993 resultados para inmunofluorescent antibody test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Specific anti-polysaccharide antibody deficiency (SPAD) is an immune disorder. Diagnostic criteria have not yet been defined clearly. One hundred and seventy-six children evaluated for recurrent respiratory tract infections were analysed retrospectively. For each subject, specific anti-pneumococcal antibodies had been measured with two enzyme-linked immunosorbent assays (ELISAs), one overall assay (OA) using the 23-valent pneumococcal polysaccharide vaccine (23-PPSV) as detecting antigen and the other purified pneumococcal polysaccharide serotypes (serotype-specific assay, SSA) (serotypes 14, 19F and 23F). Antibody levels were measured before (n = 176) and after (n = 93) immunization with the 23-PPSV. Before immunization, low titres were found for 138 of 176 patients (78%) with OA, compared to 20 of 176 patients (11%) with the SSA. We found a significant correlation between OA and SSA results. After immunization, 88% (71 of 81) of the patients considered as responders in the OA test were also responders in the SSA; 93% (71 of 76) of the patients classified as responders according to the SSA were also responders in the OA. SPAD was diagnosed in 8% (seven of 93) of patients on the basis of the absence of response in both tests. Thus, we propose to use OA as a screening test for SPAD before 23-PPSV immunization. After immunization, SSA should be used only in case of a low response in OA. Only the absence of or a very low antibody response detected by both tests should be used as a diagnostic criterion for SPAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Serologic methods have been used widely to test for celiac disease and have gained importance in diagnostic definition and in new epidemiologic findings. However, there is no standardization, and there are no reference protocols and materials. METHODS: The European working group on Serological Screening for Celiac Disease has defined robust noncommercial test protocols for immunoglobulin (Ig)G and IgA gliadin antibodies and for IgA autoantibodies against endomysium and tissue transglutaminase. Standard curves were linear in the decisive range, and intra-assay variation coefficients were less than 5% to 10%. Calibration was performed with a group reference serum. Joint cutoff limits were used. Seven laboratories took part in the final collaborative study on 252 randomized sera classified by histology (103 pediatric and adult patients with active celiac disease, 89 disease control subjects, and 60 blood donors). RESULTS: IgA autoantibodies against endomysium and tissue transglutaminase rendered superior sensitivity (90% and 93%, respectively) and specificity (99% and 95%, respectively) over IgA and IgG gliadin antibodies. Tissue transglutaminase antibody testing showed superior receiver operating characteristic performance compared with gliadin antibodies. The K values for interlaboratory reproducibility showed superiority for IgA endomysium (0.93) in comparison with tissue transglutaminase antibodies (0.83) and gliadin antibodies (0.82 for IgG, 0.62 for IgA). CONCLUSIONS: Basic criteria of standardization and quality assessment must be fulfilled by any given test protocol proposed for serologic investigation of celiac disease. The working group has produced robust test protocols and reference materials available for standardization to further improve reliability of serologic testing for celiac disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the value of serum antitissue transglutaminase IgA antibodies (IgA-TTG) and IgA antiendomysial antibodies (IgA-EMA) in the diagnosis of coeliac disease in cohorts from different geographical areas in Europe. The setting allowed a further comparison between the antibody results and the conventional small-intestinal histology. METHODS: A total of 144 cases with coeliac disease [median age 19.5 years (range 0.9-81.4)], and 127 disease controls [median age 29.2 years (range 0.5-79.0)], were recruited, on the basis of biopsy, from 13 centres in nine countries. All biopsy specimens were re-evaluated and classified blindly a second time by two investigators. IgA-TTG were determined by ELISA with human recombinant antigen and IgA-EMA by an immunofluorescence test with human umbilical cord as antigen. RESULTS: The quality of the biopsy specimens was not acceptable in 29 (10.7%) of 271 cases and a reliable judgement could not be made, mainly due to poor orientation of the samples. The primary clinical diagnosis and the second classification of the biopsy specimens were divergent in nine cases, and one patient was initially enrolled in the wrong group. Thus, 126 coeliac patients and 106 controls, verified by biopsy, remained for final analysis. The sensitivity of IgA-TTG was 94% and IgA-EMA 89%, the specificity was 99% and 98%, respectively. CONCLUSIONS: Serum IgA-TTG measurement is effective and at least as good as IgA-EMA in the identification of coeliac disease. Due to a high percentage of poor histological specimens, the diagnosis of coeliac disease should not depend only on biopsy, but in addition the clinical picture and serology should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Persistent polyclonal B cell lymphocytosis (PPBL) is a rare condition characterized by increased IgM and large excess of B cells with an IgD(+) CD27(+) phenotype. In normal individuals, these cells play a central role in the defense against pneumococcal infection. So far, few studies have characterized humoral immune responses in PPBL patients. We therefore measured IgG directed against S. pneumoniae antigens in a 51 yr-old woman with PPBL before and after vaccination with a pneumococcal 23-valent polysaccharide vaccine. METHODS: Antibodies against pneumococcal antigens were measured first with an overall immunoassay using microplates coated with the 23-valent pneumococcal vaccine. A serotype-specific test was also performed according to the WHO consensus protocol. RESULTS: Despite a large number of IgD(+) CD27(+) cells, our patient had low baseline titers of IgG directed against pneumococcal antigens and did not significantly respond to a 23-valent polysaccharide vaccine against S. pneumoniae. On the contrary, she had good titers of IgG directed against tetanus toxoid. CONCLUSION: IgM(+) IgD(+) CD27(+) cells which accumulate in this patient with typical PPBL patient failed to perform IgG isotype switch after a polysaccharide vaccine. The potential mechanisms and relationships with the main features of PPBL are discussed. Further studies on a larger number of similar patients are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti-neutrophil cytoplasmic antibodies (ANCA) are diagnostic markers for systemic vasculitis. They are classically I detected by an indirect immunofluorescence test using normal donor neutrophils as substrate. This assay lacks antigenic specificity and is not quantitative. The 'EC/BCR Project for ANCA Assay Standardization' is an international collaboration study with the aim to develop and standardize solid phase assays for ANCA detection. In this part of the study the isolation and characterization of proteinase-3 and myeloperoxidase, the two main target molecules for ANCA, and the development and standardization of ELISAs with these antigens are described. Six laboratories successfully isolated purified proteinase-3 preparations that could be used. Three of these preparations, together with one myeloperoxidase preparation, were subsequently used for ANCA testing by ELISA. The ELISA technique was standardized in two rounds of testing in the 14 participating laboratories. The coefficient of variation of these new assays decreased from values of approx. 50% in the first round to approx. 20% in the second round. We conclude that purified proteinase-3 and myeloperoxidase can be used in standardized ELISAs for ANCA detection. Whether such procedures offer advantages over the IIF test will be determined in a prospective clinical study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congrès du GIRSO, Lille, avril 2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the immunogenicity and safety of a 23-valent pneumococcal vaccine in human immunodeficiency virus (HIV)-seropositive patients, 80 men and 18 women received 1 dose of the vaccine (Pneumo 23; Pasteur Mérieux MSD, Brussels). The total IgG antibody response against all 23 Streptococcus pneumoniae capsular antigens was measured. Antibody levels were expressed in arbitrary units per microliter, referring to a standard curve. Geometric mean titers of the total IgG capsular antibodies on the day of vaccination and 30-45 days later were compared. The ratios of titers after and before vaccination in patients with > 500, 200-500, and < 200 CD4 lymphocytes/microL were 10, 10, and 12.6, respectively. Nonresponse (ratio < 4) occurred in 17% of patients and was unrelated to CD4 cell count. The vaccine was well tolerated; no serious side effects occurred. In 83% of the patients with HIV infection, the total antipneumococcal IgG level was higher after vaccination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Editorial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Timing-related defects are major contributors to test escapes and in-field reliability problems for very-deep submicrometer integrated circuits. Small delay variations induced by crosstalk, process variations, power-supply noise, as well as resistive opens and shorts can potentially cause timing failures in a design, thereby leading to quality and reliability concerns. We present a test-grading technique that uses the method of output deviations for screening small-delay defects (SDDs). A new gate-delay defect probability measure is defined to model delay variations for nanometer technologies. The proposed technique intelligently selects the best set of patterns for SDD detection from an n-detect pattern set generated using timing-unaware automatic test-pattern generation (ATPG). It offers significantly lower computational complexity and excites a larger number of long paths compared to a current generation commercial timing-aware ATPG tool. Our results also show that, for the same pattern count, the selected patterns provide more effective coverage ramp-up than timing-aware ATPG and a recent pattern-selection method for random SDDs potentially caused by resistive shorts, resistive opens, and process variations. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously shown that treatment of prostate cancer and melanoma cells expressing GRP78 on their cell surface with antibody directed against the COOH-terminal domain of GRP78 upregulates and activates p53 causing decreased cell proliferation and upregulated apoptosis. In this report, we demonstrate that treatment of 1-LN prostate cancer cells with this antibody decreases cell surface expression of GRP78, Akt(Thr308) and Akt(Ser473) kinase activities and reduces phosphorylation of FOXO, and GSK3beta. This treatment also suppresses activation of ERK1/2, p38 MAPK and MKK3/6; however, it upregulates MKK4 activity. JNK, as determined by its phosphorylation state, is subsequently activated, triggering apoptosis. Incubation of cells with antibody reduced levels of anti-apoptotic Bcl-2, while elevating pro-apoptotic BAD, BAX and BAK expression as well as cleaved caspases-3, -7, -8 and -9. Silencing GRP78 or p53 gene expression by RNAi prior to antibody treatment abrogated these effects. We conclude that antibody directed against the COOH-terminal domain of GRP78 may prove useful as a pan suppressor of proliferative/survival signaling in cancer cells expressing GRP78 on their cell surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several human monoclonal antibodies (hmAbs) exhibit relatively potent and broad neutralizing activity against HIV-1, but there has not been much success in using them as potential therapeutics. We have previously hypothesized and demonstrated that small engineered antibodies can target highly conserved epitopes that are not accessible by full-size antibodies. However, their potency has not been comparatively evaluated with known HIV-1-neutralizing hmAbs against large panels of primary isolates. We report here the inhibitory activity of an engineered single chain antibody fragment (scFv), m9, against several panels of primary HIV-1 isolates from group M (clades A-G) using cell-free and cell-associated virus in cell line-based assays. M9 was much more potent than scFv 17b, and more potent than or comparable to the best-characterized broadly neutralizing hmAbs IgG(1) b12, 2G12, 2F5 and 4E10. It also inhibited cell-to-cell transmission of HIV-1 with higher potency than enfuvirtide (T-20, Fuzeon). M9 competed with a sulfated CCR5 N-terminal peptide for binding to gp120-CD4 complex, suggesting an overlapping epitope with the coreceptor binding site. M9 did not react with phosphatidylserine (PS) and cardiolipin (CL), nor did it react with a panel of autoantigens in an antinuclear autoantibody (ANA) assay. We further found that escape mutants resistant to m9 did not emerge in an immune selection assay. These results suggest that m9 is a novel anti-HIV-1 candidate with potential therapeutic or prophylactic properties, and its epitope is a new target for drug or vaccine development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: A candidate vaccine consisting of human immunodeficiency virus type 1 (HIV-1) subunit gp120 protein was found previously to be nonprotective in an efficacy trial (Vax004) despite strong antibody responses against the vaccine antigens. Here we assessed the magnitude and breadth of neutralizing antibody responses in Vax004. METHODS: Neutralizing antibodies were measured against highly sensitive (tier 1) and moderately sensitive (tier 2) strains of HIV-1 subtype B in 2 independent assays. Vaccine recipients were stratified by sex, race, and high versus low behavioral risk of HIV-1 acquisition. RESULTS: Most vaccine recipients mounted potent neutralizing antibody responses against HIV-1(MN) and other tier 1 viruses. Occasional weak neutralizing activity was detected against tier 2 viruses. The response against tier 1 and tier 2 viruses was significantly stronger in women than in men. Race and behavioral risk of HIV-1 acquisition had no significant effect on the response. Prior vaccination had little effect on the neutralizing antibody response that arose after infection. CONCLUSIONS: Weak overall neutralizing antibody responses against tier 2 viruses is consistent with a lack of protection in this trial. The magnitude and breadth of neutralization reported here should be useful for identifying improved vaccines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CD20 was the first B cell differentiation antigen identified, and CD20-specific mAbs are commonly used for the treatment of B cell malignancies and autoantibody-mediated autoimmune diseases. Despite this the role of CD20 in human B cell physiology has remained elusive. We describe here a juvenile patient with CD20 deficiency due to a homozygous mutation in a splice junction of the CD20 gene (also known as MS4A1) that results in "cryptic" splicing and nonfunctional mRNA species. Analysis of this patient has led us to conclude that CD20 has a central role in the generation of T cell-independent (TI) antibody responses. Key evidence to support this conclusion was provided by the observation that although antigen-independent B cells developed normally in the absence of CD20 expression, antibody formation, particularly after vaccination with TI antigens, was strongly impaired in the patient. Consistent with this, TI antipolysaccharide B cell responses were severely impeded in CD20-deficient mice. Our study therefore identifies what we believe to be a novel type of humoral immunodeficiency caused by CD20 deficiency and characterized by normal development of antigen-independent B cells, along with a reduced capacity to mount proper antibody responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a time-course microarray experiment, the expression level for each gene is observed across a number of time-points in order to characterize the temporal trajectories of the gene-expression profiles. For many of these experiments, the scientific aim is the identification of genes for which the trajectories depend on an experimental or phenotypic factor. There is an extensive recent body of literature on statistical methodology for addressing this analytical problem. Most of the existing methods are based on estimating the time-course trajectories using parametric or non-parametric mean regression methods. The sensitivity of these regression methods to outliers, an issue that is well documented in the statistical literature, should be of concern when analyzing microarray data. RESULTS: In this paper, we propose a robust testing method for identifying genes whose expression time profiles depend on a factor. Furthermore, we propose a multiple testing procedure to adjust for multiplicity. CONCLUSIONS: Through an extensive simulation study, we will illustrate the performance of our method. Finally, we will report the results from applying our method to a case study and discussing potential extensions.