857 resultados para plasma nanoscience
Resumo:
This paper presents cost-effectiveness analyses (CEAs) of plasma collection via two alternative methods: whole blood collection (WBC) and erythroplasmapheresis collection (EPC). The objective of the study is to provide an answer to the question 'What is the least-cost method of plasma production'. This question is answered, both from the viewpoint of the blood collection agency (using financial CEA) and from that of 'society' as a whole (using economic CEA). We employ detailed financial data and economic survey data for collections made by a blood collection agency and to WBC and EPC donors in Brisbane, Australia. The results indicate that, despite the superior yield provided by EPC, WBC is actually more cost-effective. This result is robust to thorough sensitivity analysis and arises regardless of whether an economic or financial perspective is taken. We conclude that, ceteris paribus, the cost of recruiting new plasma donors would need to be quite substantial for marginal investments in EPC to be considered cost-effective. Crown Copyright (C) 2002 Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Spray-dried blood plasma (DBP) (10.9 g/100 g [w/w] nitrogen) was added to medium-protein biscuit flour (1.4 g/100 g N) during pasta manufacture. High-protein durum semolina (2.0 g/100 g N) Was used to produce the control pasta. Sensory data indicated that the addition of DBP produced pasta with significantly better colour intensity and acceptability. aroma intensity, flaN our intensity. textural strength, texture acceptability, aftertaste intensity, aftertaste acceptability. and overall acceptability The DBP/biscuit flour formulation that gave the optimum balance between pasta protein content and organoleptic acceptability contained 2.2 g/100 g DBP. A higher content of DBP resulted in increased protein levels, but these pasta formulations, ere less acceptable organoleptically. (C) 2002 Swiss Society of Food Science and Technology. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Crustacean color change results from the differential translocation of chromatophore pigments, regulated by neurosecretory peptides like red pigment concentrating hormone (RPCH) that, in the red ovarian chromatophores of the freshwater shrimp Macrobrachium olfersi, triggers pigment aggregation via increased cytosolic cGMP and Ca(2+) of both smooth endoplasmatic reticulum (SER) and extracellular origin. However, Ca(2+) movements during RPCH signaling and the mechanisms that regulate intracellular [Ca(2+)] are enigmatic. We investigate Ca(2+) transporters in the chromatophore plasma membrane and Ca(2+) movements that occur during RPCH signal transduction. Inhibition of the plasma membrane Ca(2+)-ATPase by La(3+) and indirect inhibition of the Na(+)/Ca(2+) exchanger by ouabain induce pigment aggregation, revealing a role for both in Ca(2+) extrusion. Ca(2+) channel blockade by La(3+) or Cd(2+) strongly inhibits slow-phase RPCH-triggered aggregation during which pigments disperse spontaneously. L-type Ca(2+) channel blockade by gabapentin markedly reduces rapid-phase translocation velocity; N- or P/Q-type blockade by omega-conotoxin MVIIC strongly inhibits RPCH-triggered aggregation and reduces velocity, effects revealing RPCH-signaled influx of extracellular Ca(2+). Plasma membrane depolarization, induced by increasing external K(+) from 5 to 50 mM, produces Ca(2+)-dependent pigment aggregation, whereas removal of K(+) from the perfusate causes pigment hyperdispersion, disclosing a clear correlation between membrane depolarization and pigment aggregation; K(+) channel blockade by Ba(2+) also partially inhibits RPCH action. We suggest that, during RPCH signal transduction, Ca(2+) released from the SER, together with K(+) channel closure, causes chromatophore membrane depolarization, leading to the opening of predominantly N- and/or P/Q-type voltage-gated Ca(2+) channels, and a Ca(2+)/cGMP cascade, resulting in pigment aggregation. J. Exp. Zool. 313A:605-617, 2010. (C) 2010 Wiley-Liss, Inc.
Resumo:
Poly(pyrrole) (PPY) coating was prepared on a stainless-steel (SS) wire for solid-phase microextraction (SPME) by electrochemical deposition (cyclic voltammetric). The PPY was evaluated by analyzing new-generation antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline) in plasma sample by SPME and liquid chromatography with UV detection (LC-UV). The effect of electrolyte Solution (lithium perchlorate or tetrabutylammonium perchlorate) and the number of cycles (50, 100 or 200) applied during the polymerization process on the SPME performance was evaluated. Important factors in the optimization of SPME efficiency such as extraction time, temperature, pH, influence of plasma proteins on sorption mechanisms, and desorption conditions are discussed. The SPME-PPY/LC method showed to be linear in concentrations ranging from the limit of quantification (LOQ) to 1200 ng mL(-1). The LOQ values range from 16 to 25 ng mL-1. The inter-day precision of the SPME-PPY/LC method presented coefficient of variation (CV) lower than 15%. Based on analytical validation results, the SPME-PPY/LC methodology showed to be adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the SPME-PPY/LC method was applied to the analysis of plasma samples from elderly depressed patients. (c) 2009 Elsevier B.V. All rights reserved,
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for simultaneous determination of mirrazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline in human plasma was developed, validated and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. The quantification limits of the in-tube SPME/LC method varied between 20 and 50 ng/mL, with a coefficient of variation lower than 10%. The response of the in-tube SPME/LC method for most of the drugs was linear over a dynamic range from 50 to 500 ng/mL, with correlation coefficients higher than 0.9985. The in-tube SPME/LC can be successfully used to analyze plasma samples from ageing patients undergoing therapy with nontricyclic antidepressants. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and reproducible method by microextraction packed sorbent and liquid chromatography with UV detection (MEPS/LC-UV) is described for the determination of new generation antidepressants (sertraline, mirtazapine, fluoxetine, citalopram and paroxetine) in human plasma samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) influenced the MEPS/LC efficiency significantly. Important factors in the optimization of MEPS efficiency, as well as washing steps and carryover effect are discussed. The analyses were carried out using small sample volumes (400 mu L.), and in a short time period (3 min for the entire sample preparation step). The MEPS/LC-UV method was shown to be linear at concentrations ranging from the limit of quantification (LOQ) to 1000 ng mL(-1). The LOQ values ranged from 10 to 25 ng mL(-1). The inter-day precision of the method presented coefficient of the variation ranging from 1.3% to 8.7%. On the basis of analytical validation, it is shown that the MEPS/LC-UV methodology is adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the MEPS/LC-UV method was applied to analysis of plasma samples from elderly depressed patients. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Analytical and bioanalytical methods of high-performance liquid chromatography with fluorescence detection (HPLC-FLD) were developed and validated for the determination of chloroaluminum phthalocyanine in different formulations of polymeric nanocapsules, plasma and livers of mice. Plasma and homogenized liver samples were extracted with ethyl acetate, and zinc phthalocyanine was used as internal standard. The results indicated that the methods were linear and selective for all matrices studied. Analysis of accuracy and precision showed adequate values, with variations lower than 10% in biological samples and lower than 2% in analytical samples. The recoveries were as high as 96% and 99% in the plasma and livers, respectively. The quantification limit of the analytical method was 1.12 ng/ml, and the limits of quantification of the bioanalytical method were 15 ng/ml and 75 ng/g for plasma and liver samples, respectively. The bioanalytical method developed was sensitive in the ranges of 15-100 ng/ml in plasma and 75-500 ng/g in liver samples and was applied to studies of biodistribution and pharmacokinetics of AlClPc. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A sensitive, selective, and reproducible in-tube polypyrrole-coated capillary (PPY) solid-phase microextraction and liquid chromatographic method for fluoxetine and norfluoxetine enantiomers analysis in plasma samples has been developed, validated, and further applied to the analysis of plasma samples from elderly patients undergoing therapy with antidepressants. Important factors in the optimization of in-tube SPME efficiency are discussed, including the sample draw/eject volume, draw/eject cycle number, draw/eject flow-rate, sample pH, and influence of plasma proteins. Separation of the analytes was achieved with a Chiralcel OD-R column and a mobile phase consisting of potassium hexafluorophosphate 7.5 mM and sodium phosphate 0.25 M solution, pH 3.0, and acetonitrile (75:25, v/v) in the isocratic mode, at a flow rate of 1.0 mL/min. Detection was carried out by fluorescence absorbance at Ex/Em 230/290 nm. The multifunctional porous surface structure of the PPY-coated film provided high precision and accuracy for enantiomers. Compared with other commercial capillaries, PPY-coated capillary showed better extraction efficiency for all the analytes. The quantification limits of the proposed method were 10 ng/mL for R- and S-fluoxetine, and 15 ng/mL for R- and S-norfluoxetine, with a coefficient of variation lower than 13%. The response of the method for enantiomers is linear over a dynamic range, from the limit of quantification to 700ng/mL, with correlation coefficients higher than 0.9940. The in-tube SPME/LC method can therefore be successfully used to analyze plasma samples from ageing patients undergoing therapy with fluoxetine. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and automated method is described for determination of rifampicin in plasma samples for therapeutic drug monitoring by in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC). Important factors in the optimization of in-tube SPME are discussed, such as coating type, sample pH, sample draw/eject volume, number of draw/eject cycles, and draw/eject flow rate. Analyte pre-concentrated in the polyethylene glycol phase was directly transferred to the liquid chromatographic column by percolation of the mobile phase, without carryover. The method was linear over the 0.1-100 mu g/mL range, with a linear coefficient value (r(2)) of 0.998. The inter-assay precision presented coefficient of variation <= 1.7%. The effectiveness and practicability of the proposed method are proven by analysis of plasma samples from ageing patients undergoing therapy with rifampicin. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Study objective: To investigate the effect of the voluntary folate fortification policy in Australia on serum folate and total plasma homocysteine (tHcy) concentrations. Design: Population based cohort study. Setting: Perth, Western Australia. Participants: Men and women aged 27 to 77 years (n = 468), who were originally randomly selected from the Perth electoral roll. The cohort was surveyed in 1995/96 before widespread introduction of folate fortification of a variety of foods, and followed up on two occasions, firstly in 1998/99 and again in 2001, when a moderate number of folate fortified foods were available. Subjects with abnormal serum creatinine concentrations at baseline were excluded from this analysis. Main results: Repeated measures analysis of variance was used to determine changes in serum folate and tHcy over the three surveys and to assess whether time trends were related to age, sex, MTHFR C677T genotype, or consumption of folate fortified foods. An increase (38%) in mean serum folate (p < 0.0005) and a decrease (21%) in mean tHcy (p < 0.0005) were seen after introduction of the voluntary folate fortification policy in Australia. Serum folate was consistently higher (p = 0.032) and tHcy was consistently lower (p = 0.001) in subjects who consumed at least one folate fortified food compared with subjects who did not consume any folate fortified foods in the previous week. The time related changes in serum folate and tHcy were affected only by intake of folate fortified foods (p < 0.0005) and not by any other measured variables including age, sex, or MTHFR genotype. Conclusion: Voluntary fortification of foods with folate in Australia has been followed by a substantial increase in serum folate and decrease in tHcy in the general population.
Resumo:
This paper reports an investigation on techniques for determining elastic modulus and intrinsic stress gradient in plasma-enhanced chemical vapor deposition (PECVD) silicon nitride thin films. The elastic property of the silicon nitride thin films was determined using the nanoindentation method on silicon nitride/silicon bilayer systems. A simple empirical formula was developed to deconvolute the film elastic modulus. The intrinsic stress gradient in the films was determined by using micrometric cantilever beams, cross-membrane structures and mechanical simulation. The deflections of the silicon nitride thin film cantilever beams and cross-membranes caused by in-thickness stress gradients were measured using optical interference microscopy. Finite-element beam models were built to compute the deflection induced by the stress gradient. Matching the deflection computed under a given gradient with that measured experimentally on fabricated samples allows the stress gradient of the PECVD silicon nitride thin films introduced from the fabrication process to be evaluated.