Development of a rapid column-switching LC-MS/MS method for the quantification of THCCOOH and THCCOOH-glucuronide in whole blood for assessing cannabis consumption frequency


Autoria(s): Hädener, Marianne; Weinmann, Wolfgang; Schürch, Stefan; König, Stefan
Data(s)

18/01/2016

31/12/1969

Resumo

The concentration of 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol (THCCOOH) in whole blood is used as a parameter for assessing the consumption behavior of cannabis consumers. The blood level of THCCOOH-glucuronide might provide additional information about the frequency of cannabis use. To verify this assumption, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the rapid and direct quantification of free and glucuronidated THCCOOH in human whole blood was newly developed. The method comprised protein precipitation, followed by injection of the processed sample onto a trapping column and subsequent gradient elution to an analytical column for separation and detection. The total LC run time was 4.5 min. Detection of the analytes was accomplished by electrospray ionization in positive ion mode and selected reaction monitoring using a triple-stage quadrupole mass spectrometer. The method was fully validated by evaluating the following parameters: linearity, lower limit of quantification, accuracy and imprecision, selectivity, extraction efficiency, matrix effect, carry-over, dilution integrity, analyte stability, and re-injection reproducibility. All acceptance criteria were analyzed and the predefined criteria met. Linearity ranged from 5.0 to 500 μg/L for both analytes. The method was successfully applied to whole blood samples from a large collective of cannabis consumers, demonstrating its applicability in the forensic field.

Formato

application/pdf

application/pdf

Identificador

http://boris.unibe.ch/75433/1/art%253A10.1007%252Fs00216-016-9311-8.pdf

http://boris.unibe.ch/75433/8/H%C3%A4dener_ABC%202016_THCCOOH-Gluc%20LCMSMS_accepted.pdf

Hädener, Marianne; Weinmann, Wolfgang; Schürch, Stefan; König, Stefan (2016). Development of a rapid column-switching LC-MS/MS method for the quantification of THCCOOH and THCCOOH-glucuronide in whole blood for assessing cannabis consumption frequency. Analytical and bioanalytical chemistry, 408(7), pp. 1953-1962. Springer 10.1007/s00216-016-9311-8 <http://dx.doi.org/10.1007/s00216-016-9311-8>

doi:10.7892/boris.75433

info:doi:10.1007/s00216-016-9311-8

info:pmid:26781107

urn:issn:1618-2642

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/75433/

Direitos

info:eu-repo/semantics/restrictedAccess

info:eu-repo/semantics/embargoedAccess

Fonte

Hädener, Marianne; Weinmann, Wolfgang; Schürch, Stefan; König, Stefan (2016). Development of a rapid column-switching LC-MS/MS method for the quantification of THCCOOH and THCCOOH-glucuronide in whole blood for assessing cannabis consumption frequency. Analytical and bioanalytical chemistry, 408(7), pp. 1953-1962. Springer 10.1007/s00216-016-9311-8 <http://dx.doi.org/10.1007/s00216-016-9311-8>

Palavras-Chave #570 Life sciences; biology #540 Chemistry #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed