119 resultados para microfabrication


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a straightforward method for patterning thin films of polymers, i.e. a prepatterned mask is used to induce self-assembly of polymers and the resulting pattern is the same as the lateral structures in the mask on a submicrometre length scale, The patterns can be formed at above T-g + 30 degreesC in a short time and the external electric field is not crucial. Electrostatic force is assumed to be the driving force for the pattern transfer. Viscous fingering and novel stress-relief lateral morphology induced under the featureless mask are also observed and the formation mechanisms are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new method for the fabrication of an integrated microelectrode for electrochemical detection (ECD) on an electrophoresis microchip is described. The pattern of the microelectrode was directly made on the surface of a microscope slide through an electroless deposition procedure. The surface of the slide was first selectively coated with a thin layer of sodium silicate through a micromolding in capillary technique provided by a poly(dimethylsiloxane) (PDMS) microchannel; this left a rough patterned area for the anchoring of catalytic particles. A metal layer was deposited on the pattern guided by these catalytic particles and was used as the working electrode. Factors influencing the fabrication procedure were discussed. The whole chip was built by reversibly sealing the slide to another PDMS layer with electrophoresis microchannels at room temperature. This approach eliminates the need of clean room facilities and expensive apparatus such as for vacuum deposition or sputtering and makes it possible to produce patterned electrodes suitable for ECD on microchip under ordinary chemistry laboratory conditions. Also once the micropattern is ready, it allows the researchers to rebuild the electrode in a short period of time when an electrode failure occurs. Copper and gold microelectrodes were fabricated by this technique. Glucose, dopamine, and catechol as model analytes were tested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent developments in microfabrication and nanotechnology will enable the inexpensive manufacturing of massive numbers of tiny computing elements with sensors and actuators. New programming paradigms are required for obtaining organized and coherent behavior from the cooperation of large numbers of unreliable processing elements that are interconnected in unknown, irregular, and possibly time-varying ways. Amorphous computing is the study of developing and programming such ultrascale computing environments. This paper presents an approach to programming an amorphous computer by spontaneously organizing an unstructured collection of processing elements into cooperative groups and hierarchies. This paper introduces a structure called an AC Hierarchy, which logically organizes processors into groups at different levels of granularity. The AC hierarchy simplifies programming of an amorphous computer through new language abstractions, facilitates the design of efficient and robust algorithms, and simplifies the analysis of their performance. Several example applications are presented that greatly benefit from the AC hierarchy. This paper introduces three algorithms for constructing multiple levels of the hierarchy from an unstructured collection of processors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of a biofuel cell takes inspiration from the natural capability of biological systems to catalyse the conversion of organic matter with a subsequent release of electrical energy. Enzymatic biofuel cells are intended to mimic the processes occurring in nature in a more controlled and efficient manner. Traditional fuel cells rely on the use of toxic catalysts and are often not easily miniaturizable making them unsuitable as implantable power sources. Biofuel cells however use highly selective protein catalysts and renewable fuels. As energy consumption becomes a global issue, they emerge as important tools for energy generation. The microfluidic platforms developed are intended to maximize the amount of electrical energy extracted from renewable fuels which are naturally abundant in the environment and in biological fluids. Combining microfabrication processes, chemical modification and biological surface patterning these devices are promising candidates for micro-power sources for future life science and electronic applications. This thesis considered four main aspects of a biofuel cell research. Firstly, concept of a miniature compartmentalized enzymatic biofuel cell utilizing simple fuels and operating in static conditions is verified and proves the feasibility of enzyme catalysis in energy conversion processes. Secondly, electrode and microfluidic channel study was performed through theoretical investigations of the flow and catalytic reactions which also improved understanding of the enzyme kinetics in the cell. Next, microfluidic devices were fabricated from cost-effective and disposable polymer materials, using the state-of-the-art micro-processing technologies. Integration of the individual components is difficult and multiple techniques to overcome these problems have been investigated. Electrochemical characterization of gold electrodes modified with Nanoporous Gold Structures is also performed. Finally, two strategies for enzyme patterning and encapsulation are discussed. Several protein catalysts have been effectively immobilized on the surface of commercial and microfabricated electrodes by electrochemically assisted deposition in sol-gel and poly-(o-phenylenediamine) polymer matrices and characterised with confirmed catalytic activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a model as well as experimental results for a surface electrode radiofrequency Paul trap that has a circular electrode geometry well suited for trapping single ions and two-dimensional planar ion crystals. The trap design is compatible with microfabrication and offers a simple method by which the height of the trapped ions above the surface may be changed in situ. We demonstrate trapping of single Sr88+ ions over an ion height range of 200-1000 μm for several hours under Doppler laser cooling and use these to characterize the trap, finding good agreement with our model. © 2010 The American Physical Society.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The switching thresholds of magnetophoretic transistors for sorting cells in microfluidic environments are characterized. The transistor operating conditions require short 20-30 mA pulses of electrical current. By demonstrating both attractive and repulsive transistor modes, a single transistor architecture is used to implement the full write cycle for importing and exporting single cells in specified array sites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of precision grinding for the formation of a silicon diaphragm is investigated. The test structures involved 2-6 mm diam diaphragms with thicknesses in the range of 25-150 //m. When grinding is performed without supporting the diaphragm, bending occurs due to nonuniform removal of the silicon material over the diaphragm region. The magnitude of bending depends on the µNal thickness of the diaphragm. The results demonstrate that the use of a porous silicon support can significantly reduce the amount of bending, by a factor of up to 300 in the case of 50 m thick diaphragms. The use of silicon on insulator (SOI) technology can also suppress or eliminate bending although this may be a less economical process. Stress measurements in the diaphragms were performed using x-ray and Raman spectroscopies. The results show stress of the order of 1 X107-! X108 Pa in unsupported and supported by porous silicon diaphragms while SOI technology provides stress-free diaphragms. Results obtained from finite element method analysis to determine deterioration in the performance of a 6 mm diaphragm due to bending are presented. These results show a 10% reduction in performance for a 75 µm thick diaphragm with bending amplitude of 30 fim, but negligible reduction if the bending is reduced to

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transdermal drug delivery offers a number of advantages for the patient, due not only its non-invasive and convenient nature, but also factors such as avoidance of first pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedle arrays can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below. Microneedles have been extensively investigated in recent decades for drug and vaccine delivery as well as minimally invasive patient monitoring/diagnosis. This review focuses on a range of critically important aspects of microneedle technology, namely their material composition, manufacturing techniques, methods of evaluation and commercial translation to the clinic for patient benefit and economic return. Microneedle research and development is finally now at the stage where commercialisation is a realistic possibility. However, progress is still required in the areas of scaled-up manufacture and regulatory approval.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The incidence of cardiovascular diseases (CVD) has been increasing according to the European and global statistics. Thus, the development of new analytical devices, such as biosensors for assessing the risk of CVD could become a valuable approach for the improvement of healthcare service. In latest years, the nanotechnology has provided new materials with improved electronic properties which have an important contribution in the transduction mechanism of biosensors. Thus, in this thesis, biosensors based on field effect transistors with single-walled carbon nanotubes (NTFET) were developed for the detection of C-reactive protein (CRP) in clinical samples, that is, blood serum and saliva from a group of control patients and a group of CVD risk patients. CRP is an acute-phase protein, which is commonly known as the best validated biomarker for the assessment of CVD, the single-walled carbon nanotubes (SWCNT) were applied as transduction components, and the immunoreaction (interaction between the CRP antigen and the antibodies specific to CRP) was used as the mechanism of molecular recognition for the label-free detection of CRP. After the microfabrication of field effect transistors (FET), the screening of the most important variables for the dispersion of SWCNT, the assemblage of NTFET, and their application on standard solutions of CRP, it was found that NTFET respond accurately to CRP both in saliva and in serum samples, since similar CRP levels were found with the NTFET and the traditional methodology (ELISA technique). On the other hand, a strong correlation between salivary and serum CRP was found with NTFET, which means that saliva could be used, based on non-invasive sampling, as an alternative fluid to blood serum. It was also shown that NTFET could discriminate control patients from CVD risk patients, allowing the determination of a cut-off value for salivary CRP of 1900 ng L-1, which corresponds to the well established cut-off of 3 mg L-1 for CRP in serum, constituting an important finding for the possible establishment of a new range of CRP levels based on saliva. According to the data provided from the volunteer patients regarding their lipoprotein profile and lifestyle factors, it was concluded that the control and the CVD risk patients could be separated taking into account the various risk factors established in literature as strong contributors for developing a CVD, such as triglycerides, serum CRP, total cholesterol, LDL cholesterol, body mass index, Framingham risk score, hypertension, dyslipidemia, and diabetes mellitus. Thus, this work could provide an additional contribution to the understanding of the association of biomarkers levels in serum and saliva samples, and above all, cost-effective, rapid, label-free, and disposable NTFET were developed, based on a noninvasive sampling, for the assessment of CVD risk, thus constituting a potential point-of-care technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Màster en Nanociència i Nanotecnologia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electrochemical sensors are increasingly being investigated to perform measurements for single or multiple analytes. Demanded by modern medical diagnosis, advances in microfabrication technology have led to the development of fast, sensitive and selective electrochemical sensors for drug analysis. Electrochemical sensors for the measurement of analytes of interest in clinical chemistry are ideally suited for these applications, due to their high sensitivity and selectivity, simple-to-operate, rapid response time and low-cost. As part of the present investigations eight voltammetric sensors have been fabricated for six drugs such as PAM Chloride, Tamsulosin Hydrochloride, Hesperidin Methyl Chalcone, Guaiphenesin, Cephalexin and Amoxicillin trihydrate. The modification techniques adopted as part of the present work include multiwalled carbon nanotube (MWNT) based modifications, electropolymerization, gold nanoparticle (AuNP) based modifications and platinum nanoparticle (PtNP) based modifications. The thesis is divided into nine chapters