893 resultados para Simplicity
Resumo:
The operation of generalized Marx-type solid-state bipolar modulators is discussed and compared with simplified Marx-derived circuits, to evaluate their capability to deal with various load conditions. A comparative analysis on the number of switches per cell, fiber optic trigger count, losses, and switch hold-off voltages has been made. A circuit topology is obtained as a compromise in terms of operating performance, trigger simplicity, and switching losses. A five-stage laboratory prototype of this circuit has been assembled using 1200 V insulated gate bipolar transistors (IGBTs) and diodes, operating with 1000 V dc input voltage and 1 kHz frequency, giving 5 kV bipolar pulses, with 2.5 mu s pulse width and 5 mu s relaxation time into resistive, capacitive, and inductive loads.
Resumo:
Os programas de melhoria contínua dos processos são cada vez mais a aposta das empresas para fazer face ao mercado. Através da implementação destes programas é possível conferir simplicidade e padronização aos processos e consequentemente reduzir os custos com desperdícios internos relacionados com a qualidade dos mesmos. As ferramentas de melhoria da qualidade e as ferramentas associadas ao Lean Thinking representam um pilar importante no sucesso de qualquer programa de melhoria contínua dos processos. Estas ferramentas constituem meios úteis na análise, controlo, organização de dados importantes para a correta tomada de decisão nas organizações. O presente projeto tem como principal objetivo a conceção e implementação de um programa de melhoria da qualidade na Eurico Ferreira, S.A., tendo por base a avaliação da satisfação do cliente e a aplicação dos 5S. Neste contexto, o trabalho teve como fundamentação teórica a Gestão da Qualidade, Lean Thinking e algumas ferramentas de ambas as matérias. Posteriormente foi selecionada a área de negócio da empresa a abordar. Após a seleção, realizou-se um diagnóstico inicial do processo identificando os diversos pontos de melhoria onde foram aplicadas algumas ferramentas do Lean Thinking, nomeadamente o Value Stream Mapping e a metodologia 5S. Com a primeira foi possível construir um mapa do estado atual do processo, no qual estavam representados todos os intervenientes assim como o fluxo de materiais e de informação ao longo do processo. A metodologia 5S permitiu atuar sobre os desperdícios, identificando e implementando diversas melhorias no processo. Concluiu-se que a implementação das ferramentas contribuiu eficientemente para a melhoria contínua da qualidade nos processos, tendo sido decisão da coordenação alargar o âmbito do projeto aos restantes armazéns do centro logístico da empresa. Pode afirmar-se com recurso à satisfação do cliente expressa através da evolução favorável do Service-level agreement que as ferramentas implementadas têm gerado resultados muito positivos no curto prazo.
Resumo:
We have evaluated the sensitivity of the classical blood subinoculation method, modified through cyclophosphamide treatment of transferred mice, for the detection of occult parasitaemias in Trypanosoma cruzi chronically infected mice. Besides its simplicity, the method was shown to be highly sensitive for both the "chronic" phase parasites (99% of chronic cases were shown to harbour occult parasitaemias) and for the acute phase parasites (T. cruzi could be detected in 53.8% of animals transferred with one Y strain parasite and in 20% of animals transferred with one CL strain parasite). Using acute phase bloodforms, the assay proved to be more sensitive than conventional subinoculation when dealing with the CL, but not the Y strain of the parasite. With the help of this parasite detection tool, we have studied during a one year period, the evolution of subpatent parasitaemias in a group of mice which survived through chemotherapy from lethal acute phase of T. cruzi infection. Cyclophosphamide transfer assay revealed occult parasitaemias in 100% of the chronic animals, nevertheless, continuous and discontinuous patterns of positivity were observed.
Resumo:
Trabalho de Projeto submetido à Escola Superior de Teatro e Cinema para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Desenvolvimento do Projeto Cinematográfico - especialização em Dramaturgia e Realização.
Resumo:
Trabalho de projeto apresentado à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Publicidade e Marketing.
Resumo:
The application of mathematical methods and computer algorithms in the analysis of economic and financial data series aims to give empirical descriptions of the hidden relations between many complex or unknown variables and systems. This strategy overcomes the requirement for building models based on a set of ‘fundamental laws’, which is the paradigm for studying phenomena usual in physics and engineering. In spite of this shortcut, the fact is that financial series demonstrate to be hard to tackle, involving complex memory effects and a apparently chaotic behaviour. Several measures for describing these objects were adopted by market agents, but, due to their simplicity, they are not capable to cope with the diversity and complexity embedded in the data. Therefore, it is important to propose new measures that, on one hand, are highly interpretable by standard personal but, on the other hand, are capable of capturing a significant part of the dynamical effects.
Resumo:
Relatório de Estágio para obtenção do grau de Mestre em Engenharia Civil na Área de Especialização em Estruturas
Resumo:
Mestrado em Engenharia Mecânica
Resumo:
A Dot enzyme-linked immunosorbent assay (Dot-ELISA) was standardized and evaluated for the serodiagnosis of human toxoplasmosis. Out of 538 serum samples tested by the immunofluorescence test for toxoplasmosis (IFAT-IgG) as reference test, 183 (34%) were positive at cut off 1:16 and 192 (36%) were positive for Dot-ELISA-IgG at cut-off 1:256. For Dot-ELISA, co-positivity was 0.94, co-negativity 0.94 and concordance 0.88 in relation to IFAT-IgG. These results suggest the usefulness of Dot-ELISA (cut-off titer of 1:256) for the serodiagnosis of human toxoplasmosis. The main advantage of this technique is simplicity, positive test can be visually identified (colored precipitate). It does not require a special equipment and it can be used as a qualitative test to screen large numbers of samples or as a quantitative assay to determine end-point titration of individual sera.
Resumo:
Neste relatório de estágio, procurei redigir tudo aquilo que vivi no decorrer do período do estágio profissional. Assim, inicialmente fiz um enquadramento da entidade que me acolheu, bem como uma breve descrição do contrato no qual estive especificamente inserido. Foi efetuada uma descrição detalhada dos conceitos de manutenção preventiva e correctiva adaptadas ao contrato em questão e de acordo com um plano de manutenção específico dedicado à vertente da construção civil. Neste sentido, foram detalhadas as várias tipologias de infraestruturas fixas a manter, nomeadamente as grandes áreas dos edifícios, obras de arte, túneis ou muros de suporte e contenções, descrevendo os procedimentos de manutenção preventiva e corretiva associados a cada tipologia de infraestrutura. São apresentados vários gráficos demonstrativos das ações de manutenção preventiva e corretiva por infraestrutura tipo, bem como alguns exemplos de intervenções de caracter corretivo efetuadas no decorrer do período do estágio profissional. Por fim, é apresentada uma conclusão daquilo que foi um período de aprendizagem importantíssimo no início da minha vida profissional ligada à área da construção civil.
Resumo:
Simple and rapid latex-based diagnostic tests have been used for detecting specific antigens or antibodies in several diseases. In this article, we present the preliminary results obtained with a latex agglutination test (LAT) for diagnosing neurocysticercosis by detection of antibodies in CSF. A total of 43 CSF samples were assayed by the LAT: 19 CSF samples from patients with neurocysticercosis and 24 CSF samples from patients with other neurologic disorders (neurosyphilis, n = 8; neurotoxoplasmosis, n = 3; viral meningitis, n = 4, chronic headache, n = 9). The LAT exhibited 89.5% sensitivity and 75% specificity. The use of LAT seems to be an additional approach for the screening of neurocysticercosis with advantage of simplicity and rapidity. Further studies could be performed using purified antigens and serum samples.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
A new immunosensor is presented for human chorionic gonadotropin (hCG), made by electrodepositing chitosan/gold-nanoparticles over graphene screen-printed electrode (SPE). The antibody was covalently bound to CS via its Fc-terminal. The assembly was controlled by electrochemical Impedance Spectroscopy (EIS) and followed by Fourier Transformed Infrared (FTIR). The hCG-immunosensor displayed linear response against the logarithm-hCG concentration for 0.1–25 ng/mL with limit of detection of 0.016 ng/mL. High selectivity was observed in blank urine and successful detection of hCG was also achieved in spiked samples of real urine from pregnant woman. The immunosensor showed good detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
Chemical sensors and biosensors are widely used to detect various kinds of protein target biomolecules. Molecularly Imprinted Polymers (MIPs) have raised great interest in this area, because these act as antibody-like recognition materials, with high affinity to the template molecule. Compared to natural antibodies, these are also of lower cost and higher stability. There are different types of supports used to carry MIP materials, mostly of these made of gold, favourably assembled on a Screen Printed Electrode (SPE) strategy. For this work a new kind of support for the sensing layer was developed: conductive paper. This support was made by modifying first cellulose paper with paraffin wax (to make it waterproof), and casting a carbon-ink on it afterwards, to turn it conductive. The SPAM approach previously reported in1 was employed herein to assemble to MIP sensing material on the conductive paper. The selected charged monomers were (vinylbenzyl) trimethlammonium chloride (positive charge) or vinylbenzoic acid (negative charge), used to generate binding positions with single-type charge (positive or negative). The non-specific binding area of the MIP layer was assembled by chronoamperometry-assisted polymerization (at 1 V, for 60, 120 or 180 seconds) of vinylbenzoate, cross-linked with ethylene glycol vinyl ether. The BSA biomolecules lying within the polymeric matrix were removed by Proteinase K action. All preparation stages of the MIP assembly were followed by FTIR, Raman spectroscopy and, electrochemical analysis. In general, the best results were obtained for longer polymerization times and positively charged binding sites (which was consistent with a negatively-charged protein under physiological pH, as BSA). Linear responses against BSA concentration ranged from 0.005 to 100 mg/mL, in PBS buffer standard solutions. The sensor was further calibrated in standard solutions that were prepared in synthetic or real urine, and the analytical response became more sensitive and stable. Compared to the literature, the detection capability of the developed device is better than most of the reported electrodes. Overall, the simplicity, low cost and good analytical performance of the BSA SPE device, prepared with positively charged binding positions, seems a suitable approach for practical application in clinical context. Further studies with real samples are required, as well as gathering with electronic-supporting devices to allow on-site readings.
Resumo:
Sol-gel chemistry allows the immobilization of organic molecules of biological origin on suibtable solid supports, permitting their integration into biosensing devices widening the possibility of local applications. The present work is an application of this principle, where the link between electrical receptor platform and the antibody acting as biorecognition element is made by sol-gel chemistry. The immunosensor design was targeted for carcinoembryonic antigen (CEA), an important biomarker for screening the colorectal cancer, by electrochemical techniques, namely electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SVW). The device displayed linear behavior to CEA in EIS and in SWV assays ranging from 0.50 to 1.5ng/mL, and 0.25 to 1.5ng/mL, respectively. The corresponding detection limits were 0.42 and 0.043 ng/mL. Raman spectroscopy was used to characterize the surface modifications on the conductive platform (FTO glass). Overall, simple sol-gel chemistry was effective at the biosensing design and the presented approach can be a potential method for screening CEA in point-of-care, due to the simplicity of fabrication, short response time and low cost. - See more at: http://www.eurekaselect.com/127192/article#sthash.m1AWhINx.dpuf