922 resultados para value systems alignment


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An increasing number of studies have shown altered expression of secreted protein acidic and rich in cysteine (SPARC) and N-myc down-regulated gene (NDRG1) in several malignancies, including breast carcinoma; however, the role of these potential biomarkers in tumor development and progression is controversial. In this study, NDRG1 and SPARC protein expression was evaluated by immunohistochemistry on tissue microarrays containing breast tumor specimens from patients with 10 years of follow-up. NDRG1 and SPARC protein expression was determined in 596 patients along with other prognostic markers, such as ER, PR, and HER2. The status of NDRG1 and SPARC protein expression was correlated with prognostic variables and patient clinical outcome. Immunostaining revealed that 272 of the 596 cases (45.6%) were positive for NDRG1 and 431 (72.3%) were positive for SPARC. Statistically significant differences were found between the presence of SPARC and NDRG1 protein expression and standard clinicopathological variables. Kaplan-Meier analysis showed that NDRG1 positivity was directly associated with shorter disease-free survival (DFS, P < 0.001) and overall survival (OS, P < 0.001). In contrast, patients expressing low levels of SPARC protein had worse DFS (P = 0.001) and OS (P = 0.001) compared to those expressing high levels. Combined analysis of the two markers indicated that DFS (P < 0.001) and OS rates (P < 0.001) were lowest for patients with NDRG1-positive and SPARC-negative tumors. Furthermore, NDRG1 over-expression and SPARC down-regulation correlated with poor prognosis in patients with luminal A or triple-negative subtype breast cancer. On multivariate analysis using a Cox proportional hazards model, NDRG1 and SPARC protein expression were independent prognostic factors for both DFS and OS of breast cancer patients. These data indicate that NDRG1 over-expression and SPARC down-regulation could play important roles in breast cancer progression and serve as useful biomarkers to better define breast cancer prognosis.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Heart transplantation (OHT) has traditionally been contraindicated in the presence of severe pulmonary hypertension (PH), as detected by right heart catheterization. Noninvasive methods are still not reliably accurate to make this evaluation. Objectives. Determine the efficacy of echo Doppler analysis for the diagnosis of severe PH. Methods. One hundred thirty patients (mean age = 42 +/- 15 years, 82 men) showed severe left ventricular dysfunction (mean ejection fraction = 29 +/- 12%; functional class III-IV). We excluded patients with atrial fibrillation, heart failure secondary to congenital disease, and valvulopathy. The pulmonary parameters defined as severe PH were: systolic pulmonary artery pressure (sPAP) >= 60 mm Hg; a mean transpulmonary gradient >= 15; or pulmonary vascular resistance >= 5 Wood units. Patients underwent a right heart catheterization using a Swan-Ganz catheter to measure hemodynamic parameters and to noninvasively estimate right-sided pressures from spectral Doppler recordings of tricuspid regurgitation velocity (right ventricular systolic pressure [RVsP]). A Pearson correlation of sPAP was obtained with RVsP by; the sensitivity of RVsP for the diagnosis of PH was determined by a receiver operating characteristic (ROC) curve. Results. A good correlation between sPAP and RVsP was obtained by Pearson correlation analysis (r = 0.64; 95% confidence interval [CI] 0.50-0.75; P < .001). The ROC curve analysis showed a sensitivity of 100%, a specificity of 37.2%, (95% CI 0.69-0.83, P < .0001) of a RVsP < 45 mm Hg (cutoff) on the exclusion of severe PH. Conclusions. The cutoff of RVsP < 45 mm Hg, on noninvasive echo Doppler evaluation of PH is an efficient method to replace invasive heart catheterization in OHT candidates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to investigate the impact of acute PaCO(2) temporal variation on the standard base excess (SBE) value in critically ill patients. Methods: A total of 265 patients were prospectively observed; 158 were allocated to the modeling group, and 107 were allocated to the validation group. Two models were developed in the modeling group (one including and one excluding PaCO(2) as a variable determinant of SBE), and both were tested in the validation group. Results: In the modeling group, the mathematical model including SIDai, SIG, L-lactate, albumin, phosphate, and PaCO(2) had a predictive superiority in comparison with the model without PaCO(2) (R(2) = 0.978 and 0.916, respectively). In the validation group, the results were confirmed with significant F change statistics (R(2) change = 0.059, P < .001) between the model with and without PaCO(2). A high correlation (R = 0.99, P < .001) and agreement (bias = -0.25 mEq/L, limits of agreement 95% = -0.72 to 0.22 mEq/L) were found between the model-predicted SBE value and the SBE calculated using the Van Slyke equation. Conclusions: Acute PaCO(2), temporal variation is related to SBE changes in critically ill patients. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To determine if knee alignment measures differ between African Americans and Caucasians without radiographic knee osteoarthritis (rOA). Methods. A single knee was randomly selected from 175 participants in the Johnston County Osteoarthritis Project without rOA in either knee. Anatomic axis, condylar, tibia] plateau, and condylar plateau angles were measured by I radiologist; means were compared and adjusted for age and body mass index (BMI). Results. There were no significant differences in knee alignment measurements between Caucasians and African Americans among men or women. Conclusion. Observed differences in knee rOA occurrence between African Americans and Caucasians are not explained by differences in static knee alignment. (First Release July 15 2009; J Rheumatol 2009;36:1987-90; doi: 10.3899/jrheum.081294)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Objectives: Some authors states that the removal of lymph node would only contribute towards assessing the lymph node status and regional disease control, without any benefit for the patients` survival. The aim of this paper was to assess the influence of the number of surgically dissected pelvic lymph nodes (PLN) on disease-free Survival. Methods: Retrospective cohort study on 42 women presenting squamous cell carcinoma (SCC) of the uterine cervix, with metastases in PLN treated by radical surgery. The Cox model was used to identify risk factors for recurrence. The model variables were adjusted for treatment-related factors (year of treatment, surgical margins and postoperative radiotherapy). The cutoff value for classifying the lymphadenectomy as comprehensive (15 PLN or more) or non-comprehensive (<15 PLN) was determined from analysis of the ROC curve. Results: Fourteen recurrences (32.6%) were recorded: three pelvic, eight distant, two both pelvic and distant, and one at an unknown location. The following risk factors for recurrence were identified: invasion of the deep third of the cervix and number of dissected lymph nodes <15. Conclusions: Deep invasion and non-comprehensive pelvic lymphadenectomy are possible risk factors for recurrence of SCC of the uterine cervix with metastases in PLN. J. Surg. Oncol. 2009;100:252-257. (C) 2009 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The most common laparoscopic complications are associated with trocar insertion. The purpose of this study was to develop an objective method of evaluating the safety profile of various access devices used in laparoscopic surgery. STUDY DESIGN: In 20 swine, 6 bladed and 2 needle access devices were evaluated. A force profile was determined by measuring the force required to drive the trocar or needle through the fascia and into the peritoneum, at 0 and 10 mmHg. The amount Of tissue deformation, the length of blade exposed, and the duration of exposure were measured using a high-speed digital imaging system. RESULTS: The needle system without the sheath required the least driving force and had the most favorable force profile. In contrast, the bladed, nonretractable trocar system required a higher driving force and a rapid loss of resistance. Insertion under a pneumoperitoneum did not significantly alter the force profile of the various access devices except for the amount of tissue deformation. With the bladed system, the blade itself was exposed for an average of 0.5 to 1.0 seconds for a distance of 4.5 to 5.0 cm. In comparison, the needle system was exposed for 0.2 seconds for a distance of 1.8 cm. CONCLUSIONS: We developed a reproducible method of measuring the forces required to place the access systems, their pattern of resistance loss, and the characteristics of the blade exposure. These parameters may provide an adjunctive and objective measurement of safety, allowing for more direct comparison between various trocar designs. (J Am Coll Surg 2009;209:222-232. (C) 2009 by the American College of Surgeons)

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: