983 resultados para Dynamic column separation
Resumo:
In this thesis, equilibrium and dynamic sorption properties of weakly basic chelating adsorbents were studied to explain removal of copper, nickel from a concentrated zinc sulfate solution in a hydrometallurgical process. Silica-supported chelating composites containing either branched poly(ethyleneimine) (BPEI) or 2-(aminomethyl)pyridine (AMP) as a functional group were used. The adsorbents are commercially available from Purity Systems Inc, USA as WP-1® and CuWRAM®, respectively. The fundamental interactions between the adsorbents, sulfuric acid and metal sulfates were studied in detail and the results were used to find the best conditions for removal of copper and nickel from an authentic ZnSO4 process solution. In particular, the effect of acid concentration and temperature on the separation efficiency was considered. Both experimental and modeling aspectswere covered in all cases. Metal sorption is considerably affected by the chemical properties of the studied adsorbents and by the separation conditions. In the case of WP-1, acid affinity is so high that column separation of copper, nickel and zinc has to be done using the adsorbent in base-form. On the other hand, the basicity of CuWRAM is significantly lower and protonated adsorbent can be used. Increasing temperature decreases the basicity and the metals affinity of both adsorbents, but the uptake capacities remain practically unchanged. Moreover, increasing temperature substantially enhances intra-particle mass transport and decreases viscosities thus allowing significantly higher feed flow rates in the fixed-bed separation. The copper selectivity of both adsorbents is very high even in the presence of a 250-fold excess of zinc. However, because of the basicity of WP-1, metal precipitation is a serious problem and therefore only CuWRAM is suitable for the practical industrial application. The optimum temperature for copper removal appears to be around 60 oC and an alternative solution purification method is proposed. The Ni/Zn selectivity of both WP-1 and CuWRAM is insufficient for removal of the very small amounts of nickel present in the concentrated ZnSO4 solution.
Resumo:
A rotary thermal diffusion column with the inner cylinder rotating and the outer cylinder static was used to separate n-heptane-benzene mixtures at different speeds of rotation. The results show that the column efficiency depends on the speed of rotation. For the optimum speed the increase in efficiency relative to the static column was of the order of 8%. The role of the geometric irregularities in the annulus width on performance of the rotary column is also discussed.
Resumo:
Työssä tutkittiin jalometallien selektiivistä erottamista kloridiliuoksista synteettisten polymeerihartsien avulla. Laboratoriokokeissa keskityttiin tutkimaan kullan erottamista hydrofiilisen polymetakrylaattipohjaisen adsorbentin avulla. Lähtökohtana oli platinarikaste, joka sisälsi kullan lisäksi platinaa, palladiumia, hopeaa, kuparia, rautaa, vismuttia, seleeniä ja telluuria. Mittauksissa tutkittiin eri metallien ja puolimetallien adsorptiota hartsiin tasapaino-, kinetiikka- ja kolonnikokeilla. Työssä käytettiin myös adsorption simulointiin monikomponenttierotuksen dynaamiseen mallintamiseen tarkoitettua tietokoneohjelmaa, johon tarvittavat parametrit estimoitiin kokeellisen datan avulla. Tasapainokokeet yhtä metallia sisältäneistä liuoksista osoittivat, että hartsi adsorboi tehokkaasti kultaa kaikissa tutkituissa suolahappopitoisuuksissa (1-6 M). Kulta muodostaa hartsiin hyvin adsorboituvia tetrakloroauraatti(III)ioneja, [AuCl4]-, jotka ovat erittäin stabiileja pieniin kloridipitoisuuksiin saakka. Suolahappopitoisuudella oli merkitystä ainoastaan raudan adsorptioon, joka kasvoi huomattavasti suolahappopitoisuuden noustessa johtuen raudan taipumuksesta muodostaa hyvin adsorboituvia [FeCl4]--ioneja väkevissä suolahappopitoisuuksissa. Muiden tutkittujen alkuaineiden adsorptiot jäivät alhaisiksi kaikilla suolahappopitoisuuksilla. Rikasteliuoksella tehdyt tasapainokokeet osoittivat, että adsorptiokapasiteetti kullalle riippuu voimakkaasti muista läsnäolevista komponenteista. Kilpaileva adsorptio kuvattiin Langmuir-Freundlich-isotermillä. Kolonnikokeet osoittivat, että hartsi adsorboi kullan lisäksi hieman myös rautaa ja telluuria, jotka saatiin kuitenkin eluoitua hartsista täysin 5 M suolahappopesulla ja sitä seuraavalla 1 M suolahappopesulla. Tehokkaaksi liuokseksi kullan desorboimiseen osoittautui asetonin ja 1 M suolahapon seos. Kolonnierotuksen eri vaiheet pystyttiin tyydyttävästi kuvaamaan simulointimallilla.
Resumo:
Työssä tutkittiin kahden silikapohjaisen erotusmateriaalin soveltuvuutta nikkelin ja koboltin poistoon sinkkisulfaattiliuoksista. Suurin osa kokeista tehtiin ioninvaihtimella, jonka funktionaalinen ryhmä on iminodietikkahappo. Vertailuerotusmateriaalin toiminta perustui adsorptioon. Liuoksina käytettiin sekä autenttista prosessiliuosta että synteettistä ZnSO4-liousta. Ioninvaihtimen kestävyyskokeissa selvisi, että tutkittu ioninvaihdin kestää hyvin sekä 60 oC lämpötilan että happamia olosuhteita. Emäksisissä liuoksissa silikarunko ei kestä. Jo 0,1 M NaOH-liuos liuottaa merkittävästi hartsia vuorokauden aikana. Vaihtimen vetyionikapasiteetiksi saatiin titrauksella 2,3 mekv/g. Tasapainokokeilla saatiin selville, että ioninvaihdin on selektiivinen nikkelille sinkin suhteen ja että selektiivisyys kasvaa liuoksen pH:n laskiessa. Koboltille ioninvaihdin ei ole selektiivinen sinkin suhteen. Mikäli sinkin pitoisuus on tuhansia kertoja nikkelin pitoisuutta suurempi, ei ioninvaihtimen Ni-selektiivisyys riitä myöskään nikkelille. Synteettisillä ZnSO4-liuoksilla tehtyjen kolonnikokeiden perusteella havaittiin, että tutkitulla ioninvaihtimella voidaan laimeista ZnSO4-liuoksista poistaa nikkeliä selektiivisesti. Nikkelin eluointi onnistui helposti 1 M H2SO4:lla. Vertailukokeen perusteella oli ioninvaihtimen Ni/Zn-selektiivisyys referenssiadsorbentin Ni/Zn-selektiivisyyttä pienempi. Ioninvaihtokolonnin mallintaminen ei onnistunut riittävän hyvin kuvaamaan ioninvaihtimessa tapahtuvaa samanaikaista ioninvaihtoa ja adsorptiota. Sen sijaan kun kolonnissa oli vertailumateriaalina käytetty adsorbentti, saatiin kolonnikokeiden tulokset mallilla hyvin ennustettua.
Resumo:
Diplomityössä on tutkittu kuparin, koboltin, nikkelin ja kadmiumin poistamista sinkkisulfaattiliuoksista käyttäen uusia silikarunkoisia kelatoivia erotusmateriaaleja. Vertailukohteena on käytetty perinteisiä kaupallisia polymeerirunkoisia kelatoivia ioninvaihtohartseja. Laboratoriokokeissa selvitettiin erotusmateriaalien adsorptio- ja ioninvaihto-ominaisuuksia tasapaino- ja kolonnikokeilla. Silikarunkoisten erotusmateriaalien kemiallista kestävyyttä tutkittiin olosuhteissa, jotka vastaavat prosessisyklin eri vaiheita. Metallien adsorptiomekanismien selvittämiseksi erotusmateriaaleille tehtiin happo-emäs ja sulfaattititraukset. Tasapainokokeet osoittivat, että silikarunkoisilla erotusmateriaaleilla saatiin kupari erotettua väkevistä sinkkisulfaattiliuoksista polymeerirunkoisia kelatoivia ioninvaihtohartseja paremmin. Tutkituilla erotusmateriaaleilla ja ioninvaihtohartseilla ei havaittu merkittävää selektiivisyyttä koboltille, nikkelille tai kadmiumille sinkin ja kuparin läsnä ollessa. Kolonnikokeilla yritettiin löytää paras esikäsittely-lataus-eluointisykli kuparin talteenottoon väkevistä sinkkisulfaattiliuoksista silikarunkoisilla erotusmateriaaleilla. Kolonnikokeissa esikäsittely tehtiin laimealla NaOH:lla, jonka jälkeen petiin syötettiin hapanta sinkkisulfaattiliuosta. Eluointi onnistui hyvin laimealla rikkihapolla. Kolonnikokeiden tulokset osoittivat, että kupari on mahdollista erottaa väkevistä sinkkisulfaattiliuoksista. Silikarunkoisten erotusmateriaalien kemiallista kestävyyttä tutkittaessa havaittiin materiaalien kestävän hyvin happoja ja 60 oC:en lämpötilaa. Sitä vastoin alkaalisissa olosuhteissa tapahtui silikan liukenemista. Tutkituilla erotusmateriaaleilla havaittiin kuparin sitoutumista sekä ioninvaihtomekanismin avulla että sitoutuneena neutraalina suolana.
Resumo:
The purpose of this study was to develop a rapid, simple and sensitive quantitation method for pseudoephedrine (PSE), paracetamol (PAR) and loratadine (LOR) in plasma and pharmaceuticals using liquid chromatography-tandem mass spectrometry with a monolithic column. Separation was achieved using a gradient composition of methanol-0.1% formic acid at a flow rate of 1.0 mL min-1. Mass spectral transitions were recorded in SRM mode. System validation was evaluated for precision, specificity and linearity. Limit of detection for pseudoephedrine, paracetamol, and loratadine were determined to be 3.14, 1.86 and 1.44 ng mL-1, respectively, allowing easy determination in plasma with % recovery of 93.12 to 101.56%.
Resumo:
The consumption of manganese is increasing, but huge amounts of manganese still end up in waste in hydrometallurgical processes. The recovery of manganese from multi-metal solutions at low concentrations may not be economical. In addition, poor iron control typically prevents the production of high purity manganese. Separation of iron from manganese can be done with chemical precipitation or solvent extraction methods. Combined carbonate precipitation with air oxidation is a feasible method to separate iron and manganese due to the fast kinetics, good controllability and economical reagents. In addition the leaching of manganese carbonate is easier and less acid consuming than that of hydroxide or sulfide precipitates. Selective iron removal with great efficiency from MnSO4 solution is achieved by combined oxygen or air oxidation and CaCO3 precipitation at pH > 5.8 and at a redox potential of > 200 mV. In order to avoid gypsum formation, soda ash should be used instead of limestone. In such case, however, extra attention needs to be paid on the reagents mole ratios in order to avoid manganese coprecipitation. After iron removal, pure MnSO4 solution was obtained by solvent extraction using organophosphorus reagents, di-(2-ethylhexyl)phosphoric acid (D2EHPA) and bis(2,4,4- trimethylpentyl)phosphinic acid (CYANEX 272). The Mn/Ca and Mn/Mg selectivities can be increased by decreasing the temperature from the commonly used temperatures (40 –60oC) to 5oC. The extraction order of D2EHPA (Ca before Mn) at low temperature remains unchanged but the lowering of temperature causes an increase in viscosity and slower phase separation. Of these regents, CYANEX 272 is selective for Mn over Ca and, therefore, it would be the better choice if there is Ca present in solution. A three-stage Mn extraction followed by a two-stage scrubbing and two-stage sulfuric acid stripping is an effective method of producing a very pure MnSO4 intermediate solution for further processing. From the intermediate MnSO4 some special Mn- products for ion exchange applications were synthesized and studied. Three types of octahedrally coordinated manganese oxide materials as an alternative final product for manganese were chosen for synthesis: layer structured Nabirnessite, tunnel structured Mg-todorokite and K-kryptomelane. As an alternative source of pure MnSO4 intermediate, kryptomelane was synthesized by using a synthetic hydrometallurgical tailings. The results show that the studied OMS materials adsorb selectively Cu, Ni, Cd and K in the presence of Ca and Mg. It was also found that the exchange rates were reasonably high due to the small particle dimensions. Materials are stable in the studied conditions and their maximum Cu uptake capacity was 1.3 mmol/g. Competitive uptake of metals and acid was studied using equilibrium, batch kinetic and fixed-bed measurements. The experimental data was correlated with a dynamic model, which also accounts for the dissolution of the framework manganese. Manganese oxide micro-crystals were also bound onto silica to prepare a composite material having a particle size large enough to be used in column separation experiments. The MnOx/SiO2 ratio was found to affect significantly the properties of the composite. The higher the ratio, the lower is the specific surface area, the pore volume and the pore size. On the other hand, higher amount of silica binder gives composites better mechanical properties. Birnesite and todorokite can be aggregated successfully with colloidal silica at pH 4 and with MnO2/SiO2 weight ratio of 0.7. The best gelation and drying temperature was 110oC and sufficiently strong composites were obtained by additional heat-treatment at 250oC for 2 h. The results show that silica–supported MnO2 materials can be utilized to separate copper from nickel and cadmium. The behavior of the composites can be explained reasonably well with the presented model and the parameters estimated from the data of the unsupported oxides. The metal uptake capacities of the prepared materials were quite small. For example, the final copper loading was 0.14 mmol/gMnO2. According to the results the special MnO2 materials are potential for a specific environmental application to uptake harmful metal ions.
Resumo:
Lignocellulosic biomasses (e.g., wood and straws) are a potential renewable source for the production of a wide variety of chemicals that could be used to replace those currently produced by petrochemical industry. This would lead to lower greenhouse gas emissions and waste amounts, and to economical savings. There are many possible pathways available for the manufacturing of chemicals from lignocellulosic biomasses. One option is to hydrolyze the cellulose and hemicelluloses of these biomasses into monosaccharides using concentrated sulfuric acid as catalyst. This process is an efficient method for producing monosaccharides which are valuable platforn chemicals. Also other valuable products are formed in the hydrolysis. Unfortunately, the concentrated acid hydrolysis has been deemed unfeasible mainly due to high chemical consumption resulting from the need to remove sulfuric acid from the obtained hydrolysates prior to the downstream processing of the monosaccharides. Traditionally, this has been done by neutralization with lime. This, however, results in high chemical consumption. In addition, the by-products formed in the hydrolysis are not removed and may, thus, hinder the monosaccharide processing. In order to improve the feasibility of the concentrated acid hydrolysis, the chemical consumption should be decreased by recycling of sulfuric acid without neutralization. Furthermore, the monosaccharides and the other products formed in the hydrolysis should be recovered selectively for efficient downstream processing. The selective recovery of the hydrolysis by-products would have additional economical benefits on the process due to their high value. In this work, the use of chromatographic fractionation for the recycling of sulfuric acid and the selective recovery of the main components from the hydrolysates formed in the concentrated acid hydrolysis was investigated. Chromatographic fractionation based on the electrolyte exclusion with gel type strong acid cation exchange resins in acid (H+) form as a stationary phase was studied. A systematic experimental and model-based study regarding the separation task at hand was conducted. The phenomena affecting the separation were determined and their effects elucidated. Mathematical models that take accurately into account these phenomena were derived and used in the simulation of the fractionation process. The main components of the concentrated acid hydrolysates (sulfuric acid, monosaccharides, and acetic acid) were included into this model. Performance of the fractionation process was investigated experimentally and by simulations. Use of different process options was also studied. Sulfuric acid was found to have a significant co-operative effect on the sorption of the other components. This brings about interesting and beneficial effects in the column operations. It is especially beneficial for the separation of sulfuric acid and the monosaccharides. Two different approaches for the modelling of the sorption equilibria were investigated in this work: a simple empirical approach and a thermodynamically consistent approach (the Adsorbed Solution theory). Accurate modelling of the phenomena observed in this work was found to be possible using the simple empirical models. The use of the Adsorbed Solution theory is complicated by the nature of the theory and the complexity of the studied system. In addition to the sorption models, a dynamic column model that takes into account the volume changes of the gel type resins as changing resin bed porosity was also derived. Using the chromatography, all the main components of the hydrolysates can be recovered selectively, and the sulfuric acid consumption of the hydrolysis process can be lowered considerably. Investigation of the performance of the chromatographic fractionation showed that the highest separation efficiency in this separation task is obtained with a gel type resin with a high crosslinking degree (8 wt. %); especially when the hydrolysates contain high amounts of acetic acid. In addition, the concentrated acid hydrolysis should be done with as low sulfuric acid concentration as possible to obtain good separation performance. The column loading and flow rate also have large effects on the performance. In this work, it was demonstrated that when recycling of the fractions obtained in the chromatographic fractionation are recycled to preceding unit operations these unit operations should included in the performance evaluation of the fractionation. When this was done, the separation performance and the feasibility of the concentrated acid hydrolysis process were found to improve considerably. Use of multi-column chromatographic fractionation processes, the Japan Organo process and the Multi-Column Recycling Chromatography process, was also investigated. In the studied case, neither of these processes could compete with the single-column batch process in the productivity. However, due to internal recycling steps, the Multi-Column Recycling Chromatography was found to be superior to the batch process when the product yield and the eluent consumption were taken into account.
Resumo:
This paper describes a sequential injection chromatography procedure for determination of picloram in waters exploring the low backpressure of a 2.5 cm long monolithic C18 column. Separation of the analyte from the matrix was achieved in less than 60 s using a mobile phase composed by 20:80 (v v-1) acetonitrile:5.0 mmol L-1 H3PO4 and flow rate of 30 μL s-1. Detection was made at 223 nm with a 40 mm optical path length cell. The limits of detection and quantification were 33 and 137 μg L-1, respectively. The proposed method is sensitive enough to monitor the maximum concentration level for picloram in drinking water (500 μg L-1). The sampling frequency is 60 analyses per hour, consuming only 300 μL of acetonitrile per analysis. The proposed methodology was applied to spiked river water samples and no statistically significant differences were observed in comparison to a conventional HPLC-UV method.
Resumo:
Työssä tutkittiin moniarvoisten metalliformiaattien valmistusta ioninvaihto-menetelmällä. Kirjallisuustutkimus käsitteleetunnettuja alumiiniformiaatin ja rautaformiaatin valmistusmenetelmiä, kationinvaihtohartsien ominaisuuksia, ioninvaihtohartsien selektiivisyyttä ja alumiinin, raudan, magnesiumin ja sinkin vesikemiaa. Laboratoriokokeiden avulla tutkittiin sinkki-, magnesium-, rauta(II)- ja alumiiniformiaattien valmistusta ioninvaihdolla. Kokeet suoritettiin kolonnissa, joka oli pakattu makrohuokoisella tai geelimäisellä vahvalla kationin-vaihtohartsilla. Hartsi vaihdettiin natriummuodosta metallimuotoon metallikloridi- tai metallisulfaattiliuoksella.Metalli eluoitiin hartsista natriumformiaatilla. Formiaattien valmistus onnistui makrohuokoista vahvaa kationinvaihtohartsia käyttämällä. Rauta(II)formiaatin valmistus oli vaikeampaa kuin muiden formiaattien, koska rauta(II) hapettui osittain rauta(III):ksi valmistuksen aikana. Alumiiniformiaattia valmistettiin käyttäen sekä makrohuokoista että geelimäistä hartsia. Makrohuokoisen hartsin havaittiin soveltuvan geelimäistä hartsia paremmin alumiiniformiaatin valmistukseen. Kungeelimäistä hartsia käytettiin, noin 30 % alumiinista jäi kiinni hartsiin eikä siten eluoitunut. Ioninvaihdon selektiivisyyskertoimien saamiseksi suoritettiin tasapainokokeita. Selektiivisyyskertoimia käytettiin ioninvaihtokolonnin dynaamisessa simuloinnissa. Ioninvaihdon simuloiminen dynaamisella kolonnimallilla onnistui hyvin.
Resumo:
Sinkin valmistuksessa pitää sinkkirikasteesta poistaa epäpuhtausmetallit ennen elektrolyysiä. Nykyisin epäpuhtauksien poistamiseksi käytetään sementointimene-telmiä. Sementointi voisi olla mahdollista korvata kelatoivalla adsorbentilla suori-tettavalla erotuksella, jonka etuja ovat selektiivisyys ja ympäristöystävällisyys. Työn tarkoituksena on tutkia lämpötilan vaikutusta kelatoivalla adsorbentilla teh-tävään nikkelin ja kuparin kolonnierotukseen. Kolonnierotuksessa lämpötila voi vaikuttaa sekä liuoksen että adsorbentin fysi-kaalisiin, kemiallisiin ja sähkökemiallisiin ominaisuuksiin. Näiden vaikutusten johdosta voivat esimerkiksi erotuksen stoikiometria, kinetiikka tai toimintaolosuh-teet muuttua. Tässä työssä lämpötilan vaikutusta kolonnierotukseen tutkittiin rik-kihapon ja erotusmateriaalin välisillä kinetiikkakokeilla sekä synteettisellä CuSO4-liuoksella ja autenttisella ZnSO4-liuoksella tehdyillä kolonniajoilla. Työssä käytetyn erotusmateriaalin runko on silikapolyamiini ja sen funktionaali-sena ryhmänä toimii 2-aminometyylipyridiini. Lämpötilan ollessa 60 °C havaittiin erotusmateriaalin ja rikkihapon asettuvan tasapainoon kolme kertaa nopeammin kuin 25 °C:ssa. Lämpötilan nostamisella edelleen 90 °C:een ei havaittu olevan merkittävää vaikutusta tasapainon saavuttamisen nopeuteen. Kuparin läpäisykäyrän havaittiin jyrkentyvän lämpötilan noston vaikutuksesta niin autenttisella ZnSO4-liuoksella kuin synteettisellä CuSO4-liuoksella. Tämän oletettiin johtuvan kinetiikan nopeuden kasvusta sekä autenttisella liuoksella myös viskositeetin pienenemisestä. Lämpötilan vaikutuksesta on mahdollista käsitellä autenttista ZnSO4-liuosta 90 °C:ssa noin 3,5-kertaa enemmän kuin 25 °C:ssa, siten että liuoksesta saadaan poistettua lähes kaikki kupari. Nikkelin havaittiin lä-päisevän kolonnin kaikissa lämpötiloissa lähes välittömästi. Tästä syystä tutkittu erotusmateriaali ei sovellu nikkelin ja kuparin samanaikaiseen erottamiseen tutki-tusta autenttisesta ZnSO4-liuoksesta.
Resumo:
We investigated the influence of substrate surface roughness on the structural and magnetic properties of obliquely deposited amorphous nanocolumns of Fe–Ni. Experiments showed that the surface roughness of the substrate greatly determines the morphology of the columnar structures and this in turn has a profound influence on the magnetic properties. Nucleation of Fe–Ni nanocolumns on a smooth silicon substrate was at random, while that on a rough glass substrate was defined by the irregularities on the substrate surface. It has been found that magnetic interaction between the nanocolumns prepared on a silicon substrate was due to their small inter-column separation. Well separated nanocolumns on a glass substrate resulted in exchange isolated magnetic domains. The size, shape and the distribution of nanocolumns can be tailored by appropriately choosing the surface roughness of the substrate. This will find potential applications in thin film magnetism.
Resumo:
In this thesis, general approach is devised to model electrolyte sorption from aqueous solutions on solid materials. Electrolyte sorption is often considered as unwanted phenomenon in ion exchange and its potential as an independent separation method has not been fully explored. The solid sorbents studied here are porous and non-porous organic or inorganic materials with or without specific functional groups attached on the solid matrix. Accordingly, the sorption mechanisms include physical adsorption, chemisorption on the functional groups and partition restricted by electrostatic or steric factors. The model is tested in four Cases Studies dealing with chelating adsorption of transition metal mixtures, physical adsorption of metal and metalloid complexes from chloride solutions, size exclusion of electrolytes in nano-porous materials and electrolyte exclusion of electrolyte/non-electrolyte mixtures. The model parameters are estimated using experimental data from equilibrium and batch kinetic measurements, and they are used to simulate actual single-column fixed-bed separations. Phase equilibrium between the solution and solid phases is described using thermodynamic Gibbs-Donnan model and various adsorption models depending on the properties of the sorbent. The 3-dimensional thermodynamic approach is used for volume sorption in gel-type ion exchangers and in nano-porous adsorbents, and satisfactory correlation is obtained provided that both mixing and exclusion effects are adequately taken into account. 2-Dimensional surface adsorption models are successfully applied to physical adsorption of complex species and to chelating adsorption of transition metal salts. In the latter case, comparison is also made with complex formation models. Results of the mass transport studies show that uptake rates even in a competitive high-affinity system can be described by constant diffusion coefficients, when the adsorbent structure and the phase equilibrium conditions are adequately included in the model. Furthermore, a simplified solution based on the linear driving force approximation and the shrinking-core model is developed for very non-linear adsorption systems. In each Case Study, the actual separation is carried out batch-wise in fixed-beds and the experimental data are simulated/correlated using the parameters derived from equilibrium and kinetic data. Good agreement between the calculated and experimental break-through curves is usually obtained indicating that the proposed approach is useful in systems, which at first sight are very different. For example, the important improvement in copper separation from concentrated zinc sulfate solution at elevated temperatures can be correctly predicted by the model. In some cases, however, re-adjustment of model parameters is needed due to e.g. high solution viscosity.
Resumo:
Axial deflection of DNA molecules in solution results from thermal motion and intrinsic curvature related to the DNA sequence. In order to measure directly the contribution of thermal motion we constructed intrinsically straight DNA molecules and measured their persistence length by cryo-electron microscopy. The persistence length of such intrinsically straight DNA molecules suspended in thin layers of cryo-vitrified solutions is about 80 nm. In order to test our experimental approach, we measured the apparent persistence length of DNA molecules with natural "random" sequences. The result of about 45 nm is consistent with the generally accepted value of the apparent persistence length of natural DNA sequences. By comparing the apparent persistence length to intrinsically straight DNA with that of natural DNA, it is possible to determine both the dynamic and the static contributions to the apparent persistence length.
Resumo:
The analysis of water samples containing volatile organic compounds has become an important task in analytical chemistry. Gas chromatography has been widely used for the analysis of volatile organic compounds in water. The headspace analysis shows as a principal characteristic the possibility of determination of the volatile components in drinking water. Benzene, Toluene and Xylene (BTX) are important compounds usually present in drinking water, from contamination by petroleum derivatives. Since they are toxic compounds even when present in low concentration levels, their determination is important in order to define the quality of the water. The sampling technique using headspace, coupled with gas chromatography as the separation method, showed to be suitable for BTX analysis in several samples at the mug/L (ppb) level.