890 resultados para GALLIUM NITRIDE NANOWIRES
Resumo:
In a ball-on-disc wear test, an alumina ceramic body sliding against a silicon nitride ceramic body in water achieved an ultra-low friction coefficient (ULFC) of 0.004. The profilometer and EDX measurements indicated that the ULFC regime in this unmated Al2O3-Si3N4 pair was achieved because of the formation of a flat and smooth interface of nanometric roughness, which favored the hydrodynamic lubrication. The triboreactions formed silicon and aluminum hydroxides which contributed to decrease roughness and shear stress at the contact interface. This behavior enables the development of low energy loss water-based tribological systems using oxide ceramics. 13 2012 Elsevier B.V. All rights reserved.
Resumo:
We consider an alternative explanation for the deficit of nu(e) in Ga solar neutrino calibration experiments and of the (nu) over bar (e) in short-baseline reactor experiments by a model where neutrinos can oscillate into sterile Kaluza-Klein modes that can propagate in compactified submicrometer flat extra dimensions. We have analyzed the results of the gallium radioactive source experiments and 19 reactor experiments with baseline shorter than 100 m, and showed that these data can be fit into this scenario. The values of the lightest neutrino mass and of the size of the largest extra dimension that are compatible with these experiments are mostly not excluded by other neutrino oscillation experiments.
Resumo:
Time-resolved photoluminescence was employed to study electron-hole dynamics in radial heterostructured GaAs/AlGaAs/GaAs core/inner shell/outer shell nanowires. It was found that impurity random potential results in a red shift of the recombination time maximum with respect to the photoluminescence peak energy.
Resumo:
The idea was to obtain nanowires in a chemical laboratory under convenient and simple conditions by employing templates. Thus it was possible to produce nanochains by interlinking of gold colloids synthesized by the two-phase-method of M. Brust with by making use of vanadiumoxide nanotubes as template. The length of the resulting nanowires is varying between 1100 nm and 200 nm with a diameter of about 16 nm. Due to a flexible linker the obtained nanowires are not completely rigid. These unique structural features could make them interesting objects for structuring and assembling in the nanoscale range. Another way to produce gold nanowires was realized by a two-step surface metallization procedure, using type I collagen fibres as a template. Gold colloids were used to label the collagen fibres by direct electrostatic interaction, followed by growth steps to enhance the size of the adsorbed colloidal gold crystals, resulting in a complete metallization of the template surface. The length of the resulting gold nanowires reaches several micrometers, with a diameter ~ 100 to 120 nm. To gain a deeper insight into the process of biomineralization the cooperative effect of self-assembled monolayers as substrate and a soluble counterpart on the nucleation and crystal growth of calcium phosphate was studied by diffusion techniques with a pH switch as initiator. As soluble component Perlucin and Nacrein were used. Both are proteins originally extracted from marine organisms, the first one from the Abalone shell and the second one from oyster pearls. Both are supposed to facilitate the calcium carbonate formation in vivo. Studies with Perlucin revealed that this protein shows a clear cooperative effect at a very low concentration with a hydrophobic surface promoting the calcium phosphate precipitation resulting in a sponge like structure of hydroxyapatite. The Perlucin molecule is very flexible and is unfolded by adsorbing to the hydrophobic surface and uncovers its active side. Hydrophilic surfaces did not have a deeper impact. Studies with Nacrein as additive have shown that the protein stabilizes octacalcium phosphate at room temperature on carboxylic self-assembled monolayer and at 34 °C on all other employed surfaces by interaction with the mineral. On the hydroxyl-, alkyl-, and amin-terminated self-assembled monolayers at room temperature the octacalcium phosphate get transformed to hydroxyapatite. Main analytical techniques which are used in this work are transmission electron microscopy, high resolution scanning electron microscopy, surface plasmon resonance spectroscopy, atomic force microscopy, Raman micro-spectroscopy and quartz crystal microbalance.
Resumo:
La ricerca, negli ultimi anni, si è concentrata sullo studio di materiali con energy gap più ampio del silicio amorfo a-Si per ridurre gli assorbimenti parassiti all'interno di celle fotovoltaiche ad eterogiunzione. In questo ambito, presso l'Università di Costanza, sono stati depositati layers di silicon oxynitride amorfo a-SiOxNy. Le promettenti aspettative di questo materiale legate all'elevato optical gap, superiore ai 2.0 eV, sono tuttavia ridimensionate dai problemi intrinseci alla struttura amorfa. Infatti la presenza di una grande quantit a di difetti limita fortemente la conducibilita e aumenta gli effetti di degradazione legati alla luce. In quest'ottica, nella presente tesi, sono stati riportati i risultati di analisi spettroscopiche eseguite presso il Dipartimento di Fisica e Astronomia di Bologna su campioni di silicon oxynitride nanocristallino nc-SiOxNy, analisi che hanno lo scopo di osservare come la struttura nanocristallina influisca sulle principali proprieta ottiche e sulla loro dipendenza da alcuni parametri di deposizione.
Resumo:
Das Silicatein α ist ein 24 kDa großes Enzym, welches im Schwamm Suberites domuncula für die Synthese von Biosilikat verantwortlich ist. Vorhergehende Studien haben gezeigt, dass Silicatein auch die Synthese anderer Metalloxide wie Titandioxid, Galliumoxid und Zirkoniumdioxid katalysieren kann. Diese Fähigkeiten machen das Silicatein α für biomedizinische und biotechnologische Anwendungen interessant, da die Synthese unter nahezu physiologischen Bedingungen ablaufen kann, was die Herstellung neuartiger Kompositmaterialien mit einzigartigen Eigenschaften erleichtern würde. Zur Immobilisierung des Silicatein α auf verschiedenen Oberflächen wurde bislang ein Nickel-NTA-Kopolymer eingesetzt. Diese Art der Immobilisierung bietet eine Reihe von Möglichkeiten in der Nanobiotechnologie, stößt aber in der Biomedizin an ihre Grenzen, da sich nicht alle Oberflächen für ein solches Coating eignen. Zudem können die zur Aktivierung des Polymers nötigen Lösungsmittel und die über die Zeit freigesetzten Monomere aus dem Polymergerüst toxische oder mutagene Wirkung auf das umliegende Gewebe haben. Deshalb wurde das Silicatein α in dieser Arbeit mit zwei Affinitäts-Tags so modifiziert, dass es an verschiedene Oberflächen immobilisiert werden kann und dabei seine Aktivität beibehält. Zuerst wurde das Silicatein mit einem Glu-tag am N-terminalen Ende modifiziert. Dadurch gelang die direkte Immobilisierung an Hydroxyapatit und die folgende, enzymkatalysierte Synthese von Biosilikat-Beschichtungen auf diesem Träger. Die Eigenschaften eines solchen HA-Kompositmaterials können zum Beispiel zu einem verbesserten, schnelleren und stabileren Einwachsen von Knochenimplantaten führen, da Biosilikat die Reifung und Differenzierung von Osteoblasten beschleunigt. rnMit dem an Hydroxyapatit-Plättchen immobilisierten Glu-tag-Silicatein wurde ein modifizierter Pull-down Assay etabliert, wodurch bekannte, aber auch bis dahin noch unbekannte Protein-Interaktionspartner identifiziert werden konnten. rnUm zu zeigen, dass der entwickelte Glu-tag an präformierte, calciumhaltige Oberflächen binden kann, wurden die Nadeln des Kalkschwammes Paraleucilla magna als Modellorganismus verwendet. Die Nadeln konnten durch das immobilisierte Silicatein mit einer Titandioxid-Schicht überzogen werden und unter Verwendung des Interaktionspartners Silintaphin-1 konnte diese Beschichtung noch verstärkt werden. Solche CaCO3-Kompositmaterialien könnten sowohl in der Biomedizin als auch in der Biotechnologie zum Einsatz kommen. Neben den erwähnten calciumhaltigen Materialien finden auch andere Stoffe wie TiO2-Nanodrähte Verwendung in der Forschung. In weiterführenden Experimenten konnte gezeigt werden, dass der entwickelte Glu-tag auch Affinität zu Titandioxid-Oberflächen vermittelt. Auch hier konnte durch das oberflächenimmobilisierte Enzym eine Biosilikatbeschichtung synthetisiert werden. rnMit der zweiten Modifikation - einem Cys-tag - konnte Silicatein direkt auf Goldoberflächen immobilisiert werden. Durch die Verwendung eines Polydimethylsiloxan (PDMS)-Stempels wurde das Cys-getaggte Silicatein in einem linienförmigen Muster auf das Gold übertragen und die Synthese von Titandioxid dort nachgewiesen.rnDie Experimente und Ergebnisse dieser Arbeit haben gezeigt, dass Silicatein α durch einfache Modifikationen an verschiedene Oberflächen immobilisiert werden kann und dabei immer noch seine Aktivität behält. rnHierdurch ergibt sich die Möglichkeit, unter Normalbedingungen verschiedenste Kompositmaterialien herzustellen.rn
Resumo:
We performed a pooled analysis of three trials comparing titanium-nitride-oxide-coated bioactive stents (BAS) with paclitaxel-eluting stents (PES) in 1,774 patients. All patients were followed for 12 months. The primary outcomes of interest were recurrent myocardial infarction (MI), death and target lesion revascularization (TLR). Secondary endpoints were stent thrombosis (ST) and major adverse cardiac events (MACE) including MI, death and TLR. There were 922 patients in the BAS group and 852 in the PES group. BAS significantly reduced the risk of recurrent MI (2.7% vs. 5.6%; risk ratio 0.50, 95% CI 0.31-0.81; p = 0.004) and MACE (8.9% vs. 12.6%; risk ratio 0.71, 95% CI 0.54-0.94; p = 0.02) during the 12 months of follow up. In contrast, the differences between BAS and PES were not statistically significant with respect to TLR (risk ratio 0.98, 95% CI 0.68-1.41), death (risk ratio 0.96, 95% CI 0.61-1.51) and definite ST (risk ratio 0.28, 95% CI 0.05-1.47). In conclusion, the results of this analysis suggest that BAS is effective in reducing TLR and improves clinical outcomes by reducing MI and MACE compared with PES.
Resumo:
Revascularisation with Titanium-Nitride-Oxide (TiNOX) coated stents is safe and effective in patients with de novo native coronary artery lesions. In the TiNOX trial there was a reduction in restenosis and major adverse cardiac events as compared with stainless steel stents of otherwise identical design. The purpose of the present study was to evaluate the long-term outcome of these patients over five years.
Resumo:
Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)
Resumo:
We performed a propensity score matched analysis to explore whether TiNOX stents are superior to paclitaxel- (PES) and sirolimus-eluting stents (SES) in routine clinical practice.
Resumo:
The use of metal chelators is becoming increasingly important in the development of new tracers for molecular imaging. With the rise of the field of nanotechnology, the fusion of both technologies has shown great potential for clinical applications. The pharmacokinetcs of nanoparticles can be monitored via positron emission tomography (PET) after surface modification and radiolabeling with positron emitting radionuclides. Different metal ion chelators can be used to facilitate labeling of the radionuclides and as a prerequisite, optimized radiolabeling procedure is necessary to prevent nanoparticle aggregation and degradation. However, the effects of chelator modification on nanoparticle pharmacokinetic properties have not been well studied and currently no studies to date have compared the biological effects of the use of different chelators in the surface modification of nanoparticles.
Resumo:
Interest in the study of magnetic/non-magnetic multilayered structures took a giant leap since Grünberg and his group established that the interlayer exchange coupling (IEC) is a function of the non-magnetic spacer width. This interest was further fuelled by the discovery of the phenomenal Giant Magnetoresistance (GMR) effect. In fact, in 2007 Albert Fert and Peter Grünberg were awarded the Nobel Prize in Physics for their contribution to the discovery of GMR. GMR is the key property that is being used in the read-head of the present day computer hard drive as it requires a high sensitivity in the detection of magnetic field. The recent increase in demand for device miniaturization encouraged researchers to look for GMR in nanoscale multilayered structures. In this context, one dimensional(1-D) multilayerd nanowire structure has shown tremendous promise as a viable candidate for ultra sensitive read head sensors. In fact, the phenomenal giant magnetoresistance(GMR) effect, which is the novel feature of the currently used multilayered thin film, has already been observed in multilayered nanowire systems at ambient temperature. Geometrical confinement of the supper lattice along the 2-dimensions (2-D) to construct the 1-D multilayered nanowire prohibits the minimization of magnetic interaction- offering a rich variety of magnetic properties in nanowire that can be exploited for novel functionality. In addition, introduction of non-magnetic spacer between the magnetic layers presents additional advantage in controlling magnetic properties via tuning the interlayer magnetic interaction. Despite of a large volume of theoretical works devoted towards the understanding of GMR and IEC in super lattice structures, limited theoretical calculations are reported in 1-D multilayered systems. Thus to gauge their potential application in new generation magneto-electronic devices, in this thesis, I have discussed the usage of first principles density functional theory (DFT) in predicting the equilibrium structure, stability as well as electronic and magnetic properties of one dimensional multilayered nanowires. Particularly, I have focused on the electronic and magnetic properties of Fe/Pt multilayered nanowire structures and the role of non-magnetic Pt spacer in modulating the magnetic properties of the wire. It is found that the average magnetic moment per atom in the nanowire increases monotonically with an ~1/(N(Fe)) dependance, where N(Fe) is the number of iron layers in the nanowire. A simple model based upon the interfacial structure is given to explain the 1/(N(Fe)) trend in magnetic moment obtained from the first principle calculations. A new mechanism, based upon spin flip with in the layer and multistep electron transfer between the layers, is proposed to elucidate the enhancement of magnetic moment of Iron atom at the Platinum interface. The calculated IEC in the Fe/Pt multilayered nanowire is found to switch sign as the width of the non-magnetic spacer varies. The competition among short and long range direct exchange and the super exchange has been found to play a key role for the non-monotonous sign in IEC depending upon the width of the Platinum spacer layer. The calculated magnetoresistance from Julliere's model also exhibit similar switching behavior as that of IEC. The universality of the behavior of exchange coupling has also been looked into by introducing different non-magnetic spacers like Palladium, Copper, Silver, and Gold in between magnetic Iron layers. The nature of hybridization between Fe and other non-magnetic spacer is found to dictate the inter layer magnetic interaction. For example, in Fe/Pd nanowire the d-p hybridization in two spacer layer case favors anti-ferromagnetic (AFM) configuration over ferromagnetic (FM) configuration. However, the hybridization between half-filled Fe(d) and filled Cu(p) state in Fe/Cu nanowire favors FM coupling in the 2-spacer system.
Resumo:
Thermal analysis VIPS used to construct cooling and heating curves from which the phase diagram was determined. The data for the entire set of cooling curves were obtained by the use of mercury thermometers.
Resumo:
Aims: Stents with a passive coating of titanium-nitride-oxide (TiNO) have been compared with Endeavor® zotarolimus-eluting stents (E-ZES) with regard to the primary endpoint of in-stent late lumen loss at six to eight months. The objective of the present analysis was to compare the long-term outcomes of TiNO stents with E-ZES up to five years of clinical follow-up. Methods and results: A total of 302 patients had been randomly allocated to treatment with TiNO or E-ZES. Up to five years of follow-up, major adverse cardiac events (MACE), the composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularisation (TLR), were observed in 27.6% of patients treated with TiNO stents and 25.3% of patients treated with E-ZES (RR 1.13, 95% CI: 0.72-1.75, p=0.60), with the majority of events related to clinically indicated TVR (TiNO 21.7% versus E-ZES 20.7%, RR 1.10, 95% CI: 0.67-1.81). There were no differences with respect to individual events including cardiac death, myocardial infarction or stent thrombosis between the two treatment arms up to five years of follow-up. A majority of patients remained free from angina throughout the entire study duration (TiNO 77.3% versus E-ZES 76.1%, p=0.92). Conclusions: Final five-year outcomes of the TIDE trial comparing TiNO stents with E-ZES revealed increased rates of MACE driven primarily by clinically indicated TVR. The TIDE trial is registered at ClinicalTrials.gov: NCT00492908.