993 resultados para Cochlear implantes
Resumo:
This paper is a guidebook for parents and educators to further understand the cochlear implant process from candidacy to surgery.
Resumo:
This study investigates whether deaf children with cochlear implants have oral reading fluency scores comparable to reading-age matched hearing peers. It also examines the reading comprehension skills of deaf children with cochlear implants.
Resumo:
Postural control was evaluated in cochlear implant participants with and without amplification under several auditory paradigms. Speed of sway was recorded in each condition by means of Computerized Dynamic Posturography. Results indicate that an external sound source significantly improves balance in patients with cochlear implants.
Resumo:
Spontaneous writing samples of deaf children with cochlear implants were analyzed for auxiliary verb errors. These results were compared to norms of typically developing children.
Resumo:
This study investigates whether mothers who have children with cochlear implants fine-tune their own vocabulary and sentence complexity to that of their child. Whether and how fine-tuning leads to faster growth in these language skills is explored.
Resumo:
The primary purpose of this study was to evaluate speech perception and localization abilities in children who have received sequential cochlear implants, with the first implant received before age 4 and the second implant received before age 12. Results indicate performance in the bilateral cochlear implant condition is significantly better than listening with each implant alone for the outcome measures used in this study.
Resumo:
The purpose of the present study was to evaluate the effects of bimodal (implant plus hearing aid) listening on speech recognition in four different environment conditions. Results indicate that there was little difference in the cochlear implant only and bimodal conditions.
Resumo:
O objetivo deste trabalho foi a produção e caracterização de componentes sinterizados de titânio para aplicação biomédica, obtidos através do processo de fabricação chamado de Moldagem de Pós por Injeção ( MPI ), ou “Metal Injection Molding” ( MIM ) na língua inglesa. Para a produção dos componentes de titânio, utilizou-se de pós de hidreto de titânio produzidos pelo processo de Hidretação-Dehidretação ( HDH ), no Laboratório de Transformação Mecânica - UFRGS. Foram realizados ensaios para a caracterização dos componentes sinterizados quanto às suas propriedades mecânicas, resistência à corrosão, características morfológicas e de biocompatibilidade. Este trabalho concentra-se no desenvolvimento e produção de componentes para área odontológica ( implantodontia ) e médica, visando a implementar a técnica de Moldagem de Pós por Injeção ( MPI ) de hidreto de titânio para aplicação na produção de implantes, tendo em vista que, atualmente, este processo não é utilizado para tal fim. Para as análises de biocompatibilidade foram produzidos parafusos corticais para utilização como implantes. Após a caracterização morfológica e química dos implantes produzidos foram realizados ensaios in vitro de corrosão e in vivo de biocompatibilidade onde foi possível observar algumas características da superfície do implante como, por exemplo, a susceptibilidade à corrosão por frestas e elevado recobrimento ósseo do implante.
Resumo:
In recent years there has been a significant growth in technologies that modify implant surfaces, reducing healing time and allowing their successful use in areas with low bone density. One of the most widely used techniques is plasma nitration, applied with excellent results in titanium and its alloys, with greater frequency in the manufacture of hip, ankle and shoulder implants. However, its use in dental implants is very limited due to high process temperatures (between 700 C o and 800 C o ), resulting in distortions in these geometrically complex and highly precise components. The aim of the present study is to assess osseointegration and mechanical strength of grade II nitrided titanium samples, through configuration of hollow cathode discharge. Moreover, new formulations are proposed to determine the optimum structural topology of the dental implant under study, in order to perfect its shape, make it efficient, competitive and with high definition. In the nitriding process, the samples were treated at a temperature of 450 C o and pressure of 150 Pa , during 1 hour of treatment. This condition was selected because it obtains the best wettability results in previous studies, where different pressure, temperature and time conditions were systematized. The samples were characterized by X-ray diffraction, scanning electron microscope, roughness, microhardness and wettability. Biomechanical fatigue tests were then conducted. Finally, a formulation using the three dimensional structural topology optimization method was proposed, in conjunction with an hadaptive refinement process. The results showed that plasma nitriding, using the hollow cathode discharge technique, caused changes in the surface texture of test specimens, increases surface roughness, wettability and microhardness when compared to the untreated sample. In the biomechanical fatigue test, the treated implant showed no flaws, after five million cycles, at a maximum fatigue load of 84.46 N. The results of the topological optimization process showed well-defined optimized layouts of the dental implant, with a clear distribution of material and a defined edge
Resumo:
This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study
Resumo:
The evaluation criteria of the cases treated with dental implants are based on clinical and radiographic tests. In this context it is important to conduct research to determine prognosis of different types of prosthetic rehabilitation and determination of the main problems affecting this type of treatment. Thus, the objective of this study was to assess the prosthetic conditions of individuals rehabilitated with implant-supported prosthesis. In this cross-sectional study 153 patients were treated, accounting for a sample of 509 implants. The failures were observed by clinical and radiographic examination. The results showed that the fracture (0.2%) loss (0.4%) and loosening of the screws (3.3%) were failures are less frequent. The fracture structures as the resin (12.4%), porcelain (5.5%) and metallic (1.5%), loss of resin that covers the screw (23.8%) and loss of retention overdentures on implants (18.6%) had a higher occurrence. The failure of adaptation between the abutment and the implant (6.9%) and especially between the prosthesis and the abutment (25.4%) had a high prevalence and, when related to other parameters showed a significant association, particularly with the cemented prosthesis (OR = 6.79). It can be concluded that to minimize the appearance of failures, protocols must be observed from diagnosis to the settlement and control of prostheses on implants, particularly with respect to technical steps of the making of the prosthesis and care in radiographic evaluating the fit between their components
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Este estudo apresenta resultados preliminares obtidos com um novo filtro permanente de veia cava, baseado no desenho de Greenfield, com três hastes prolongadas de um total de seis, para dar estabilidade central ao filtro na luz da veia cava. Neste artigo, relatamos sua avaliação clínica preliminar quanto à aplicabilidade, eficácia e segurança. de agosto de 2004 a dezembro de 2006, 15 filtros foram implantados em nove homens e seis mulheres, com idades variando de 38 a 79 anos (média de 57,8 anos). O acesso foi feito sempre por via transjugular. As indicações foram: trombose venosa proximal, com contra-indicação de anticoagulação em 12 pacientes; complicações hemorrágicas com anticoagulação em dois pacientes; e embolia pulmonar, apesar de anticoagulação adequada, em um paciente. Os filtros foram avaliados quanto à liberação, inclinação, mau posicionamento e perfuração de cava. No seguimento, avaliou-se trombose no local de acesso, tromboembolismo venoso recorrente, migração do filtro e trombose de cava pelo ultra-som. Nenhum paciente recebeu anticoagulantes no seguimento. O filtro foi liberado com sucesso em todos os casos sem mau posicionamento, inclinação, perfuração ou trombose de acesso. Os pacientes foram seguidos entre 3 e 23 meses (média de 11 meses). Nenhum paciente teve recorrência de tromboembolismo venoso. Não houve casos de trombose de veia cava ou migração do filtro. Óbito ocorreu em sete casos, todos relacionados com a moléstia de base. Os resultados preliminares indicam potencial eficácia e segurança do uso do novo filtro no período estudado.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Comparar implantes de polietileno poroso no estado sólido e gel em cavidades enucleadas. MÉTODOS: Trinta e seis coelhos albinos foram submetidos à enucleação do olho direito, recebendo esferas de polietileno poroso (18 animais) ou gel (18 animais), de 12 mm de diâmetro. Os animais foram avaliados semanalmente por exame clínico e mensalmente por ultra-sonografia modo B, realizada 30, 60 e 90 dias após a cirurgia, tendo sido os animais sacrificados aos 90 dias. Após o sacrifício, o conteúdo orbitário foi removido e examinado histologicamente. RESULTADOS: Cinco animais (27,2%) que receberam os implantes de polietileno poroso tiveram extrusão do implante. Houve extrusão em 94,4% dos animais que receberam a esfera de polietileno gel, tendo-se observado que o diâmetro das esferas gel extruídas encontrava-se aumentado em relação ao diâmetro da esfera implantada. A ultra-sonografia mostrou que o implante de polietileno poroso se vascularizou e que o gel não, o que foi confirmado pelo exame histológico. CONCLUSÃO: Esferas de polietileno no estado gel sofrem hidratação e aumentam de volume, sendo necessário conhecer o seu tamanho final antes da implantação. A ultra-sonografia permite conhecer a vascularização do implante, podendo ser usada na avaliação da integração esfera-hospedeiro.