997 resultados para Remote measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Caco-2 cell line has been used as a model to predict the in vitro permeability of the human intestinal barrier. The predictive potential of the assay relies on an appropriate in-house validation of the method. The objective of the present study was to develop a single HPLC-UV method for the identification and quantitation of marker drugs and to determine the suitability of the Caco-2 cell permeability assay. A simple chromatographic method was developed for the simultaneous determination of both passively (propranolol, carbamazepine, acyclovir, and hydrochlorothiazide) and actively transported drugs (vinblastine and verapamil). Separation was achieved on a C18 column with step-gradient elution (acetonitrile and aqueous solution of ammonium acetate, pH 3.0) at a flow rate of 1.0 mL/min and UV detection at 275 nm during the total run time of 35 min. The method was validated and found to be specific, linear, precise, and accurate. This chromatographic system can be readily used on a routine basis and its utilization can be extended to other permeability models. The results obtained in the Caco-2 bi-directional transport experiments confirmed the validity of the assay, given that high and low permeability profiles were identified, and P-glycoprotein functionality was established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous assessment of verticality by means of rod and rod and frame tests indicated that human subjects can be more (field dependent) or less (field independent) influenced by a frame placed around a tilted rod. In the present study we propose a new approach to these tests. The judgment of visual verticality (rod test) was evaluated in 50 young subjects (28 males, ranging in age from 20 to 27 years) by randomly projecting a luminous rod tilted between -18 and +18° (negative values indicating left tilts) onto a tangent screen. In the rod and frame test the rod was displayed within a luminous fixed frame tilted at +18 or -18°. Subjects were instructed to verbally indicate the rod’s inclination direction (forced choice). Visual dependency was estimated by means of a Visual Index calculated from rod and rod and frame test values. Based on this index, volunteers were classified as field dependent, intermediate and field independent. A fourth category was created within the field-independent subjects for whom the amount of correct guesses in the rod and frame test exceeded that of the rod test, thus indicating improved performance when a surrounding frame was present. In conclusion, the combined use of subjective visual vertical and the rod and frame test provides a specific and reliable form of evaluation of verticality in healthy subjects and might be of use to probe changes in brain function after central or peripheral lesions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis the basic structure and operational principals of single- and multi-junction solar cells are considered and discussed. Main properties and characteristics of solar cells are briefly described. Modified equipment for measuring the quantum efficiency for multi-junction solar cell is presented. Results of experimental research single- and multi-junction solar cells are described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart home implementation in residential buildings promises to optimize energy usage and save significant amount of energy simply due to a better understanding of user's energy usage profile. Apart from the energy optimisation prospects of this technology, it also aims to guarantee occupants significant amount of comfort and remote control over home appliances both at home locations and at remote places. However, smart home investment just like any other kind of investment requires an adequate measurement and justification of the economic gains it could proffer before its realization. These economic gains could differ for different occupants due to their inherent behaviours and tendencies. Thus it is pertinent to investigate the various behaviours and tendencies of occupants in different domain of interests and to measure the value of the energy savings accrued by smart home implementations in these domains of interest in order to justify such economic gains. This thesis investigates two domains of interests (the rented apartment and owned apartment) for primarily two behavioural tendencies (Finland and Germany) obtained from observation and corroborated by conducted interviews to measure the payback time and Return on Investment (ROI) of their smart home implementations. Also, similar measures are obtained for identified Australian use case. The research finding reveals that building automation for the Finnish behavioural tendencies seems to proffers a better ROI and payback time for smart home implementations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The power is still today an issue in wearable computing applications. The aim of the present paper is to raise awareness of the power consumption of wearable computing devices in specific scenarios to be able in the future to design energy efficient wireless sensors for context recognition in wearable computing applications. The approach is based on a hardware study. The objective of this paper is to analyze and compare the total power consumption of three representative wearable computing devices in realistic scenarios such as Display, Speaker, Camera and microphone, Transfer by Wi-Fi, Monitoring outdoor physical activity and Pedometer. A scenario based energy model is also developed. The Samsung Galaxy Nexus I9250 smartphone, the Vuzix M100 Smart Glasses and the SimValley Smartwatch AW-420.RX are the three devices representative of their form factors. The power consumption is measured using PowerTutor, an android energy profiler application with logging option and using unknown parameters so it is adjusted with the USB meter. The result shows that the screen size is the main parameter influencing the power consumption. The power consumption for an identical scenario varies depending on the wearable devices meaning that others components, parameters or processes might impact on the power consumption and further study is needed to explain these variations. This paper also shows that different inputs (touchscreen is more efficient than buttons controls) and outputs (speaker sensor is more efficient than display sensor) impact the energy consumption in different way. This paper gives recommendations to reduce the energy consumption in healthcare wearable computing application using the energy model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in Information and Communication Technology (ICT), especially those related to the Internet of Things (IoT), are facilitating smart regions. Among many services that a smart region can offer, remote health monitoring is a typical application of IoT paradigm. It offers the ability to continuously monitor and collect health-related data from a person, and transmit the data to a remote entity (for example, a healthcare service provider) for further processing and knowledge extraction. An IoT-based remote health monitoring system can be beneficial in rural areas belonging to the smart region where people have limited access to regular healthcare services. The same system can be beneficial in urban areas where hospitals can be overcrowded and where it may take substantial time to avail healthcare. However, this system may generate a large amount of data. In order to realize an efficient IoT-based remote health monitoring system, it is imperative to study the network communication needs of such a system; in particular the bandwidth requirements and the volume of generated data. The thesis studies a commercial product for remote health monitoring in Skellefteå, Sweden. Based on the results obtained via the commercial product, the thesis identified the key network-related requirements of a typical remote health monitoring system in terms of real-time event update, bandwidth requirements and data generation. Furthermore, the thesis has proposed an architecture called IReHMo - an IoT-based remote health monitoring architecture. This architecture allows users to incorporate several types of IoT devices to extend the sensing capabilities of the system. Using IReHMo, several IoT communication protocols such as HTTP, MQTT and CoAP has been evaluated and compared against each other. Results showed that CoAP is the most efficient protocol to transmit small size healthcare data to the remote servers. The combination of IReHMo and CoAP significantly reduced the required bandwidth as well as the volume of generated data (up to 56 percent) compared to the commercial product. Finally, the thesis conducted a scalability analysis, to determine the feasibility of deploying the combination of IReHMo and CoAP in large numbers in regions in north Sweden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The value that the customer perceives from a supplier’s offering, impacts customer’s decision making and willingness to pay at the time of the purchase, and the overall satisfaction. Thus, for a business supplier, it is critical to understand their customers’ value perceptions. The objective of this thesis is to understand what measurement and monitoring system customers value, by examining their key purchasing criteria and perceived benefits. Theoretical part of this study consists on reviewing relevant literature on organizational buying behavior and customer perceived value. This study employs a qualitative interview research method. The empirical part of this research consisted of conducting 20 in-depth interviews with life science customers in USA and in Europe. Quality and technical features are the most important purchasing criteria, while product-related benefits seem to be the most important perceived benefits. At the marketing of the system, the emphasis should be at which regulations the system complies with, references of supplier’s prior experience, the reliability and usability of the system, and total costs. The benefits that should be emphasized are the better control of customer’s process, and the proof of customer’s product quality

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, technological advancements in microelectronics and sensor technologies have revolutionized the field of electrical engineering. New manufacturing techniques have enabled a higher level of integration that has combined sensors and electronics into compact and inexpensive systems. Previously, the challenge in measurements was to understand the operation of the electronics and sensors, but this has now changed. Nowadays, the challenge in measurement instrumentation lies in mastering the whole system, not just the electronics. To address this issue, this doctoral dissertation studies whether it would be beneficial to consider a measurement system as a whole from the physical phenomena to the digital recording device, where each piece of the measurement system affects the system performance, rather than as a system consisting of small independent parts such as a sensor or an amplifier that could be designed separately. The objective of this doctoral dissertation is to describe in depth the development of the measurement system taking into account the challenges caused by the electrical and mechanical requirements and the measurement environment. The work is done as an empirical case study in two example applications that are both intended for scientific studies. The cases are a light sensitive biological sensor used in imaging and a gas electron multiplier detector for particle physics. The study showed that in these two cases there were a number of different parts of the measurement system that interacted with each other. Without considering these interactions, the reliability of the measurement may be compromised, which may lead to wrong conclusions about the measurement. For this reason it is beneficial to conceptualize the measurement system as a whole from the physical phenomena to the digital recording device where each piece of the measurement system affects the system performance. The results work as examples of how a measurement system can be successfully constructed to support a study of sensors and electronics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main goal of this master’s thesis was to find out, how to improve customer experience management and measurement. This study is a qualitative case study, in which the data collection method has been interviews. In addition, some of the company’s customer experience measurement methods have been analyzed. The theoretical background is applied in practice by interviewing 5 representatives from the case company. In the case company, the management has launched a customer experience focused program, and given guidelines for customer experience improvement. In the case company, customer experience is measured with different methods, one example is asking the recommendation readiness from a customer. In order to improve the customer experience management, the case company should define, what the company means with customer experience and what kind of customer experience the company is aiming to create. After the encounter, the customer should be left with feelings of satisfaction, positivity and trust. The company should focus on easiness in its processes, on top of which the processes should work fluently. The customer experience management should be improved through systematic planning, and by combining and standardizing different measures. In addition, some channel-based measures should be used. The measurement conducted should be more customer focused, and the case company should form an understanding, which touch points are the most relevant to measure.