998 resultados para Analytical validation
Resumo:
Introduction: THC-COOH has been proposed as a criterion to help to distinguish between occasional from regular cannabis users. However, to date this indicator has not been adequately assessed under experimental and real-life conditions. Methods: We carried out a controlled administration study of smoked cannabis with a placebo. Twenty-three heavy smokers and 25 occasional smokers, between 18 and 30 years of age, participated in this study [Battistella G et al., PloS one. 2013;8(1):e52545]. We collected data from a second real case study performed with 146 traffic offenders' cases in which the whole blood cannabinoid concentrations and the frequency of cannabis use were known. Cannabinoid levels were determined in whole blood using tandem mass spectrometry methods. Results: Significantly high differences in THC-COOH concentrations were found between the two groups when measured during the screening visit, prior to the smoking session, and throughout the day of the experiment. Receiver operating characteristic (ROC) curves were determined and two threshold criteria were proposed in order to distinguish between these groups: a free THC-COOH concentration below 3 μg/L suggested an occasional consumption (≤ 1 joint/week) while a concentration higher than 40 μg/L corresponded to a heavy use (≥ 10 joints/month). These thresholds were successfully tested with the second real case study. The two thresholds were not challenged by the presence of ethanol (40% of cases) and of other therapeutic and illegal drugs (24%). These thresholds were also found to be consistent with previously published experimental data. Conclusion: We propose the following procedure that can be very useful in the Swiss context but also in other countries with similar traffic policies: If the whole blood THC-COOH concentration is higher than 40 μg/L, traffic offenders must be directed first and foremost toward medical assessment of their fitness to drive. This evaluation is not recommended if the THC-COOH concentration is lower than 3 μg/L. A THC-COOH level between these two thresholds can't be reliably interpreted. In such a case, further medical assessment and follow up of the fitness to drive are also suggested, but with lower priority.
Resumo:
The present study arose from the need to determine inorganic arsenic (iAs) at low levels in cereal-based food. Validated methods with a low limit of detection (LOD) are required to analyse these kinds of food. An analytical method for the determination of iAs, methylarsonic acid (MA) and dimethylarsinic acid (DMA) in cereal-based food and infant cereals is reported. The method was optimised and validated to achieve low LODs. Ion chromatography-inductively coupled plasma mass spectrometry (LC-ICPMS) was used for arsenic speciation. The main quality parameters were established. To expand the applicability of the method, different cereal products were analysed: bread, biscuits, breakfast cereals, wheat flour, corn snacks, pasta and infant cereals. The total and inorganic arsenic content of 29 cereal-based food samples ranged between 3.7-35.6 and 3.1-26.0 microg As kg-1, respectively. The present method could be considered a valuable tool for assessing inorganic arsenic contents in cereal-based foods.
Resumo:
This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.
Resumo:
The objective of this research was to develop and validate an alternative analytical method for quantitative determination of levofloxacin in tablets and injection preparations. The calibration curves were linear over a concentration range from 3.0 to 8.0 μg mL-1. The relative standard deviation was below 1.0% for both formulations and average recovery was 101.42 ± 0.45% and 100.34 ± 0.85% for tablets and injection formulations, respectively. The limit of detection and limit of quantitation were 0.08 and 0.25 μg mL-1, respectively. It was concluded that the developed method is suitable for the quality control of levofloxacin in pharmaceuticals formulations.
Resumo:
For determination of aliskiren in commercial samples, an analytical UV spectrophotometric method was developed and validate according to ICH guideline. The method was linear in the range between 40 and 100 μg mL-1 (r² = 0.9997, n = 7) and exhibited suitable specificity, accuracy, precision, and robustness. It is simple, it has low cost, and it has low use polluting reagents. Therefore, the proposed method was successfully applied for the assay and dissolution studies of aliskiren in tablet dosage forms, and the results were compared to a validated RP-LC method, showing non-significant difference (P > 0.05).
Resumo:
A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.
Resumo:
Two analytical methods were validated for determination of trichlorophenols, tetrachlorophenols and pentachlorophenol in drinking water. Limits of quantification were at least ten times lower than maximum permissible levels set by the Brazilian legislation, which are 200 ng mL-1 for 2,4,6-trichlorophenol and 9 ng mL-1 for pentachlorophenol. Chlorophenol levels were determined in tap water collected in the Municipality of Rio de Janeiro. 2,4,6-Trichlorophenol residues were detected in 36% of the samples, varying from 0.008 to 0.238 ng mL-1. All other analytes were below the limit of quantification. The validated methods showed to be suitable for application in routine quality control.
Resumo:
To assess topical delivery studies of glycoalkaloids, an analytical method by HPLC-UV was developed and validated for the determination of solasonine (SN) and solamargine (SM) in different skin layers, as well as in a topical formulation. The method was linear within the ranges 0.86 to 990.00 µg/mL for SN and 1.74 to 1000.00 µg/mL for SM (r = 0.9996). Moreover, the recoveries for both glycoalkaloids were higher than 88.94 and 93.23% from skin samples and topical formulation, respectively. The method developed is reliable and suitable for topical delivery skin studies and for determining the content of SN and SM in topical formulations.
Resumo:
Xanthyletin is used as an inhibitor of the symbiotic fungus (Leucoagaricus gongylophorus) of the leaf-cutting ant (Atta sexdens rubropilosa), one of the most significant agricultural plague insects. The incorporation of this compound into nanoparticles is a promising approach to effectively control leaf-cutting ants. This study presents the development and validation of a specific analytical method using high-performance liquid chromatography (HPLC) for quantification of the xanthyletin content in biodegradable polymeric nanoparticles. The analytical methodology developed was specific, linear, accurate, precise, and robust. The absolute recovery of xanthyletin in colloidal suspensions was nearly 100%. The HPLC method proved reliable for the quantification of xanthyletin content in nanoparticle formulations.
Resumo:
This thesis concentrates on the validation of a generic thermal hydraulic computer code TRACE under the challenges of the VVER-440 reactor type. The code capability to model the VVER-440 geometry and thermal hydraulic phenomena specific to this reactor design has been examined and demonstrated acceptable. The main challenge in VVER-440 thermal hydraulics appeared in the modelling of the horizontal steam generator. The major challenge here is not in the code physics or numerics but in the formulation of a representative nodalization structure. Another VVER-440 specialty, the hot leg loop seals, challenges the system codes functionally in general, but proved readily representable. Computer code models have to be validated against experiments to achieve confidence in code models. When new computer code is to be used for nuclear power plant safety analysis, it must first be validated against a large variety of different experiments. The validation process has to cover both the code itself and the code input. Uncertainties of different nature are identified in the different phases of the validation procedure and can even be quantified. This thesis presents a novel approach to the input model validation and uncertainty evaluation in the different stages of the computer code validation procedure. This thesis also demonstrates that in the safety analysis, there are inevitably significant uncertainties that are not statistically quantifiable; they need to be and can be addressed by other, less simplistic means, ultimately relying on the competence of the analysts and the capability of the community to support the experimental verification of analytical assumptions. This method completes essentially the commonly used uncertainty assessment methods, which are usually conducted using only statistical methods.
Resumo:
A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC) staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg) of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³), estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg), and reported as a percent (%) of the affected (left) hemisphere, correlated closely with volume (mm³, also reported as %) estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10) or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41). This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23), and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24). The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.
Resumo:
Wood-based bioprocesses present one of the fields of interest with the most potential in the circular economy. Expanding the use of wood raw material in sustainable industrial processes is acknowledged on both a global and a regional scale. This thesis concerns the application of a capillary zone electrophoresis (CZE) method with the aim of monitoring wood-based bioprocesses. The range of detectable carbohydrate compounds is expanded to furfural and polydatin in aquatic matrices. The experimental portion has been conducted on a laboratory scale with samples imitating process samples. This thesis presents a novel strategy for the uncertainty evaluation via in-house validation. The focus of the work is on the uncertainty factors of the CZE method. The CZE equipment is sensitive to ambient conditions. Therefore, a proper validation is essential for robust application. This thesis introduces a tool for process monitoring of modern bioprocesses. As a result, it is concluded that the applied CZE method provides additional results to the analysed samples and that the profiling approach is suitable for detecting changes in process samples. The CZE method shows significant potential in process monitoring because of the capability of simultaneously detecting carbohydrate-related compound clusters. The clusters can be used as summary terms, indicating process variation and drift.
Resumo:
Les pyréthrinoïdes et les pyréthrines sont des insecticides neurotoxiques auxquels on attribue également des effets néfastes sur les systèmes immunitaire, hormonal et reproducteur. Ils sont abondamment utilisés en agriculture, mais aussi en horticulture, en extermination et dans le traitement d’infestations parasitaires humaines et animales (gale, poux). Il y a donc un intérêt en santé environnementale à connaître l’ampleur de l’exposition humaine à ces pesticides. La mesure des métabolites urinaires des pyréthrinoïdes et des pyréthrines apparaît une approche de choix pour arriver à cette fin puisqu’elle permet, en théorie, d’obtenir un portrait global de l’exposition. Or,traditionnellement et par soucis de simplicité les concentrations volumiques ou ajustées pour la créatinine) de ces biomarqueurs dans des urines ponctuelles sont déterminées, mais l’effet de l’utilisation de ces unités sur la validité des estimations de dose quotidienne absorbée n’a jamais été vérifié. L’objectif général de cette thèse était donc de développer, appliquer et valider une nouvelle stratégie de mesure et d’analyse de biomarqueurs pour améliorer la précision et la fiabilité des évaluations de l’exposition individuelles et populationnelles aux pyréthrinoïdes et pyréthrines. Les objectifs spécifiques étaient : i) de caractériser l’exposition humaine à ces contaminants en région urbaine et rurale au Québec et ii) de comparer la validité de la nouvelle stratégie de mesure et d’analyse de biomarqueurs urinaires proposée avec les autres méthodes plus usuelles utilisées pour estimer l’exposition individuelle et populationnelle et les doses absorbées de pyréthrinoïdes. Des adultes et des enfants, recrutés dans la population de l’Île de Montréal et de la Montérégie ont recueilli leurs urines pendant une période d’au moins douze heures et complété un questionnaire documentant les sources potentielles d’exposition. Les quantités de métabolites de pyréthrinoïdes et pyréthrines (pmol) mesurées dans les urines ont été ajustées pour une période de douze heures exactement et pour le poids corporel. Les quantités excrétées en région urbaine ont été comparées à celles excrétées en région rurale et les données individuelles et populationnelles ont été comparées à celles qui auraient été obtenues si des concentrations volumiques ou ajustées pour la créatinine avaient été mesurées. Les résultats montrent que l’exposition à ces pesticides est ubiquiste puisque plus de 90% des participants excrétaient les principaux métabolites de pyréthrinoïdes et pyréthrines à un niveau supérieur au seuil de détection analytique. Les résultats suggèrent que l’alimentation pourrait être à l’origine de ce niveau de base puisque les autres sources d’exposition connues n’ont été que rarement rapportées. Au Québec, l’exposition en milieu rural apparaissait légèrement plus importante qu’en milieu urbain et certains facteurs d’exposition, comme l’utilisation de pesticides domestiques, ont été rapportés plus fréquemment en milieu rural. Enfin, il a été démontré que la mesure des concentrations volumiques ou ajustées pour la créatinine de biomarqueurs est une approche qui peut entraîner des biais importants (jusqu’à 500% d’erreur et plus) en particulier lors de l’évaluation de l’exposition individuelle. Il est évident que les autorités de santé publique et de santé environnementale employant des biomarqueurs urinaires afin d’évaluer l’exposition aux pyréthrinoïdes et aux pyréthrines (ainsi qu’à d’autres molécules ayant des demi-vies d’élimination similaire)devraient diriger leurs efforts vers la mesure des quantités excrétées pendant une période d’au moins douze heures pour obtenir un portrait le plus valide possible de l’exposition. Il serait aussi souhaitable de mieux documenter la toxicocinétique de ces molécules chez l’humain afin d’établir avec une plus grande confiance la relation entre les quantités excrétées de biomarqueurs et les doses absorbées de ces contaminants.
Resumo:
Les tests PAMPA et les tests Caco-2 sont des essais in vitro de l’évaluation de la perméabilité intestinale des médicaments. Ils sont réalisés lors de la phase de découverte du médicament. Les tests PAMPA ne sont pas biologiquement représentatifs de la paroi intestinale, mais ils sont rapides et peu coûteux. Les tests Caco-2 nécessitent plus de 21 jours pour la culture cellulaire et des installations spécifiques sont requises. Ils sont constitués d’une monocouche d’entérocytes à confluence et donc plus biologiquement représentatifs. Il y a un besoin pour le développement d’un essai qui est biologiquement représentatif de la membrane intestinale humaine, rapide et peu coûteux. Le premier but de ce projet était de développer une méthode analytique qui permettrait l’évaluation simultanée de huit médicaments témoins utilisés pour la validation de l’essai de perméabilité. Le deuxième but de ce projet était donc d’améliorer la membrane des tests PAMPA pour proposer un nouveau test : le néoPAMPA. Contrairement au test PAMPA traditionnel, cette membrane est constituée de trois composantes : (1) un filtre poreux qui agit à titre de support, (2) un coussin polydopamine chargé négativement qui sert d’ancrage et qui assure la fluidité de la bicouche et (3) une bicouche lipidique formée par fusion de vésicules. Une méthode analytique HPLC-MS/MS a été validée selon les spécifications de la FDA et de la EMA. Cette méthode a permis de quantifier simultanément les huit médicaments standards utilisés pour le test néoPAMPA. Le test PAMPA traditionnel a été mis en place à titre d’essai control. Les coefficients de perméabilité mesurés pour les huit médicaments au travers de la membrane PAMPA comparaient favorablement aux résultats de la littérature. Les composantes de la membrane néoPAMPA ont été optimisées. Les conditions optimales retenues étaient les filtres de polycarbonate hydrophile ayant des pores de 15 nm, les plaques Costar 12 puits comme dispositif des tests de perméabilité, une bicouche lipidique composée de 70 % DOPC et de 30 % cholestérol cationique ainsi qu’une déposition des liposomes en présence de 150 mM NaCl suivi d’un équilibre d’1 h en présence d’une solution saturée en DOPC. Les stabilités de la cassette de médicaments et des liposomes sont insuffisantes pour le conditionnement commercial des membranes néoPAMPA. Les différentes optimisations réalisées ont permis d’améliorer la membrane néoPAMPA sans toutefois la rendre fonctionnelle. La membrane néoPAMPA n’est toujours pas en mesure de discriminer des molécules en fonction de leur perméabilité attendue.
Resumo:
Caches are known to consume up to half of all system power in embedded processors. Co-optimizing performance and power of the cache subsystems is therefore an important step in the design of embedded systems, especially those employing application specific instruction processors. In this project, we propose an analytical cache model that succinctly captures the miss performance of an application over the entire cache parameter space. Unlike exhaustive trace driven simulation, our model requires that the program be simulated once so that a few key characteristics can be obtained. Using these application-dependent characteristics, the model can span the entire cache parameter space consisting of cache sizes, associativity and cache block sizes. In our unified model, we are able to cater for direct-mapped, set and fully associative instruction, data and unified caches. Validation against full trace-driven simulations shows that our model has a high degree of fidelity. Finally, we show how the model can be coupled with a power model for caches such that one can very quickly decide on pareto-optimal performance-power design points for rapid design space exploration.