992 resultados para Novel capillary electrophoresis microchip
Resumo:
This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.
Resumo:
The presence of monoethyl carbonate (MEC) in beer and sparkling wine is demonstrated for the first time, as well as the formation of this species in drinks prepared with a distilled beverage and a carbonated soft drink. A capillary electrophoresis (CE) equipment with two capacitively coupled contactless conductivity detector ((CD)-D-4) was used to identify and quantify this species. The concentrations of MEC in samples of lager beer and rum and cola drink were, respectively, 1.2 and 4.1 mmol/l, which agree with the levels of ethanol and CO2 available in these products. Previous results about the kinetics of the reaction suggest that only a small amount of MEC should be formed after the ingredients of a drink are mixed. However, in all three cases (whisky and club soda: rum with cola; gin and tonic water), MEC was quickly formed, which was attributed to the low pH of the drinks. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
This communication reports a promising platform for rapid, simple, direct, and ultrasensitive determination of serotonin. The method is related to integration of vertically aligned single-walled carbon nanotubes (SWCNTs) in electrochemical microfluidic devices. The required microfabrication protocol is simple and fast. In addition, the nanomaterial influenced remarkably the obtained limit-of-detection (LOD) values. Our system achieved a LOD of 0.2 nmol L-1 for serotonin, to the best of our knowledge one of the lowest values reported in the literature.
Resumo:
Many physiological and pathological processes are mediated by the activity of proteins assembled in homo and/or hetero-oligomers. The correct recognition and association of these proteins into a functional complex is a key step determining the fate of the whole pathway. This has led to an increasing interest in selecting molecules able to modulate/inhibit these protein-protein interactions. In particular, our research was focused on Heat Shock Protein 90 (Hsp90), responsible for the activation and maturation and disposition of many client proteins [1], [2] [3]. Circular Dichroism (CD) spectroscopy, Surface Plasmon Resonance (SPR) and Affinity Capillary Electrophoresis (ACE) were used to characterize the Hsp90 target and, furthermore, its inhibition process via C-terminal domain driven by the small molecule Coumermycin A1. Circular Dichroism was used as powerful technique to characterize Hsp90 and its co-chaperone Hop in solution for secondary structure content, stability to different pHs, temperatures and solvents. Furthermore, CD was used to characterize ATP but, unfortunately, we were not able to monitor an interaction between ATP and Hsp90. The utility of SPR technology, on the other hand, arises from the possibility of immobilizing the protein on a chip through its N-terminal domain to later study the interaction with small molecules able to disrupt the Hsp90 dimerization on the C-terminal domain. The protein was attached on SPR chip using the “amine coupling” chemistry so that the C-terminal domain was free to interact with Coumermycin A1. The goal of the experiment was achieved by testing a range of concentrations of the small molecule Coumermycin A1. Despite to the large difference in the molecular weight of the protein (90KDa) and the drug (1110.08 Da), we were able to calculate the affinity constant of the interaction that was found to be 11.2 µm. In order to confirm the binding constant calculated for the Hsp90 on the chip, we decided to use Capillary Electrophoresis to test the Coumermycin binding to Hsp90. First, this technique was conveniently used to characterize the Hsp90 sample in terms of composition and purity. The experimental conditions were settled on two different systems, the bared fused silica and the PVA-coated capillary. We were able to characterize the Hsp90 sample in both systems. Furthermore, we employed an application of capillary electrophoresis, the Affinity Capillary Electrophoresis (ACE), to measure and confirm the binding constant calculated for Coumermycin on Optical Biosensor. We found a KD = 19.45 µM. This result compares favorably with the KD previously obtained on biosensor. This is a promising result for the use of our novel approach to screen new potential inhibitors of Hsp90 C-terminal domain.
Resumo:
The separation of small molecules by capillary electrophoresis is governed by a complex interplay among several physical effects. Until recently, a systematic understanding of how the influence of all of these effects is observed experimentally has remained unclear. The work presented in this thesis involves the use of transient isotachophoretic stacking (tITP) and computer simulation to improve and better understand an in-capillary chemical assay for creatinine. This assay involves the use of electrophoretically mediated micro-analysis (EMMA) to carry out the Jaffé reaction inside a capillary tube. The primary contribution of this work is the elucidation of the role of the length and concentration of the hydroxide plug used to achieve tITP stacking of the product formed by the in-capillary EMMA/Jaffé method. Computer simulation using SIMUL 5.0 predicts that a 3-4 fold gain in sensitivity can be recognized by timing the tITP stacking event such that the Jaffé product peak is at its maximum height as that peak is electrophoresing past the detection window. Overall, the length of the hydroxide plug alters the timing of the stacking event and lower concentration plugs of hydroxide lead to more rapidly occurring tITP stacking events. Also, the inclusion of intentional tITP stacking in the EMMA/Jaffé method improves the sensitivity of the assay, including creatinine concentrations within the normal biological range. Ultimately, improvement in assay sensitivity can be rationally designed by using the length and concentration of the hydroxide plug to engineer the timing of the tITP stacking event such that stacking occurs as the Jaffé product is passing the detection window.
Resumo:
Difficulties in determining composition and sequence of glycosaminoglycans, such as those related to heparin, have limited the investigation of these biologically important molecules. Here, we report methodology, based on matrix-assisted laser desorption ionization MS and capillary electrophoresis, to follow the time course of the enzymatic degradation of heparin-like glycosaminoglycans through the intermediate stages to the end products. MS allows the determination of the molecular weights of the sulfated carbohydrate intermediates and their approximate relative abundances at different time points of the experiment. Capillary electrophoresis subsequently is used to follow more accurately the abundance of the components and also to measure sulfated disaccharides for which MS is not well applicable. For those substrates that produce identical or isomeric intermediates, the reducing end of the carbohydrate chain was converted to the semicarbazone. This conversion increases the molecular weight of all products retaining the reducing terminus by the “mass tag” (in this case 56 Da) and thus distinguishes them from other products. A few picomoles of heparin-derived, sulfated hexa- to decasaccharides of known structure were subjected to heparinase I digestion and analyzed. The results indicate that the enzyme acts primarily exolytically and in a processive mode. The methodology described should be equally useful for other enzymes, including those modified by site-directed mutagenesis, and may lead to the development of an approach to the sequencing of complex glycosaminoglycans.
Resumo:
We report automated DNA sequencing in 16-channel microchips. A microchip prefilled with sieving matrix is aligned on a heating plate affixed to a movable platform. Samples are loaded into sample reservoirs by using an eight-tip pipetting device, and the chip is docked with an array of electrodes in the focal plane of a four-color scanning detection system. Under computer control, high voltage is applied to the appropriate reservoirs in a programmed sequence that injects and separates the DNA samples. An integrated four-color confocal fluorescent detector automatically scans all 16 channels. The system routinely yields more than 450 bases in 15 min in all 16 channels. In the best case using an automated base-calling program, 543 bases have been called at an accuracy of >99%. Separations, including automated chip loading and sample injection, normally are completed in less than 18 min. The advantages of DNA sequencing on capillary electrophoresis chips include uniform signal intensity and tolerance of high DNA template concentration. To understand the fundamentals of these unique features we developed a theoretical treatment of cross-channel chip injection that we call the differential concentration effect. We present experimental evidence consistent with the predictions of the theory.
Resumo:
Neste trabalho são apresentados processos de microfabricação de estruturas contendo microcanais e sistemas de manipulação hidrodinâmica e eletroosmótica de fluídos. Foram desenvolvidos processos de microfabricação utilizando toner sobre poliéster, toner sobre vidro, toner como resiste, além de métodos alternativos de perfuração de lâminas e selagem de microestruturas em vidro, desenvolvimento de microestruturas para eletroforese capilar e espectrometria de massas com ionização por eletronebulização. A caracterização dos materiais e processos permitiu uma ampla visão das potencialidades e alternativas dos processos de microfabricação, tendo sido demonstrado que os dispositivos produzidos em toner-poliéster são quimicamente resistentes às substâncias tipicamente utilizadas em eletroforese capilar. Neste trabalho, um detector condutométrico sem contato foi implementado em microestruturas de toner-poliéster e a separação eletroforética de alguns metais alcalinos é demonstrada. A microestrutura foi projetada no formato padrão em cruz, tendo o canal de separação 22 mm de comprimento, 12 µm de profundidade e largura típica. A cela condutométrica foi construída sobre o canal de separação utilizando-se fita adesiva de cobre (1 mm de largura) como eletrodos. O sinal aplicado na cela foi de 530 kHz e 10 Vpp . A separação de K+, Na+ e Li+ na concentração de 100 µmol L-1 foi efetuada em torno de 0,8 min, utilizando-se 1 kV como potencial de separação. Foram desenvolvidos microchips para análise por espectrometria de massas com introdução de amostra por eletronebulização, sendo determinado cluster do íon cloreto em concentração de 1 mmol L+. Também solução com 1 mmol/L de glucosamina em água/metanol 1: 1 (v/v), sob corrente de 100 nA gerou sinal estável e livre de descarga corona. Utilizando detecção amperométrica, obteve-se eletroferogramas mostrando a separação de iodeto (10 mmol L-1) e ascorbato (40 mmol L-1) em potencial de separação de 4,0 kV (800 V cm-1 potencial de detecção de 0,9 V (vs. Ag/AgCI), injeção com 1,0 kV/1°s, tampão borato de sódio 10 mmol L+ com CTAH 0,2 mmol L-1, pH 9,2. Obteve-se eficiência de 1,6.104 pratos/m e foi possível obter limites de detecção de 500 nmol L-1 (135 amol) e 1,8 µmol L-1 (486 amol) para iodeto e ascorbato, respectivamente. O processo de fabricação utilizando toner como material estrutural para microchips em vidro foi bem estabelecido, assim como os modos de detecção fotométrico e condutométrico foram demonstrados. Foram obtidos eletroferogramas par detecção condutométrica sem contato de solução 200 µmol L-1 de K+, Na+ e U+, em tampão histidina/ácido lático 30 mmol L-1 9:1 (v/v) água:metanol, injeção eletrocinética de 2,0 kV/5,0 s, potencial de separação de 1 kV, 530 kHz de frequência e tensão de 2,0 Vpp. Também foi implementado um sistema de detecção fotométrico para microchip operando em 660 nm, tendo sido utilizado para a detecção de azul de metileno 1,0 mmol L-1 em tampão de corrida de barato de sódio 20 mmol L-1 (pH 9,2), com o detector posicionado a 40 mm do ponto de injeção e com injeção eletrocinética a 2,0 kV por 12 s com picos bem resolvidos em menos de 1 min.
Resumo:
This article describes the use of a conventional CRT monitor as a high voltage power supply for capillary electrophoresis. With this monitor, a 23-kV high voltage with a ripple of 1.32% was observed. The reproducibility of the applied high voltage was evaluated by measuring the standard deviations of peak area and migration time for five consecutive injections of a test mixture containing potassium, sodium, and lithium cations at 50 mmol L-1. The errors were about 2.5% and 0.6% for peak area and migration time, respectively. The maximum current tested was about 180 mA, which covers most capillary electrophoresis applications. This system has been successfully used for several months, maintaining the desired level of performance.
Resumo:
CE-MS has been increasingly used for analysis of a vast array of compounds. This article reviews the different electrophoretic modes, interfaces and mass analyzers that are commonly used in the CE-MS coupling, as well as the technique advantages and performance characteristics. A large compilation of CE-MS applications is also presented. Therefore, this review is both a guide for beginners and a collection of key references for people who are familiar to the technique. Furthermore, this is the first CE-MS review published in a Brazilian journal and marks the installation of the first two commercial CE-MS units in Sao Paulo State.
Resumo:
This work describes CE preconcentration strategies based on the effect of manipulation of the disperse/secondary velocity. Introduced by Terabe et al. in 1984, micellar electrokinetic chromatography is a powerful separation approach that increases the usage of electrokinetic phenomena for the separation of nonionic compounds. The main disadvantage of MEKC is the low concentration sensitivity associated with the limited optical path length for on-capillary photometric detection and the limited volume of sample solution that can be injected. This paper compiles on-line concentration strategies for neutral analytes by sample stacking and sweeping in micellar electrokinetic chromatography.
Resumo:
Capillary electrophoresis has become a well-established and routine-based separation technique. It is based on the differences between charged analyte mobility in aqueous or organic electrolytes. Its major limitation is the sensitivity due to small sample injection volumes and the narrow diameter of the capillaries, especially when UV detection is used. There are a number of ways to increase the concentration sensitivity. This report shows some on-line preconcentration strategies to perform it in free solution capillary electrophoresis that are based on manipulation of the analyte electrophoretic velocity during the sample introduction (stacking, field amplification and transient isotachophoresis).
Resumo:
The interplay between the biocolloidal characteristics (especially size and charge), pH, salt concentration and the thermal energy results in a unique collection of mesoscopic forces of importance to the molecular organization and function in biological systems. By means of Monte Carlo simulations and semi-quantitative analysis in terms of perturbation theory, we describe a general electrostatic mechanism that gives attraction at low electrolyte concentrations. This charge regulation mechanism due to titrating amino acid residues is discussed in a purely electrostatic framework. The complexation data reported here for interaction between a polyelectrolyte chain and the proteins albumin, goat and bovine alpha-lactalbumin, beta-lactoglobulin, insulin, k-casein, lysozyme and pectin methylesterase illustrate the importance of the charge regulation mechanism. Special attention is given to pH congruent to pI where ion-dipole and charge regulation interactions could overcome the repulsive ion-ion interaction. By means of protein mutations, we confirm the importance of the charge regulation mechanism, and quantify when the complexation is dominated either by charge regulation or by the ion-dipole term.
Resumo:
Salbutamol is a bronchodilator whose use is restricted due to its anabolic effects. A flow-based procedure for salbutamol determination based on the inhibition of chemiluminescence of the luminol/hypochlorite system was developed. A flow cell constructed with a liquid-core waveguide was employed to constrain the emitted radiation, minimizing losses during transport to detector. Linear response was observed within 2.5 x 10(-6) and 1.0 x 10(-5) mol L-1 with a detection limit estimated as 1 x 10(-7) mol L-1 at the 99.7% confidence level. The coefficient of variation (n = 20), sampling rate, and luminol consumption per determination were estimated as 2.8%, 164 determinations h(-1), and 50 mu g, respectively. Results for pharmaceutical samples were in agreement with those obtained by reference procedures at the 95% confidence level.
Resumo:
Objectives: To evaluate biomarkers of endothelial dysfunction and oxidative stress in glucose intolerance (GI) compared to overt diabetes (DM2). Design and methods: 140 volunteers including 96 with DM2, 32 with GI and 12 controls (C) were Studied. NO metabolites, NO synthase inhibitors. thiols and N-acetyl-beta-glucosaminidase (NAGase) activity were analyzed by chemiluminescence, capillary electrophoresis, ELISA and colorimetric assay, respectively. Results: (center dot)NO metabolites were higher in GI (NOx: P=0.03 S-nitrosothiols: p=0.001) and DM2 (p=0.006; p=0.0006) groups in relation to group C, while nitrotyrosine was higher only in the DM2 group in comparison 10 the other groups. NAGase activity was elevated in GI (p=0.003) and DM2 (p=0.0004) groups in relation to group C, as well as, ADMA (p=0.01: p=0.003) and GSSG (p=0.01 p=0.002). Conclusions: (center dot)NO metabolites. (center dot)NO synthase inhibitors. thiols and NAGase are biomarkers Suitable to indicate endothelial dysfunction and oxidative stress in the early stages of impaired response to insulin. (c) 2008 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.