Radiopacity Evaluation of Calcium Aluminate Cement Containing Different Radiopacifying Agents


Autoria(s): AGUILAI, Fabian Gamero; GARCIA, Lucas da Fonseca Roberti; ROSSETTO, Hebert Luis; PARDINI, Luiz Carlos; PIRES-DE-SOUZA, Fernando de Carvalho Panzeri
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2011

Resumo

Introduction: The aim of this study was to evaluate the radiopacity of calcium aluminate cement (Endo Binder) with 3 different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) in comparison with gray mineral trioxide aggregate (GMTA), white MTA, and dental structures (enamel and dentin). Methods: Eighteen test specimens of each cement with thicknesses of 0.5, 1.0, 1.5, 2.0, 2.5, and 3.0 mm (n = 3) were made by using a stainless steel matrix and were adapted to a standardizing device (8 x 7 cm) with a graduated aluminum stepwedge varying from 2.0-16.0 mm in thickness. To compare the radiopacity of the cements with that of dental structures, slices of first molars with a thickness increasing from 0.5-3.0 mm were obtained and placed on the standardizing device. One occlusal radiograph for each tested cement was taken, with exposure time of 0.1 seconds and focus-film distance of 20 cm. Films were processed in an automatic device, and the mean radiopacity values were obtained by using a photodensitometer. Results: Mean values showed that the thicker the specimen was, the greater was its radiopacity. Only EndoBinder + bismuth oxide (EBBO) and GMTA demonstrated radiopacity values greater than 3.0 mm of the aluminum scale for all thicknesses. When zinc oxide was used as radiopacifier agent, EndoBinder only reached the desired radiopacity with a thickness of 2.0 mm, and with zirconium oxide it was 2.5 mm. Conclusions: Bismuth oxide was the most efficient radiopacifier for EndoBinder, providing adequate radiopacity in all studied thicknesses, as recommended by ISO 6876, being similar to GMTA. (J Endod 2011;37: 67-71)

Identificador

JOURNAL OF ENDODONTICS, v.37, n.1, p.67-71, 2011

0099-2399

http://producao.usp.br/handle/BDPI/26349

10.1016/j.joen.2010.10.001

http://dx.doi.org/10.1016/j.joen.2010.10.001

Idioma(s)

eng

Publicador

ELSEVIER SCIENCE INC

Relação

Journal of Endodontics

Direitos

restrictedAccess

Copyright ELSEVIER SCIENCE INC

Palavras-Chave #Calcium aluminate cement #mineral trioxide aggregate #optical density #radiopacity #MINERAL TRIOXIDE AGGREGATE #END FILLING MATERIAL #PORTLAND-CEMENT #PHYSICAL-PROPERTIES #ROOT RESORPTION #MTA #WHITE #APEXIFICATION #MICROLEAKAGE #REPAIR #Dentistry, Oral Surgery & Medicine
Tipo

article

original article

publishedVersion