Development and validation of a stability-indicating HPLC method for the determination of buclizine hydrochloride in tablets and oral suspension and its application to dissolution studies


Autoria(s): Kuminek,Gislaine; Stulzer,Hellen K.; Tagliari,Monika P.; Oliveira,Paulo R.; Bernardi,Larissa S.; Rauber,Gabriela; Cardoso,Simone G.
Data(s)

01/01/2012

Resumo

A method using liquid chromatography has been developed and validated for determination of buclizine in pharmaceutical formulations and in release studies. Isocratic chromatography was performed on a C18 column with methanol:water (80:20 v/v, pH 2.6) as mobile phase, at a flow rate of 1.0 mL/min, and UV detection at 230 nm. The method was linear, accurate, precise, sensible and robust. The dissolution test was optimized and validated in terms of dissolution medium, apparatus agitation and rotation speed. The presented analytical and dissolution procedures can be conveniently adopted in the quality and stability control of buclizine in tablets and oral suspension.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000100036

Idioma(s)

en

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.35 n.1 2012

Palavras-Chave #buclizine #dissolution test #liquid chromatography
Tipo

journal article