995 resultados para Mandible deviation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was the single-laboratory validation of a quantitative method for the determination of amoxicillin residues in support of cleaning control and validation. Linearity was demonstrated between 2.5 and 17.5 μg/mL, without matrix effects. Mean recoveries ranged from 84.00 to 103.74% and the relative standard deviation under repetitivity and within-reproducibility conditions were from 0.58 to 4.20% and from 0.79 to 4.39%, respectively. The theoretical limits of detection and quantification were 0.133 and 0.442 μg/mL, respectively. The studied method was suitable for cleaning control purpose within good manufacturing practices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We optimized a method for the determination of three main folate isoforms in leafy vegetables. Analysis was carried out by HPLC, using gradient of elution and fluorescence detection. Limits of quantification were 2 ng/mL; 2 ng/mL and 28 ng/mL for tetrahydrofolate (THF), 5-methyltetrahydrofolate (5-MTHF) and 5-formyltetrahydrofolate (5-FTHF), respectively. Recovery rates of THF, 5-MTHF and 5-FTHF varied from 87.86 to 100.64%; 88.12-94.22% and 89.82-106.69%, respectively. Test of repeatability showed relative standard deviation for peak areas lower than 10%. Tests for linearity showed high coefficients of determination. The results showed advances in folates extraction and analysis in raw and cooked leafy vegetables.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensitive preconcentration procedure for spectrophotometeric determination of aluminum was developed. Aluminum as aluminon complex is adsorbed on microcrystalline naphthalene. The naphthalene containing the complex is dissolved in 3 mL of acetone and its absorbance is measured at 544 nm. The effect of various factors on the preconcentration of aluminum was investigated. The calibration graph was linear in the range of 1-60 mg L-1. The limit of detection was 0.52 mg L-1 and relative standard deviation for the determination of 5 mg L-1 was 2.65%. The proposed solid phase extraction procedure was applied to determination of aluminum in food samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An evaluation of the pesticides extraction from onion using a modern sample preparation method (QuEChERS) and determination by liquid chromatography tandem mass spectrometry was carried out. All the calibration curves showed r>0.99. The recoveries ranged between 61.8 and 120.0% with relative standard deviation lower than 20% for all compounds. Due to the occurrence of matrix effect, the quantification was performed using matrix-matched calibration. The limits of quantification of the method were between 0.0005 and 0.05 mg kg-1. The method shows the advantages of not require the clean-up step and consume low volume of organic solvents, decreasing time, costs and residues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Identification of order of an Autoregressive Moving Average Model (ARMA) by the usual graphical method is subjective. Hence, there is a need of developing a technique to identify the order without employing the graphical investigation of series autocorrelations. To avoid subjectivity, this thesis focuses on determining the order of the Autoregressive Moving Average Model using Reversible Jump Markov Chain Monte Carlo (RJMCMC). The RJMCMC selects the model from a set of the models suggested by better fitting, standard deviation errors and the frequency of accepted data. Together with deep analysis of the classical Box-Jenkins modeling methodology the integration with MCMC algorithms has been focused through parameter estimation and model fitting of ARMA models. This helps to verify how well the MCMC algorithms can treat the ARMA models, by comparing the results with graphical method. It has been seen that the MCMC produced better results than the classical time series approach.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Composite methods using ONIOM and different basis sets have been used to calculate proton and electron affinities for a set of alcohols at QCISD(T)/6-311++G(2df,p) level of theory. The study was carried out considering HF, MP2 and DFT (25 exchange correlation functional) methods. The calculation performed at ONIOM2(QCISD(T)/6-311++G(2df,p):HF/6-31G(d))//ONIOM2(O3LYP/6-31G(d):HF/6-31G(d)) resulted in the smallest average absolute deviation for AP and AE, 4,75 kJ/mol e 0,43 eV, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new simple and sensitive flotation-spectrophotometric method for the determination of cetylpyridinium chloride (CPC) is reported. The method is based on the formation of an ion- associate between CPC and Orange II (OR) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. The aqueous solution was discarded and the adsorbed ion associate on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 480 nm. The apparent molar absorptivity (Ε) of the ion associate was determined to be 4.12 x 10(5) L mol-1 cm-1. The calibration graph was linear in the concentration range of 15-800 ng mL-1 of CPC with a correlation coefficient of 0.9988. The limit of detection (LOD) was 10.8 ng mL-1. The relative standard deviation (RSD) for determination of 100 and 800 ng mL-1 of CPC was 3.47 and 2.04% (n=7), respectively. The method was successfully applied to the determination of CPC in a commercial mouth washer product.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ten common doubts of chemistry students and professionals about their statistical applications are discussed. The use of the N-1 denominator instead of N is described for the standard deviation. The statistical meaning of the denominators of the root mean square error of calibration (RMSEC) and root mean square error of validation (RMSEV) are given for researchers using multivariate calibration methods. The reason why scientists and engineers use the average instead of the median is explained. Several problematic aspects about regression and correlation are treated. The popular use of triplicate experiments in teaching and research laboratories is seen to have its origin in statistical confidence intervals. Nonparametric statistics and bootstrapping methods round out the discussion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A turbidimetric method has been used for quantification of fractionated heparin (FH) in pharmaceutical dosage. The UV detection at two wavelengths (290 and 500 nm) showed a significant increase in sensitivity of the method, specificity, and linearity to range 5.0-50.0 µg mL-1 and 50.0-200.0 µg mL-1, respectively (r < 0.99). At both wavelengths, the method was precise (inter-assay CV < 5.0%, and intra-assay CV < 3.0%), accurate (maximum deviation of ± 12%), and robust to the parameters evaluated. Turbidimetry proved to be easy, inexpensive and relatively fast. The results obtained attest to the reliability of the method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work reports the optimization and method validation for sulfonamides (sulfamethazine, sulfaquinoxaline, sulfadimethoxine and sulfathiazole) in shrimp muscle using HPLC-UV. The sulfonamides were extracted with acetonitrile and acetic acid, and the extract cleaned up with a Strata SCX SPE cartridge prior to analysis. The method presented linearity in the range of 20-120 µg kg-1, good linear correlation (r > 0.99), and limits of quantification in the range of 4.7-20.2 µg kg-1. The recovery for shrimp muscles spiked with 50-150 µg kg-1 ranged from 63.2-108.0%. Precision and accuracy analysis showed acceptable relative standard deviation. Commercial shrimps were analyzed and sulfonamides don't were found above of the method limit of quantification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was found that cinnamic acid can react with potassium permanganate in the acidic medium and produce chemiluminescence, which was greatly enhanced by glyoxal. Under the optimum conditions, the linear range for the determination of cinnamic acid was 1.0×10-8 to 1.0×10-4 mol L-1 with a detection limit of 8.0×10-9 mol L-1, the relative standard deviation was 1.7% for 2.0×10-6 mol L-1 cinnamic acid solution in nine repeated measurements. This method was found to be novel0simple0fast and sensitive, it was successfully applied to the determination of cinnamic acid in human urine. Furthermore, the possible reaction mechanism was also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Adapalene is a retinoid drug often used for disorders of the skin, mainly acne. In this work, an analytical method for the quantification of adapaleno in suspensions of nanocapsules by HPLC was developed and validated. The method was linear in the range of 10-30 µg mL-1, with a good correlation coefficient (r = 0.994). Precision and accuracy analysis showed low relative standard deviation (< 4.6%) and a good recovery percentual (98.2-106.9%). The procedure was specific, linear, precise, exact and robust so that the method can be applied in quantification of adapalene in suspensions of nanocapsules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Extended Hildebrand Solubility Approach (EHSA) was successfully applied to evaluate the solubility of Indomethacin in 1,4-dioxane + water mixtures at 298.15 K. An acceptable correlation-performance of EHSA was found by using a regular polynomial model in order four of the W interaction parameter vs. solubility parameter of the mixtures (overall deviation was 8.9%). Although the mean deviation obtained was similar to that obtained directly by means of an empiric regression of the experimental solubility vs. mixtures solubility parameters, the advantages of EHSA are evident because it requires physicochemical properties easily available for drugs.