Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation.


Autoria(s): Pilgrim, Thomas; Räber, Lorenz; Limacher, Andreas; Wenaweser, Peter Martin; Cook, Stéphane; Stauffer, Jean-Christophe; Garachemani, Ali Reza; Moschovitis, Aris; Meier, Bernhard; Jüni, Peter; Windecker, Stephan
Data(s)

12/01/2015

Resumo

Aims: Stents with a passive coating of titanium-nitride-oxide (TiNO) have been compared with Endeavor® zotarolimus-eluting stents (E-ZES) with regard to the primary endpoint of in-stent late lumen loss at six to eight months. The objective of the present analysis was to compare the long-term outcomes of TiNO stents with E-ZES up to five years of clinical follow-up. Methods and results: A total of 302 patients had been randomly allocated to treatment with TiNO or E-ZES. Up to five years of follow-up, major adverse cardiac events (MACE), the composite of cardiac death, myocardial infarction, or clinically indicated target vessel revascularisation (TLR), were observed in 27.6% of patients treated with TiNO stents and 25.3% of patients treated with E-ZES (RR 1.13, 95% CI: 0.72-1.75, p=0.60), with the majority of events related to clinically indicated TVR (TiNO 21.7% versus E-ZES 20.7%, RR 1.10, 95% CI: 0.67-1.81). There were no differences with respect to individual events including cardiac death, myocardial infarction or stent thrombosis between the two treatment arms up to five years of follow-up. A majority of patients remained free from angina throughout the entire study duration (TiNO 77.3% versus E-ZES 76.1%, p=0.92). Conclusions: Final five-year outcomes of the TIDE trial comparing TiNO stents with E-ZES revealed increased rates of MACE driven primarily by clinically indicated TVR. The TIDE trial is registered at ClinicalTrials.gov: NCT00492908.

Formato

application/pdf

Identificador

http://boris.unibe.ch/62262/7/Pilgrim%20EuroIntervention%202015.pdf

Pilgrim, Thomas; Räber, Lorenz; Limacher, Andreas; Wenaweser, Peter Martin; Cook, Stéphane; Stauffer, Jean-Christophe; Garachemani, Ali Reza; Moschovitis, Aris; Meier, Bernhard; Jüni, Peter; Windecker, Stephan (2015). Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention, 10(11), pp. 1284-7. Europa Digital & Publishing 10.4244/EIJY15M01_04 <http://dx.doi.org/10.4244/EIJY15M01_04>

doi:10.7892/boris.62262

info:doi:10.4244/EIJY15M01_04

info:pmid:25572026

urn:issn:1774-024X

Idioma(s)

eng

Publicador

Europa Digital & Publishing

Relação

http://boris.unibe.ch/62262/

Direitos

info:eu-repo/semantics/openAccess

Fonte

Pilgrim, Thomas; Räber, Lorenz; Limacher, Andreas; Wenaweser, Peter Martin; Cook, Stéphane; Stauffer, Jean-Christophe; Garachemani, Ali Reza; Moschovitis, Aris; Meier, Bernhard; Jüni, Peter; Windecker, Stephan (2015). Five-year results of a randomised comparison of titanium-nitride-oxide-coated stents with zotarolimus-eluting stents for coronary revascularisation. EuroIntervention, 10(11), pp. 1284-7. Europa Digital & Publishing 10.4244/EIJY15M01_04 <http://dx.doi.org/10.4244/EIJY15M01_04>

Palavras-Chave #610 Medicine & health #360 Social problems & social services
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed