920 resultados para Blood pressure--Measurement
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
OBJECTIVE: To determine technical procedures and criteria used by Brazilian physicians for measuring blood pressure and diagnosing hypertension. METHODS: A questionnaire with 5 questions about practices and behaviors regarding blood pressure measurement and the diagnosis of hypertension was sent to 25,606 physicians in all Brazilian regions through a mailing list. The responses were compared with the recommendations of a specific consensus and descriptive analysis. RESULTS: Of the 3,621 (14.1%) responses obtained, 57% were from the southeastern region of Brazil. The following items were reported: use of an aneroid device by 67.8%; use of a mercury column device by 14.6%; 11.9% of the participants never calibrated the devices; 35.7% calibrated the devices at intervals < 1 year; 85.8% measured blood pressure in 100% of the medical visits; 86.9% measured blood pressure more than once and on more than one occasion. For hypertension diagnosis, 55.7% considered the patient's age, and only 1/3 relied on consensus statements. CONCLUSION: Despite the adequate frequency of both practices, it was far from that expected, and some contradictions between the diagnostic criterion for hypertension and the number of blood pressure measurements were found. The results suggest that, to include the great majority of the medical professionals, disclosure of consensus statements and techniques for blood pressure measurement should go beyond the boundaries of medical events and specialized journals.
Resumo:
OBJECTIVE: To assess the Dixtal DX2710 automated oscillometric device used for blood pressure measurement according to the protocols of the BHS and the AAMI. METHODS: Three blood pressure measurements were taken in 94 patients (53 females 15 to 80 years). The measurements were taken randomly by 2 observers trained to measure blood pressure with a mercury column device connected with an automated device. The device was classified according to the protocols of the BHS and AAMI. RESULT: The mean of blood pressure levels obtained by the observers was 148±38/93±25 mmHg and that obtained with the device was 148±37/89±26 mmHg. Considering the differences between the measurements obtained by the observer and those obtained with the automated device according to the criteria of the BHS, the following classification was adopted: "A" for systolic pressure (69% of the differences < 5; 90% < 10; and 97% < 15 mmHg); and "B" for diastolic pressure (63% of the differences < 5; 83% < 10; and 93% < 15 mmHg). The mean and standard deviation of the differences were 0±6.27 mmHg for systolic pressure and 3.82±6.21 mmHg for diastolic pressure. CONCLUSION: The Dixtal DX2710 device was approved according to the international recommendations.
Resumo:
OBJECTIVE: To assess blood pressure measurement by health professionals of a public hospital in São Paulo State. METHODS: Semi-structured interviews and direct observation were performed with a verification list according to the criteria reported by Perloff et al. One hundred and five health professionals took part in the study. After measuring blood pressure, the level of concordance between the way the procedure was performed and the recommended one was assessed. RESULTS: Nurses and nurse's aides abided by 40% of the recommended procedures for adequate blood pressure measurement. The other categories of health professionals (nursing and medicine teachers, physicians, residents, and nursing students) abided by approximately 70%. CONCLUSION: Permanent educational activities aiming at standardizing blood pressure measurement should be implemented among the different categories of health professionals.
Resumo:
The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.
Resumo:
Children with elevated blood pressure are at risk of being hypertensive in adulthood and of developing complications such as ventricular hypertrophy. Obesity is a cause of hypertension. Because the prevalence of obesity is increasing, some authors argue that the systematic screening for hypertension in children and adolescents is justified for early prevention and treatment. Sex, age and height all influence children's blood pressure. When elevated blood pressure is identified, complementary investigations and treatment might be necessary. However, due to the difficulties of obtaining a valid estimate of blood pressure, to the moderate tracking of blood pressure from childhood to adulthood, and the rarity of hypertension cases in childhood, the usefulness of systematic screening of hypertension during childhood is still controversial. Un enfant dont la pression artérielle est élevée a un risque accru d'être hypertendu à l'âge adulte et de présenter des complications telles que l'hypertrophie ventriculaire gauche. L'augmentation de la prévalence de l'obésité justifierait selon certains auteurs le dépistage systématique de l'hypertension dès le plus jeune âge afin d'instaurer des mesures préventives ou curatives précoces. Les normes de pression dépendent du sexe, de l'âge et de la taille de l'enfant. En cas de pression élevée, des investigations complémentaires, voire un traitement, peuvent être indiqués. Au vu des difficultés pour obtenir une mesure fiable, des incertitudes entachant la valeur pronostique d'une pression artérielle élevée et de la rareté des cas d'hypertension, il n'y a pas de consensus sur l'utilité du dépistage systématique de l'hypertension durant l'enfance.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.
Resumo:
Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.
Resumo:
Verenpaineen kotimittaus − epidemiologia ja kliininen käyttö Kohonnutta verenpainetta, maailmanlaajuisesti merkittävintä ennenaikaiselle kuolemalle altistavaa riskitekijää, ei voida tunnistaa tai hoitaa ilman tarkkoja ja käytännöllisiä verenpaineen mittausmenetelmiä. Verenpaineen kotimittaus on saavuttanut suuren suosion potilaiden keskuudessa. Lääkärit eivät ole kuitenkaan vielä täysin hyväksyneet verenpaineen kotimittausta, sillä riittävä todistusaineisto sen toimivuudesta ja eduista on puuttunut. Tämän tutkimuksen tarkoituksena oli osoittaa, että kotona mitattu verenpaine (kotipaine) on perinteistä vastaanotolla mitattua verenpainetta (vastaanottopaine) tarkempi, ja että se on tehokas myös kliinisessä käytössä. Tutkimme kotipaineen käyttöä verenpainetaudin diagnosoinnissa ja hoidossa. Lisäksi tarkastelimme kotipaineen yhteyttä verenpainetaudin aiheuttamiin kohde-elinvaurioihin. Ensimmäinen aineisto, joka oli edustava otos Suomen aikuisväestöstä, koostui 2 120 45–74-vuotiaasta tutkimushenkilöstä. Tutkittavat mittasivat kotipainettaan viikon ajan ja osallistuivat terveystarkastukseen, johon sisältyi kliinisen tutkimuksen ja haastattelun lisäksi sydänfilmin otto ja vastaanottopaineen mittaus. 758 tutkittavalle suoritettiin lisäksi kaulavaltimon seinämän intima-mediakerroksen paksuuden (valtimonkovettumataudin mittari) mittaus ja 237:lle valtimon pulssiaallon nopeuden (valtimojäykkyyden mittari) mittaus. Toisessa aineistossa, joka koostui 98 verenpainetautia sairastavasta potilaasta, hoitoa ohjattiin satunnaistamisesta riippuen joko ambulatorisen eli vuorokausirekisteröinnillä mitatun verenpaineen tai kotipaineen perusteella. Vastaanottopaine oli kotipainetta merkittävästi korkeampi (systolisen/diastolisen paineen keskiarvoero oli 8/3 mmHg) ja yksimielisyys verenpainetaudin diagnoosissa kahden menetelmän välillä oli korkeintaan kohtalainen (75 %). 593 tutkittavasta, joilla oli kohonnut verenpaine vastaanotolla, 38 %:lla oli normaali verenpaine kotona eli ns. valkotakkiverenpaine. Verenpainetauti voidaan siis ylidiagnosoida joka kolmannella potilaalla seulontatilanteessa. Valkotakkiverenpaine oli yhteydessä lievästi kohonneeseen verenpaineeseen, matalaan painoindeksiin ja tupakoimattomuuteen, muttei psykiatriseen sairastavuuteen. Valkotakkiverenpaine ei kuitenkaan vaikuttaisi olevan täysin vaaraton ilmiö ja voi ennustaa tulevaa verenpainetautia, sillä siitä kärsivien sydän- ja verisuonitautien riskitekijäprofiili oli normaalipaineisten ja todellisten verenpainetautisten riskitekijäprofiilien välissä. Kotipaineella oli vastaanottopainetta vahvempi yhteys verenpainetaudin aiheuttamiin kohde-elinvaurioihin (intima-mediakerroksen paksuus, pulssiaallon nopeus ja sydänfilmistä todettu vasemman kammion suureneminen). Kotipaine oli tehokas verenpainetaudin hoidon ohjaaja, sillä kotipaineeseen ja ambulatoriseen paineeseen, jota on pidetty verenpainemittauksen ”kultaisena standardina”, perustuva lääkehoidon ohjaus johti yhtä hyvään verenpaineen hallintaan. Tämän ja aikaisempien tutkimusten tulosten pohjalta voidaan todeta, että verenpaineen kotimittaus on selkeä parannus perinteiseen vastaanotolla tapahtuvaan verenpainemittaukseen verrattuna. Verenpaineen kotimittaus on käytännöllinen, tarkka ja laajasti saatavilla oleva menetelmä, josta voi tulla jopa ensisijainen vaihtoehto verenpainetautia diagnosoitaessa ja hoitaessa. Verenpaineen mittauskäytäntöön tarvitaan muutos, sillä näyttöön perustuvan lääketieteen perusteella vaikuttaa, että vastaanotolla tapahtuvaa verenpainemittausta tulisi käyttää vain seulontatarkoitukseen.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.
Resumo:
OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.
Resumo:
OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.