896 resultados para High impedance ground plane(HIGP)
Resumo:
The impedance-based stability-assessment method has turned out to be a very effective tool and its usage is rapidly growing in different applications ranging from the conventional interconnected dc/dc systems to the grid-connected renewable energy systems. The results are sometime given as a certain forbidden region in the complex plane out of which the impedance ratio--known as minor-loop gain--shall stay for ensuring robust stability. This letter discusses the circle-like forbidden region occupying minimum area in the complex plane, defined by applying maximum peak criteria, which is well-known theory in control engineering. The investigation shows that the circle-like forbidden region will ensure robust stability only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem within the interconnected system. Experimental evidence is provided based on a small-scale dc/dc distributed system.
Resumo:
This work is related to the output impedance improvement of a Multiphase Buck converter with Peak Current Mode Control (PCMC) by means of introducing an additional power path that virtually increases the output capacitance during transients. Various solutions that can be employed to improve the dynamic behavior of the converter system exist, but nearly all solutions are developed for a Single Phase Buck converter with Voltage Mode Control (VMC), while in the VRM applications, due to the high currents, the system is usually implemented as a Multiphase Buck Converter with Current Mode Control. The Output Impedance Correction Circuit (OICC) is used to inject or extract a current n-1 times larger than the output capacitor current, thus virtually increasing n times the value of the output capacitance during the transients. Furthermore, this work extends the OICC concept to a Multiphase Buck Converter system while comparing proposed solution with the system that has n times bigger output capacitor. In addition, the OICC is implemented as a Synchronous Buck Converter with PCMC, thus reducing its influence on the system efficiency
Resumo:
In this study, the evaluation of the accuracy and performance of a light detection and ranging (LIDAR) sensor for vegetation using distance and reflection measurements aiming to detect and discriminate maize plants and weeds from soil surface was done. The study continues a previous work carried out in a maize field in Spain with a LIDAR sensor using exclusively one index, the height profile. The current system uses a combination of the two mentioned indexes. The experiment was carried out in a maize field at growth stage 12–14, at 16 different locations selected to represent the widest possible density of three weeds: Echinochloa crus-galli (L.) P.Beauv., Lamium purpureum L., Galium aparine L.and Veronica persica Poir.. A terrestrial LIDAR sensor was mounted on a tripod pointing to the inter-row area, with its horizontal axis and the field of view pointing vertically downwards to the ground, scanning a vertical plane with the potential presence of vegetation. Immediately after the LIDAR data acquisition (distances and reflection measurements), actual heights of plants were estimated using an appropriate methodology. For that purpose, digital images were taken of each sampled area. Data showed a high correlation between LIDAR measured height and actual plant heights (R 2 = 0.75). Binary logistic regression between weed presence/absence and the sensor readings (LIDAR height and reflection values) was used to validate the accuracy of the sensor. This permitted the discrimination of vegetation from the ground with an accuracy of up to 95%. In addition, a Canonical Discrimination Analysis (CDA) was able to discriminate mostly between soil and vegetation and, to a far lesser extent, between crop and weeds. The studied methodology arises as a good system for weed detection, which in combination with other principles, such as vision-based technologies, could improve the efficiency and accuracy of herbicide spraying.
Resumo:
Dynamic weighing systems based on load cells are commonly used to estimate crop yields in the field. There is lack of data, however, regarding the accuracy of such weighing systems mounted on harvesting machinery, especially on that used to collect high value crops such as fruits and vegetables. Certainly, dynamic weighing systems mounted on the bins of grape harvesters are affected by the displacement of the load inside the bin when moving over terrain of changing topography. In this work, the load that would be registered in a grape harvester bin by a dynamic weighing system based on the use of a load cell was inferred by using the discrete element method (DEM). DEM is a numerical technique capable of accurately describing the behaviour of granular materials under dynamic situations and it has been proven to provide successful predictions in many different scenarios. In this work, different DEM models of a grape harvester bin were developed contemplating different influencing factors. Results obtained from these models were used to infer the output given by the load cell of a real bin. The mass detected by the load cell when the bin was inclined depended strongly on the distribution of the load within the bin, but was underestimated in all scenarios. The distribution of the load was found to be dependent on the inclination of the bin caused by the topography of the terrain, but also by the history of inclination (inclination rate, presence of static periods, etc.) since the effect of the inertia of the particles (i.e., representing the grapes) was not negligible. Some recommendations are given to try to improve the accuracy of crop load measurement in the field.
Resumo:
An impedance-based midspan debonding identification method for RC beams strengthened with FRP strips is presented in this paper using piezoelectric ceramic (PZT) sensor?actuators. To reach this purpose, firstly, a two-dimensional electromechanical impedance model is proposed to predict the electrical admittance of the PZT transducer bonded to the FRP strips of an RC beam. Considering the impedance is measured in high frequencies, a spectral element model of the bonded-PZT?FRP strengthened beam is developed. This model, in conjunction with experimental measurements of PZT transducers, is used to present an updating methodology to quantitatively detect interfacial debonding of these kinds of structures. To improve the performance and accuracy of the detection algorithm in a challenging problem such as ours, the structural health monitoring approach is solved with an ensemble process based on particle of swarm. An adaptive mesh scheme has also been developed to increase the reliability in locating the area in which debonding initiates. Predictions carried out with experimental results have showed the effectiveness and potential of the proposed method to detect prematurely at its earliest stages a critical failure mode such as that due to midspan debonding of the FRP strip.
New On-Line Excitation-System Ground Fault Location Method Tested in a 106 MVA Synchronous Generator
Resumo:
In this paper, a novel excitation-system ground-fault location method is described and tested in a 106 MVA synchronous machine. In this unit, numerous rotor ground-fault trips took place always about an hour after the synchronization to the network. However, when the field winding insulation was checked after the trips, there was no failure. The data indicated that the faults in the rotor were caused by centrifugal forces and temperature. Unexpectedly, by applying this new method, the failure was located in a cable between the excitation transformer and the automatic voltage regulator. In addition, several intentional ground faults were performed along the field winding with different fault resistance values, in order to test the accuracy of this method to locate defects in rotor windings of large generators. Therefore, this new on-line rotor ground-fault detection algorithm is tested in high-power synchronous generators with satisfactory results.
Resumo:
A numerical simulation of the aerodynamic behavior of high-speed trains under synthetic crosswinds at a 90º yaw angle is presented. The train geometry is the aerodynamic train model (ATM). Flow description based on numerical simulations is obtained using large eddy simulation (LES) and the commercial code ANSYSFluent V14.5. A crosswind whose averaged velocity and turbulence characteristics change with distance to the ground is imposed. Turbulent fluctuations that vary temporally and spatially are simulated with TurbSim code. The crosswind boundary condition is calculated for the distance the train runs during a simulation period. The inlet streamwise velocity boundary condition is generated using Taylor?s frozen turbulence hypothesis. The model gives a time history of the force and moments acting on the train; this includes averaged values, standard deviations and extreme values. Of particular interest are the spectra of the forces and moments, and the admittance spectra. For comparison, results obtained with LES and a uniform wind velocity fluctuating in time, and results obtained with Reynolds averaged Navier Stokes equations (RANS), and the averaged wind conditions, are also presented.
A simplified spectral approachfor impedance-based damage identification of frp-strengthened rc beams
Resumo:
Hoy en día, el refuerzo y reparación de estructuras de hormigón armado mediante el pegado de bandas de polímeros reforzados con fibras (FRP) se emplea cada vez con más frecuencia a causa de sus numerosas ventajas. Sin embargo, las vigas reforzadas con esta técnica pueden experimentar un modo de fallo frágil a causa del despegue repentino de la banda de FRP a partir de una fisura intermedia. A pesar de su importancia, el número de trabajos que abordan el estudio de este mecanismo de fallo y su monitorización es muy limitado. Por ello, el desarrollo de metodologías capaces de monitorizar a largo plazo la adherencia de este refuerzo a las estructuras de hormigón e identificar cuándo se inicia el despegue de la banda constituyen un importante desafío a abordar. El principal objetivo de esta tesis es la implementación de una metodología fiable y efectiva, capaz de detectar el despegue de una banda de FRP en una viga de hormigón armado a partir de una fisura intermedia. Para alcanzar este objetivo se ha implementado un procedimiento de calibración numérica a partir de ensayos experimentales. Para ello, en primer lugar, se ha desarrollado un modelo numérico unidimensional simple y no costoso representativo del comportamiento de este tipo vigas de hormigón reforzadas con FRP, basado en un modelo de fisura discreta para el hormigón y el método de elementos espectrales. La formación progresiva de fisuras a flexion y el consiguiente despegue en la interface entre el hormigón y el FRP se formulan mediante la introducción de un nuevo elemento capaz de representar ambos fenómenos simultáneamente sin afectar al procedimiento numérico. Además, con el modelo propuesto, se puede obtener de una forma sencilla la respuesta dinámica en altas frecuencias de este tipo de estructuras, lo cual puede hacer muy útil su uso como herramienta de diagnosis y detección del despegue en su fase inicial mediante una monitorización de la variación de las características dinámicas locales de la estructura. Un método de evaluación no destructivo muy prometedor para la monitorización local de las estructuras es el método de la impedancia usando sensores-actuadores piezoeléctricos (PZT). La impedancia eléctrica de los sensores PZT se puede relacionar con la impedancia mecánica de las estructuras donde se encuentran adheridos Ya que la impedancia mecánica de una estructura se verá afectada por su deterioro, se pueden implementar indicadores de daño mediante una comparación del espectro de admitancia (inversa de la impedancia) a lo largo de distintas etapas durante el periodo de servicio de una estructura. Cualquier cambio en el espectro se podría interpretar como una variación en la integridad de la estructura. La impedancia eléctrica se mide a altas frecuencias con lo cual esta metodología debería ser muy sensible a la detección de estados de daño incipiente local, tal como se desea en la aplicación de este trabajo. Se ha implementado un elemento espectral PZT-FRP como extensión del modelo previamente desarrollado, con el objetivo de poder calcular numéricamente la impedancia eléctrica de sensores PZT adheridos a bandas de FRP sobre una viga de hormigón armado. El modelo, combinado con medidas experimentales captadas mediante sensores PZT, se implementa en el marco de una metodología de calibración de modelos para detectar cuantitativamente el despegue en la interfase entre una banda de FRP y una viga de hormigón. El procedimiento de optimización se resuelve empleando el método del enjambre cooperativo con un algoritmo bagging. Los resultados muestran una gran aproximación en la estimación del daño para el problema propuesto. Adicionalmente, se ha desarrollado también un método adaptativo para el mallado de elementos espectrales con el objetivo de localizar las zonas dañadas a partir de los resultados experimentales, el cual contribuye a aumentar la robustez y efectividad del método propuesto a la hora de identificar daños incipientes en su aparición inicial. Finalmente, se ha llevado a cabo un procedimiento de optimización multi-objetivo para detectar el despegue inicial en una viga de hormigón a escala real reforzada con FRP a partir de las impedancias captadas con una red de sensores PZT instrumentada a lo largo de la longitud de la viga. Cada sensor aporta los datos para definir cada una de las funciones objetivo que definen el procedimiento. Combinando el modelo previo de elementos espectrales con un algoritmo PSO multi-objetivo el procedimiento de detección de daño resultante proporciona resultados satisfactorios considerando la escala de la estructura y todas las incertidumbres características ligadas a este proceso. Los resultados obtenidos prueban la viabilidad y capacidad de los métodos antes mencionados y también su potencial en aplicaciones reales. Abstract Nowadays, the external bonding of fibre reinforced polymer (FRP) plates or sheets is increasingly used for the strengthening and retrofitting of reinforced concrete (RC) structures due to its numerous advantages. However, this kind of strengthening often leads to brittle failure modes being the most dominant failure mode the debonding induced by an intermediate crack (IC). In spite of its importance, the number of studies regarding the IC debonding mechanism and bond health monitoring is very limited. Methodologies able to monitor the long-term efficiency of bonding and successfully identify the initiation of FRP debonding constitute a challenge to be met. The main purpose of this thesisis the implementation of a reliable and effective methodology of damage identification able to detect intermediate crack debonding in FRP-strengthened RC beams. To achieve this goal, a model updating procedure based on numerical simulations and experimental tests has been implemented. For it, firstly, a simple and non-expensive one-dimensional model based on the discrete crack approach for concrete and the spectral element method has been developed. The progressive formation of flexural cracks and subsequent concrete-FRP interfacial debonding is formulated by the introduction of a new element able to represent both phenomena simultaneously without perturbing the numerical procedure. Furthermore, with the proposed model, high frequency dynamic response for these kinds of structures can also be obtained in a very simple and non-expensive way, which makes this procedure very useful as a tool for diagnoses and detection of debonding in its initial stage by monitoring the change in local dynamic characteristics. One very promising active non-destructive evaluation method for local monitoring is impedance-based structural health monitoring(SHM)using piezoelectric ceramic (PZT) sensor-actuators. The electrical impedance of the PZT can be directly related to the mechanical impedance of the host structural component where the PZT transducers are attached. Since the structural mechanical impedance will be affected by the presence of structural damage, comparisons of admittance (inverse of impedance) spectra at various times during the service period of the structure can be used as damage indicator. Any change in the spectra might be an indication of a change in the structural integrity. The electrical impedance is measured at high frequencies with which this methodology appears to be very sensitive to incipient damage in structural systems as desired for our application. Abonded-PZT-FRP spectral beam element approach based on an extension of the previous discrete crack approach is implemented in the calculation of the electrical impedance of the PZT transducer bonded to the FRP plates of a RC beam. This approach in conjunction with the experimental measurements of PZT actuator-sensors mounted on the structure is used to present an updating methodology to quantitatively detect interfacial debonding between a FRP strip and the host RC structure. The updating procedure is solved by using an ensemble particle swarm optimization approach with abagging algorithm, and the results demonstrate a big improvement for the performance and accuracy of the damage detection in the proposed problem. Additionally, an adaptive strategy of spectral element mesh has been also developed to detect damage location with experimental results, which shows the robustness and effectiveness of the proposed method to identify initial and incipient damages at its early stage. Lastly, multi-objective optimization has been carried out to detect debonding damage in a real scale FRP-strengthened RC beam by using impedance signatures. A net of PZT sensors is distributed along the beam to construct impedance-based multiple objectives under gradually induced damage scenario. By combining the spectral element model presented previously and an ensemble multi-objective PSO algorithm, the implemented damage detection process yields satisfactory predictions considering the scale and uncertainties of the structure. The obtained results prove the feasibility and capability of the aforementioned methods and also their potentials in real engineering applications.
Resumo:
El desarrollo da las nuevas tecnologías permite a los ingenieros llevar al límite el funcionamiento de los circuitos integrados (Integrated Circuits, IC). Las nuevas generaciones de procesadores, DSPs o FPGAs son capaces de procesar la información a una alta velocidad, con un alto consumo de energía, o esperar en modo de baja potencia con el mínimo consumo posible. Esta gran variación en el consumo de potencia y el corto tiempo necesario para cambiar de un nivel al otro, afecta a las especificaciones del Módulo de Regulador de Tensión (Voltage Regulated Module, VRM) que alimenta al IC. Además, las características adicionales obligatorias, tales como adaptación del nivel de tensión (Adaptive Voltage Positioning, AVP) y escalado dinámico de la tensión (Dynamic Voltage Scaling, DVS), imponen requisitos opuestas en el diseño de la etapa de potencia del VRM. Para poder soportar las altas variaciones de los escalones de carga, el condensador de filtro de salida del VRM se ha de sobredimensionar, penalizando la densidad de energía y el rendimiento durante la operación de DVS. Por tanto, las actuales tendencias de investigación se centran en mejorar la respuesta dinámica del VRM, mientras se reduce el tamaño del condensador de salida. La reducción del condensador de salida lleva a menor coste y una prolongación de la vida del sistema ya que se podría evitar el uso de condensadores voluminosos, normalmente implementados con condensadores OSCON. Una ventaja adicional es que reduciendo el condensador de salida, el DVS se puede realizar más rápido y con menor estrés de la etapa de potencia, ya que la cantidad de carga necesaria para cambiar la tensión de salida es menor. El comportamiento dinámico del sistema con un control lineal (Control Modo Tensión, VMC, o Control Corriente de Pico, Peak Current Mode Control, PCMC,…) está limitado por la frecuencia de conmutación del convertidor y por el tamaño del filtro de salida. La reducción del condensador de salida se puede lograr incrementando la frecuencia de conmutación, así como incrementando el ancho de banda del sistema, y/o aplicando controles avanzados no-lineales. Usando esos controles, las variables del estado se saturan para conseguir el nuevo régimen permanente en un tiempo mínimo, así como el filtro de salida, más específicamente la pendiente de la corriente de la bobina, define la respuesta de la tensión de salida. Por tanto, reduciendo la inductancia de la bobina de salida, la corriente de bobina llega más rápido al nuevo régimen permanente, por lo que una menor cantidad de carga es tomada del condensador de salida durante el tránsito. El inconveniente de esa propuesta es que el rendimiento del sistema es penalizado debido al incremento de pérdidas de conmutación y las corrientes RMS. Para conseguir tanto la reducción del condensador de salida como el alto rendimiento del sistema, mientras se satisfacen las estrictas especificaciones dinámicas, un convertidor multifase es adoptado como estándar para aplicaciones VRM. Para asegurar el reparto de las corrientes entre fases, el convertidor multifase se suele implementar con control de modo de corriente. Para superar la limitación impuesta por el filtro de salida, la segunda posibilidad para reducir el condensador de salida es aplicar alguna modificación topológica (Topologic modifications) de la etapa básica de potencia para incrementar la pendiente de la corriente de bobina y así reducir la duración de tránsito. Como el transitorio se ha reducido, una menor cantidad de carga es tomada del condensador de salida bajo el mismo escalón de la corriente de salida, con lo cual, el condensador de salida se puede reducir para lograr la misma desviación de la tensión de salida. La tercera posibilidad para reducir el condensador de salida del convertidor es introducir un camino auxiliar de energía (additional energy path, AEP) para compensar el desequilibrio de la carga del condensador de salida reduciendo consecuentemente la duración del transitorio y la desviación de la tensión de salida. De esta manera, durante el régimen permanente, el sistema tiene un alto rendimiento debido a que el convertidor principal con bajo ancho de banda es diseñado para trabajar con una frecuencia de conmutación moderada para conseguir requisitos estáticos. Por otro lado, el comportamiento dinámico durante los transitorios es determinado por el AEP con un alto ancho de banda. El AEP puede ser implementado como un camino resistivo, como regulador lineal (Linear regulator, LR) o como un convertidor conmutado. Las dos primeras implementaciones proveen un mayor ancho de banda, acosta del incremento de pérdidas durante el transitorio. Por otro lado, la implementación del convertidor computado presenta menor ancho de banda, limitado por la frecuencia de conmutación, aunque produce menores pérdidas comparado con las dos anteriores implementaciones. Dependiendo de la aplicación, la implementación y la estrategia de control del sistema, hay una variedad de soluciones propuestas en el Estado del Arte (State-of-the-Art, SoA), teniendo diferentes propiedades donde una solución ofrece más ventajas que las otras, pero también unas desventajas. En general, un sistema con AEP ideal debería tener las siguientes propiedades: 1. El impacto del AEP a las pérdidas del sistema debería ser mínimo. A lo largo de la operación, el AEP genera pérdidas adicionales, con lo cual, en el caso ideal, el AEP debería trabajar por un pequeño intervalo de tiempo, solo durante los tránsitos; la otra opción es tener el AEP constantemente activo pero, por la compensación del rizado de la corriente de bobina, se generan pérdidas innecesarias. 2. El AEP debería ser activado inmediatamente para minimizar la desviación de la tensión de salida. Para conseguir una activación casi instantánea, el sistema puede ser informado por la carga antes del escalón o el sistema puede observar la corriente del condensador de salida, debido a que es la primera variable del estado que actúa a la perturbación de la corriente de salida. De esa manera, el AEP es activado con casi cero error de la tensión de salida, logrando una menor desviación de la tensión de salida. 3. El AEP debería ser desactivado una vez que el nuevo régimen permanente es detectado para evitar los transitorios adicionales de establecimiento. La mayoría de las soluciones de SoA estiman la duración del transitorio, que puede provocar un transitorio adicional si la estimación no se ha hecho correctamente (por ejemplo, si la corriente de bobina del convertidor principal tiene un nivel superior o inferior al necesitado, el regulador lento del convertidor principal tiene que compensar esa diferencia una vez que el AEP es desactivado). Otras soluciones de SoA observan las variables de estado, asegurando que el sistema llegue al nuevo régimen permanente, o pueden ser informadas por la carga. 4. Durante el transitorio, como mínimo un subsistema, o bien el convertidor principal o el AEP, debería operar en el lazo cerrado. Implementando un sistema en el lazo cerrado, preferiblemente el subsistema AEP por su ancho de banda elevado, se incrementa la robustez del sistema a los parásitos. Además, el AEP puede operar con cualquier tipo de corriente de carga. Las soluciones que funcionan en el lazo abierto suelen preformar el control de balance de carga con mínimo tiempo, así reducen la duración del transitorio y tienen un impacto menor a las pérdidas del sistema. Por otro lado, esas soluciones demuestran una alta sensibilidad a las tolerancias y parásitos de los componentes. 5. El AEP debería inyectar la corriente a la salida en una manera controlada, así se reduce el riesgo de unas corrientes elevadas y potencialmente peligrosas y se incrementa la robustez del sistema bajo las perturbaciones de la tensión de entrada. Ese problema suele ser relacionado con los sistemas donde el AEP es implementado como un convertidor auxiliar. El convertidor auxiliar es diseñado para una potencia baja, con lo cual, los dispositivos elegidos son de baja corriente/potencia. Si la corriente no es controlada, bajo un pico de tensión de entrada provocada por otro parte del sistema (por ejemplo, otro convertidor conectado al mismo bus), se puede llegar a un pico en la corriente auxiliar que puede causar la perturbación de tensión de salida e incluso el fallo de los dispositivos del convertidor auxiliar. Sin embargo, cuando la corriente es controlada, usando control del pico de corriente o control con histéresis, la corriente auxiliar tiene el control con prealimentación (feed-forward) de tensión de entrada y la corriente es definida y limitada. Por otro lado, si la solución utiliza el control de balance de carga, el sistema puede actuar de forma deficiente si la tensión de entrada tiene un valor diferente del nominal, provocando que el AEP inyecta/toma más/menos carga que necesitada. 6. Escalabilidad del sistema a convertidores multifase. Como ya ha sido comentado anteriormente, para las aplicaciones VRM por la corriente de carga elevada, el convertidor principal suele ser implementado como multifase para distribuir las perdidas entre las fases y bajar el estrés térmico de los dispositivos. Para asegurar el reparto de las corrientes, normalmente un control de modo corriente es usado. Las soluciones de SoA que usan VMC son limitadas a la implementación con solo una fase. Esta tesis propone un nuevo método de control del flujo de energía por el AEP y el convertidor principal. El concepto propuesto se basa en la inyección controlada de la corriente auxiliar al nodo de salida donde la amplitud de la corriente es n-1 veces mayor que la corriente del condensador de salida con las direcciones apropiadas. De esta manera, el AEP genera un condensador virtual cuya capacidad es n veces mayor que el condensador físico y reduce la impedancia de salida. Como el concepto propuesto reduce la impedancia de salida usando el AEP, el concepto es llamado Output Impedance Correction Circuit (OICC) concept. El concepto se desarrolla para un convertidor tipo reductor síncrono multifase con control modo de corriente CMC (incluyendo e implementación con una fase) y puede operar con la tensión de salida constante o con AVP. Además, el concepto es extendido a un convertidor de una fase con control modo de tensión VMC. Durante la operación, el control de tensión de salida de convertidor principal y control de corriente del subsistema OICC están siempre cerrados, incrementando la robustez a las tolerancias de componentes y a los parásitos del cirquito y permitiendo que el sistema se pueda enfrentar a cualquier tipo de la corriente de carga. Según el método de control propuesto, el sistema se puede encontrar en dos estados: durante el régimen permanente, el sistema se encuentra en el estado Idle y el subsistema OICC esta desactivado. Por otro lado, durante el transitorio, el sistema se encuentra en estado Activo y el subsistema OICC está activado para reducir la impedancia de salida. El cambio entre los estados se hace de forma autónoma: el sistema entra en el estado Activo observando la corriente de condensador de salida y vuelve al estado Idle cunado el nuevo régimen permanente es detectado, observando las variables del estado. La validación del concepto OICC es hecha aplicándolo a un convertidor tipo reductor síncrono con dos fases y de 30W cuyo condensador de salida tiene capacidad de 140μF, mientras el factor de multiplicación n es 15, generando en el estado Activo el condensador virtual de 2.1mF. El subsistema OICC es implementado como un convertidor tipo reductor síncrono con PCMC. Comparando el funcionamiento del convertidor con y sin el OICC, los resultados demuestran que se ha logrado una reducción de la desviación de tensión de salida con factor 12, tanto con funcionamiento básico como con funcionamiento AVP. Además, los resultados son comparados con un prototipo de referencia que tiene la misma etapa de potencia y un condensador de salida físico de 2.1mF. Los resultados demuestran que los dos sistemas tienen el mismo comportamiento dinámico. Más aun, se ha cuantificado el impacto en las pérdidas del sistema operando bajo una corriente de carga pulsante y bajo DVS. Se demuestra que el sistema con OICC mejora el rendimiento del sistema, considerando las pérdidas cuando el sistema trabaja con la carga pulsante y con DVS. Por lo último, el condensador de salida de sistema con OICC es mucho más pequeño que el condensador de salida del convertidor de referencia, con lo cual, por usar el concepto OICC, la densidad de energía se incrementa. En resumen, las contribuciones principales de la tesis son: • El concepto propuesto de Output Impedance Correction Circuit (OICC), • El control a nivel de sistema basado en el método usado para cambiar los estados de operación, • La implementación del subsistema OICC en lazo cerrado conjunto con la implementación del convertidor principal, • La cuantificación de las perdidas dinámicas bajo la carga pulsante y bajo la operación DVS, y • La robustez del sistema bajo la variación del condensador de salida y bajo los escalones de carga consecutiva. ABSTRACT Development of new technologies allows engineers to push the performance of the integrated circuits to its limits. New generations of processors, DSPs or FPGAs are able to process information with high speed and high consumption or to wait in low power mode with minimum possible consumption. This huge variation in power consumption and the short time needed to change from one level to another, affect the specifications of the Voltage Regulated Module (VRM) that supplies the IC. Furthermore, additional mandatory features, such as Adaptive Voltage Positioning (AVP) and Dynamic Voltage Scaling (DVS), impose opposite trends on the design of the VRM power stage. In order to cope with high load-step amplitudes, the output capacitor of the VRM power stage output filter is drastically oversized, penalizing power density and the efficiency during the DVS operation. Therefore, the ongoing research trend is directed to improve the dynamic response of the VRM while reducing the size of the output capacitor. The output capacitor reduction leads to a smaller cost and longer life-time of the system since the big bulk capacitors, usually implemented with OSCON capacitors, may not be needed to achieve the desired dynamic behavior. An additional advantage is that, by reducing the output capacitance, dynamic voltage scaling (DVS) can be performed faster and with smaller stress on the power stage, since the needed amount of charge to change the output voltage is smaller. The dynamic behavior of the system with a linear control (Voltage mode control, VMC, Peak Current Mode Control, PCMC,…) is limited by the converter switching frequency and filter size. The reduction of the output capacitor can be achieved by increasing the switching frequency of the converter, thus increasing the bandwidth of the system, and/or by applying advanced non-linear controls. Applying nonlinear control, the system variables get saturated in order to reach the new steady-state in a minimum time, thus the output filter, more specifically the output inductor current slew-rate, determines the output voltage response. Therefore, by reducing the output inductor value, the inductor current reaches faster the new steady state, so a smaller amount of charge is taken from the output capacitor during the transient. The drawback of this approach is that the system efficiency is penalized due to increased switching losses and RMS currents. In order to achieve both the output capacitor reduction and high system efficiency, while satisfying strict dynamic specifications, a Multiphase converter system is adopted as a standard for VRM applications. In order to ensure the current sharing among the phases, the multiphase converter is usually implemented with current mode control. In order to overcome the limitation imposed by the output filter, the second possibility to reduce the output capacitor is to apply Topologic modifications of the basic power stage topology in order to increase the slew-rate of the inductor current and, therefore, reduce the transient duration. Since the transient is reduced, smaller amount of charge is taken from the output capacitor under the same load current, thus, the output capacitor can be reduced to achieve the same output voltage deviation. The third possibility to reduce the output capacitor of the converter is to introduce an additional energy path (AEP) to compensate the charge unbalance of the output capacitor, consequently reducing the transient time and output voltage deviation. Doing so, during the steady-state operation the system has high efficiency because the main low-bandwidth converter is designed to operate at moderate switching frequency, to meet the static requirements, whereas the dynamic behavior during the transients is determined by the high-bandwidth auxiliary energy path. The auxiliary energy path can be implemented as a resistive path, as a Linear regulator, LR, or as a switching converter. The first two implementations provide higher bandwidth, at the expense of increasing losses during the transient. On the other hand, the switching converter implementation presents lower bandwidth, limited by the auxiliary converter switching frequency, though it produces smaller losses compared to the two previous implementations. Depending on the application, the implementation and the control strategy of the system, there is a variety of proposed solutions in the State-of-the-Art (SoA), having different features where one solution offers some advantages over the others, but also some disadvantages. In general, an ideal additional energy path system should have the following features: 1. The impact on the system losses should be minimal. During its operation, the AEP generates additional losses, thus ideally, the AEP should operate for a short period of time, only when the transient is occurring; the other option is to have the AEP constantly on, but due to the inductor current ripple compensation at the output, unnecessary losses are generated. 2. The AEP should be activated nearly instantaneously to prevent bigger output voltage deviation. To achieve near instantaneous activation, the converter system can be informed by the load prior to the load-step or the system can observe the output capacitor current, which is the first system state variable that reacts on the load current perturbation. In this manner, the AEP is turned on with near zero output voltage error, providing smaller output voltage deviation. 3. The AEP should be deactivated once the new steady state is reached to avoid additional settling transients. Most of the SoA solutions estimate duration of the transient which may cause additional transient if the estimation is not performed correctly (e.g. if the main converter inductor current has higher or lower value than needed, the slow regulator of the main converter needs to compensate the difference after the AEP is deactivated). Other SoA solutions are observing state variables, ensuring that the system reaches the new steady state or they are informed by the load. 4. During the transient, at least one subsystem, either the main converter or the AEP, should be in closed-loop. Implementing a closed loop system, preferably the AEP subsystem, due its higher bandwidth, increases the robustness under system tolerances and circuit parasitic. In addition, the AEP can operate with any type of load. The solutions that operate in open loop usually perform minimum time charge balance control, thus reducing the transient length and minimizing the impact on the losses, however they are very sensitive to tolerances and parasitics. 5. The AEP should inject current at the output in a controlled manner, thus reducing the risk of high and potentially damaging currents and increasing robustness on the input voltage deviation. This issue is mainly related to the systems where AEP is implemented as auxiliary converter. The auxiliary converter is designed for small power and, as such, the MOSFETs are rated for small power/currents. If the current is not controlled, due to the some unpredicted spike in input voltage caused by some other part of the system (e.g. different converter), it may lead to a current spike in auxiliary current which will cause the perturbation of the output voltage and even failure of the switching components of auxiliary converter. In the case when the current is controlled, using peak CMC or Hysteretic Window CMC, the auxiliary converter has inherent feed-forwarding of the input voltage in current control and the current is defined and limited. Furthermore, if the solution employs charge balance control, the system may perform poorly if the input voltage has different value than the nominal, causing that AEP injects/extracts more/less charge than needed. 6. Scalability of the system to multiphase converters. As commented previously, in VRM applications, due to the high load currents, the main converters are implemented as multiphase to redistribute losses among the modules, lowering temperature stress of the components. To ensure the current sharing, usually a Current Mode Control (CMC) is employed. The SoA solutions that are implemented with VMC are limited to a single stage implementation. This thesis proposes a novel control method of the energy flow through the AEP and the main converter system. The proposed concept relays on a controlled injection of the auxiliary current at the output node where the instantaneous current value is n-1 times bigger than the output capacitor current with appropriate directions. Doing so, the AEP creates an equivalent n times bigger virtual capacitor at the output, thus reducing the output impedance. Due to the fact that the proposed concept reduces the output impedance using the AEP, it has been named the Output Impedance Correction Circuit (OICC) concept. The concept is developed for a multiphase CMC synchronous buck converter (including a single phase implementation), operating with a constant output voltage and with AVP feature. Further, it is extended to a single phase VMC synchronous buck converter. During the operation, the main converter voltage loop and the OICC subsystem capacitor current loop is constantly closed, increasing the robustness under system tolerances and circuit parasitic and allowing the system to operate with any load-current shape or pattern. According to the proposed control method, the system operates in two states: during the steady-state the system is in the Idle state and the OICC subsystem is deactivated, while during the load-step transient the system is in the Active state and the OICC subsystem is activated in order to reduce the output impedance. The state changes are performed autonomously: the system enters in the Active state by observing the output capacitor current and it returns back to the Idle state when the steady-state operation is detected by observing the state variables. The validation of the OICC concept has been done by applying it to a 30W two phase synchronous buck converter with 140μF output capacitor and with the multiplication factor n equal to 15, generating during the Active state equivalent output capacitor of 2.1mF. The OICC subsystem is implemented as single phase PCMC synchronous buck converter. Comparing the converter operation with and without the OICC the results demonstrate that the 12 times reduction of the output voltage deviation is achieved, for both basic operation and for the AVP operation. Furthermore, the results have been compared to a reference prototype which has the same power stage and a fiscal output capacitor of 2.1mF. The results show that the two systems have the same dynamic behavior. Moreover, an impact on the system losses under the pulsating load and DVS operation has been quantified and it has been demonstrated that the OICC system has improved the system efficiency, considering the losses when the system operates with the pulsating load and the DVS operation. Lastly, the output capacitor of the OICC system is much smaller than the reference design output capacitor, therefore, by applying the OICC concept the power density can be increased. In summary, the main contributions of the thesis are: • The proposed Output Impedance Correction Circuit (OICC) concept, • The system level control based on the used approach to change the states of operation, • The OICC subsystem closed-loop implementation, together with the main converter implementation, • The dynamic losses under the pulsating load and the DVS operation quantification, and • The system robustness on the capacitor impedance variation and consecutive load-steps.
Resumo:
El diagnóstico y detección temprana de enfermedades son clave para reducir la tasa de mortalidad, las hospitalizaciones de larga duración y el desaprovechamiento de recursos. En los últimos años se ha impulsado, mediante un aumento de la financiación, el desarrollo de nuevos biosensores de bajo coste capaces de detectar y cuantificar cantidades muy pequeñas de especies biológicas de una forma barata y sencilla. El trabajo presentado en esta Tesis Doctoral describe la investigación llevada a cabo en el desarrollo de sensores gravimétricos basados en resonadores de ondas acústicas de volumen (BAW) de estructura maciza (SMR). Los dispositivos emplean películas delgadas de A1N como material piezoeléctrico y operan en modo de cizalladura, para así poder detectar especies biológicas en medio líquido. El principio de funcionamiento de estos sensores se basa en la variación que experimenta la frecuencia de resonancia al quedar una pequeña masa adherida a su superficie. Necesitan operar en modo de cizalladura para que su resonancia no se atenúe al trabajar en medio líquido, así como ofrecer una superficie capaz de ser funcionalizada específicamente para la especie biológica a detectar. El reto planteado en esta tesis requiere un acercamiento pluridisciplinar al problema que incluye el estudio de los diferentes materiales que constituyen la estructura multicapa que forma un SMR, el diseño y fabricación del dispositivo y del sistema de fluídica, la funcionalización bioquímica de la superficie del sensor, la demostración de la capacidad de detección de especies biológicas y finalmente el diseño y fabricación de la electrónica asociada para la detección de la señal eléctrica. Todas esas tareas han sido abordadas en las distintas etapas del desarrollo de esta tesis y las contribuciones más relevantes se describen en el documento. En el campo de desarrollo de los materiales, se propone un proceso en dos etapas para la pulverización reactiva de capas de A1N que contengan microcristales inclinados capaces de excitar el modo de cizalladura. Se caracteriza la velocidad acústica del modo de cizalladura en todos los materiales que componen la estructura, con el fin de poder obtener un diseño más adecuado del reflector acústico. Se propone un nuevo tipo de material aislante de alta impedancia acústica consistente en capas de W03 pulverizadas que presenta ciertas ventajas tecnológicas frente a las capas convencionales de Ta205. Respecto del diseño del transductor, se estudia la influencia que tienen los con tactos eléctricos extendidos del resonador necesarios para poder adaptar el sistema de fluídica a la estructura. Los resultados indican que es necesario trabajar sobre sustratos aislantes (tanto el soporte como el espejo acústico) para evitar efectos parásitos asociados al uso de capas metálicas bajo los electrodos del resonador que dañan su resonancia. Se analiza la influencia de las diferentes capas del dispositivo en el coeficiente de temperatura de la frecuencia (TCF) del resonador llegando a la conclusión de que las dos últimas capas del reflector acústico afectan significativamente al TCF del SMR, pudiendo reducirse ajusfando adecuadamente sus espesores. De acuerdo con los resultados de estos estudios, se han diseñado finalmente resonadores SMR operando a f .3 GHz en modo de cizalladura, con un área activa de 65000 /xm2, contactos eléctricos que se extienden f .7 mm y factores de calidad en líquido de f 50. Las extensiones eléctricas permiten adaptar el resonador a un sistema de fluídica de metacrilato. Para la detección de especies biológicas se realiza un montaje experimental que permite circular 800 ¡A por la superficie del sensor a través de un circuito cerrado que trabaja a volumen constante. La circulación de soluciones iónicas sobre el sensor descubierto pone de manifiesto que las altas frecuencias de operación previenen los cortocircuitos y por tanto el aislamiento de los electrodos es prescindible. Se desarrolla un protocolo ad-hoc de funcionalización basado en el proceso estándar APTESGlutaraldehído. Se proponen dos alternativas novedosas para la funcionalización de las áreas activas del sensor basadas en el uso de capas de oxidación de Ir02 y su activación a través de un plasma de oxígeno que no daña al dispositivo. Ambos procesos contribuyen a simplificar notablemente la funcionalización de los sensores gravimétricos. Se utilizan anticuerpos y aptámeros como receptores para detectar trombina, anticuerpo monoclonal IgG de ratón y bacteria sonicadas. Una calibración preliminar del sensor con depósitos de capas finas de Si02 de densidad y espesor conocidos permite obtener una sensibilidad de 1800 kHz/pg-cm2 y un límite de detección of 4.2 pg. Finalmente se propone el prototipo de un circuito electrónico de excitación y lectura de bajo coste diseñado empleando teoría de circuitos de microondas. Aunque su diseño y funcionamiento admite mejoras, constituye la última etapa de un sistema completo de bajo coste para el diagnóstico de especies biológicas basado en resonadores SMR de A1N. ABSTRACT Early diagnosis and detection of diseases are essential for reducing mortality rate and preventing long-term hospitalization and waste of resources. These requirements have boosted the efforts and funding on the research of accurate and reliable means for detection and quantification of biological species, also known as biosensors. The work presented in this thesis describes the development and fabrication of gravimetric biosensors based on piezoelectric AlN bulk acoustic wave (BAW) solidly mounted resonators (SMRs) for detection of biological species in liquid media. These type of devices base their sensing principles in the variation that their resonant frequency suffers when a mass is attached to their surface. They need to operate in the shear mode to maintain a strong resonance in liquid and an adequate functionalisation of their sensing area to guarantee that only the targeted molecules cause the shift. The challenges that need to be overcome to achieve piezoelectric BAW resonators for high sensitivity detection in fluids require a multidisciplinary approach, that include the study of the materials involved, the design of the device and the fluidic system, the biochemical functionalisation of the active area, the experimental proof-of-concept with different target species and the design of an electronic readout circuit. All this tasks have been tackled at different stages of the thesis and the relevant contributions are described in the document. In the field of materials, a two-stage sputtering deposition process has been developed to obtain good-quality AlN films with uniformly tilted grains required to excite the shear mode. The shear acoustic velocities of the materials composing the acoustic reflector have been accurately studied to ensure an optimum design of the reflector stack. WO3 sputtered films have been proposed as high acoustic impedance material for insulating acoustic reflectors. They display several technological advantages for the processing of the resonators. Regarding the design, a study of the influence of the electrical extensions necessary to fit a fluidic system on the performance of the devices has been performed. The results indicate that high resistivity substrates and insulating reflectors are necessary to avoid the hindering of the resonance due to the parasitic effects induced by the extensions. The influence of the different layers of the stack on the resultant TCF of the SMRs has also been investigated. The two layers of the reflector closer to the piezoelectric layer have a significant influence on the TCF, which can be reduced by modifying their thicknesses accordingly. The data provided by these studies has led to the final design of the devices, which operate at 1.3 GHz in the shear mode and display an active area of 65000 /xm2 and electrical extensions of 1.7 mm while keeping a Qahear=150 in liquid. The extensions enable to fit a custom-made fluidic system made of methacrylate. To perform the biosensing experiments, an experimental setup with a liquid closed circuit operating at constant flow has been developed. Buffers of ionic characteristics have been tested on non-isolated devices, revealing that high operation frequencies prevent the risk of short circuit. An ad-hoc functionalisation protocol based on the standard APTES - Glutaraldehyde process has been developed. It includes two new processes that simplify the fabrication of the transducers: the use of IrO2 as oxidation layer and its functionalisation through an O2 plasma treatment that does not damage the resonators. Both antibodies and aptamers are used as receptors. In liquid sensing proof-of-concept experiments with thrombin, IgG mouse monoclonal antibody and sonicated bacteria have been displayed. A preliminary calibration of the devices using SiO2 layers reveals a sensitivity of 1800 kHz/pg-cm2 and a limit of detection of 4.2 pg. Finally, a first prototype of a low-cost electronic readout circuit designed using a standard microwave approach has been developed. Although its performance can be significantly improved, it is an effective first approach to the final stage of a portable low-cost diagnostic system based on shear mode AlN SMRs.
Resumo:
Los objetivos de esta tesis fueron 1) obtener y validar ecuaciones de predicción para determinar in vivo la composición corporal y de la canal de conejos en crecimiento de 25 a 77 días de vida utilizando la técnica de la Impedancia Bioeléctrica (BIA), y 2) evaluar su aplicación para determinar diferencias en la composición corporal y de la canal, así como la retención de nutrientes de animales alimentados con diferentes fuentes y niveles de grasa. El primer estudio se realizó para determinar y después validar, usando datos independientes, las ecuaciones de predicción obtenidas para determinar in vivo la composición corporal de los conejos en crecimiento. Se utilizaron 150 conejos a 5 edades distintas (25, 35, 49, 63 y 77 días de vida), con un rango de pesos entre 231 y 3138 g. Para determinar los valores de resistencia (Rs,) and reactancia (Xc,) se usó un terminal (Model BIA-101, RJL Systems, Detroit, MI USA) con cuatro electrodos. Igualmente se registró la distancia entre electrodos internos (D), la longitud corporal (L) y el peso vivo (PV) de cada animal. En cada edad, los animales fueron molidos y congelados (-20 ºC) para su posterior análisis químico (MS, grasa, proteína, cenizas y EB). El contenido en grasa y energía de los animales se incrementó, mientras que los contenidos en proteína, cenizas y agua de los animales disminuyeron con la edad. Los valores medios de Rs, Xc, impedancia (Z), L y D fueron 83.5 ± 23.1 , 18.2 ± 3.8 , 85.6 ± 22.9 , 30.6 ± 6.9 cm y 10.8 ± 3.1 cm. Se realizó un análisis de regresión lineal múltiple para determinar las ecuaciones de predicción, utilizando los valores de PV, L and Z como variables independientes. Las ecuaciones obtenidas para estimar los contenidos en agua (g), PB (g), grasa (g), cenizas (g) and EB (MJ) tuvieron un coeficiente de determinación de (R2) de 0.99, 0.99, 0.97, 0.98 y 0.99, y los errores medios de predicción relativos (EMPR) fueron: 2.79, 6.15, 24.3, 15.2 y 10.6%, respectivamente. Cuando el contenido en agua se expresó como porcentaje, los valores de R2 y EMPR fueron 0.85 and 2.30%, respectivamente. Al predecir los contenidos en proteína (%MS), grasa (%MS), cenizas (%MS) y energía (kJ/100 g MS), se obtuvieron valores de 0.79, 0.83, 0.71 y 0.86 para R2, y 5.04, 18.9, 12.0 y 3.19% para EMPR. La reactancia estuvo negativamente correlacionada con el contenido en agua, cenizas y PB (r = -0.32, P < 0.0001; r = -0.20, P < 0.05; r = -0.26, P < 0.01) y positivamente correlacionada con la grasa y la energía (r = 0.23 y r = 0.24; P < 0.01). Sin embargo, Rs estuvo positivamente correlacionada con el agua, las cenizas y la PB (r = 0.31, P < 0.001; r = 0.28, P < 0.001; r = 0.37, P < 0.0001) y negativamente con la grasa y la energía (r = -0.36 y r = -0.35; P < 0.0001). Igualmente la edad estuvo negativamente correlacionada con el contenido en agua, cenizas y proteína (r = -0.79; r = -0.68 y r = -0.80; P < 0.0001) y positivamente con la grasa y la energía (r = 0.78 y r = 0.81; P < 0.0001). Se puede concluir que el método BIA es una técnica buena y no invasiva para estimar in vivo la composición corporal de conejos en crecimiento de 25 a 77 días de vida. El objetivo del segundo estudio fue determinar y validar con datos independientes las ecuaciones de predicción obtenidas para estimar in vivo la composición de la canal eviscerada mediante el uso de BIA en un grupo de conejos de 25 a 77 días, así como testar su aplicación para predecir la retención de nutrientes y calcular las eficacias de retención de la energía y del nitrógeno. Se utilizaron 75 conejos agrupados en 5 edades (25, 35, 49, 63 y 77 días de vida) con unos pesos que variaron entre 196 y 3260 g. Para determinar los valores de resistencia (Rs, ) y reactancia (Xc, ) se usó un terminal (Model BIA-101, RJL Systems, Detroit, MI USA) con cuatro electrodos. Igualmente se registró la distancia entre electrodos internos (D), la longitud corporal (L) y el peso vivo (PV) del cada animal. En cada edad, los animales fueron aturdidos y desangrados. Su piel, vísceras y contenido digestivo fueron retirados, y la canal oreada fue pesada y molida para posteriores análisis (MS, grasa, PB, cenizas y EB). Los contenidos en energía y grasa aumentaron mientras que los de agua, cenizas y proteína disminuyeron con la edad. Los valores medios de Rs, Xc, impedancia (Z), L y D fueron 95.9±23.9 , 19.5±4.7 , 98.0±23.8 , 20.6±6.3 cm y 13.7±3.1 cm. Se realizó un análisis de regresión linear múltiple para determinar las ecuaciones de predicción, utilizando los valores de PV, L and Z como variables independientes. Los coeficientes de determinación (R2) de las ecuaciones obtenidas para estimar los contenidos en agua (g), PB (g), grasa (g), cenizas (g) and EB (MJ) fueron: 0.99, 0.99, 0.95, 0.96 y 0.98, mientras que los errores medios de predicción relativos (EMPR) fueron: 4.20, 5.48, 21.9, 9.10 y 6.77%, respectivamente. Cuando el contenido en agua se expresó como porcentaje, los valores de R2 y EMPR fueron 0.79 y 1.62%, respectivamente. Cuando se realizó la predicción de los contenidos en proteína (%MS), grasa (%MS), cenizas (%MS) y energía (kJ/100 g MS), los valores de R2 fueron 0.68, 0.76, 0.66 and 0.82, y los de RMPE: 3.22, 10.5, 5.82 and 2.54%, respectivamente. La reactancia estuvo directamente correlacionada con el contenido en grasa (r = 0.24, P < 0.05), mientras que la resistencia guardó una correlación positiva con los contenidos en agua, cenizas y proteína (r = 0.55, P < 0.001; r = 0.54, P < 0.001; r = 0.40, P < 0.005) y negativa con la grasa y la energía (r = -0.44 y r = -0.55; P < 0.001). Igualmente la edad estuvo negativamente correlacionada con los contenidos en agua, cenizas y PB (r = -0.94; r = -0.85 y r = -0.75; P < 0.0001) y positivamente con la grasa y la energía (r = 0.89 y r = 0.90; P < 0.0001). Se estudió la eficacia global de retención de la energía (ERE) y del nitrógeno (ERN) durante todo el periodo de cebo (35-63 d), Los valores de ERE fueron 20.4±7.29%, 21.0±4.18% and 20.8±2.79% en los periodos 35 a 49, 49 a 63 y 35 a 63 d, respectivamente. ERN fue 46.9±11.7%, 34.5±7.32% y 39.1±3.23% para los mismos periodos. La energía fue retenida en los tejidos para crecimiento con una eficiencia del 52.5% y la eficiencia de retención de la energía como proteína y grasa fue de 33.3 y 69.9% respectivamente. La eficiencia de utilización del nitrógeno para crecimiento fue cercana al 77%. Este trabajo muestra como el método BIA es técnica buena y no invasiva para determinar in vivo la composición de la canal y la retención de nutrientes en conejos en crecimiento de 25 a 77 días de vida. En el tercer estudio, se llevaron a cabo dos experimentos con el fin de investigar los efectos del nivel de inclusión y de la fuente de grasa, sobre los rendimientos productivos, la mortalidad, la retención de nutrientes y la composición corporal total y de la canal eviscerada de conejos en crecimiento de 34 a 63 d de vida. En el Exp. 1 se formularon 3 dietas con un diseño experimental factorial 3 x 2 con el tipo de grasa utilizada: Aceite de Soja (SBO), Lecitinas de Soja (SLO) y Manteca (L) y el nivel de inclusión (1.5 y 4%) como factores principales. El Exp. 2 también fue diseñado con una estructura factorial 3 x 2, pero usando SBO, Aceite de Pescado (FO) y Aceite de Palmiste como fuentes de grasa, incluidas a los mismos niveles que en el Exp. 1. En ambos experimentos 180 animales fueron alojados en jaulas individuales (n=30) y 600 en jaulas colectivas en grupos de 5 animales (n=20). Los animales alimentados con un 4% de grasa añadida tuvieron unos consumos diarios y unos índices de conversión más bajos que aquellos alimentados con las dietas con un 1.5% de grasa. En los animales alojados en colectivo del Exp. 1, el consumo fue un 4.8% más alto en los que consumieron las dietas que contenían manteca que en los animales alimentados con las dietas SBO (P = 0.036). La inclusión de manteca tendió a reducir la mortalidad (P = 0.067) en torno al 60% y al 25% con respecto a las dietas con SBO y SLO, respectivamente. La mortalidad aumentó con el nivel máximo de inclusión de SLO (14% vs. 1%, P < 0.01), sin observarse un efecto negativo sobre la mortalidad con el nivel más alto de inclusión de las demás fuentes de grasa utilizadas. En los animales alojados colectivo del Exp. 2 se encontró una disminución del consumo (11%), peso vivo a 63 d (4.8%) y de la ganancia diaria de peso (7.8%) con la inclusión de aceite de pescado con respecto a otras dietas (P < 0.01). Los dos últimos parámetros se vieron especialmente más reducidos cuando en las dietas se incluyó el nivel más alto de FO (5.6 y 9.5%, respectivamente, (P < 0.01)). Los animales alojados individualmente mostraron unos resultados productivos muy similares. La inclusión de aceite pescado tendió (P = 0.078) a aumentar la mortalidad (13.2%) con respecto al aceite de palmiste (6.45%), siendo intermedia para las dietas que contenían SBO (8.10%). La fuente o el nivel de grasa no afectaron la composición corporal total o de la canal eviscerada de los animales. Un incremento en el nivel de grasa dio lugar a una disminución de la ingesta de nitrógeno digestible (DNi) (1.83 vs. 1.92 g/d; P = 0.068 en Exp. 1 y 1.79 vs. 1.95 g/d; P = 0.014 en Exp. 2). Debido a que el nitrógeno retenido (NR) en la canal fue similar para ambos niveles (0.68 g/d (Exp. 1) y 0.71 g/d (Exp. 2)), la eficacia total de retención del nitrógeno (ERN) aumentó con el nivel máximo de inclusión de grasa, pero de forma significativa únicamente en el Exp. 1 (34.9 vs. 37.8%; P < 0.0001), mientras que en el Exp. 2 se encontró una tendencia (36.2 vs. 38.0% en Exp. 2; P < 0.064). Como consecuencia, la excreción de nitrógeno en heces fue menor en los animales alimentados con el nivel más alto de grasa (0.782 vs. 0.868 g/d; P = 0.0001 en Exp. 1, y 0.745 vs. 0.865 g/d; P < 0.0001 en Exp.2) al igual que el nitrógeno excretado en orina (0.702 vs. 0.822 g/d; P < 0.0001 en Exp. 1 y 0.694 vs. 0.7999 g/d; P = 0.014 en Exp.2). Aunque no hubo diferencias en la eficacia total de retención de la energía (ERE), la energía excretada en heces disminuyó al aumentar el nivel de inclusión de grasa (142 vs. 156 Kcal/d; P = 0.0004 en Exp. 1 y 144 vs. 154 g/d; P = 0.050 en Exp. 2). Sin embargo, la energía excretada como orina y en forma de calor fue mayor en el los animales del Exp. 1 alimentados con el nivel más alto de grasa (216 vs. 204 Kcal/d; P < 0.017). Se puede concluir que la manteca y el aceite de palmiste pueden ser considerados como fuentes alternativas al aceite de soja debido a la reducción de la mortalidad, sin efectos negativos sobre los rendimientos productivos o la retención de nutrientes. La inclusión de aceite de pescado empeoró los rendimientos productivos y la mortalidad durante el periodo de crecimiento. Un aumento en el nivel de grasa mejoró el índice de conversión y la eficacia total de retención de nitrógeno. ABSTRACT The aim of this Thesis is: 1) to obtain and validate prediction equations to determine in vivo whole body and carcass composition using the Bioelectrical Impedance (BIA) method in growing rabbits from 25 to 77 days of age, and 2) to study its application to determine differences on whole body and carcass chemical composition, and nutrient retention of animals fed different fat levels and sources. The first study was conducted to determine and later validate, by using independent data, the prediction equations obtained to assess in vivo the whole body composition of growing rabbits. One hundred and fifty rabbits grouped at 5 different ages (25, 35, 49, 63 and 77 days) and weighing from 231 to 3138 g were used. A four terminal body composition analyser was used to obtain resistance (Rs, ) and reactance (Xc, ) values (Model BIA-101, RJL Systems, Detroit, MI USA). The distance between internal electrodes (D, cm), body length (L, cm) and live BW of each animal were also registered. At each selected age, animals were slaughtered, ground and frozen (-20 ºC) for later chemical analyses (DM, fat, CP, ash and GE). Fat and energy body content increased with the age, while protein, ash, and water decreased. Mean values of Rs, Xc, impedance (Z), L and D were 83.5 ± 23.1 , 18.2 ± 3.8 , 85.6 ± 22.9 , 30.6 ± 6.9 cm and 10.8 ± 3.1 cm. A multiple linear regression analysis was used to determine the prediction equations, using BW, L and Z data as independent variables. Equations obtained to estimate water (g), CP (g), fat (g), ash (g) and GE (MJ) content had, respectively, coefficient of determination (R2) values of 0.99, 0.99, 0.97, 0.98 and 0.99, and the relative mean prediction error (RMPE) was: 2.79, 6.15, 24.3, 15.2 and 10.6%, respectively. When water was expressed as percentage, the R2 and RMPE were 0.85 and 2.30%, respectively. When prediction of the content of protein (%DM), fat (%DM), ash (%DM) and energy (kJ/100 g DM) was done, values of 0.79, 0.83, 0.71 and 0.86 for R2, and 5.04, 18.9, 12.0 and 3.19% for RMPE, respectively, were obtained. Reactance was negatively correlated with water, ash and CP content (r = -0.32, P < 0.0001; r = -0.20, P < 0.05; r = -0.26, P < 0.01) and positively correlated with fat and GE (r = 0.23 and r = 0.24; P < 0.01). Otherwise, resistance was positively correlated with water, ash and CP (r = 0.31, P < 0.001; r = 0.28, P < 0.001; r = 0.37, P < 0.0001) and negatively correlated with fat and energy (r = -0.36 and r = -0.35; P < 0.0001). Moreover, age was negatively correlated with water, ash and CP content (r = -0.79; r = -0.68 and r = -0.80; P < 0.0001) and positively correlated with fat and energy (r = 0.78 and r = 0.81; P < 0.0001). It could be concluded that BIA is a non-invasive good method to estimate in vivo whole body composition of growing rabbits from 25 to 77 days of age. The aim of the second study was to determine and validate with independent data, the prediction equations obtained to estimate in vivo carcass composition of growing rabbits by using the results of carcass chemical composition and BIA values in a group of rabbits from 25 to 77 days. Also its potential application to predict nutrient retention and overall energy and nitrogen retention efficiencies was analysed. Seventy five rabbits grouped at 5 different ages (25, 35, 49, 63 and 77 days) with weights ranging from 196 to 3260 g were used. A four terminal body composition analyser (Model BIA-101, RJL Systems, Detroit, MI USA) was used to obtain resistance (Rs, ) and reactance (Xc, ) values. The distance between internal electrodes (D, cm), body length (L, cm) and live weight (BW, g) were also registered. At each selected age, all the animals were stunned and bled. The skin, organs and digestive content were removed, and the chilled carcass were weighed and processed for chemical analyses (DM, fat, CP, ash and GE). Energy and fat increased with the age, while CP, ash, and water decreased. Mean values of Rs, Xc, impedance (Z), L and D were 95.9±23.9 , 19.5±4.7 , 98.0±23.8 , 20.6±6.3 cm y 13.7±3.1 cm. A multiple linear regression analysis was done to determine the equations, using BW, L and Z data as parameters. Coefficient of determination (R2) of the equations obtained to estimate water (g), CP (g), fat (g), ash (g) and GE (MJ) content were: 0.99, 0.99, 0.95, 0.96 and 0.98, and relative mean prediction error (RMPE) were: 4.20, 5.48, 21.9, 9.10 and 6.77%, respectively. When water content was expressed as percentage, the R2 and RMPE were 0.79 and 1.62%, respectively. When prediction of protein (%DM), fat (%DM), ash (%DM) and energy (kJ/100 g DM) content was done, R2 values were 0.68, 0.76, 0.66 and 0.82, and RMPE: 3.22, 10.5, 5.82 and 2.54%, respectively. Reactance was positively correlated with fat content (r = 0.24, P < 0.05) while resistance was positively correlated with water, ash and protein carcass content (r = 0.55, P < 0.001; r = 0.54, P < 0.001; r = 0.40, P < 0.005) and negatively correlated with fat and energy (r = -0.44 and r = -0.55; P < 0.001). Moreover, age was negatively correlated with water, ash and CP content (r = -0.97, r = -0.95 and r = -0.89, P < 0.0001) and positively correlated with fat and GE (r = 0.95 and r = 0.97; P < 0.0001). In the whole growing period (35-63 d), overall energy retention efficiency (ERE) and nitrogen retention efficiency (NRE) were studied. The ERE values were 20.4±7.29%, 21.0±4.18% and 20.8±2.79%, from 35 to 49, 49 to 63 and from 35 to 63 d, respectively. NRE was 46.9±11.7%, 34.5±7.32% and 39.1±3.23% for the same periods. Energy was retained in body tissues for growth with an efficiency of approximately 52.5% and efficiency of the energy for protein and fat retention was 33.3 and 69.9%, respectively. Efficiency of utilization of nitrogen for growth was near to 77%. This work shows that BIA it’s a non-invasive and good method to estimate in vivo carcass composition and nutrient retention of growing rabbits from 25 to 77 days of age. In the third study, two experiments were conducted to investigate the effect of the fat addition and source, on performance, mortality, nutrient retention, and the whole body and carcass chemical composition of growing rabbits from 34 to 63 d. In Exp. 1 three diets were arranged in a 3 x 2 factorial structure with the source of fat: Soybean oil (SBO), Soya Lecithin Oil (SLO) and Lard (L) and the dietary fat inclusion level (1.5 and 4%) as the main factors. Exp. 2 had also arranged as a 3 x 2 factorial design, but using SBO, Fish Oil (FO) and Palmkernel Oil (PKO) as fat sources, and included at the same levels than in Exp. 1. In both experiments 180 animals were allocated in individual cages (n=30) and 600 in collectives cages, in groups of 5 animals (n=20). Animals fed with 4% dietary fat level showed lower DFI and FCR than those fed diets with 1.5%. In collective housing of Exp. 1, DFI was a 4.8% higher in animals fed with diets containing lard than SBO (P = 0.036), being intermediate for diet with SLO. Inclusion of lard also tended to reduce mortality (P = 0.067) around 60% and 25% with respect SBO and SLO diets, respectively. Mortality increased with the greatest level of soya lecithin (14% vs. 1%, P < 0.01). In Exp. 2 a decrease of DFI (11%), BW at 63 d (4.8%) and DWG (7.8%) were observed with the inclusion of fish oil with respect the other two diets (P < 0.01). These last two traits impaired with the highest level of fish oil (5.6 and 9.5%, respectively, (P < 0.01)). Animals housed individually showed similar performance results. The inclusion of fish oil also tended to increase (P = 0.078) mortality (13.2%) with respect palmkernel oil (6.45%), being mortality of SBO intermediate (8.10%). Fat source and level did not affect the whole body or carcass chemical composition. An increase of the fat sources addition led to a decrease of the digestible nitrogen intake (DNi) (1.83 vs. 1.92 g/d; P = 0.068 in Exp. 1 and 1.79 vs. 1.95 g/d; P = 0.014 in Exp. 2). As the nitrogen retained (NR) in the carcass was similar for both fat levels (0.68 g/d (Exp. 1) and 0.71 g/d (Exp. 2)), the overall efficiency of N retention (NRE) increased with the highest level of fat, but only reached significant level in Exp. 1 (34.9 vs. 37.8%; P < 0.0001), while in Exp. 2 a tendency was found (36.2 vs. 38.0% in Exp. 2; P < 0.064). Consequently, nitrogen excretion in faeces was lower in animals fed with the highest level of fat (0.782 vs. 0.868 g/d; P = 0.0001 in Exp. 1, and 0.745 vs. 0.865 g/d; P < 0.0001 in Exp.2). The same effect was observed with the nitrogen excreted as urine (0.702 vs. 0.822 g/d; P < 0.0001 in Exp. 1 and 0.694 vs. 0.7999 g/d; P = 0.014 in Exp.2). Although there were not differences in ERE, the energy excreted in faeces decreased as fat level increased (142 vs. 156 Kcal/d; P = 0.0004 in Exp. 1 and 144 vs. 154 g/d; P = 0.050 in Exp. 2). In Exp. 1 the energy excreted as urine and heat production was significantly higher when animals were fed with the highest level of dietary fat (216 vs. 204 Kcal/d; P < 0.017). It can be concluded that lard and palmkernel oil can be considered as alternative sources to soybean oil due to the reduction of the mortality, without negative effects on performances or nutrient retention. Inclusion of fish impaired animals´ productivity and mortality. An increase of the dietary fat level improved FCR and overall protein efficiency retention.
Resumo:
The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation between the distance and the impedance seen by the distance protection relays is not linear and therefore the location is not accurate enough. This paper presents a simple and economical method to identify the subsection between autotransformers and the conductor (catenary or feeder) where the ground fault is happening. This method is based on the comparison of the angle between the current and the voltage of the positive terminal in each autotransformer. Consequently, after the identification of the subsection and the conductor with the ground defect, only the subsection where the ground fault is present will be quickly removed from service, with the minimum effect on rail traffic. This method has been validated through computer simulations and laboratory tests with positive results.
Resumo:
The EPR spectra of spin-labeled lipid chains in fully hydrated bilayer membranes of dimyristoyl phosphatidylcholine containing 40 mol % of cholesterol have been studied in the liquid-ordered phase at a microwave radiation frequency of 94 GHz. At such high field strengths, the spectra should be optimally sensitive to lateral chain ordering that is expected in the formation of in-plane domains. The high-field EPR spectra from random dispersions of the cholesterol-containing membranes display very little axial averaging of the nitroxide g-tensor anisotropy for lipids spin labeled toward the carboxyl end of the sn-2 chain (down to the 8-C atom). For these positions of labeling, anisotropic 14N-hyperfine splittings are resolved in the gzz and gyy regions of the nonaxial EPR spectra. For positions of labeling further down the lipid chain, toward the terminal methyl group, the axial averaging of the spectral features systematically increases and is complete at the 14-C atom position. Concomitantly, the time-averaged 〈Azz〉 element of the 14N-hyperfine tensor decreases, indicating that the axial rotation at the terminal methyl end of the chains arises from correlated torsional motions about the bonds of the chain backbone, the dynamics of which also give rise to a differential line broadening of the 14N-hyperfine manifolds in the gzz region of the spectrum. These results provide an indication of the way in which lateral ordering of lipid chains in membranes is induced by cholesterol.
Resumo:
By equilibrating condensed DNA arrays against reservoirs of known osmotic stress and examining them with several structural probes, it has been possible to achieve a detailed thermodynamic and structural characterization of the change between two distinct regions on the liquid-crystalline phase diagram: (i) a higher density hexagonally packed region with long-range bond orientational order in the plane perpendicular to the average molecular direction and (ii) a lower density cholesteric region with fluid-like positional order. X-ray scattering on highly ordered DNA arrays at high density and with the helical axis oriented parallel to the incoming beam showed a sixfold azimuthal modulation of the first-order diffraction peak that reflects the macroscopic bond-orientational order. Transition to the less-dense cholesteric phase through osmotically controlled swelling shows the loss of this bond orientational order, which had been expected from the change in optical birefringence patterns and which is consistent with a rapid onset of molecular positional disorder. This change in order was previously inferred from intermolecular force measurements and is now confirmed by 31P NMR. Controlled reversible swelling and compaction under osmotic stress, spanning a range of densities between approximately 120 mg/ml to approximately 600 mg/ml, allow measurement of the free-energy changes throughout each phase and at the phase transition, essential information for theories of liquid-crystalline states.
Resumo:
In this paper we introduce the concept of Lateral Trigger Probability (LTP) function, i.e., the probability for an Extensive Air Shower (EAS) to trigger an individual detector of a ground based array as a function of distance to the shower axis, taking into account energy, mass and direction of the primary cosmic ray. We apply this concept to the surface array of the Pierre Auger Observatory consisting of a 1.5 km spaced grid of about 1600 water Cherenkov stations. Using Monte Carlo simulations of ultra-high energy showers the LTP functions are derived for energies in the range between 10(17) and 10(19) eV and zenith angles up to 65 degrees. A parametrization combining a step function with an exponential is found to reproduce them very well in the considered range of energies and zenith angles. The LTP functions can also be obtained from data using events simultaneously observed by the fluorescence and the surface detector of the Pierre Auger Observatory (hybrid events). We validate the Monte Carlo results showing how LTP functions from data are in good agreement with simulations.