Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs


Autoria(s): Wernick, Morena B.; Höpfner, Robert M.; Francey, Thierry; Howard, J.
Data(s)

15/04/2012

Resumo

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Formato

application/pdf

Identificador

http://boris.unibe.ch/39454/1/javma.240.8.pdf

Wernick, Morena B.; Höpfner, Robert M.; Francey, Thierry; Howard, J. (2012). Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs. Journal of the American Veterinary Medical Association, 240(8), pp. 962-968. American Veterinary Medical Association 10.2460/javma.240.8.962 <http://dx.doi.org/10.2460/javma.240.8.962>

doi:10.7892/boris.39454

info:doi:10.2460/javma.240.8.962

info:pmid:22471825

urn:issn:0003-1488

Idioma(s)

eng

Publicador

American Veterinary Medical Association

Relação

http://boris.unibe.ch/39454/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Wernick, Morena B.; Höpfner, Robert M.; Francey, Thierry; Howard, J. (2012). Comparison of arterial blood pressure measurements and hypertension scores obtained by use of three indirect measurement devices in hospitalized dogs. Journal of the American Veterinary Medical Association, 240(8), pp. 962-968. American Veterinary Medical Association 10.2460/javma.240.8.962 <http://dx.doi.org/10.2460/javma.240.8.962>

Palavras-Chave #630 Agriculture
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed