970 resultados para Cobas Amplicor HBV monitor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to standardise an in-house real-time polymerase chain reaction (rtPCR) to allow quantification of hepatitis B virus (HBV) DNA in serum or plasma samples, and to compare this method with two commercial assays, the Cobas Amplicor HBV monitor and the Cobas AmpliPrep/Cobas TaqMan HBV test. Samples from 397 patients from the state of São Paulo were analysed by all three methods. Fifty-two samples were from patients who were human immunodeficiency virus and hepatitis C virus positive, but HBV negative. Genotypes were characterised, and the viral load was measure in each sample. The in-house rtPCR showed an excellent success rate compared with commercial tests; inter-assay and intra-assay coefficients correlated with commercial tests (r = 0.96 and r = 0.913, p < 0.001) and the in-house test showed no genotype-dependent differences in detection and quantification rates. The in-house assay tested in this study could be used for screening and quantifying HBV DNA in order to monitor patients during therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we evaluated the hepatitis B virus (HBV) genotype distribution and HBV genomic mutations among a group of human immunodeficiency virus-HBV co-infected patients from an AIDS outpatient clinic in São Paulo. HBV serological markers were detected by commercially available enzyme immunoassay kits. HBV DNA was detected using in-house nested polymerase chain reaction and quantified by Cobas Amplicor. HBV genotypes and mutations in the basal core promoter (BCP)/pre-core/core regions and surface/polymerase genes were determined by sequencing. Among the 59 patients included in this study, 55 reported prior use of lamivudine (LAM) or tenofovir. HBV DNA was detected in 16/22 patients, with a genotype distribution of A (n = 12,75%), G (n = 2,13%), D (n = 1,6%) and F (n = 1,6%). The sequence data of the two patients infected with genotype G strongly suggested co-infection with genotype A. In 10 patients with viremia, LAM-resistance mutations in the polymerase gene (rtL180M + rtM204V and rtV173L + rtL180M + rtM204V) were found, accompanied by changes in the envelope gene (sI195M, sW196L and sI195M/sE164D). Mutations in the BCP and pre-core regions were identified in four patients. In conclusion, genotype G, which is rarely seen in Brazil, was observed in the group of patients included in our study. A high prevalence of mutations associated with LAM-resistance and mutations associated with anti-HBs resistance were also found among these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Anti-HBc positivity is a frequent cause of donation rejection at blood banks. Hepatitis B virus (HBV) infection may also occur in HBsAg-negative patients, a situation denoted occult infection. Similarly, very low levels of HBV-DNA have also been found in the sera of patients with chronic hepatitis C virus (HCV) infection, even in the absence of serum HBsAg. Initially we searched for HBV-DNA in serum of 100 blood donors and 50 HCV-infected patients who were HBsAg negative/anti-HBc positive by nested-PCR and by an HBV monitor commercial test for HBV-DNA. Anti-HBs seroconversion rates were measured in 100 blood donors and in 22 patients with chronic HCV infection after HBV vaccination to determine if the HBV vaccination could eliminate an occult HBV infection in these individuals. Occult HBV infection was detected in proportionally fewer blood donors (6/100 = 6%) than chronic hepatitis C patients (12/50 = 24%) (P < 0.05). We noted seroconversion in 6/6 (100%) HBV-DNA(+) and in 84/94 (89.4%) HBV-DNA(-) blood donors (P > 0.05). All subjects who were HBV-DNA(+) before the first dose of HBV vaccine (D1), became HBV-DNA(-) after D1, D2, and D3. Among 22 HCV-positive patients, 10 HBV-DNA(+) and 12 HBV-DNA(-), seroconversion was observed in 9/10 (90%) HBV-DNA(+) and in 9/12 (75%) HBV-DNA(-) subjects (P > 0.05). The disappearance of HBV-DNA in the majority of vaccinated patients suggests that residual HBV can be eliminated in patients with occult infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chlamydia trachomatis é o agente causal de uma das infecções sexualmente transmissíveis (IST) mais prevalentes da atualidade. Os maiores problemas no controle desta IST estão no caráter assintomático da infecção e no seu difícil diagnóstico laboratorial. Com o advento dos testes moleculares, grandes avanços ocorreram na área do diagnóstico laboratorial da infecção clamidial. O presente trabalho teve por objetivo desenvolver um método de detecção de C. trachomatis por PCR a partir de amostras cérvico-vaginais. A seqüência alvo escolhida para amplificação consiste de um segmento da ORF 4 do plasmídio críptico de ocorrência natural nesta bactéria. Noventa e duas amostras cérvico-vaginais foram submetidas ao protocolo de PCR in house proposto. Os produtos de PCR foram detectados por visualização direta após eletroforese em gel de agarose com brometo de etídio e por exposição radiográfica após hibridização com sonda homóloga. As amostras foram testadas paralelamente pelo método de captura híbrida para detecção de C. trachomatis. O kit COBAS Amplicor (Roche) foi utilizado para resolver resultados discrepantes. A seqüência do fragmento de 201pb foi confirmada por clivagem enzimática e por seqüenciamento. O teste de especificidade dos primers confirmou especificidade dos mesmos frente ao DNA de diferentes agentes patogênicos e da flora normal feminina. Do total de amostras analisadas, 50 foram positivas por captura híbrida, 51 foram positivas por PCR in house e 67 positivaram após hibridização.O teste de McNemar indicou haver concordância entre os métodos analisados dois a dois (P<0,001). Verificou-se concordância moderada nos comparativos entre captura híbrida e PCR (valor de Kappa: 0,45; DP 0,093), captura híbrida e hibridização (valor de kappa: 0,389; DP 0,091) e, PCR e hibridização (valor de Kappa: 0,634: DP 0,077). O método de PCR in house proposto para a detecção de C. trachomatis é uma técnica rápida e de baixo custo para o diagnóstico, controle e monitoramento dos casos da infecção. Estudos complementares, no entanto, são necessários para implementação deste teste em laboratórios da rede pública.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Access to hepatitis B viral load (VL) testing is poor in sub-Saharan Africa (SSA) due toeconomic and logistical reasons.Objectives: To demonstrate the feasibility of testing dried blood spots (DBS) for hepatitis B virus (HBV)VL in a laboratory in Lusaka, Zambia, and to compare HBV VLs between DBS and plasma samples.Study design: Paired plasma and DBS samples from HIV-HBV co-infected Zambian adults were analyzedfor HBV VL using the COBAS AmpliPrep/COBAS TaqMan HBV test (Version 2.0) and for HBV genotypeby direct sequencing. We used Bland-Altman analysis to compare VLs between sample types and bygenotype. Logistic regression analysis was conducted to assess the probability of an undetectable DBSresult by plasma VL.Results: Among 68 participants, median age was 34 years, 61.8% were men, and median plasma HBV VLwas 3.98 log IU/ml (interquartile range, 2.04–5.95). Among sequenced viruses, 28 were genotype A1 and27 were genotype E. Bland–Altman plots suggested strong agreement between DBS and plasma VLs. DBSVLs were on average 1.59 log IU/ml lower than plasma with 95% limits of agreement of −2.40 to −0.83 logIU/ml. At a plasma VL ≥2,000 IU/ml, the probability of an undetectable DBS result was 1.8% (95% CI:0.5–6.6). At plasma VL ≥20,000 IU/ml this probability reduced to 0.2% (95% CI: 0.03–1.7).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Roche Cobas Amplicor system is widely used for the detection of Neisseria gonorrhoeae but is known to cross react with some commensal Neisseria spp. Therefore, a confirmatory test is required. The most common target for confirmatory tests is the cppB gene of N. gonorrhoeae. However, the cppB gene is also present in other Neisseria spp. and is absent in some N. gonorrhoeae isolates. As a result, laboratories targeting this gene run the risk of obtaining both false-positive and false-negative results. In the study presented here, a newly developed N. gonorrhoeae LightCycler assay (NGpapLC) targeting the N. gonorrhoeae porA pseudogene was tested. The NGpapLC assay was used to test 282 clinical samples, and the results were compared to those obtained using a testing algorithm combining the Cobas Amplicor System (Roche Diagnostics, Sydney, Australia) and an in-house LightCycler assay targeting the cppB gene (cppB-LC). In addition, the specificity of the NGpapLC assay was investigated by testing a broad panel of bacteria including isolates of several Neisseria spp. The NGpapLC assay proved to have comparable clinical sensitivity to the cppB-LC assay. In addition; testing of the bacterial panel showed the NGpapLC assay to be highly specific for N. gonorrhoeae DNA. The results of this study show the NGpapLC assay is a suitable alternative to the cppB-LC assay for confirmation of N. gonorrhoeae-positive results obtained with Cobas Amplicor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The quantitation of serum HBeAg is not commonly used to monitor viral response to therapy in chronic hepatitis B. METHODS: In this study, 21 patients receiving varying therapies were followed and their viral response monitored by concomitant viral load and HBeAg quantitation in order to study the meaning and the kinetics of both parameters. RESULTS: It was possible to distinguish between three different patterns of viral response. The first was characterized by a simultaneous decrease in serum HBV DNA and HBeAg. The second pattern was characterized by a decrease in serum HBeAg but persistent detection of HBV DNA. The third pattern was characterized by undetectable HBV DNA with persistent HBeAg positivity, which points to a non-response (Pattern III-B) except when HBeAg levels showed a slow but steady drop, characterizing a "slow responder" patient (Pattern III-A). CONCLUSIONS: The first pattern is compatible with a viral response. A long-term HBeAg seropositivity with a slow and persistent decrease (Pattern III-A) is also compatible with a viral response and calls for a prolongation of anti-viral treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The Shwachman-Kulczycki score was the first scoring system used in cystic fibrosis to assess disease severity. Despite its subjectivity, it is still widely used. OBJECTIVE: To study correlations among forced expiratory volume in one second (FEV1), chest radiography, chest computed tomography, 6-minute walk test, and Shwachman-Kulczycki score in patients with cystic fibrosis and to test whether the Shwachman-Kulczycki score is still useful in monitoring the severity of the disease. METHODS: A cross-sectional prospective study was performed to analyze the correlations (Spearman). Patients with clinically stable cystic fibrosis, aged 3-21 years, were included. RESULTS: 43 patients, 19F/24M, mean age 10.5 + 4.7 years, with a median Shwachman-Kulczycki score of 70 were studied. The median Brasfield and Bhalla scores were 17 and 10, respectively. The mean Z score for the 6-minute walk test was -1.1 + 1.106 and the mean FEV1 was 59 + 26 (as percentage of predicted values). The following significant correlations versus the Shwachman-Kulczycki score were found: FEV1 (r = 0.76), 6-minute walk test (r = 0.71), chest radiography (r = 0.71) and chest computed tomography (r = -0.78). When patients were divided according to FEV1, a statistically significantly correlation with the Shwachman-Kulczycki score was found only in patients with FEV1 <70% (r = 0.67). CONCLUSIONS: The Shwachman-Kulczycki score remains an useful tool for monitoring the severity of cystic fibrosis, adequately reflecting the functional impairment and chest radiography and tomography changes, especially in patients with greater impairment of lung function. When assessing patients with mild lung disease its limitations should be considered and its usefulness in such patients should be evaluated in larger populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hepatitis B virus (HBV) can be classified into nine genotypes (A-I) defined by sequence divergence of more than 8% based on the complete genome. This study aims to identify the genotypic distribution of HBV in 40 HBsAg-positive patients from Rondonia, Brazil. A fragment of 1306 bp partially comprising surface and polymerase overlapping genes was amplified by PCR. Amplified DNA was purified and sequenced. Amplified DNA was purified and sequenced on an ABI PRISM (R) 377 Automatic Sequencer (Applied Biosystems, Foster City, CA, USA). The obtained sequences were aligned with reference sequences obtained from the GenBank using Clustal X software and then edited with Se-Al software. Phylogenetic analyses were conducted by the Markov Chain Monte Carlo (MCMC) approach using BEAST v.1.5.3. Results: The subgenotypes distribution was A1 (37.1%), D3 (22.8%), F2a (20.0%), D4 (17.1%) and D2 (2.8%). Conclusions: These results for the first HBV genotypic characterization in Rondonia state are consistent with other studies in Brazil, showing the presence of several HBV genotypes that reflects the mixed origin of the population, involving descendants from Native Americans, Europeans, and Africans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: GB virus C (GBV-C) is an enveloped positive-sense ssRNA virus belonging to the Flaviviridae family. Studies on the genetic variability of the GBV-C reveals the existence of six genotypes: genotype 1 predominates in West Africa, genotype 2 in Europe and America, genotype 3 in Asia, genotype 4 in Southwest Asia, genotype 5 in South Africa and genotype 6 in Indonesia. The aim of this study was to determine the frequency and genotypic distribution of GBV-C in the Colombian population. Methods: Two groups were analyzed: i) 408 Colombian blood donors infected with HCV (n = 250) and HBV (n = 158) from Bogota and ii) 99 indigenous people with HBV infection from Leticia, Amazonas. A fragment of 344 bp from the 5' untranslated region (5' UTR) was amplified by nested RT PCR. Viral sequences were genotyped by phylogenetic analysis using reference sequences from each genotype obtained from GenBank (n = 160). Bayesian phylogenetic analyses were conducted using Markov chain Monte Carlo (MCMC) approach to obtain the MCC tree using BEAST v. 1.5.3. Results: Among blood donors, from 158 HBsAg positive samples, eight 5.06% (n = 8) were positive for GBV-C and from 250 anti-HCV positive samples, 3.2%(n = 8) were positive for GBV-C. Also, 7.7% (n = 7) GBV-C positive samples were found among indigenous people from Leticia. A phylogenetic analysis revealed the presence of the following GBV-C genotypes among blood donors: 2a (41.6%), 1 (33.3%), 3 (16.6%) and 2b (8.3%). All genotype 1 sequences were found in co-infection with HBV and 4/5 sequences genotype 2a were found in co-infection with HCV. All sequences from indigenous people from Leticia were classified as genotype 3. The presence of GBV-C infection was not correlated with the sex (p = 0.43), age (p = 0.38) or origin (p = 0.17). Conclusions: It was found a high frequency of GBV-C genotype 1 and 2 in blood donors. The presence of genotype 3 in indigenous population was previously reported from Santa Marta region in Colombia and in native people from Venezuela and Bolivia. This fact may be correlated to the ancient movements of Asian people to South America a long time ago.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Viral hepatitis B, C and delta still remain a serious problem worldwide. In Colombia, data from 1980s described that HBV and HDV infection are important causes of hepatitis, but little is known about HCV infection. The aim of this study was to determine the currently frequency of HBV, HCV and HDV in four different Colombian regions. Methodology/Principal Findings: This study was conducted in 697 habitants from 4 Colombian departments: Amazonas, Choco, Magdalena and San Andres Islands. Epidemiological data were obtained from an interview applied to each individual aiming to evaluate risk factors related to HBV, HCV or HDV infections. All samples were tested for HBsAg, anti-HBc, anti-HBs and anti-HCV markers. Samples that were positive to HBsAg and/or anti-HBc were tested to anti-HDV. Concerning the geographical origin of the samples, the three HBV markers showed a statistically significant difference: HBsAg (p = 0.033) and anti-HBc (p < 0.001) were more frequent in Amazonas and Magdalena departments. Isolated anti-HBs (a marker of previous vaccination) frequencies were: Choco (53.26%), Amazonas (32.88%), Magdalena (17.0%) and San Andres (15.33%) p < 0.001. Prevalence of anti-HBc increased with age; HBsAg varied from 1.97 to 8.39% (p = 0.033). Amazonas department showed the highest frequency for anti-HCV marker (5.68%), while the lowest frequency was found in San Andres Island (0.66%). Anti-HDV was found in 9 (5.20%) out of 173 anti-HBc and/or HBsAg positive samples, 8 of them from the Amazonas region and 1 from them Magdalena department. Conclusions/Significance: In conclusion, HBV, HCV and HDV infections are detected throughout Colombia in frequency levels that would place some areas as hyperendemic for HBV, especially those found in Amazonas and Magdalena departments. Novel strategies to increase HBV immunization in the rural population and to strengthen HCV surveillance are reinforced by these results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter a is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and alpha that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique for improving the performance of an OSNR monitor based on a polarisation nulling method with the downhill simplex algorithm is demonstrated. Establishing a compromise between accuracy and acquisition time, the monitor has been calibrated to 0.72 dB/390 ms and 0.98 dB/320 ms, over a range of nearly 21 dB. As far as is known, these are the best values achieved with such an OSNR monitoring method.