The increased surface area of copper electrodes upon applying a suitable potential protocol was characterized by atomic force microscopy images. Scanning electrochemical microscopy was used to demonstrate the enhanced reactivity of the generated surface. The modified electrode showed excellent catalytic activity towards nitrite reduction in acidic medium (pH 2). This new platform was used in the development of a fast and simple voltammetric method for nitrite determination. Commercial and rainwater spiked samples were analyzed and the data showed an excellent agreement with those obtained with a reference spectrophotometric method (Griess reaction) at a confidence level of 95% (Student`s t-test).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An alternative method for determination of total trans fatty acids expressed as elaidic acid by capillary zone electrophoresis (CZE) under indirect UV detection at 224 nm within an analysis time of 7.5 min was developed. The optimized running electrolyte includes 15.0 mmol L(-1) KH(2)PO(4)/Na(2)HPO(4) buffer (pH similar to 7.0), 4.0 mmol L(-1) SDBS, 8.0 mmol L(-1) Brij35, 45%v/v ACN, 8% methanol, and 1.5% v/v n-octanol. Baseline separation of the critical pair C18-9cis/C18:1-9t: with a resolution higher than 1.5 was achieved using C15:0 as the internal standard. The optimum capillary electrophoresis (CE) conditions for the background electrolyte were established with the aid of Raman spectroscopy and experiments of a 3(2) factorial design. After response factor (R(F)) calculations, the CE method was applied to total trans fatty acid (TTFA) analysis in a hydrogenated vegetable fat (HVF) sample, and compared with the American Oil Chemists` Society (AOCS) official method by gas chromatography (GC). The methods were compared with an independent sample t test, and no significant difference was found between CE and GC methods within the 95% confidence interval for six genuine replicates of TTFA analysis (p-value > 0.05). The CE method was applied to TTFA analysis in a spreadable cheese sample. Satisfactory results were obtained, indicating that the optimized methodology can be used for trans fatty acid determination for these samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method for the simultaneous determination of the stilbene resveratrol, four phenolic acids (syringic, coumaric, caffeic, and gallic acids), and five flavonoids (catechin, rutin, kaempferol, myricetin, and quercetin) in wine by CE was developed and validated. The CE electrolyte composition and instrumental conditions were optimized using 2(7-3) factorial design and response surface analysis, showing sodium tetraborate, MeOH, and their interaction as the most influential variables. The optimal electrophoretic conditions, minimizing the chromatographic resolution statistic values, consisted of 17 mmol/L sodium tetraborate with 20% methanol as electrolyte, constant voltage of 25 kV, hydrodynamic injection at 50 mbar for 3 s, and temperature of 25 degrees C. The R(2) values for linearity varied from 0.994 to 0.999; LOD and LOQ were 0.1 to 0.3 mg/L and 0.4 to 0.8 mg/L, respectively. The RSDs for migration time and peak area obtained from ten consecutive injections were less than 2% and recoveries varied from 97 to 102%. The method was applied to 23 samples of inexpensive Brazilian wines, showing wide compositional variation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to develop a fast capillary electrophoresis method for the determination of benzoate and sorbate ions in commercial beverages. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. As the high resolution obtained experimentally for sorbate and benzoate in the studies presented in the literature is not in agreement with that expected from the ionic mobility values published, a procedure to determine these values was carried out. The salicylate ion was used as the internal standard. The background electrolyte was composed of 25 mmol L(-1) tris(hydroxymethyl)aminomethane and 12.5 mmol L(-1) 2-hydroxyisobutyric acid, atpH 8.1.Separation was conducted in a fused-silica capillary(32 cm total length and 8.5 cm effective length, 50 mu m I.D.), with short-end injection configuration and direct UV detection at 200 nm for benzoate and salicylate and 254 nm for sorbate ions. The run time was only 28 s. A few figures of merit of the proposed method include: good linearity (R(2) > 0.999), limit of detection of 0.9 and 0.3 mg L(-1) for benzoate and sorbate, respectively, inter-day precision better than 2.7% (n =9) and recovery in the range 97.9-105%. Beverage samples were prepared by simple dilution with deionized water (1:11, v/v). Concentrations in the range of 197-401 mg L(-1) for benzoate and 28-144 mg L(-1) for sorbate were found in soft drinks and tea. (c) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical detection of the hazardous pollutant 4-nitrophenol (4-NP) at low potentials, in order to avoid matrix interferences, is an important research challenge. This study describes the development, electrochemical characterization and utilization of a multiwall carbon nanotube (MWCNT) film electrode for the quantitative determination of 4-NP in natural water. Electrochemical impedence spectroscopy measurements showed that the modified surface exhibits a decrease of ca. 13 times in the charge transfer resistance when compared with a bare glassy carbon (GC) surface. Voltammetric experiments showed the possibility to oxidize a hydroxylamine layer (produced by the electrochemical reduction of 4-NP on the GC/MWNCT surface) in a potential region which is approximately 700 mV less positive than that needed to oxidize 4-NP, thus minimizing the interference of matrix components. The limit of detection for 4-NP obtained using square-wave voltammetry (0.12 mu mol L(-1)) was lower than the value advised by EPA. A natural water sample from a dam located in Sao Carlos (Brazil) was spiked with 4-NP and analyzed by the standard addition method using thee GC/MWCNT electrode, without any further purification step. the recovery procedure yielded a value of 96.5% for such sample, thus confirming the suitability of the developed method to determine 4-NP in natural water samples. The electrochemical determination was compared with that obtained by HPLC with UV-vis detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several colorimetric and chromatographic methods have been used for the identification and quantification of methyldopa (MA) in pharmaceutical formulations and clinical samples. However, these methods are time- and reagent-consuming, which stimulated our efforts to develop a simple, fast, and low-cost alternative method. We carried out an electroanalytical method for the determination of MA in pharmaceutical formulations using the crude enzymatic extract of laccase from Pycnoporus sanguineus as oxidizing agent. This method is based on the biochemical oxidation of MA by laccase (LAC), both in solution, followed by electrochemical reduction on glassy carbon electrode surface. This method was employed for the determination of MA in pure and pharmaceutical formulations and compared with the results obtained using the official method. A wide linear curve from 23 x 10(-5) to 1 x 10(-4) mol L(-1) was found with a detection limit calculated from 43 x 10(-6) mol L(-1).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A graphite-polyurethane composite electrode has been used for the determination of furosemide, a antihypertensive drug, in pharmaceutical samples by anodic oxidation. Cyclic voltammetry and electrochemical impedance spectroscopy were used to characterize the electrooxidation process at +1.0 V vs. SCE over a wide pH range, with the result that no adsorption of analyte or products occurs, unlike at other carbon-based electrode materials. Quantification was carried out using cyclic voltammetry, differential pulse voltammetry, and square-wave voltammetry. Linear ranges were determined (up to 21 mu mol L-1 with cyclic voltammetry) as well as limits of detection (0.15 mu mol L-1 by differential pulse voltammetry). Four different types of commercial samples were successfully analyzed. Recovery tests were performed which agreed with those obtained by spectrophotometric evaluation. The advantages of this electrode material for repetitive analyzes, due to the fact that no electrode surface renewal is needed owing to the lack of adsorption, are highlighted.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The electrochemical methods cyclic and square-wave voltammetry were applied to develop an electroanalytical procedure for the determination of N-nitrosamines (N-nitrosopyrrolidine, N-nitrosopiperidine and N-nitrosodiethylamine) in aqueous solutions. Cyclic voltammetry was used to evaluate the electrochemical behaviors of N-nitrosamines on boron-doped diamond electrodes. It was observed an irreversible electrooxidation peak located in approximately 1.8 V (vs. Ag/AgCl) for both N-nitrosamines. The optimal electrochemical response was obtained using the following square-wave voltammetry parameters: f = 250 Hz, E(sw) = 50 mV and E(s) = 2 mV using a Britton-Robinson buffer solution as electrolyte (pH 2). The detection and quantification limits determined for total N-nitrosamines were 6.0 x 10(-8) and 2.0 x 10(-7) mol L(-1), respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A solid graphite-polyurethane composite electrode has been used to determine release profiles of verapamil, a calcium-channel blocker. The electro-oxidation process was characterized by cyclic voltammetry and electrochemical impedance spectroscopy and showed no adsorption of analyte or oxidation products, unlike at other carbon-based electrodes. Quantification gave linear ranges up to 40molL-1 with cyclic voltammetry and detection limits of 0.7molL-1 by differential pulse and square-wave voltammetry. Commercial product samples were successfully analyzed with results equal to those from spectrophotometry. Because no electrode surface renewal is needed, this electrode material has many advantages.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microwave-assisted sample preparation using diluted nitric acid solutions is an alternative procedure for digesting organic samples. The efficiency of this procedure depends on the chemical properties of the samples and in this work it was evaluated by the determination of crude protein amount. fat and original carbon. Soybeans grains, bovine blood. bovine muscle and bovine viscera were digested in a cavity-microwave oven using oxidant mixtures in different acid concentrations. The digestion efficiency was evaluated based on the determination of residual carbon content and element recoveries using inductively coupled plasma optical emission spectrometry (ICP OES). In order to determine the main residual organic compounds, the digests were characterized by nuclear magnetic resonance (1 H NMR). Subsequently, studies concerning separation of nitrobenzoic acid isomers were performed by ion pair reversed phase liquid chromatography using a C18 stationary phase, water:acetonitrile:methanol (75:20:5, v/v/v) +0.05% (v/v) TFA as mobile phase and ultraviolet detection at 254 nm. Sample preparation based on diluted acids proved to be feasible and a recommendable alternative for organic sample digestion, reducing both the reagent volumes and the variability of the residues as a result of the process of decomposition. It was shown that biological matt-ices containing amino acids, proteins and lipids in their composition produced nitrobenzoic acid isomers and other organic compounds after cleavage of chemical bonds. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple and highly selective electrochemical method was developed for the single or simultaneous determination of paracetamol (N-acetyl-p-aminophenol, acetaminophen) and caffeine (3,7-dihydro-1,3,7-trimethyl-1H-purine-2,6-dione) in aqueous media (acetate buffer, pH 4.5) on a boron-doped diamond (BDD) electrode using square wave voltammetry (SWV) or differential Pulse voltammetry (DPV). Using DPV with the cathodically pre-treated BDD electrode, a separation of about 550 mV between the peak oxidation potentials Of paracetamol and caffeine present in binary mixtures was obtained. The calibration curves for the simultaneous determination of paracetamol and caffeine showed an excellent linear response, ranging from 5.0 x 10(-7) mol L(-1) to 8.3 x 10(-7) mol L(-1) for both compounds. The detection limits for the simultaneous determination of paracetamol and caffeine were 4.9 x 10(-7) mol L-1 and 3.5 x 10(-8) mol L(-1), respectively. The proposed method Was Successfully applied in the simultaneous determination of paracetamol and caffeine in several pharmaceutical formulations (tablets), with results similar to those obtained using a high-performance liquid chromatography method (at 95% confidence level). (C) 2008 Elsevier BY. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although potassium permanganate [Mn(VII)] has been used extensively as a chemiluminescence reagent for many decades, other manganese-based oxidants have only recently been explored for this purpose. There is strong evidence to suggest that, like permanganate, manganese(III) and manganese(IV) oxidants react with many molecules to produce an excited manganese(II) species that emits light. However, these reagents differ markedly in terms of selectivity, and possess characteristics that provide new avenues for detection, such as the immobilisation of solid manganese dioxide, the production of ‘soluble’ manganese(IV) nanoparticles, and the electrochemical generation of manganese(III). In this review we examine the emergence of these alternative manganese oxidants as chemiluminescence reagents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Polystyrene behaviour in reversed phase high performance liquid chromatography was influenced mainly by the solvent system, but secondary affects were observed depending on the stationary phase. A variety of reversed phase columns were investigated using mobile phase combinations of dichlorom ethane-methanol, dichloromethane-acetonitrile, ethyl acetate-methanol and ethyl acetate-acetonitrile. Several different modes of behaviour were observed depending on the polymer solubility in the solvent system. In the dichloromethane-methanol solvent system, polymer-stationary phase interactions only occurred when the molecules had pore access. Retention of excluded polystyrene depended on the kinetics of precipitation and redissolution of the polymer. Peak splitting and band broadening occurred when the kinetics were slow and molecular weight separations were limited !o oligomers and polystyrenes lower than 5-10(4) dalton. Excellent molecular weight separations of polystyrenes were obtained using gradient elution reversed phase chromatography with a dichloromethane-acetonitrile mobile phase on C18 columns. The retention was based on polymer-stationary phase interactions regardless of the column pore size. Separations were obtained on large diameter pellicular adsorbents that were almost as good as those obtained on porous adsorbents, showing that pore access was not essential for the retention of high molecular weight polystyrenes. In the best example, the separation ranged from the monomer to 10(6) dalton in a single analysis. Very little adsorption of excluded polymers was observed on C8 or phenyl columns. Polystyrene molecular weight separations to 7-10(5) dalton were obtained in an ethyl acetate-acetonitrile solvent system on C18 columns. Adsorption was responsible for retention. When an ethyl acetate-methanol solvent system was used, no molecular weight separations were obtained because of complex peak splitting. Reversed phase chromatography was compared to size exclusion chromatography for the analysis of polydisperse polystyrenes. Similar results were obtained using both methods. However, the reversed phase method was less sensitive to concentration effects and gave better resolution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of anabolic steroids often requires the use of elaborate techniques such as gas chromatography - mass spectrometry (GC-MS), gas liquid chromatography (GLC) and more recently high performance liquid chromatography (HPLC). Most of these methods employ derivatisation techniques prior to detection which makes them tedious and relatively time consuming. Other methods demand a great deal of skill. A simple and rapid analytical method, based on differential pulse polarography at a dropping mercury electrode has been developed for the determination of various anabolic steroids in a range of commercially available pharmaceutical preparations. Detailed investigation of the electrochemical behaviour of these steroids was made in order to elucidate the electrode processes involved, in addition to optimising the method. Several other analytical methods such as GC-MS, NMR, ultraviolet (UV), infrared (IR) spectroscopy were also used to confirm the products of the chemical and electrochemical reactions. Possible reactions are suggested. Various extraction procedures were examined for separation of selected steroids from the oil-based or pill matrix and their suitability for polarographic determination is discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A protocol for culturing mammalian type 1 astrocytic cells, using female post-natal rat cerebral cortical tissue, was established and refined for use in steroidogenic metabolic studies incorporating progestin radioisotopes. Cultures were characterised for homogeneity using standard morphological and immunostaining techniques. Qualitative and quantitative studies were conducted to characterise the progesterone (P) metabolic pathways present in astrocytes in vitro. Of particular interest was the formation of the P metabolite, 5á-pregnan-3á-ol-20-one (THP). THP is a GABA(A) receptor agonist, believed to play a vital role in neural functioning and CNS homeostasis. One aim of this study was to observe any modulatory effects selected neuroactive ligands have on the conversion of P into THP, in an attempt to link astrocytic steroidogenesis with neuronal control. In qualitative studies, chromatographic procedures were used to establish the progestin profile of cerebral cortical astrocytes. Tritiated P, DHP (5á-pregnan-3,20-dione) and THP incurbates were preliminary fractionated by either normal phase (NP) or reverse phase (RP) high performance liquid chromatography (HPLC). The radiometabolites associated with each fraction were further chromatographed, before and/or after chemical derivatistation, by the aforemention HPLC procedures and thin layer chromatography (TLC). Steroid radiometabolites were tentatively identified by comparing their chromatographic mobility with authentic steroids. The identity of the main putative 5á-reduced P metabolities, DHP, THP and 5á-pregnan-3á,20á-diol (20áOH-THP) were further confirmed by isotopic dilution analysis. Their conclusive identification, along with the tentative identification of 20á-hydroxypreg-4-en-3-one (20áOH-P) and 20á-hydroxy-5á-pregnan-3-one (20áOH-DHP), verify the localisation of 5á-reductase, 3á-hydroxy steroif oxidoreductase (HSOR), and 20á-HSOR activity in the cultured astrocytes utilised in this study programme. Other minor metabolites detected were tentatively identified, including 5á-pregnan-3á,21-diol-20-one (THDoc), indicating the presence of 21-hydroxylase enzymatic activity. THDoc, like THP, is a GABA(A) receptor agonist. The chemical and physical characterisation of several yet unidentified progestin metabolites, associated with a highly polar RP HPLC fraction (designated RP peak 1*), indicate the presence of one or more extra hydroxylase enzymes. Quantitative analysis included a preliminary study. In this study, the percentage yields of radiometabolites formed in cultures incubated with increasing substrate concentrations of (3)H-P for 24 hours were determined. At the lower concentrations examined (ie 0.5 to 50nM), the metabolites associated with the polar RP HPLC fraction (RP peak 1*) collectively have the highest percentage yield. They are subsequently considered metabolic end products of degradative catabolic P pathways. The percentage yield of THP peaks in the medium concentration ranges (ie 5 to 500nM), whereas DHP remains fairly static at a low level with increasing concentration. Both DHP and THP are considered metabolic pathway intermediates. The percentage yield of 20áOH-THP continues to increase with increasing concentration over 5nM, superseding THP approaching the highest concentration examined (5000nM). This indicated the formation of 20áOH-THP does not occur entirely via THP. 20áOH-THP also possibly serves as the direct intermediate in the formation of the main radiometabolites associated with RP peak 1*. A time/yield study incorporating incubation times from one to 24 hours was also conducted. The full array of radiometabolites (individually or in groups) formed in astrocyte cultures incubated with 50nM tritiated P, DHP of THP, were assayed. Cultures were observed to rapidly convert any DHP into THP, showing astrocytic 3á-HSOR activity is very high. The study also showed 5á-reduction (ie the conversation of P into DHP) is the rate limiting reaction in the two step conversion of P into THP. 5á-Reduction also appears to be a rate limiting step in the formation of 20á-hydroxylated metabolites in astrocytes. Cultures incubated with the tritiated 5á-reduced pregnanes from one to four hours form greater quantities to 20á-hydroxylated radiometabolites compared to cultures incubated with (3)H-P. The time yield/studies also provided further evidence the unidentified polar radiometabolites associated with RP peak 1* are metabolic end products. For the P and DHP incubates, the collective formation of the aforementioned polar radiometabolites initially lags behind the formation of THP. As the formation of the latter begins to plateau with increasing time between four to 24 hours, the net yield of radiometabolites associated with RP peak 1* continues to rise. The time/yield studies also indicate 5á-reduction and perhaps 3á-hydroxylation are pre-requisite steps in the formation of the polar metabolites. Cultures incubated with the 5á-reduced progestins from one to four hours form higher yields of the radiometabolites associated with RP peak 1* compared to cultures incubated with P as substrate. The net yields of the radiometabolites associated with RP peak 1* for cultures incubated with THP were substantially higher compared to cultures incubated with DHP after equivalent times. The effect selected neuroligands have on the yield of radiometabolites formed by cultured astrocytes incubated with 50nM (3)H-P was also examined. Dibutyryl cyclic adenosine monophosphate (DBcAMP), not actually a neuroligand per se, but an analog of the intracellular secondary messenger cAMP, was also utilised in these studies. The inhibitory neurotransmitter ă-amino-nbutyric acid (GABA), DBcAMP and isoproterenol (a â-adrenergic receptor agonist) all quickly induce a transient but substantial increase in 20á-HSOR activity in cultured astrocytes. Cultures pretreated with these three compounds (10, 20 and 1µM respectively) form substantially higher yields of 20á-hydroxylated metabolites, including 20áOH-THP (between 200 to 580% greater), when incubated with 50nM (3)H-P for one to four hours. These increases also coincide with increases in the net yield of metabolites formed (by 16 to 48%). The same pre-treated cultures form significantly lower yields of THP, by 25 to 41%, after one hour. This is most likely due to the increased metabolism of any formed THP into 20áOH-THP. Octopamine (an á-adrenergic agonist) only induces a slight increase in 20á-HSOR activity, having relatively little effect on the yield of 20áOH-THP formed. Pretreatment with octopamine induces a significant increase in the yield of THP for cultures incubated with (3)H-P for four hours (by 24%). The increase in THP formation appears to be due to an increase in 3á-HSOR activity, as judged by the concomitant drop in the yield of the 5á-reduced, 3-keto substrates. An increase in 5á-reductase activity cannot be excluded however. Isoproterenol appears to induce an increase in 5á-reductase activity as isoproterenol appears to induce an increase in 5á-reductase activity as isoproterenol one and four hour incubates have higher yields of DHP. This is in contrast to the other three incubates. After 12 hours, all incubates have higher yields of THP (15-30%).