A new monitor for routine thermal and epithermal neutron fluence rate monitoring in k(0) INAA


Autoria(s): KOSTER-AMMERLAAN, M. J. J.; BACCHI, M. A.; BODE, P.; FERNANDES, E. A. De Nadai
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

18/10/2012

18/10/2012

2008

Resumo

The Zr-Au set for monitoring the thermal and epithermal neutron fluence rate and the epithermal spectrum parameter a is not always practicable for routine application of INAA in well-thermalized facilities. An alternative set consisting of Cr, Au and Mo provides values for the thermal neutron fluence rate, f and alpha that are not significantly different from those found via the Zr-Au method and the Cd-covered Zr-method. The IRMM standard SMELS-II was analyzed using the (Au-Cr-Mo) monitor and a good agreement was obtained. (C) 2008 Elsevier Ltd. All rights reserved.

Identificador

APPLIED RADIATION AND ISOTOPES, v.66, n.12, p.1964-1969, 2008

0969-8043

http://producao.usp.br/handle/BDPI/17038

10.1016/j.apradiso.2008.06.001

http://dx.doi.org/10.1016/j.apradiso.2008.06.001

Idioma(s)

eng

Publicador

PERGAMON-ELSEVIER SCIENCE LTD

Relação

Applied Radiation and Isotopes

Direitos

restrictedAccess

Copyright PERGAMON-ELSEVIER SCIENCE LTD

Palavras-Chave #Neutron fluence rate monitoring #k(0)-NAA #Zr-Au #Au-Cr-Mo #SMELS-II #ACTIVATION ANALYSIS #NUCLEAR-DATA #Chemistry, Inorganic & Nuclear #Nuclear Science & Technology #Radiology, Nuclear Medicine & Medical Imaging