eyes lost ≥2 lines of CDVA. Mean spherical equivalent refraction was reduced (P < 0.0001) and was within ±0.50 D range in 61 % of eyes. The average corneal curvature was flatter by 4 D and CCT was reduced by 83 μm (P < 0.0001, for all), postoperatively. Coma aberrations remained unchanged (P = 0.07) while the change in trefoil (P = 0.047) postoperatively, was not clinically significant. The 4th order HOAs (spherical aberration and secondary astigmatism) and the HOA root mean square (RMS) increased from −0.18 ± 0.07 μm, 0.04 ± 0.03 μm and 0.47 ± 0.11 μm, preoperatively, to 0.33 ± 0.19 μm (P = 0.004), 0.21 ± 0.09 μm (P < 0.0001) and 0.77 ± 0.27 μm (P < 0.0001), six months postoperatively. The change in spherical aberration after the procedure increased with an increase in the degree of preoperative myopia. Conclusions Wavefront-guided IntraLASIK offers a safe and effective option for vision and visual function improvement in astigmatism. Although, reduction of HOA is possible in a few eyes, spherical-like aberrations are increased in majority of the treated eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A deformable mirror (DM) is an important component of an adaptive optics system. It is known that an on-axis spherical/parabolic optical component, placed at an angle to the incident beam introduces defocus as well as astigmatism in the image plane. Although the former can be compensated by changing the focal plane position, the latter cannot be removed by mere optical realignment. Since the DM is to be used to compensate a turbulence-induced curvature term in addition to other aberrations, it is necessary to determine the aberrations induced by such (curved DM surface) an optical element when placed at an angle (other than 0 deg) of incidence in the optical path. To this effect, we estimate to a first order the aberrations introduced by a DM as a function of the incidence angle and deformation of the DM surface. We record images using a simple setup in which the incident beam is reflected by a 37 channel micro-machined membrane deformable mirror for various angles of incidence. It is observed that astigmatism is a dominant aberration, which was determined by measuring the difference between the tangential and sagittal focal planes. We justify our results on the basis of theoretical simulations and discuss the feasibility of using such a system for adaptive optics considering a trade-off between wavefront correction and astigmatism due to deformation. (C) 2015 Optical Society of America

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the feature size decreases, degradation of image quality caused by wavefront aberrations of projection optics in lithographic tools has become a serious problem in the low-k1 process. We propose a novel measurement technique for in situ characterizing aberrations of projection optics in lithographic tools. Considering the impact of the partial coherence illumination, we introduce a novel algorithm that accurately describes the pattern displacement and focus shift induced by aberrations. Employing the algorithm, the measurement condition is extended from three-beam interference to two-, three-, and hybrid-beam interferences. The experiments are performed to measure the aberrations of projection optics in an ArF scanner. (C) 2006 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the extended Huygens-Fresnel principle, the mutual coherence function of quasi-monochromatic electromagnetic Gaussian Schell-model (EGSM) beams propagating through turbulent atmosphere is derived analytically. By employing the lateral and the longitudinal coherence length of EGSM beams to characterize the spatial and the temporal coherence of the beams, the behavior of changes in the spatial and the temporal coherence of those beams is studied. The results show that with a fixed set of beam parameters and under particular atmospheric turbulence model, the lateral coherence of an EGSM beam reaches its maximum value as the beam propagates a certain distance in the turbulent atmosphere, then it begins degrading and keeps decreasing along with the further distance. However, the longitudinal coherence length of an EGSM beam keeps unchanging in this propagation. Lastly, a qualitative explanation is given to these results. (c) 2007 Elsevier B.V. All rights reserved.