997 resultados para Light-fields


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the cytotoxicity of an experimental restorative composite resin subjected to different light-curing regimens. METHODS: Forty round-shaped specimens were prepared and randomly assigned to four experimental groups (n=10), as follows: in Group 1, no light-curing; in Groups 2, 3 and 4, the composite resin specimens were light-cured for 20, 40 or 60 s, respectively. In Group 5, filter paper discs soaked in 5 µL PBS were used as negative controls. The resin specimens and paper discs were placed in wells of 24-well plates in which the odontoblast-like cells MDPC-23 (30,000 cells/cm²) were plated and incubated in a humidified incubator with 5% CO2 and 95% air at 37ºC for 72 h. The cytotoxicity was evaluated by the cell metabolism (MTT assay) and cell morphology (SEM). The data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (p<0.05). RESULTS: In G1, cell metabolism decreased by 86.2%, indicating a severe cytotoxicity of the non-light-cured composite resin. On the other hand, cell metabolism decreased by only 13.3% and 13.5% in G2 and G3, respectively. No cytotoxic effects were observed in G4 and G5. In G1, only a few round-shaped cells with short processes on their cytoplasmic membrane were observed. In the other experimental groups as well as in control group, a number of spindle-shaped cells with long cytoplasmic processes were found. CONCLUSION: Regardless of the photoactivation time used in the present investigation, the experimental composite resin presented mild to no toxic effects to the odontoblast-like MDPC-23 cells. However, intense cytotoxic effects occurred when no light-curing was performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare the polymerization shrinkage stress of composite resins (microfilled, microhybrid and hybrid) photoactivated by quartz-tungsten halogen light (QTH) and light-emitting diode (LED). Glass rods (5.0 mm x 5.0 cm) were fabricated and had one of the surfaces air-abraded with aluminum oxide and coated with a layer of an adhesive system, which was photoactivated with the QTH unit. The glass rods were vertically assembled, in pairs, to a universal testing machine and the composites were applied to the lower rod. The upper rod was placed closer, at 2 mm, and an extensometer was attached to the rods. The 20 composites were polymerized by either QTH (n=10) or LED (n=10) curing units. Polymerization was carried out using 2 devices positioned in opposite sides, which were simultaneously activated for 40 s. Shrinkage stress was analyzed twice: shortly after polymerization (t40s) and 10 min later (t10min). Data were analyzed statistically by 2-way ANOVA and Tukey's test (a=5%). The shrinkage stress for all composites was higher at t10min than at t40s, regardless of the activation source. Microfilled composite resins showed lower shrinkage stress values compared to the other composite resins. For the hybrid and microhybrid composite resins, the light source had no influence on the shrinkage stress, except for microfilled composite at t10min. It may be concluded that the composition of composite resins is the factor with the strongest influence on shrinkage stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated in vitro the pulp chamber temperature rise induced by the light-activated dental bleaching technique using different light sources. The root portions of 78 extracted sound human mandibular incisors were sectioned approximately 2 mm below the cementoenamel junction. The root cavities of the crowns were enlarged to facilitate the correct placing of the sensor into the pulp chamber. Half of specimens (n=39) was assigned to receive a 35% hydrogen peroxide gel on the buccal surface and the other halt (n=39) not to receive the bleaching agent. Three groups (n=13) were formed for each condition (bleach or no bleach) according to the use of 3 light sources recommended for dental bleaching: a light-emitting diode (LED)laser system, a LED unit and a conventional halogen light. The light sources were positioned perpendicular to the buccal surface at a distance of 5 mm and activated during 30 s. The differences between the initial and the highest temperature readings for each specimen were obtained, and, from the temperature changes, the means for each specimen and each group were calculated. The values of temperature rise were compared using Kruskal-Wallis test at 1% significance level. Temperature rise varied significantly depending on the light-curing unit, with statistically significant differences (p<0.01) among the groups. When the bleaching agent was not applied, the halogen light induced the highest temperature rise (2.38±0.66ºC). The LED unit produced the lowest temperature increase (0.29±0.13ºC); but there was no significant difference between LED unit and LED-laser system (0.35±0.15ºC) (p>0.01). When the bleaching agent was applied, there were significant differences among groups (p<0.01): halogen light induced the highest temperature rise (1.41±0.64ºC), and LED-laser system the lowest (0.33±0.12ºC); however, there was no difference between LED-laser system and LED unit (0.44±0.11ºC). LED and LED-laser system did not differ significantly from each other regardless the temperature rise occurred with or without bleaching agent application. It may be concluded that during light-activated tooth bleaching, with or without the bleaching agent, halogen light promoted higher pulp chamber temperature rise than LED unit and LED-laser system. The tested light-curing units provided increases in the pulp chamber temperature that were compatible with pulpal health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (α=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (±4.29); II-8.57 (±3.19); III-7.97 (±2.16); IV-12.56 (±3.11); V-11.45 (±3.77); and VI-7.47 (±1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the influence of different photopolymerization (halogen, halogen soft-start and LED) systems on shear bond strength (SBS) and marginal microleakage of composite resin restorations. Forty Class V cavities (enamel and dentin margins) were prepared for microleakage assessment, and 160 enamel and dentin fragments were prepared for the SBS test, and divided into 4 groups. Kruskal-Wallis and Wilcoxon tests showed statistically significant difference in microleakage between the margins (p < 0.01) with incisal margins presenting the lowest values. Among the groups, it was observed that, only at the cervical margin, halogen soft-start photo polymerization presented statistically significant higher microleakage values. For SBS test, ANOVA showed no statistical difference (p > 0.05) neither between substrates nor among groups. It was concluded that Soft-Start technique with high intensity end-light influenced negatively the cervical marginal sealing, but the light-curing systems did not influence adhesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This study evaluated the influence of light sources and immersion media on the color stability of a nanofilled composite resin. MATERIAL AND METHODS: Conventional halogen, high-power-density halogen and high-power-density light-emitting diode (LED) units were used. There were 4 immersion media: coffee, tea, Coke® and artificial saliva. A total of 180 specimens (10 mm x 2 mm) were prepared, immersed in artificial saliva for 24 h at 37±1ºC, and had their initial color measured with a spectrophotometer according to the CIELab system. Then, the specimens were immersed in the 4 media during 60 days. Data from the color change and luminosity were collected and subjected to statistical analysis by the Kruskall-Wallis test (p<0.05). For immersion time, the data were subjected to two-way ANOVA test and Fisher's test (p<0.05). RESULTS: High-power-density LED (ΔE=1.91) promoted similar color stability of the composite resin to that of the tested halogen curing units (Jet Lite 4000 plus - ΔE=2.05; XL 3000 - ΔE=2.28). Coffee (ΔE=8.40; ΔL=-5.21) showed the highest influence on color stability of the studied composite resin. CONCLUSION: There was no significant difference in color stability regardless of the light sources, and coffee was the immersion medium that promoted the highest color changes on the tested composite resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Onion (Allium cepa) is one of the most cultivated and consumed vegetables in Brazil and its importance is due to the large laborforce involved. One of the main pests that affect this crop is the Onion Thrips (Thrips tabaci), but the spatial distribution of this insect, although important, has not been considered in crop management recommendations, experimental planning or sampling procedures. Our purpose here is to consider statistical tools to detect and model spatial patterns of the occurrence of the onion thrips. In order to characterize the spatial distribution pattern of the Onion Thrips a survey was carried out to record the number of insects in each development phase on onion plant leaves, on different dates and sample locations, in four rural properties with neighboring farms under different infestation levels and planting methods. The Mantel randomization test proved to be a useful tool to test for spatial correlation which, when detected, was described by a mixed spatial Poisson model with a geostatistical random component and parameters allowing for a characterization of the spatial pattern, as well as the production of prediction maps of susceptibility to levels of infestation throughout the area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the present study was to evaluate the effects of light and temperature on germination of Cereus pernambucensis seeds, a species of columnar cactus native to Brazil and naturally incident in the restinga. Cereus pernambucensis seeds were incubated under different temperatures, from 5 to 45 °C, with 5 °C intervals, and under alternating temperatures of 15-20 °C, 15-30 °C, 20-25 °C, 20-30 °C, 20-35 °C, 25-30 °C, 25-35 °C, and 30-35 °C, both under continuous white light and dark. The seeds were also incubated in a gradient of phytochrome photoequilibrium at 25 °C. The highest percentage germination in this species was between 25 and 30 °C. The minimum temperature was between 15 and 20 °C and the maximum between 35 and 40 °C. Alternating temperatures did not affect the percentage of seed germination, but it did alter the rate and synchronization indexes. Seeds incubated in the dark did not germinate under any of the conditions tested, indicating that this species when cultivated present light sensitive seeds controlled by phytochrome. The seeds can tolerate a lot of shade conditions, germinating under very low fluence response of phytochrome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leukemia incidence in children has increased worldwide in recent decades, particularly due to the rise in acute lymphoblastic leukemia. Studies have associated exposure to non-ionizing radiation generated by low frequency magnetic fields with childhood leukemia. The current article reviews the case-control studies published on this subject. Of 152 articles tracked in different databases, ten studies from North America, Asia, and Europe met the defined selection criteria, with patients diagnosed from 1960 to 2004. Methodological limitations were observed in these articles, including difficulties with the procedures for assessing exposure. An association may exist between exposure to low frequency magnetic fields and acute lymphoblastic leukemia in children, but this association is weak, preventing the observation of consistency in the findings. Future studies from a wider range of geographic regions should focus on the analysis of acute lymphoblastic leukemia, which is the subtype with the greatest impact on the increasing overall incidence of childhood leukemia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We carried out a first-principles investigation on the microscopic properties of nickel-related defect centers in diamond. Several configurations, involving substitutional and interstitial nickel impurities, have been considered either in isolated configurations or forming complexes with other defects, such as vacancies and boron and nitrogen dopants. The results, in terms of spin, symmetry, and hyperfine fields, were compared with the available experimental data on electrically active centers in synthetic diamond. Several microscopic models, previously proposed to explain those data, have been confirmed by this investigation, while some models could be discarded. We also provided insights into the microscopic structure of several of those centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Empirical data indicate that the so-called ""Buddhism of yellow color"" that is predominantly associated with Japanese ""immigrant"" Buddhism, is constantly in decline in terms of ""explicit"" adherents. After some methodological observations, this article gives an overview of the relevant statistical data. The last part discusses possible reasons for these negative dynamics, referring to causes within Buddhist institutions, the ethnic community, and at the level of the individual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Patient-related variables such as physical exercise stress and fasting status are Important sources of variability in laboratory testing However no clear indications about tasting requirements exist for routine haematological tests nor has the influence of meals been assessed Methods We studied 17 healthy volunteers who consumed a light meal containing a standardized amount of carbohydrates, protein and lipids Blood was taken for routine haematological tests before the meal and 1 2 and 4 hours thereafter Results One hour after the meal neutrophil count and mean corpuscular haemoglobin (MHC) increased significantly whereas lymphocyte and monocyte counts red blood cell distribution width, haematocrit, and mean corpuscular volume decreased significantly A clinically significant variation was only observed for lymphocytes Two hours after the meal a significant increase was observed for neutrophils and MCH whereas lymphocytes eosinophils, haemoglobin and haematocrit decreased significantly Clinically significant variations were recorded for lymphocytes red blood cells (RBC), haemoglobin haematocrit and MCH Four hours after the meal MCH was significantly increased while lymphocytes eosinophils, RBC, haemoglobin and haematocrit were significantly decreased Clinically significant variations were recorded for neutrophils eosinophils RBC hematocrit and MCH Conclusion The significant variation of several haematological parameters after a light meal demonstrates that the fasting time needs to be carefully considered in order to interpret the results of haematological tests correctly

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: The aim of this study was to evaluate with light microscopy the healing process of third-degree burns on diabetic rats treated with polarized light (lambda 400-2000 nm, 20 or 40 J/cm(2)/session, 40 mW/cm(2), 2.4 J/cm(2)/min, 5.5-cm beam diameter). Background: Uncontrolled diabetes mellitus causes severe disruption of the body's metabolism, including healing. Polarized light sources have been shown to be effective in improving healing in many situations. Animals and Methods: Diabetes mellitus was induced with streptozotocin (60 mg/kg) in 45 male Wistar albino rats, and a third-degree burn (1.5 by 1.5 cm) was created on the dorsum of each animal under general anesthesia. The animals were randomly distributed into three groups: control, 20 J/cm(2), and 40 J/cm(2). Each group was then divided into three subgroups based on time of death (7, 14, 21 d). Phototherapy (20 or 40 J/cm(2) per session) was carried out immediately after the burning and repeated daily until the day before death. Following animal death, specimens were removed, embedded in paraffin, sectioned, and stained with hematoxylin and eosin (HE) or Sirius Red or immunomarked with CK AE1/AE3 antibody. Qualitative and semiquantitative analyses were performed under light microscopy. The results were statistically analyzed. Results: The animals treated with 20 J/cm(2) showed significant differences with regard to revascularization and re-epithelialization. Although the 40 J/cm(2) group showed stimulation of fibroblastic proliferation as an isolated feature, no other difference from the control was observed. Conclusion: Our results suggest that the use of polarized light at 20 J/cm(2) effectively improves the healing of third-degree burns on diabetic animals at both early and late stages of repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phototherapy is noninvasive, painless and has no known side effect. However, for its incorporation into clinical practice, more well-designed studies are necessary to define optimal parameters for its application. The viability of fibroblasts cultured under nutritional stress irradiated with either a red laser, an infrared laser, or a red light-emitting diode (LED) was analyzed. Irradiation parameters were: red laser (660 nm, 40 mW, 1 W/cm(2)), infrared laser (780 nm, 40 mW, 1 W/cm(2)), and red LED (637 +/- 15 nm, 40 mW, 1 W/cm(2)). All applications were punctual and performed with a spot with 0.4 mm(2) of diameter for 4 or 8 s. The Kruskal-Wallis test and analysis of variance of the general linear model (p <= 0.05) were used for statistical analysis. After 72 h, phototherapy with low-intensity laser and LED showed no toxicity at the cellular level. It even stimulated methylthiazol tetrazolium assay (MTT) conversion and neutral red uptake of fibroblasts cultured under nutritional stress, especially in the group irradiated with infrared laser (p = 0.004 for MTT conversion and p < 0.001 for neutral red uptake). Considering the parameters and protocol of phototherapy used, it can be concluded that phototherapy stimulated the viability of fibroblasts cultured under nutritional deficit resembling those found in traumatized tissue in which cell viability is reduced. (C) 2011 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.3602850]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study evaluated with histochemical analysis how the number of laser applications can affect the masseter muscle. Background: In dentistry today, the laser is used in patients with temporomandibular disorders (TMDs), mainly for radiating pain in the masticatory muscles, whose origins may be associated with malocclusion, although the laser effects are not well understood on the cellular level. Materials and Methods: Thirty mice (HRS/J lineage) were randomly distributed into groups according to the number of laser applications (three, six, and 10). For each group of laser applications (experimental, n = 5), it was considered the control group (n = 5), which was not irradiated. All animals inhaled halothane (2-bromo-2-chloro-1, 1, 1-trifluoroethane, minimum 99%, Sigma Aldrich, India) before each laser irradiation performed on the left masseter muscle region, on alternate days with 20 J/cm(2), 40mW, for 20 sec. The muscle samples were collected for histochemical analysis with succinate dehydrogenase (SDH) enzyme 72 h after the last application. Results: (a) A decrease in area of light fibers type (35.91% +/- 6.9%; 32.08% +/- 6.3%, and 27.88% +/- 6.3%), according to the increase of laser applications (p < 0.05); (b) significant increase (p < 0.05) in the area of intermediate fibers, with an increase of laser application (11.08% +/- 3.9%; 16.52% +/- 5.7%, and 15.96% +/- 3.9%), although the increase with 10 applications was small; (c) area increase of dark fibers in the group with three laser applications (0.16% +/- 0.3%) (p < 0.05), and in groups with six and 10 laser applications, respectively (9.68% +/- 6.0% and 9.60% +/- 4.0%). Conclusions: The SDH enzyme activity revealed that the number of laser applications increases the metabolic pattern of the muscle fibers. A minimal difference in metabolic activity between six and 10 applications of a laser suggests that further analyses should be done to confirm that six applications are enough to produce the same clinical effects, thereby contributing data to professionals from different fields in regard to the cost-benefit ratio of this therapy.