A Novel Ground Fault Identification Method for 2 x 5 kV Railway Power Supply Systems


Autoria(s): Serrano, Jesús; Platero Gaona, Carlos Antonio; López-Toledo, Máximo; Granizo Arrabe, Ricardo
Data(s)

13/07/2015

Resumo

The location of ground faults in railway electric lines in 2 × 5 kV railway power supply systems is a difficult task. In both 1 × 25 kV and transmission power systems it is common practice to use distance protection relays to clear ground faults and localize their positions. However, in the particular case of this 2 × 25 kV system, due to the widespread use of autotransformers, the relation between the distance and the impedance seen by the distance protection relays is not linear and therefore the location is not accurate enough. This paper presents a simple and economical method to identify the subsection between autotransformers and the conductor (catenary or feeder) where the ground fault is happening. This method is based on the comparison of the angle between the current and the voltage of the positive terminal in each autotransformer. Consequently, after the identification of the subsection and the conductor with the ground defect, only the subsection where the ground fault is present will be quickly removed from service, with the minimum effect on rail traffic. This method has been validated through computer simulations and laboratory tests with positive results.

Formato

application/pdf

Identificador

http://oa.upm.es/40756/

Idioma(s)

eng

Publicador

E.T.S.I. Industriales (UPM)

Relação

http://oa.upm.es/40756/1/INVE_MEM_2015_220142.pdf

http://www.mdpi.com/1996-1073/8/7/7020

info:eu-repo/semantics/altIdentifier/doi/10.3390/en8077020

Direitos

http://creativecommons.org/licenses/by-nc-nd/3.0/es/

info:eu-repo/semantics/openAccess

Fonte

energies, ISSN 1996-1073, 2015-07-13, Vol. 8, No. 7

Palavras-Chave #Ingeniería Industrial
Tipo

info:eu-repo/semantics/article

Artículo

PeerReviewed