957 resultados para Zinc oxide powder


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Compararam-se os efeitos de diferentes fontes e doses de zinco na dieta de ovinos Santa Inês sobre os níveis de zinco plasmático e de fosfatase alcalina. Foram utilizados 40 cordeiros, recém-desmamados, com média de peso de 18,4kg, distribuídos em 10 tratamentos: 1- dieta basal sem suplementação de zinco; 2- dieta basal + 200mg de Zn/kg de MS na forma de óxido de zinco; 3- dieta basal + 400mg de Zn/kg de MS na forma de óxido de zinco; 4- dieta basal + 600mg de Zn/kg de MS na forma de óxido de zinco; 5- dieta basal + 200mg de Zn/kg de MS na forma de zinco aminoácido; 6- dieta basal + 400mg de Zn/kg de MS na forma de zinco aminoácido; 7- dieta basal + 600mg de Zn/kg de MS na forma de zinco aminoácido; 8- dieta basal + 200mg de Zn/kg de MS na forma de zinco proteinato; 9- dieta basal + 400mg de Zn/kg de MS na forma de zinco proteinato; 10- dieta basal + 600mg de Zn/kg de MS na forma de zinco proteinato. A cada 28 dias, os animais foram pesados e tiveram seu sangue colhido para análise de zinco (Zn), análise de fosfatase alcalina e análises de imunoglobulinas G (IgG) e M (IgM). No final do experimento, foram coletadas amostras de fígado para estudo dos níveis de zinco hepático. Não houve diferença entre tratamentos nos níveis de fosfatase alcalina e de zinco hepático, e no ganho de peso (P>0,05), mas houve diferença (P<0,05) nos níveis de Zn plasmático e nos níveis de IgG e IgM. Baseando-se no acúmulo no fígado, a estimativa da biodisponibilidade de zinco, por intermédio das equações de regressão, mostrou que as fontes orgânicas e inorgânicas de zinco não diferiram entre si.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Foram conduzidos dois experimentos para avaliar fontes orgânicas e inorgânicas de zinco e cobre nas dietas e seus efeitos no desempenho de leitões desmamados aos 21 dias de idade. Em cada experimento, foram utilizados 90 leitões em delineamento experimental de blocos ao acaso, com cinco dietas, seis repetições e três animais por parcela. As dietas utilizadas nos experimentos 1 e 2 continham 120 ppm de zinco e 10 ppm de cobre na forma de sulfato. No experimento 1, foram suplementadas com 0, 300, 600 e 900 ppm de zinco na forma orgânica ou 2.400 ppm na forma de óxido (ZnO) e, no experimento 2, com 0, 50, 100 e 150 ppm de cobre na forma orgânica ou 240 ppm de cobre na forma de sulfato (CuSO4 H2O). No experimento 1, os níveis de zinco de fonte orgânica tiveram efeito linear no consumo de ração e no ganho de peso nos períodos de 0 a 15 dias e de 0 a 21 dias pós-desmame. O ganho de peso nas fases de 0 a 35 dias e de 0 a 42 dias pós-desmame e o consumo de ração dos leitões que receberam a dieta com 900 ppm de zinco de fonte orgânica não diferiram dos valores observados naqueles que receberam a dieta com 2.400 ppm de zinco na forma inorgânica. A suplementação da dieta com zinco na forma orgânica (900 ppm) ou inorgânica (2.400 ppm) aumentou o consumo de ração e o ganho de peso de leitões nas primeiras três semanas após o desmame. A suplementação da dieta com 2.400 ppm de zinco na forma inorgânica reduziu a incidência de diarreia nas primeiras três semanas pós-desmame. No experimento 2, os níveis de cobre de fonte orgânica tiveram efeito quadrático no consumo de ração dos leitões nos períodos de 0 a 31 e de 0 a 40 dias pós-desmame. A suplementação da dieta com cobre, tanto de fonte orgânica (90 ppm) como inorgânica (240 ppm), aumenta o consumo de ração e o ganho de peso de leitões nos primeiros 40 dias pós-desmame.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Using ab initio total energy calculations, we show that bilayer systems of ZnO nanoribbons, (ZnO)(2)NR, doped with Co atoms exhibit a piezomagnetic behavior. We find the formation of energetically stable zigzag chains of Co atoms along the edge sites of (ZnO)(2)NR's, Co(Zn(chain))-(ZnO)(2)NR. At the ground state, the antiferromagnetic and the ferromagnetic states are very close in energy, whereas upon longitudinal stretch, parallel to the nanoribbon growth direction, it becomes ferromagnetic. Further electronic structure calculations indicate that not only the magnetic state but also the electronic structure of CoZn(chain)-(ZnO)(2)NR can be tuned by the mechanical stretch. In this case, we find that stretched NR's exhibit dispersive unpaired electronic states within the (ZnO)(2)NR band gap.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Bulk Zn(1-x)Co(x)O samples were synthesized via standard solid-state reaction route with different Co molar concentrations up to 21%. A detailed microstructural analysis was carried out to investigate alternative sources of ferromagnetism, such as secondary phases and nanocrystals embedded in the bulk material. Conjugating different techniques we confirmed the Zn replacement by Co ions in the wurtzite ZnO structure, which retains, however, a high crystalline quality. No segregated secondary phases neither Co-rich nanocrystals were detected. Superconducting quantum interference device magnetometry demonstrates a paramagnetic Curie-Weiss behavior with antiferromagnetic interactions. We discuss the observed room temperature paramagnetism of our samples considering the current models for the magnetic properties of diluted magnetic semiconductors. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3459885]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The skin is a large and accessible area of the body, offering the possibility to be used as an alternative route for drug delivery. In the last few years strong progress has been made on the developing of nanoparticulate systems for specific applications. The interaction of such small particles with human skin and their possible penetration attracted some interest from toxicological as well as from drug delivery perspectives. As size is assumed to play a key role, the aim of the present work was to investigate the penetration profile of very small model particles (similar to 4 nm) into excised human skin under conditions chosen to mimic the in vivo situation. Possible application procedures such as massaging the formulation (5 to 10 minutes) were analyzed by non-invasive multiphoton- and confocal laser scanning microscopy (MPM, CLSM). Furthermore, the application on damaged skin was taken into account by deliberately removing parts of the stratum corneum. Although it was clearly observed that the mechanical actions affected the distribution pattern of the QDs on the skin surface, there was no evidence of penetration into the skin in all cases tested. QDs could be found in deeper layers only after massaging of damaged skin for 10 min. Taking these data into account, obtained on the gold standard human skin, the potential applications of nanoparticulate systems to act as carrier delivering drugs into intact skin might be limited and are only of interest for partly damaged skin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The susceptibility of cattle and buffalos to chronic copper poisoning (CCP) was compared by using cattle (n = 10) and buffalo (n = 10) steers distributed into two copper supplemented (n = 6) and two control (n = 4) groups. Supplemented animals received 2 mg copper (Cu)/kg body weight daily for one week, with an additional 2 mg weekly until the end of the experiment (day 105). Three liver biopsies (day 0, 45, and 105) were obtained for mineral analyses; clinical examinations and blood samples were obtained every 15 days. Three supplemented cattle and two buffalos with typical manifestations of CCP died. There were no differences in the frequency of mortality between cattle and buffalos; hepatic copper concentration was higher in cattle than buffalos. These findings suggest that buffalos and cattle might be equally susceptible to CCP. However, buffalos accumulate less liver copper than cattle and have a lower threshold of hepatic Cu accumulation, which leads to clinical manifestation of CCP. (c) 2009 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The present randomized, controlled prospective study evaluated the histomorphological response of human dental pulps capped with two grey mineral trioxide aggregate (MTA) compounds. Pulp exposures were performed on the occlusal floor of 40 human permanent pre-molars. The pulp was capped either with ProRoot (Dentsply) or MTA-Angelus (Angelus) and restored with zinc oxide eugenol cement. After 30 and 60 days, teeth were extracted and processed for histological examination and the effects on the pulp were scored. The data were subjected to Kruskal-Wallis and Conover tests (alpha = 0.05). In five out of the 40 teeth bacteria were present in pulp tissue. No significant difference was observed between the two materials (P > 0.05) in terms of overall histological features (hard tissue bridge, inflammatory response, giant cells and particles of capping materials). Overall, 94% and 88% of the specimens capped with MTA-Angelus and ProRoot, respectively, showed either total or partial hard tissue bridge formation (P > 0.05). Both commercial materials ProRoot (Dentsply) and MTA-Angelus (Angelus) produced similar responses in the pulp when used for pulp capping in intact, caries-free teeth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Methods: Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 degrees C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, alpha = 0.05). Results: None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. Conclusions: ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. (I Endod 2010;36:1870-1873)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: To evaluate calcium ion release and pH of Sealer 26 (S26) (Dentsply, Rio de Janeiro, RJ, Brazil), white mineral trioxide aggregate (MTA), Endo CPM Sealer (CPM1) (EGEO SRL Bajo licencia MTM Argentina SA, Buenos Aires, Argentina), Endo CPM Sealer in a thicker consistency (CPM 2), and zinc oxide and eugenol cement (ZOE). Methods: Material samples (n = 10) were placed in polyethylene tubes and immersed in 10 mL of distilled water. After 3, 6,12,24, and 48 hours and 7,14, and 28 days, the water pH was determined with a pH meter, and calcium release was assessed by atomic absorption spectrophotometry. An empty tube was used as the control group. Results: The control group presented a pH value of 6.9 at all studied periods and did not show the presence of calcium ion. S26 presented greater hydroxyl ion release up to 12 hours (p < 0.05). From 24 hours until 28 days, S26, MTA, CPM1, and CPM2 had similar results. in ail periods, ZOE presented the lowest hydroxyl ion release. CPM1, followed by CPM2, released the most calcium ions until 24 hours (p < 0.05). Between 48 hours and 7 days, CPM1 and CPM2 had the highest release. A greater calcium ion release was observed for CPM2, followed by CPM1 at 14 days and for S26, CPM1, and CPM2 at 28 days. ZOE released the least calcium ions in all periods. Conclusion: Sealer 26, MTA, and Endo CPM sealer at normal or thicker consistency release hydroxyl and calcium ions. Endo CPM sealer may be an alternative as root-end filling material. (J Endod 2009;35:1418-1421)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study evaluated the radiopacity of Portland cement associated with the following radiopacifying agents: bismuth oxide, zinc oxide, lead oxide, bismuth subnitrate, bismuth carbonate, barium sulfate, iodoform, calcium tungstate, and zirconium oxide. A ratio of 20% radiopacifier and 80% white Portland cement by weight was used for analysis. Pure Portland cement and dentin served as controls. Cement/radiopacifier and dentin disc-shaped specimens were fabricated, and radiopacity testing was performed according to the ISO 6876/2001 standard for dental root sealing materials. Using Insight occlusal films, the specimens were radiographed near to a graduated aluminum stepwedge varying from 2 to 16 mm in thickness. The radiographs were digitized and radiopacity compared with the aluminum stepwedge using Digora software (Orion Corporation Soredex, Helsinki, Finland). The radiographic density data were converted into mmAl and analyzed statistically by analysis of variance and Tukey-Kramer test (alpha = 0.05). The radiopacity of pure Portland cement was significantly lower (p < 0.05) than that of dentin, whereas all cement/radiopacifier mixtures were significantly more radiopaque than dentin and Portland cement alone (p < 0.05). Portland cement/bismuth oxide and Portland cement/lead oxide presented the highest radiopacity values and differed significantly from the other materials (p < 0.05), whereas Portland cement/zinc oxide presented the lowest radiopacity values of all mixtures (p < 0.05). All tested substances presented higher radiopacity than that of dentin and may potentially be added to the Portland cement as radiopacifying agents. However, the possible interference of the radiopacifiers with the setting chemistry, biocompatibility, and physical properties of the Portland cement should be further investigated before any clinical recommendation can be done. (J Endod 2009,35:737-740)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 62-year-old man was referred for routine treatment of hyperplasia of the mucosa in the anterior lower jaw. An oroantral fistula was detected in the right superior alveolar ridge. The patient had no complaints. Plain radiographs showed a radiopaque foreign body in the posterior region associated with opacification of the maxillary sinus. Computed tomography showed the same hyperdense foreign body located in the posterior lower part of the sinus and an abnormal soft tissue mass in the entire right maxillary sinus. When asked about sinusitis, the patient mentioned occasional episodes of pus taste and intermittent crises of headache lasting for one week. The patient has been edentulous for 20 years. Sinus debridement was performed and the oroantral fistula was closed. The clinical suspicion of the presence of zinc oxide-eugenol paste was confirmed by microscopical and chemical analysis. After 6 months of follow-up, the fistula continued to be closed and sinusitis did not recur. This clinical case of maxillary chronic sinusitis illustrates a different odontogenic origin.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the radiopacity of calcium aluminate cement (Endo Binder) with 3 different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) in comparison with gray mineral trioxide aggregate (GMTA), white MTA, and dental structures (enamel and dentin). Methods: Eighteen test specimens of each cement with thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm (n = 3) were made by using a stainless steel matrix and were adapted to a standardizing device (8 x 7 cm) with a graduated aluminum stepwedge varying from 2.0-16.0 mm in thickness. To compare the radiopacity of the cements with that of dental structures, slices of first molars with a thickness increasing from 0.5-3.0 mm were obtained and placed on the standardizing device. One occlusal radiograph for each tested cement was taken, with exposure time of 0.1 seconds and focus-film distance of 20 cm. Films were processed in an automatic device, and the mean radiopacity values were obtained by using a photodensitometer. Results: Mean values showed that the thicker the specimen was, the greater was its radiopacity. Only EndoBinder + bismuth oxide (EBBO) and GMTA demonstrated radiopacity values greater than 3.0 mm of the aluminum scale for all thicknesses. When zinc oxide was used as radiopacifier agent, EndoBinder only reached the desired radiopacity with a thickness of 2.0 mm, and with zirconium oxide it was 2.5 mm. Conclusions: Bismuth oxide was the most efficient radiopacifier for EndoBinder, providing adequate radiopacity in all studied thicknesses, as recommended by ISO 6876, being similar to GMTA. (J Endod 2011;37: 67-71)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mestrado em Engenharia Química

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ZnO films doped with vanadium (ZnO:V) have been prepared by dc reactive magnetron sputtering technique at different substrate temperatures (RT–500 C). The effects of the substrate temperature on ZnO:V films properties have been studied. XRD measurements show that only ZnO polycrystalline structure has been obtained, no V2O5 or VO2 crystal phase can be observed. It has been found that the film prepared at low substrate temperature has a preferred orientation along the (002) direction. As the substrate temperature is increased, the (002) peak intensity decreases. When the substrate temperature reaches the 500 C, the film shows a random orientation. SEM measurements show a clear formation of the nano-grains in the sample surface when the substrate temperature is higher than 400 C. The optical properties of the films have been studied by measuring the specular transmittance. The refractive index has been calculated by fitting the transmittance spectra using OJL model combined with harmonic oscillator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Advanced Materials, Vol. 17, nº 5