1000 resultados para Garrett MS 140


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A selective method using three-phase liquid-phase microextraction (LPME) in conjunction with LC-MS-MS was devised for the enantioselective determination of chloroquine and its n-dealkylated metabolites in plasma samples. After alkalinization of the samples, the analytes were extracted into n-octanol immobilized in the pores of a polypropylene hollow fiber membrane and back extracted into the acidic acceptor phase (0.1 M TFA) filled into the lumen of the hollow fiber. Following LPME, the analytes were resolved on a Chirobiotic V column using methanol/ACN/glacial aceti acid/diethylamine (90:10:0.5:0.5 by volume) as the mobile phase. The MS detection was carried out using multiple reaction monitoring with ESI in the positive ion mode. The optimized LPME method yielded extraction recoveries ranging from 28 to 66%. The method was linear over 5 - 500 ng/mL and precision (RSD) and accuracy (relative error) values were below 15% for all analytes. The developed method was applied to the determination of the analytes in rat plasma samples after oral administration of the racemic drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lychnophora ericoides Mart. (Asteraceae, Vernonieae) is a plant, endemic to Brazil, with occurrence restricted to the ""cerrado"" biome. Traditional medicine employs alcoholic and aqueous-alcoholic preparations of leaves from this species for the treatment of wounds, inflammation, and pain. Furthermore, leaves of L. ericoides are also widely used as flavorings for the Brazilian traditional spirit ""cachaca"". A method has been developed for the extraction and HPLC-DAD analysis of the secondary metabolites of L. ericoides leaves. This analytical method was validated with 11 secondary metabolites chosen to represent the different classes and polarities of secondary metabolites occurring in L. ericoides leaves, and good responses were obtained for each validation parameter analyzed. The same HPLC analytical method was also employed for online secondary metabolite identification by HPLC-DAD-MS and HPLC-DAD-MS/MS, leading to the identification of di-C-glucosylflavones, coumaroylglucosylflavonols, flavone, flavanones, flavonols, chalcones, goyazensolide, and eremantholide-type sesquiterpene lactones and positional isomeric series of chlorogenic acids possessing caffeic and/or ferulic moieties. Among the 52 chromatographic peaks observed, 36 were fully identified and 8 were attributed to compounds belonging to series of caffeoylferuloylquinic and diferuloylquinic acids that could not be individualized from each other.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was the development and validation of an LC-MS-MS method for simultaneous analysis of ibuprofen (IBP), 2-hydroxyibuprofen (2-OH-IBP) enantiomers, and carboxyibuprofen (COOH-IBP) stereoisomers in fungi culture medium, to investigate the ability of some endophytic fungi to biotransform the chiral drug IBP into its metabolites. Resolution of IBP and the stereoisomers of its main metabolites was achieved by use of a Chiralpak AS-H column (150 x 4.6 mm, 5 mu m particle size), column temperature 8 degrees C, and the mobile phase hexane-isopropanol-trifluoroacetic acid (95: 5: 0.1, v/v) at a flow rate of 1.2 mL min(-1). Post-column infusion with 10 mmol L(-1) ammonium acetate in methanol at a flow rate of 0.3 mL min(-1) was performed to enhance MS detection (positive electrospray ionization). Liquid-liquid extraction was used for sample preparation with hexane-ethyl acetate (1:1, v/v) as extraction solvent. Linearity was obtained in the range 0.1-20 mu g mL(-1) for IBP, 0.05-7.5 mu g mL(-1) for each 2-OH-IBP enantiomer, and 0.025-5.0 mu g mL(-1) for each COOH-IBP stereoisomer (r >= 0.99). The coefficients of variation and relative errors obtained in precision and accuracy studies (within-day and between-day) were below 15%. The stability studies showed that the samples were stable (p > 0.05) during freeze and thaw cycles, short-term exposure to room temperature, storage at -20 degrees C, and biotransformation conditions. Among the six fungi studied, only the strains Nigrospora sphaerica (SS67) and Chaetomium globosum (VR10) biotransformed IBP enantioselectively, with greater formation of the metabolite (+)-(S)-2-OH-IBP. Formation of the COOH-IBP stereoisomers, which involves hydroxylation at C3 and further oxidation to form the carboxyl group, was not observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flavone C-glucoside, vicenin-2, in semi-purified extracts of the leaves of Lychnophora ericoides was quantified in rat plasma samples using a method based on reversed-phase high performance liquid chromatography coupled to tandem mass spectrometry. Vicenin-2 was analyzed on a LiChrospher (R) RP18 column using an isocratic mobile phase consisting of a mixture of methanol: water (30:70, v/v) plus 2.0% glacial acetic acid at a flow rate of 0.8 mL min(-1). Genistein was used as internal standard. The mass spectrometer was operated in positive ionization mode and analytes were quantified by multiple reaction monitoring at m/z 595 > 457 for vicenin-2 and m/z 271 > 153 for internal standard. Prior to the analysis, each rat plasma sample was acidified with 200 mu L of 50 mmol L(-1) acetic acid solution and extracted by solid-phase extraction using a C18 cartridge. The absolute recoveries were reproducible and the coefficients of variation values were lower than 5.2%. The method was linear over the 12.5 - 1500 ng mL(-1) concentration range and the quantification limit was 12.5 ng mL(-1). Within-day and between-day assay precision and accuracy were studied at three concentration levels (40, 400 and 800 ng mL(-1)) and were lower than 15%. The developed and validated method seems to be suitable for analysis of vicenin-2 in plasma samples obtained from rats that receive a single i.p. dose of 200 mg kg(-1) vicenin-2 extract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The beta-carbolines 1-methyl-9H-pyrido [3,4-b]indole and 9H-pyrido[3,4b]indole have been implicated as having causative roles in a number of human diseases, such as Parkinson`s disease and cancer. As they can be formed during the heating of protein-rich food, a number of analytical methodologies have been proposed for their detection and quantification in foodstuff For this purpose, LC-MS and LC-MS/MS have emerged as the most specific analytical methods, and the quantification is based on the occurrence of unusual ions, such as [M+H-(H(center dot))](+) and [M + H-2H](+). In this study, we have investigated the formation of these ions by accurate-mass electrospray MS/MS and demonstrated that these ions are formed from gas-phase ion-molecule reactions between water vapor present in the collision cell and the protonated molecule of 1-methyl-9H-pyrido [3,4-b]indole and 9H-pyrido[3,4b]indole. Although this reaction has been previously described for heterocyclic amine ions, it has been overlooked in the most of recent LC-MS and LC-MS/MS studies, and no complete data of the fragmentation are reported. Our results demonstrate that additional attention should be given with respect to eliminating water vapor residues in the mass spectrometer when analysis of beta-carbolines is performed, as this residue may affect the reliability in the results of quantification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple enantioselective method for the determination of praziquantel (PZQ) and trans-4-hydroxypraziquantel (4-OHPZQ) in human plasma was developed and validated by high-performance liquid chromatography/mass spectrometry. The plasma samples were prepared by liquid-liquid extraction using a mixture of methyl-tert-butylether/dichloromethane (2:1, v/v) as extraction solvent. The direct resolution of PZQ and 4-OHPZQ enantiomers was performed on a Chiralpak AD column using hexane-isopropanol (75:25, v/v) as the mobile phase. Diazepam was used as internal standard. The method described here is simple and reproducible. The quantitation limit of 1.25 ng/ml for each PZQ enantiomer and of 12.5 ng/ml for each 4-OHPZQ enantiomer permits the use of the method in studies investigating the kinetic disposition of a single dose of 1.5g racemic PZQ. Enantioselectivity in the kinetic disposition of PZQ and 4-OHPZQ was observed in the clinical study. with the demonstration of a higher proportion of the (+)-(S)-PZQ and (-)-(R)-4-OHPZQ enantiomers in plasma. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an analytical method for the rapid screening and identification of the phenolic constituents present in the polar extracts of different Lychnophora spp. using LC-UV/DAD-ESI-MS and LC-UV/DAD-ESI-MS/MS. Compounds were identified based on UV, retention time, MS experiments and MS/MS of precursor ion or standard. On-line phytochemical investigation of Lychnophora spp. allowed for the identification of flavonoids, chlorogenic acid derivatives and lactones. Some of the observed compounds were for the first time identified in Lychnophora species in a fast analytical procedure. The data obtained here may be helpful to the investigation of polar constituents from other Lychnophora species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new and promising nitrosyl ruthenium complex, [Ru(NO)(bdqi-COOH)(terpy)](PF(6))(3), bdqi-COOH is 3,4-diiminebenzoic acid and terpy is 2,2`-terpyridine, has been synthesized as a NO donor agent. The procedure used for [Ru(NO)(bdqi-COOH)(terpy)](PF(6))(3) synthesis has, apparently, yielded the formation of two isomers in which the ligand bdqi-COOH appears to be coordinated in its reduced form (bdcat-COOH), which could have differences in their pharmacological properties. Therefore, it was intended to separate the two possible isomers by high-performance liquid chromatography (HPLC) and to characterize them by high resolution mass spectrometry (QTOF MS) and by magnetic nuclear resonance spectroscopy (NMR). The results obtained by MS showed that the ESI-MS mass spectra of both HPLC column fractions, e.g. peak 1 and peak 2, are essentially equal, showing that both isomers display nearly identical gas-phase behavior with clusters of isotopologue ions centered at m/z 573, m/z 543 and m/z 513. Regarding the NMR analysis, the results showed that the positional isomerism is located in the bdqi-COOH ligand. From the observed results it can be concluded that the synthesis procedure that has been used results in the formation of two [Ru(terpy)(bdqi-COOH)NO](PF(6))(3) isomers. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The trace element selenium (Se), once known only for its potential toxicity, is now a well-established essential micronutrient for mammals. The organoselenium compound diphenyl diselenide (DPDS) has shown interesting antioxidant and neuroprotective activities. On the other hand, this compound has also presented pro-oxidant and mutagenic effects. The compound 3`3-ditrifluoromethyldiphenyl diselenide (DFDD), a structural analog of diphenyl diselenide, has proven antipsychotic activity in mice. Nevertheless, as opposed to DPDS, little is known on the biological and toxicological properties of DFDD. In the present study, we report the genotoxic effects of the organoselenium compound DFDD on Salmonella typhimurium, Saccharomyces cerevisiae and Chinese hamster lung fibroblasts (V79 cells). DFDD protective effects against hydrogen peroxide (H(2)O(2))-induced DNA damage in vitro are demonstrated. DFDD did not cause mutagenic effects on S. typhimurium or S. cerevisiae strains; however, it induced DNA damage in V79 cells at doses higher than 25 mu M, as detected by comet assay. DFDD protected S. typhimurium and S. cerevisiae against H(2)O(2)-induced mutagenicity, and, at doses lower than 12.5 mu M, prevented H(2)O(2)-induced genotoxicity in V79 cells. The in vitro assays demonstrated that DFDD mimics catalase activity better than DPDS, but neither presents Superoxide dismutase action. The products of the reactions of DFDD or DPDS with H(2)O(2) were different. as determined by electrospray mass spectrometry analysis (ESI-MS). These results suggest that DFDD is not mutagenic for bacteria or yeast; however, it may induce weak genotoxic effects on mammalian cells. In addition, DFDD has a protective effect against H(2)O(2)-induced damage probably by mimicking catalase activity, and the distinct products of the reaction DFDD with H(2)O(2) probably have a fundamental role in the protective effects of DFDD. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Palladium plus magnesium nitrates with and without Ir, Ru and W were evaluated for the simultaneous determination of As, Cu and Pb in cachaca by graphite furnace atomic absorption spectrometry. For 20 mu L sample, 5 mu L Pd(NO(3))(2) and 3 mu L Mg(NO(3))(2) dispensed together onto the Ir-coated platform of the THGA, analytical curves in the 0-30.0 mu g L(-1) As, 0-1.50 mg L(-1) Cu and 0-60.0 mu g L(-1) Pb were built up and typical linear correlation coefficients were always better than 0.999. The limit of detection was 1.30 mu g L(-1) As, 140 mu g L(-1) Cu and 0.90 mu g L(-1) Pb. As, Cu and Pb contents in 10 cachaca samples agreed with those obtained by ICP-MS. Recoveries of spiked samples varied from 96% to 106% (As), 97% to 112% (Cu) and 92% to 108% (Pb). The relative standard deviation (n = 12) was typically 2.7%, 3.3% and 1.9%. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CVICP-MS). Aliquots of whole blood (500 mL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by online addition of L-cysteine and then reduced to elemental Hg by SnCl(2). On the other hand, total mercury was determined by on-line addition of KMnO(4) and then reduced to elemental Hg by NaBH(4). Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 mu g L(-1) and 0.08 mu g L(-1) for inorganic and total mercury, respectively. Sample throughput is 20 samples h(-1). The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study used for the first time LC-MS/MS for the analysis of mitragynine (MIT), a mu-opioid agonist with antinociceptive and antitussive properties, in rat plasma. Mitragynine and the internal standard (amitriptyline) were extracted from plasma with hexane-isoamyl alcohol and resolved on a Lichrospher (R) RP-SelectB column (9.80 and 12.90 min, respectively). The quantification limit was 0.2 ng/mL within a linear range of 0.2-1000 ng/mL The method was applied to quantify mitragynine in plasma samples of rats (n = 8 per sampling time) treated with a single oral dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration: 424 ng/mL; time to reach maximum plasma concentration: 1.26 h; elimination half-life: 3.85 h, apparent total clearance: 6.35 L/h/kg, and apparent volume of distribution: 37.90 L/kg. (C) 2009 Elsevier B.V. All rights reserved.