278 resultados para Ppv
Resumo:
Later-born siblings of children with autism spectrum disorder (ASD) are considered at biological risk for ASD and the broader autism phenotype. Early screening may detect early signs of ASD and facilitate intervention as soon as possible. This follow-up study revisits and re-examines a second-degree autism screener for children at biological risk of autism, the Parent Observation Early Markers Scale (POEMS, Feldman et al., 2012). Using available follow-up information, 110 children (the original 108 infants plus 2 infants recruited after the completion of the original study) were divided into three groups: diagnosed group (n = 13), lost diagnosis group (n = 5), and undiagnosed group (n = 92). The POEMS continued to show acceptable predictive validity. The POEMS total scores and mean number of elevated items were significantly higher in the diagnosed group than the undiagnosed group. The lost diagnosis group did not differ from the undiagnosed group on POEMS total scores and elevated items at any age, but the lost diagnosis group had significantly lower total scores and number of elevated items than the diagnosed group starting at 18 months. Both ASD core and subsidiary behaviours differentiated the diagnosed and undiagnosed groups from 9−36 months of age. Using 70 as a cut-off score, sensitivity, specificity, and positive predictive value (PPV) were .69, .84, and .38, respectively. The study provides further evidence that the POEMS may serve as a low-cost early screener for ASD in at risk children and pinpoint specific developmental and behavioural problems that may be amenable to very early intervention.
Resumo:
Objectif : Déterminer la fiabilité et la précision d’un prototype d’appareil non invasif de mesure de glucose dans le tissu interstitiel, le PGS (Photonic Glucose Sensor), en utilisant des clamps glycémiques multi-étagés. Méthodes : Le PGS a été évalué chez 13 sujets avec diabète de type 1. Deux PGS étaient testés par sujet, un sur chacun des triceps, pour évaluer la sensibilité, la spécificité, la reproductibilité et la précision comparativement à la technique de référence (le Beckman®). Chaque sujet était soumis à un clamp de glucose multi-étagé de 8 heures aux concentrations de 3, 5, 8 et 12 mmol/L, de 2 heures chacun. Résultats : La corrélation entre le PGS et le Beckman® était de 0,70. Pour la détection des hypoglycémies, la sensibilité était de 63,4%, la spécificité de 91,6%, la valeur prédictive positive (VPP) 71,8% et la valeur prédictive négative (VPN) 88,2%. Pour la détection de l’hyperglycémie, la sensibilité était de 64,7% et la spécificité de 92%, la VPP 70,8% et la VPN : 89,7%. La courbe ROC (Receiver Operating Characteristics) démontrait une précision de 0,86 pour l’hypoglycémie et de 0,87 pour l’hyperglycémie. La reproductibilité selon la « Clark Error Grid » était de 88% (A+B). Conclusion : La performance du PGS était comparable, sinon meilleure que les autres appareils sur le marché(Freestyle® Navigator, Medtronic Guardian® RT, Dexcom® STS-7) avec l’avantage qu’il n’y a pas d’aiguille. Il s’agit donc d’un appareil avec beaucoup de potentiel comme outil pour faciliter le monitoring au cours du traitement intensif du diabète. Mot clés : Diabète, diabète de type 1, PGS (Photonic Glucose Sensor), mesure continue de glucose, courbe ROC, « Clark Error Grid».
Resumo:
The work done in this master's thesis, presents a new system for the recognition of human actions from a video sequence. The system uses, as input, a video sequence taken by a static camera. A binary segmentation method of the the video sequence is first achieved, by a learning algorithm, in order to detect and extract the different people from the background. To recognize an action, the system then exploits a set of prototypes generated from an MDS-based dimensionality reduction technique, from two different points of view in the video sequence. This dimensionality reduction technique, according to two different viewpoints, allows us to model each human action of the training base with a set of prototypes (supposed to be similar for each class) represented in a low dimensional non-linear space. The prototypes, extracted according to the two viewpoints, are fed to a $K$-NN classifier which allows us to identify the human action that takes place in the video sequence. The experiments of our model conducted on the Weizmann dataset of human actions provide interesting results compared to the other state-of-the art (and often more complicated) methods. These experiments show first the sensitivity of our model for each viewpoint and its effectiveness to recognize the different actions, with a variable but satisfactory recognition rate and also the results obtained by the fusion of these two points of view, which allows us to achieve a high performance recognition rate.
Resumo:
Light emitting polymers (LEP) have drawn considerable attention because of their numerous potential applications in the field of optoelectronic devices. Till date, a large number of organic molecules and polymers have been designed and devices fabricated based on these materials. Optoelectronic devices like polymer light emitting diodes (PLED) have attracted wide-spread research attention owing to their superior properties like flexibility, lower operational power, colour tunability and possibility of obtaining large area coatings. PLEDs can be utilized for the fabrication of flat panel displays and as replacements for incandescent lamps. The internal efficiency of the LEDs mainly depends on the electroluminescent efficiency of the emissive polymer such as quantum efficiency, luminance-voltage profile of LED and the balanced injection of electrons and holes. Poly (p-phenylenevinylene) (PPV) and regio-regular polythiophenes are interesting electro-active polymers which exhibit good electrical conductivity, electroluminescent activity and high film-forming properties. A combination of Red, Green and Blue emitting polymers is necessary for the generation of white light which can replace the high energy consuming incandescent lamps. Most of these polymers show very low solubility, stability and poor mechanical properties. Many of these light emitting polymers are based on conjugated extended chains of alternating phenyl and vinyl units. The intra-chain or inter-chain interactions within these polymer chains can change the emitted colour. Therefore an effective way of synthesizing polymers with reduced π-stacking, high solubility, high thermal stability and high light-emitting efficiency is still a challenge for chemists. New copolymers have to be effectively designed so as to solve these issues. Hence, in the present work, the suitability of a few novel copolymers with very high thermal stability, excellent solubility, intense light emission (blue, cyan and green) and high glass transition temperatures have been investigated to be used as emissive layers for polymer light emitting diodes.
Resumo:
Light emitting polymers (LEPs) are considered as the second generation of conducting polymers. A Prototype LEP device based on electroluminescence emission of poly(p-phenylenevinylene) (PPV) was first assembled in 1990. LEPs have progressed tremendously over the past 20 years. The development of new LEP derivatives are important because polymer light emitting diodes (PLEDs) can be used for the manufacture of next-generation displays and other optoelectronic applications such as lasers, photovoltaic cells and sensors. Under this circumstance, it is important to understand thermal, structural, morphological, electrochemical and photophysical characteristics of luminescent polymers. In this thesis the author synthesizes a series of light emitting polymers that can emit three primary colors (RGB) with high efficiency
Resumo:
In this paper, we report the results of investigations on the potential of spray pyrolysis technique in depositing electron selective layer over larger area for the fabrication of inverted bulk-heterojunction polymer solar cells. The electron selective layer (In2S3) was deposited using spray pyrolysis technique and the linear heterojunction device thus fabricated exhibited good uniformity in photovoltaic properties throughout the area of the device. An MEH-PPV:PCBM inverted bulk-heterojunction device with In2S3 electron selective layer (active area of 3.25 3.25 cm2) was also fabricated and tested under indoor and outdoor conditions. Fromthe indoor measurements employing a tungsten halogen lamp (50mW/cm2 illumination), an opencircuit voltage of 0.41V and a short-circuit current of 5.6mA were obtained. On the other hand, the outdoor measurements under direct sunlight (74mW/cm2) yielded an open-circuit voltage of 0.46V and a short-circuit current of 9.37mA
Resumo:
This thesis is divided in to 9 chapters and deals with the modification of TiO2 for various applications include photocatalysis, thermal reaction, photovoltaics and non-linear optics. Chapter 1 involves a brief introduction of the topic of study. An introduction to the applications of modified titania systems in various fields are discussed concisely. Scope and objectives of the present work are also discussed in this chapter. Chapter 2 explains the strategy adopted for the synthesis of metal, nonmetal co-doped TiO2 systems. Hydrothermal technique was employed for the preparation of the co-doped TiO2 system, where Ti[OCH(CH3)2]4, urea and metal nitrates were used as the sources for TiO2, N and metals respectively. In all the co-doped systems, urea to Ti[OCH(CH3)2]4 was taken in a 1:1 molar ratio and varied the concentration of metals. Five different co-doped catalytic systems and for each catalysts, three versions were prepared by varying the concentration of metals. A brief explanation of physico-chemical techniques used for the characterization of the material was also presented in this chapter. This includes X-ray Diffraction (XRD), Raman Spectroscopy, FTIR analysis, Thermo Gravimetric Analysis, Energy Dispersive X-ray Analysis (EDX), Scanning Electron Microscopy(SEM), UV-Visible Diffuse Reflectance Spectroscopy (UV-Vis DRS), Transmission Electron Microscopy (TEM), BET Surface Area Measurements and X-ray Photoelectron Spectroscopy (XPS). Chapter 3 contains the results and discussion of characterization techniques used for analyzing the prepared systems. Characterization is an inevitable part of materials research. Determination of physico-chemical properties of the prepared materials using suitable characterization techniques is very crucial to find its exact field of application. It is clear from the XRD pattern that photocatalytically active anatase phase dominates in the calcined samples with peaks at 2θ values around 25.4°, 38°, 48.1°, 55.2° and 62.7° corresponding to (101), (004), (200), (211) and (204) crystal planes (JCPDS 21-1272) respectively. But in the case of Pr-N-Ti sample, a new peak was observed at 2θ = 30.8° corresponding to the (121) plane of the polymorph brookite. There are no visible peaks corresponding to dopants, which may be due to their low concentration or it is an indication of the better dispersion of impurities in the TiO2. Crystallite size of the sample was calculated from Scherrer equation byusing full width at half maximum (FWHM) of the (101) peak of the anatase phase. Crystallite size of all the co-doped TiO2 was found to be lower than that of bare TiO2 which indicates that the doping of metal ions having higher ionic radius into the lattice of TiO2 causes some lattice distortion which suppress the growth of TiO2 nanoparticles. The structural identity of the prepared system obtained from XRD pattern is further confirmed by Raman spectra measurements. Anatase has six Raman active modes. Band gap of the co-doped system was calculated using Kubelka-Munk equation and that was found to be lower than pure TiO2. Stability of the prepared systems was understood from thermo gravimetric analysis. FT-IR was performed to understand the functional groups as well as to study the surface changes occurred during modification. EDX was used to determine the impurities present in the system. The EDX spectra of all the co-doped samples show signals directly related to the dopants. Spectra of all the co-doped systems contain O and Ti as the main components with low concentrations of doped elements. Morphologies of the prepared systems were obtained from SEM and TEM analysis. Average particle size of the systems was drawn from histogram data. Electronic structures of the samples were identified perfectly from XPS measurements. Chapter 4 describes the photocatalytic degradation of herbicides Atrazine and Metolachlor using metal, non-metal co-doped titania systems. The percentage of degradation was analyzed by HPLC technique. Parameters such as effect of different catalysts, effect of time, effect of catalysts amount and reusability studies were discussed. Chapter 5 deals with the photo-oxidation of some anthracene derivatives by co-doped catalytic systems. These anthracene derivatives come underthe category of polycyclic aromatic hydrocarbons (PAH). Due to the presence of stable benzene rings, most of the PAH show strong inhibition towards biological degradation and the common methods employed for their removal. According to environmental protection agency, most of the PAH are highly toxic in nature. TiO2 photochemistry has been extensively investigated as a method for the catalytic conversion of such organic compounds, highlighting the potential of thereof in the green chemistry. There are actually two methods for the removal of pollutants from the ecosystem. Complete mineralization is the one way to remove pollutants. Conversion of toxic compounds to another compound having toxicity less than the initial starting compound is the second way. Here in this chapter, we are concentrating on the second aspect. The catalysts used were Gd(1wt%)-N-Ti, Pd(1wt%)-N-Ti and Ag(1wt%)-N-Ti. Here we were very successfully converted all the PAH to anthraquinone, a compound having diverse applications in industrial as well as medical fields. Substitution of 10th position of desired PAH by phenyl ring reduces the feasibility of photo reaction and produced 9-hydroxy 9-phenyl anthrone (9H9PA) as an intermediate species. The products were separated and purified by column chromatography using 70:30 hexane/DCM mixtures as the mobile phase and the resultant products were characterized thoroughly by 1H NMR, IR spectroscopy and GCMS analysis. Chapter 6 elucidates the heterogeneous Suzuki coupling reaction by Cu/Pd bimetallic supported on TiO2. Sol-Gel followed by impregnation method was adopted for the synthesis of Cu/Pd-TiO2. The prepared system was characterized by XRD, TG-DTG, SEM, EDX, BET Surface area and XPS. The product was separated and purified by column chromatography using hexane as the mobile phase. Maximum isolated yield of biphenyl of around72% was obtained in DMF using Cu(2wt%)-Pd(4wt%)-Ti as the catalyst. In this reaction, effective solvent, base and catalyst were found to be DMF, K2CO3 and Cu(2wt%)-Pd(4wt%)-Ti respectively. Chapter 7 gives an idea about the photovoltaic (PV) applications of TiO2 based thin films. Due to energy crisis, the whole world is looking for a new sustainable energy source. Harnessing solar energy is one of the most promising ways to tackle this issue. The present dominant photovoltaic (PV) technologies are based on inorganic materials. But the high material, low power conversion efficiency and manufacturing cost limits its popularization. A lot of research has been conducted towards the development of low-cost PV technologies, of which organic photovoltaic (OPV) devices are one of the promising. Here two TiO2 thin films having different thickness were prepared by spin coating technique. The prepared films were characterized by XRD, AFM and conductivity measurements. The thickness of the films was measured by Stylus Profiler. This chapter mainly concentrated on the fabrication of an inverted hetero junction solar cell using conducting polymer MEH-PPV as photo active layer. Here TiO2 was used as the electron transport layer. Thin films of MEH-PPV were also prepared using spin coating technique. Two fullerene derivatives such as PCBM and ICBA were introduced into the device in order to improve the power conversion efficiency. Effective charge transfer between the conducting polymer and ICBA were understood from fluorescence quenching studies. The fabricated Inverted hetero junction exhibited maximum power conversion efficiency of 0.22% with ICBA as the acceptor molecule. Chapter 8 narrates the third order order nonlinear optical properties of bare and noble metal modified TiO2 thin films. Thin films were fabricatedby spray pyrolysis technique. Sol-Gel derived Ti[OCH(CH3)2]4 in CH3CH2OH/CH3COOH was used as the precursor for TiO2. The precursors used for Au, Ag and Pd were the aqueous solutions of HAuCl4, AgNO3 and Pd(NO3)2 respectively. The prepared films were characterized by XRD, SEM and EDX. The nonlinear optical properties of the prepared materials were investigated by Z-Scan technique comprising of Nd-YAG laser (532 nm,7 ns and10 Hz). The non-linear coefficients were obtained by fitting the experimental Z-Scan plot with the theoretical plots. Nonlinear absorption is a phenomenon defined as a nonlinear change (increase or decrease) in absorption with increasing of intensity. This can be mainly divided into two types: saturable absorption (SA) and reverse saturable absorption (RSA). Depending on the pump intensity and on the absorption cross- section at the excitation wavelength, most molecules show non- linear absorption. With increasing intensity, if the excited states show saturation owing to their long lifetimes, the transmission will show SA characteristics. Here absorption decreases with increase of intensity. If, however, the excited state has strong absorption compared with that of the ground state, the transmission will show RSA characteristics. Here in our work most of the materials show SA behavior and some materials exhibited RSA behavior. Both these properties purely depend on the nature of the materials and alignment of energy states within them. Both these SA and RSA have got immense applications in electronic devices. The important results obtained from various studies are presented in chapter 9.
Resumo:
Los niños que presentan dolor abdominal agudo representan una de las principales demandas de atención en los servicios de Urgencias Pediátricas, convirtiéndose en un reto para quien realiza la valoración inicial la decisión de que paciente amerita realizar estudios adicionales, para descartar una patología quirúrgica. Considerando que la apendicitis es la primera emergencia quirúrgica en niños, y que sus complicaciones son un problema frecuente, es imprescindible que el clínico conozca cual es la utilidad y beneficio que le brindan las herramientas diagnósticas disponibles para realizar un diagnóstico más certero. Objetivo: Describir el manejo de los pacientes menores de 18 años con sospecha de apendicitis en la FCI y determinar la sensibilidad y especificidad de la ecografía en esta población. Métodos: Estudio de Prueba Diagnóstica. Revisión expedita de los niños valorados en la FCI con sospecha clínica de apendicitis aguda durante un periodo de 4 meses. Se tomaron datos de hallazgos ecográficos para apendicitis (positivos, negativos o indeterminados) y del desenlace de tener o no apendicitis. Posteriormente se realizó una inferencia mediante una tabla de contingencia, teniendo en cuenta intervalos de confianza para determinar la sensibilidad, especificidad, VPP, VPN y exactitud de la prueba basados en el diagnóstico final. Resultados: En 52% de pacientes que consultaron por dolor abdominal se sospecho patología quirúrgica, grupo en el que se utilizó la ecografía abdominal como herramienta diagnóstica para descartar apendicitis encontrando: sensibilidad: 63%(IC 95%, 48.6-75.5), especificidad: 82,7%(IC 95%, 76- 87.8) y exactitud: 78,2%(IC 95%, 72-83,4). La prevalencia de la enfermedad fue 22,8%, con probabilidad postprueba positiva de 88.3%(IC 95%, 82,1-92.6). Conclusiones: Los resultados de este estudio evidencian un menor rendimiento de la ecografía como prueba diagnóstica para apendicitis en pediatría en nuestro medio comparado al descrito en la literatura. Dicha discordancia probablemente se encuentra determinada por los sesgos propios de un estudio histórico como este, en el que básicamente la falta de uniformidad en el registro de datos en la historia clínica por los observadores (clínicos y radiólogos), así como las limitaciones para determinar el seguimiento de todos los pacientes que no fueron operados, pueden alterar la capacidad operativa real de la prueba. De ahí la importancia de realizar a futuro un estudio concurrente.
Resumo:
Antecedentes : la incidencia de sepsis neonatal tempana en prematuros es del 40% en nuestro medio, con mortalidad entre el 15-50% de los casos, el cual aumenta exponencialmente con la prematurez y se relaciona con secuelas neurológicas y pulmonares. Hasta la fecha no se han dado conclusiones definitivas en cuanto a la mejor prueba diagnóstica en este tópico, por lo anterior es de vital importancia encontrar el mejor método para su detección precoz. Objetivo: evaluar la utilidad de la histopatología placentaria en el diagnóstico de sepsis neonatal temprana de los recién nacidos menores de 36 semanas de edad gestacional, de la Fundación Santa Fe de Bogotá. Metodología: estudio de prueba diagnóstica donde se describieron los resultados obtenidos del análisis de la histopatología placentaria de los recién nacidos pretermino con sospecha de sepsis temprana comparados con el diagnostico de sepsis temprana probada. Resultados : se analizaron 114 pacientes con factores de riesgo para sepsis temprana de los cuales 74 tuvieron diagnóstico de sepsis probable confirmándose en cinco casos, encontrándose así para la histopatología placentaria sensibilidad del 100% IC 95% (90%-100%), especificidad 78.9% (IC 95% 70.7-87.0), índice de validez 79.8% (IC 95% 72%-87.6%), VPP 17.7 (IC 95%: 1.89%-33.8%) y VPN 100% (IC:98.7%-100%). Conclusión La corioamnionitis histológica es un biomarcador relevante en el diagnóstico oportuno de sepsis temprana probada en recién nacidos pretermino, ofreciendo una opción de ayuda diagnostica, no invasiva, con resultados definitivos en 24 horas.
Resumo:
La evaluación del trauma penetrante de cuello es un tema controversia. Algunas instituciones continúan manejando en forma agresiva el trauma de cuello, llevando a exploración quirúrgica a todo paciente. La selección de los métodos diagnostico más apropiado es un problema polémico. La tendencia actual en la literatura está dirigida hacia la racionalización del uso de los métodos de diagnóstico, indicándolos selectivamente de acuerdo con los hallazgos clínicos al ingreso. Objetivo: determinar el valor de signos blandos al ingreso de los pacientes con trauma penetrante de cuello para definir la necesidad de realizar estudios de diagnóstico adicionales. Métodos: es un estudio observacional de prueba diagnóstica en Hospital Occidente de Kennedy, durante los meses de agosto de 2009 hasta junio de 2010. Se incluyeron 207 pacientes con herida penetrante de cuello. A todos se les realizo una exploración física enfocándose en los signos blandos de lesión vascular, vía aérea y tracto gastrointestinal superior. Se analizaron la sensibilidad, especificidad, valor predictivo positivo y negativo de los signos blandos. Resultados: los signos blandos de lesión vascular tienen una sensibilidad de 95.65%, especificidad 47.83%, VPP de 18.64 %; VPN de 98.88%. Los signos blandos de lesión de vía aérea tienen una sensibilidad 94.12%, especificidad 91.05%, VVP 48.48%; VPN 99.43%. Conclusiones: los pacientes asintomáticos no requieren de otras pruebas diagnosticas para excluir lesiones que ameriten reparo quirúrgico, siendo el seguimiento clínico la conducta apropiada a seguir.
Resumo:
Introducción: Por medio del presente estudio se busca determinar el impacto de un curso teórico de mamografía en la categorización de microcalficaciones mamarias. Materiales y métodos: Se realizó un estudio doble ciego para evaluar la variación de los valores predictivos positivos (VPP) de los descriptores morfológicos y de distribución de calcificaciones del BI-RADS 4ed, luego de un curso teórico de mamografía de 6 horas distribuido en 12 charlas semanales de 30 minutos. Se utilizó la base de datos de un estudio previo, en el cual dos radiólogos clasificaron las calcificaciones presentes en 108 mamografías de pacientes con diagnóstico histológico. Se realizó una nueva categorización de las calcificaciones según los descriptores. Se calcularon además, los valores kappa ponderados de concordancia intra e inter-observador, la sensibilidad y especificidad. Resultados: Para las calcificaciones de alta probabilidad de malignidad (pleomórficas finas y lineales ramificadas en conjunto), se obtuvieron VPP de 41 y 40%, con aumento leve respecto a la lectura inicial. El índice kappa ponderado para el acuerdo inter-observador fue de 0,305 lo que indica concordancia débil, con discreto incremento respecto a la evaluación inicial 0,260. La concordancia intra-observador para el evaluador 1 dio un valor kappa 0,471, moderada; y para el evaluador 2 un valor kappa 0,400, débil. Discusión: Un módulo teórico corto permite mejorar ligeramente la concordancia inter-observador en la evaluación de microcalcificaciones mamarias mediante el BI-RADS 4ed, así como los valores predictivos positivos de microcalficaciones de alta probabilidad de malignidad.
Resumo:
La participación en plusvalías (PPV) es el instrumento de política de una reforma de gran transcendencia en Colombia: la recuperación de las rentas del suelo y su movilización social. Durante la fase de implementación de la PPV se han venido estableciendo esquemas operativos fragmentados que propician una visión procedimental y atomizada del tributo, la cual promueve lógicas institucionales que potencialmente retardan su evolución plena como instrumento de política de suelo. El análisis de la trayectoria de varias décadas de las ciudades colombianas con la contribución por valorización (CV) sugiere que la continuidad y evolución de este instrumento y sus instituciones se derivan en gran parte del manejo “ingenioso” de esta política frente a su entorno de implementación. Por tratarse de un instrumento de recuperación parcial de plusvalías, constituye un precedente para la PPV a partir del cual es posible derivar valiosas lecciones. Este artículo presenta para discusión los factores de viabilidad y sostenibilidad identificados a través del análisis de la experiencia de implementación y del proceso general de consolidación de la CV; así como reflexiones que de allí surgieron sobre la dirección que en el mismo contexto debería dársele a la implementación de la PPV, de manera que se propicien condiciones de entorno favorables a la evolución institucional y sostenibilidad de la reforma.-----Participation in Land Value Increments (participación en plusvalías-PPV) is an essential policy instrument of the urban Reform in Colombia designed to capture and socially mobilize land rents originated by public decisions and investments. The analysis of its recent implementation process in Bogota provides evidence that current institutional arrangements are creating a general tendency amongst the institutions involved towards isolated procedural management, which potentially hinders the integrated vision required to manage the instrument at the policy level. Special Assessment (contribución por valorización-CV), an earlier form of partial value capture, has a long history in Colombia as an effective financialinstrument for urban management. Analysis of the factors that have contributed to successfully consolidate CV show that its technical evolution, continuity and political legitimacy have been strongly supported by integrated institutions and strategic management. Through comparative analysis, the experience with CV is used to draw some useful parallels and insights for a discussion about how PPV´s implementation process should be redirected towards strategic policy thinking and “smart value capture”.
Resumo:
Introducción: En la práctica neuroquirurgica el uso de tornillos pediculares torácicos ha venido en aumento en el tratamiento de diferentes patologías de la espinales. Desde la descripción original, se confirma la adecuada canalización del trayecto mediante el uso del palpador, sin embargo la validez y seguridad de dicho instrumento es limitada y existe riesgo de complicaciones complejas. En este estudio se comprueba la seguridad y validez del uso del palpador para diagnosticar la integridad del trayecto pedicular torácico. Metodología: Se canalizaron pedículos torácicos en especímenes cadavéricos los cuales de manera aleatoria se clasificaron como normales (íntegros) o anormales (violados). Posteriormente cuatro cirujanos de columna, con diferentes grados de experticia, evaluaron el trayecto pedicular. Se realizaron estudios de concordancia obteniendo coeficiente Kappa, porcentaje total de precisión, sensibilidad, especificidad, VPP y VPN y el área bajo la curva ROC para determinar la precisión de la prueba. Resultados: La precisión y validez en el diagnostico del trayecto pedicular y localización del sitio de violación tienen relación directa con la experiencia y entrenamiento del cirujano, el evaluador con mayor experiencia obtuvo los mejores resultados. El uso del palpador tiene una buena precisión, área bajo la curva ROC 0.86, para el diagnostico de las lesiones pediculares. Discusión: La evaluación precisa del trayecto pedicular, presencia o ausencia de una violación, es dependiente del grado de experiencia del cirujano, adicionalmente la precisión diagnostica de la violación varía según la localización de esta.
Resumo:
Resumen basado en el de la publicación
Resumo:
Diferentes investigaciones internacionales han demostrado en los ??ltimos a??os que la educaci??n emocional y social mejora el rendimiento acad??mico y el bienestar del alumnado. Durante tres a??os la Universidad de Cantabria ha evaluado de forma externa la aplicaci??n intensiva de Educaci??n Responsable en tres de los cien centros participantes mediante una evaluaci??n pedag??gica y otra psicol??gica. Aqu?? se presenta el informe de la evaluaci??n psicol??gica. Se eval??an dos proyectos. PPV (Prevenir Para Vivir), dise??ado por la Fundaci??n de Ayuda contra la Drogadicci??n (FAD, 2004), est?? dirigido al desarrollo integral de los ni??os y j??venes con el objeto de prevenir problemas de conducta y comportamientos de riesgo para la salud. VyVE (Vida y Valores en la Educaci??n) es una ampliaci??n de PPV para profundizar en la comprensi??n y expresi??n emocional e incluir dos campos m??s: valores y creatividad.