557 resultados para Waveform
Resumo:
A non-invasive technique is implemented to measure a parameter which is closely related to the distensibility of large arteries, using the second derivative of the infrared photoplethysmographic waveform. Thirty subjects within the age group of 20-61 years were involved in this pilot study. Two new parameters, namely the area of the photoplethysmographic waveform under the systolic peak, and the ratio of the time delay between the systolic and the diastolic peaks and the time period of the waveform ( T/T) were studied as a function of age. It was found that while the parameter which is supposed to be a marker of distensibility of large arteries and T /T values correlate negatively with age, the area under the systolic peak correlates positively with age. The results suggest that the derived parameters could provide a simple, non-invasive means for studying the changes in the elastic properties of the vascular system as a function of age.
Resumo:
This thesis addresses one of the emerging topics in Sonar Signal Processing.,viz.the implementation of a target classifier for the noise sources in the ocean, as the operator assisted classification turns out to be tedious,laborious and time consuming.In the work reported in this thesis,various judiciously chosen components of the feature vector are used for realizing the newly proposed Hierarchical Target Trimming Model.The performance of the proposed classifier has been compared with the Euclidean distance and Fuzzy K-Nearest Neighbour Model classifiers and is found to have better success rates.The procedures for generating the Target Feature Record or the Feature vector from the spectral,cepstral and bispectral features have also been suggested.The Feature vector ,so generated from the noise data waveform is compared with the feature vectors available in the knowledge base and the most matching pattern is identified,for the purpose of target classification.In an attempt to improve the success rate of the Feature Vector based classifier,the proposed system has been augmented with the HMM based Classifier.Institutions where both the classifier decisions disagree,a contention resolving mechanism built around the DUET algorithm has been suggested.
Resumo:
RMS measuring device is a nonlinear device consisting of linear and nonlinear devices. The performance of rms measurement is influenced by a number of factors; i) signal characteristics, 2) the measurement technique used and 3) the device characteristics. RMS measurement is not simple, particularly when the signals are complex and unknown. The problem of rms measurement on high crest-factor signals is fully discussed and a solution to this problem is presented in this thesis. The problem of rms measurement is systematically analized and found to have mainly three types of errors: (1) amplitude or waveform error 2) Frequency error and (3) averaging error. Various rms measurement techniques are studied and compared. On the basis of this study the rms -measurement is reclassified three categories: (1) Wave-form-error-free measurement (2) High-frequncy-error measurement and (3) Low-frequency error-free measurement. In modern digital sampled-data systems the signals are complex and waveform-error-free rms measurement is highly appreciated. Among the three basic blocks of rms measuring device the squarer is the most important one. A squaring technique is selected, that permits shaping of the squarer error characteristic in such a way as to achieve waveform-errob free rms measurement. The squarer is designed, fabricated and tested. A hybrid rms measurement using an analog rms computing device and digital display combines the speed of analog techniques and the resolution and ease of measurement of digital techniques. An A/D converter is modified to perform the square-rooting operation. A 10-V rms voltmeter using the developed rms detector is fabricated and tested. The chapters two, three and four analyse the problems involved in rms measurement and present a comparative study of rms computing techniques and devices. The fifth chapter gives the details of the developed rms detector that permits wave-form-error free rms measurement. The sixth chapter, enumerates the the highlights of the thesis and suggests a list of future projects
Resumo:
This thesis investigated the potential use of Linear Predictive Coding in speech communication applications. A Modified Block Adaptive Predictive Coder is developed, which reduces the computational burden and complexity without sacrificing the speech quality, as compared to the conventional adaptive predictive coding (APC) system. For this, changes in the evaluation methods have been evolved. This method is as different from the usual APC system in that the difference between the true and the predicted value is not transmitted. This allows the replacement of the high order predictor in the transmitter section of a predictive coding system, by a simple delay unit, which makes the transmitter quite simple. Also, the block length used in the processing of the speech signal is adjusted relative to the pitch period of the signal being processed rather than choosing a constant length as hitherto done by other researchers. The efficiency of the newly proposed coder has been supported with results of computer simulation using real speech data. Three methods for voiced/unvoiced/silent/transition classification have been presented. The first one is based on energy, zerocrossing rate and the periodicity of the waveform. The second method uses normalised correlation coefficient as the main parameter, while the third method utilizes a pitch-dependent correlation factor. The third algorithm which gives the minimum error probability has been chosen in a later chapter to design the modified coder The thesis also presents a comparazive study beh-cm the autocorrelation and the covariance methods used in the evaluaiicn of the predictor parameters. It has been proved that the azztocorrelation method is superior to the covariance method with respect to the filter stabf-it)‘ and also in an SNR sense, though the increase in gain is only small. The Modified Block Adaptive Coder applies a switching from pitch precitzion to spectrum prediction when the speech segment changes from a voiced or transition region to an unvoiced region. The experiments cont;-:ted in coding, transmission and simulation, used speech samples from .\£=_‘ajr2_1a:r1 and English phrases. Proposal for a speaker reecgnifion syste: and a phoneme identification system has also been outlized towards the end of the thesis.
Resumo:
This paper discusses the implementation details of a child friendly, good quality, English text-to-speech (TTS) system that is phoneme-based, concatenative, easy to set up and use with little memory. Direct waveform concatenation and linear prediction coding (LPC) are used. Most existing TTS systems are unit-selection based, which use standard speech databases available in neutral adult voices.Here reduced memory is achieved by the concatenation of phonemes and by replacing phonetic wave files with their LPC coefficients. Linguistic analysis was used to reduce the algorithmic complexity instead of signal processing techniques. Sufficient degree of customization and generalization catering to the needs of the child user had been included through the provision for vocabulary and voice selection to suit the requisites of the child. Prosody had also been incorporated. This inexpensive TTS systemwas implemented inMATLAB, with the synthesis presented by means of a graphical user interface (GUI), thus making it child friendly. This can be used not only as an interesting language learning aid for the normal child but it also serves as a speech aid to the vocally disabled child. The quality of the synthesized speech was evaluated using the mean opinion score (MOS).
Resumo:
Salient pole brushless alternators coupled to IC engines are extensively used as stand-by power supply units for meeting in- dustrial power demands. Design of such generators demands high power to weight ratio, high e ciency and low cost per KVA out- put. Moreover, the performance characteristics of such machines like voltage regulation and short circuit ratio (SCR) are critical when these machines are put into parallel operation and alterna- tors for critical applications like defence and aerospace demand very low harmonic content in the output voltage. While designing such alternators, accurate prediction of machine characteristics, including total harmonic distortion (THD) is essential to mini- mize development cost and time. Total harmonic distortion in the output voltage of alternators should be as low as possible especially when powering very sophis- ticated and critical applications. The output voltage waveform of a practical AC generator is replica of the space distribution of the ux density in the air gap and several factors such as shape of the rotor pole face, core saturation, slotting and style of coil disposition make the realization of a sinusoidal air gap ux wave impossible. These ux harmonics introduce undesirable e ects on the alternator performance like high neutral current due to triplen harmonics, voltage distortion, noise, vibration, excessive heating and also extra losses resulting in poor e ciency, which in turn necessitate de-rating of the machine especially when connected to non-linear loads. As an important control unit of brushless alternator, the excitation system and its dynamic performance has a direct impact on alternator's stability and reliability. The thesis explores design and implementation of an excitation i system utilizing third harmonic ux in the air gap of brushless al- ternators, using an additional auxiliary winding, wound for 1=3rd pole pitch, embedded into the stator slots and electrically iso- lated from the main winding. In the third harmonic excitation system, the combined e ect of two auxiliary windings, one with 2=3rd pitch and another third harmonic winding with 1=3rd pitch, are used to ensure good voltage regulation without an electronic automatic voltage regulator (AVR) and also reduces the total harmonic content in the output voltage, cost e ectively. The design of the third harmonic winding by analytic methods demands accurate calculation of third harmonic ux density in the air gap of the machine. However, precise estimation of the amplitude of third harmonic ux in the air gap of a machine by conventional design procedures is di cult due to complex geome- try of the machine and non-linear characteristics of the magnetic materials. As such, prediction of the eld parameters by conven- tional design methods is unreliable and hence virtual prototyping of the machine is done to enable accurate design of the third har- monic excitation system. In the design and development cycle of electrical machines, it is recognized that the use of analytical and experimental methods followed by expensive and in exible prototyping is time consum- ing and no longer cost e ective. Due to advancements in com- putational capabilities over recent years, nite element method (FEM) based virtual prototyping has become an attractive al- ternative to well established semi-analytical and empirical design methods as well as to the still popular trial and error approach followed by the costly and time consuming prototyping. Hence, by virtually prototyping the alternator using FEM, the important performance characteristics of the machine are predicted. Design of third harmonic excitation system is done with the help of results obtained from virtual prototype of the machine. Third harmonic excitation (THE) system is implemented in a 45 KVA ii experimental machine and experiments are conducted to validate the simulation results. Simulation and experimental results show that by utilizing third harmonic ux in the air gap of the ma- chine for excitation purposes during loaded conditions, triplen harmonic content in the output phase voltage is signi cantly re- duced. The prototype machine with third harmonic excitation system designed and developed based on FEM analysis proved to be economical due to its simplicity and has the added advan- tage of reduced harmonics in the output phase voltage.
Resumo:
The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification
Resumo:
El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.
Resumo:
Introducción: La simpatectomía es el tratamiento de la hiperhidrosis palmar y consiste en denervación simpática de miembros superiores que produce un efecto en el flujo sanguíneo al impactar la respuesta vasoconstrictora. El cambio en el flujo sanguíneo se puede evaluar a través de la onda fotopletismográfica. Metodología: Se realizaron 2 sesiones (presimpatectomía y postsimpatectomía) de 10 minutos en cada miembro superior en 28 pacientes obteniendo 79 señales fotopletismográficas distribuidas así: 37 presimpatectomía y 42 señales postsimpatectomía. De cada señal se analizó 1.5 minutos donde se tienen 80 ondas de fotopletismografía y se miden 6 variables: 1. Componente AC (componente pulsátil), 2. Componente DC (componente no pulsátil), 3. Relación entre AC/DC (índice de perfusión), 4. Area bajo la curva (AUC), 5. Tiempo entre el inicio de la onda y pico sistólico (T_DA) y 6. Tiempo entre cada onda de pulso (T_DD). Resultados: Aumentó 120% el componente AC y disminuyó 78% en DC del miembro superior derecho (MSD) con 99% de confiabilidad (p<0.001) entre presimpatectomía (n=18) y postsimpatectomía (n=21). AC/DC aumentó 55% con 95% de confiabilidad entre presimpatectomía (n=19) y postsimpatectomía (n=21) en el miembro superior izquierdo (p<0.05). No se encontró diferencia para T_DA, T_DD ni AUC. Discusión y Conclusión: La simpatectomía en pacientes con hiperhidrosis palmar produce un cambio en el flujo sanguíneo de los miembros superiores evidenciado por los cambios en el componente no pulsátil (DC) y pulsátil (AC) que es secundario a la vasodilatación consecuencia del bloqueo simpático por la denervación quirúrgica de los ganglios simpáticos torácicos.
Resumo:
El ductus venoso refleja el ciclo cardiaco, pero actualmente no se conoce como se comporta cada onda del ductus venoso en los diferentes grupos de cardiopatías congénitas. Se pretende evaluar la importancia de la morfología de las ondas del ductus venoso en el diagnóstico de los diferentes tipos de cardiopatías congénita, teniendo en cuenta las pacientes atendidas en la Unidad De Medicina Materno Fetal de la clínica Colombia entre enero 2012 y julio de 2014.
Resumo:
This thesis proposes a framework for identifying the root-cause of a voltage disturbance, as well as, its source location (upstream/downstream) from the monitoring place. The framework works with three-phase voltage and current waveforms collected in radial distribution networks without distributed generation. Real-world and synthetic waveforms are used to test it. The framework involves features that are conceived based on electrical principles, and assuming some hypothesis on the analyzed phenomena. Features considered are based on waveforms and timestamp information. Multivariate analysis of variance and rule induction algorithms are applied to assess the amount of meaningful information explained by each feature, according to the root-cause of the disturbance and its source location. The obtained classification rates show that the proposed framework could be used for automatic diagnosis of voltage disturbances collected in radial distribution networks. Furthermore, the diagnostic results can be subsequently used for supporting power network operation, maintenance and planning.
Resumo:
We have previously placed the solar contribution to recent global warming in context using observations and without recourse to climate models. It was shown that all solar forcings of climate have declined since 1987. The present paper extends that analysis to include the effects of the various time constants with which the Earth’s climate system might react to solar forcing. The solar input waveform over the past 100 years is defined using observed and inferred galactic cosmic ray fluxes, valid for either a direct effect of cosmic rays on climate or an effect via their known correlation with total solar irradiance (TSI), or for a combination of the two. The implications, and the relative merits, of the various TSI composite data series are discussed and independent tests reveal that the PMOD composite used in our previous paper is the most realistic. Use of the ACRIM composite, which shows a rise in TSI over recent decades, is shown to be inconsistent with most published evidence for solar influences on pre-industrial climate. The conclusions of our previous paper, that solar forcing has declined over the past 20 years while surface air temperatures have continued to rise, are shown to apply for the full range of potential time constants for the climate response to the variations in the solar forcings.
Resumo:
A multivariate fit to the variation in global mean surface air temperature anomaly over the past half century is presented. The fit procedure allows for the effect of response time on the waveform, amplitude and lag of each radiative forcing input, and each is allowed to have its own time constant. It is shown that the contribution of solar variability to the temperature trend since 1987 is small and downward; the best estimate is -1.3% and the 2sigma confidence level sets the uncertainty range of -0.7 to -1.9%. The result is the same if one quantifies the solar variation using galactic cosmic ray fluxes (for which the analysis can be extended back to 1953) or the most accurate total solar irradiance data composite. The rise in the global mean air surface temperatures is predominantly associated with a linear increase that represents the combined effects of changes in anthropogenic well-mixed greenhouse gases and aerosols, although, in recent decades, there is also a considerable contribution by a relative lack of major volcanic eruptions. The best estimate is that the anthropogenic factors contribute 75% of the rise since 1987, with an uncertainty range (set by the 2sigma confidence level using an AR(1) noise model) of 49–160%; thus, the uncertainty is large, but we can state that at least half of the temperature trend comes from the linear term and that this term could explain the entire rise. The results are consistent with the intergovernmental panel on climate change (IPCC) estimates of the changes in radiative forcing (given for 1961–1995) and are here combined with those estimates to find the response times, equilibrium climate sensitivities and pertinent heat capacities (i.e. the depth into the oceans to which a given radiative forcing variation penetrates) of the quasi-periodic (decadal-scale) input forcing variations. As shown by previous studies, the decadal-scale variations do not penetrate as deeply into the oceans as the longer term drifts and have shorter response times. Hence, conclusions about the response to century-scale forcing changes (and hence the associated equilibrium climate sensitivity and the temperature rise commitment) cannot be made from studies of the response to shorter period forcing changes.
Resumo:
Two experiments examine the effect on an immediate recall test of simulating a reverberant auditory environment in which auditory distracters in the form of speech are played to the participants (the 'irrelevant sound effect'). An echo-intensive environment simulated by the addition of reverberation to the speech reduced the extent of 'changes in state' in the irrelevant speech stream by smoothing the profile of the waveform. In both experiments, the reverberant auditory environment produced significantly smaller irrelevant sound distraction effects than an echo-free environment. Results are interpreted in terms of changing-state hypothesis, which states that acoustic content of irrelevant sound, rather than phonology or semantics, determines the extent of the irrelevant sound effect (ISE). Copyright (C) 2007 John Wiley & Sons, Ltd.
Resumo:
Many photovoltaic inverter designs make use of a buck based switched mode power supply (SMPS) to produce a rectified sinusoidal waveform. This waveform is then unfolded by a low frequency switching structure to produce a fully sinusoidal waveform. The Cuk SMPS could offer advantages over the buck in such applications. Unfortunately the Cuk converter is considered to be difficult to control using classical methods. Correct closed loop design is essential for stable operation of Cuk converters. Due to these stability issues, Cuk converter based designs often require stiff low bandwidth control loops. In order to achieve this stable closed loop performance, traditional designs invariably need large, unreliable electrolytic capacitors. In this paper, an inverter with a sliding mode control approach is presented which enables the designer to make use of the Cuk converters advantages, while ameliorating control difficulties. This control method allows the selection of passive components based predominantly on ripple and reliability specifications while requiring only one state reference signal. This allows much smaller, more reliable non-electrolytic capacitors to be used. A prototype inverter has been constructed and results obtained which demonstrate the design flexibility of the Cuk topology when coupled with sliding mode control.