986 resultados para Thickness measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

High mechanical stress in atherosclerotic plaques at vulnerable sites, called critical stress, contributes to plaque rupture. The site of minimum fibrous cap (FC) thickness (FCMIN) and plaque shoulder are well-documented vulnerable sites. The inherent weakness of the FC material at the thinnest point increases the stress, making it vulnerable, and it is the big curvature of the lumen contour over FC which may result in increased plaque stress. We aimed to assess critical stresses at FCMIN and the maximum lumen curvature over FC (LCMAX) and quantify the difference to see which vulnerable site had the highest critical stress and was, therefore, at highest risk of rupture. One hundred patients underwent high resolution carotid magnetic resonance (MR) imaging. We used 352 MR slices with delineated atherosclerotic components for the simulation study. Stresses at all the integral nodes along the lumen surface were calculated using the finite-element method. FCMIN and LCMAX were identified, and critical stresses at these sites were assessed and compared. Critical stress at FC MIN was significantly lower than that at LCMAX (median: 121.55 kPa; inter quartile range (IQR) = [60.70-180.32] kPa vs. 150.80 kPa; IQR = [91.39-235.75] kPa, p < 0.0001). If critical stress at FCMIN was only used, then the stress condition of 238 of 352 MR slices would be underestimated, while if the critical stress at LCMAX only was used, then 112 out of 352 would be underestimated. Stress analysis at FCMIN and LCMAX should be used for a refined mechanical risk assessment of atherosclerotic plaques, since material failure at either site may result in rupture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial mechanical property may be a potential variable for risk stratification. Large artery and central arterial compliance have been shown not only to correlate well with overall cardiovascular outcome in large epidemiological studies [1, 2] but also to correlate with coronary atherosclerotic burden as measured by conventional angiography [3]. Until recently, real-time B-mode ultrasound combined with simultaneous blood pressure measurements have been used to assess large artery compliance [4]. These techniques have an excellent temporal resolution but are unable to provide adequate spatial resolution to determine changes in vessel area as opposed to diameter and make the assumption that the vessel is perfectly round. Attempts to use MR imaging to measure large artery compliance have been published previously [5]. However, they have not utilised simultaneous blood pressure measurements during sequence acquisition. We report a technique using regular and simultaneous blood pressure measurement during 2 dimensional phase contrast magnetic resonance imaging 2DPC-MRI to determine local carotid compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eleven carotid atherothrombotic plaque samples were harvested from patients. Three samples that were highly calcified were discarded, while eight yielded results. The elastic properties of the material were estimated by fitting the measured indentation response to finite element simulations. The methodology was refined and its accuracy quantified using a synthetic rubber. The neo-Hookean form of the material model gave a good fit to the measured response of the tissue. The inferred shear modulus μ was found to be in the range 7-100 kPa, with a median value of 11 kPa. A review of published materials data showed a wide range of material properties for human atherothrombotic tissue. The effects of anisotropy and time dependency in these published results were highlighted. The present measurements were comparable to the static radial compression tests of Lee et al, 1991 [Structure-dependent dynamic behaviour of fibrous caps from human atherosclerotic plaques. Circulation 83, 1764-1770].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial compliance has been shown to correlate well with overall cardiovascular outcome and it may also be a potential risk factor for the development of atheromatous disease. This study assesses the utility of 2-D phase contrast Magnetic Resonance (MR) imaging with intra-sequence blood pressure measurement to determine carotid compliance and distensibility. 20 patients underwent 2-D phase contrast MR imaging and also ultrasound-based wall tracking measurements. Values for carotid compliance and distensibility were derived from the two different modalities and compared. Linear regression analysis was utilised to determine the extent of correlation between MR and ultrasound derived parameters. In those variables that could be directly compared, an agreement analysis was undertaken. MR measures of compliance showed a good correlation with measures based on ultrasound wall-tracking (r=0.61, 95% CI 0.34 to 0.81 p=0.0003). Vessels that had undergone carotid endarterectomy previously were significantly less compliant than either diseased or normal contralateral vessels (p=0.04). Agreement studies showed a relatively poor intra-class correlation coefficient (ICC) between diameter-based measures of compliance through either MR or ultrasound (ICC=0.14). MRI based assessment of local carotid compliance appears to be both robust and technically feasible in most subjects. Measures of compliance correlate well with ultrasound-based values and correlate best when cross-sectional area change is used rather than derived diameter changes. If validated by further larger studies, 2-D phase contrast imaging with intra-sequence blood pressure monitoring and off-line radial artery tonometry may provide a useful tool in further assessment of patients with carotid atheroma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report an in vivo human examination of carotid atheroma by using the inversion-recovery ON resonance (IRON) sequence, which is able to produce positive contrast after the infusion of an ultrasmall super paramagnetic iron oxide (USPIO) contrast medium. This technique provides a method of potentially identifying inflammatory burden within carotid atheroma. This may be particularly useful in patients who currently do not meet criteria for intervention (ie, moderate symptomatic stenosis or <70% asymptomatic stenosis) to further risk-stratify this important patient cohort. A 63-year-old man was imaged at 1.5 T before and 36 hours after USPIO infusion by using the IRON sequence. Regions of interest showing profound signal loss at T2*-weighted imaging corresponded well with regions of positive contrast at IRON imaging after the administration of USPIO. These regions also showed a profound decrease in T2* measurements after USPIO infusion, whereas surrounding tissue did not. It has been shown that such strong signal loss on T2*-weighted images after USPIO infusion is indicative of USPIO uptake.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose Acute cerebral ischemic events are associated with rupture of vulnerable carotid atheroma and subsequent thrombosis. Factors such as luminal stenosis and fibrous cap thickness have been thought to be important risk factors for plaque rupture. We used a flow-structure interaction model to simulate the interaction between blood flow and atheromatous plaque to evaluate the effect of the degree of luminal stenosis and fibrous cap thickness on plaque vulnerability. Methods A coupled nonlinear time-dependent model with a flow-plaque interaction simulation was used to perform flow and stress/strain analysis in a stenotic carotid artery model. The stress distribution within the plaque and the flow conditions within the vessel were calculated for every case when varying the fibrous cap thickness from 0.1 to 2 mm and the degree of luminal stenosis from 10% to 95%. A rupture stress of 300 kPa was chosen to indicate a high risk of plaque rupture. A 1-sample t test was used to compare plaque stresses with the rupture stress. Results High stress concentrations were found in the plaques in arteries with >70% degree of stenosis. Plaque stresses in arteries with 30% to 70% stenosis increased exponentially as fibrous cap thickness decreased. A decrease of fibrous cap thickness from 0.4 to 0.2 mm resulted in an increase of plaque stress from 141 to 409 kPa in a 40% degree stenotic artery. Conclusions There is an increase in plaque stress in arteries with a thin fibrous cap. The presence of a moderate carotid stenosis (30% to 70%) with a thin fibrous cap indicates a high risk for plaque rupture. Patients in the future may be risk stratified by measuring both fibrous cap thickness and luminal stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An inexpensive and simple circuit to aid the direct measurement of majority carrier capture cross sections of impurity levels in the band gap of a semiconductor by the variable width filling pulse technique is presented. With proper synchronisation, during the period of application of the pulse, the device is disconnected from the capacitance meter to avoid distortion of the pulse and is reconnected again to the meter to record the emission transient. Modes of operation include manual triggering for long emission transients, repetitive triggering for isothermal and DLTS measurements and the DLTS mode which is to be used with signal analysers that already provide a synchronising pulse for disconnection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The minimum cost classifier when general cost functionsare associated with the tasks of feature measurement and classification is formulated as a decision graph which does not reject class labels at intermediate stages. Noting its complexities, a heuristic procedure to simplify this scheme to a binary decision tree is presented. The optimizationof the binary tree in this context is carried out using ynamicprogramming. This technique is applied to the voiced-unvoiced-silence classification in speech processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the design and characterization of a circuit technique to measure the on-chip delay of an individual logic gate (both inverting and noninverting) in its unmodified form. The test circuit comprises of digitally reconfigurable ring oscillator (RO). The gate under test is embedded in each stage of the ring oscillator. A system of linear equations is then formed with different configuration settings of the RO, relating the individual gate delay to the measured period of the RO, whose solution gives the delay of the individual gates. Experimental results from a test chip in 65-nm process node show the feasibility of measuring the delay of an individual inverter to within 1 ps accuracy. Delay measurements of different nominally identicall inverters in close physical proximity show variations of up to 28% indicating the large impact of local variations. As a demonstration of this technique, we have studied delay variation with poly-pitch, length of diffusion (LOD) and different orientations of layout in silicon. The proposed technique is quite suitable for early process characterization, monitoring mature process in manufacturing and correlating model-to-hardware.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A modified DLTS technique is proposed for the direct measurement of capture cross-section of MOS surface states. The nature of temperature and energy dependence σn is inferred from data analysis. Temperature dependence of σn is shown to be consistent with the observed DLTS line shapes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we assessed a broad range of barley breeding lines and commercial varieties by three hardness methods (two particle size methods and one crush resistance method (SKCS—Single-Kernel Characterization System), grown at multiple sites to see if there was variation in barley hardness and if that variation was genetic or environmentally controlled. We also developed near-infrared reflectance (NIR) calibrations for these three hardness methods to ascertain if NIR technology was suitable for rapid screening of breeding lines or specific populations. In addition, we used this data to identify genetic regions that may be associated with hardness. There were significant (p<0.05) genetic effects for the three hardness methods. There were also environmental effects, possibly linked to the effect of protein on hardness, i.e. increasing protein resulted in harder grain. Heritability values were calculated at >85% for all methods. The NIR calibrations, with R2 values of >90%, had Standard Error of Prediction values of 0.90, 72 and 4.0, respectively, for the three hardness methods. These equations were used to predict hardness values of a mapping population which resulted in genetic markers being identified on all chromosomes but chromosomes 2H, 3H, 5H, 6H and 7H had markers with significant LOD scores. The two regions on 5H were on the distal end of both the long and short arms. The region that showed significant LOD score was on the long arm. However, the region on the short arm associated with the hardness (hordoindoline) genes did not have significant LOD scores. The results indicate that barley hardness is influenced by both genotype and environment and that the trait is heritable, which would allow breeders to develop very hard or soft varieties if required. In addition, NIR was shown to be a reliable tool for screening for hardness. While the data set used in this study has a relatively low variation in hardness, the tools developed could be applied to breeding populations that have large variation in barley grain hardness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

his paper describes an improved microtiter solid-phase enzyme immunoassay for the determination of total and allergen-specific human IgE. This assay technique is unique in its use of the avidin-biotin interaction to increase sensitivity. The avidin-biotin microtiter enzyme-linked immunosorbant assay (AB-microELISA) was performed in polyvinyl chloride microtiter plates using biotinylated anti-IgE and horseradish peroxidase (HRP)-avidin conjugate. This AB-microELISA technique enabled the quantitation of human serum IgE in the range of 0.1–5 ng/ml (10–500 pg/test) in less than 3 h. Total serum IgE, whether measured by the AB-microELISA or the paper radioimmunosorbant test (PRIST) was similar (correlation coefficient, r = 0.92). Further, the presence or absence of positive skin tests to 7 specific allergens determined in serum donors generally agreed with the presence or absence of allergen-specific IgE in their sera as measured by the AB-microELISA. The quantity of short ragweed allergen-specific IgE as determined by the AB-microELISA agreed with values obtained by the radioimmunosorbant test (RAST) (correlation coefficient, r = 0.89). No significant interference by ragweed-specific IgG (blocking antibody) was observed in the quantitation of allergen-specific IgE. The AB-microELISA is not only rapid and inexpensive, but also more sensitive than other published ELISA procedures and comparable to solid-phase radioimmunoassays in the quantitation of total and allergen-specific IgE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Replicable experimental studies using a novel experimental facility and a machine-based odour quantification technique were conducted to demonstrate the relationship between odour emission rates and pond loading rates. The odour quantification technique consisted of an electronic nose, AromaScan A32S, and an artificial neural network. Odour concentrations determined by olfactometry were used along with the AromaScan responses to train the artificial neural network. The trained network was able to predict the odour emission rates for the test data with a correlation coefficient of 0.98. Time averaged odour emission rates predicted by the machine-based odour quantification technique, were strongly correlated with volatile solids loading rate, demonstrating the increased magnitude of emissions from a heavily loaded effluent pond. However, it was not possible to obtain the same relationship between volatile solids loading rates and odour emission rates from the individual data. It is concluded that taking a limited number of odour samples over a short period is unlikely to provide a representative rate of odour emissions from an effluent pond. A continuous odour monitoring instrument will be required for that more demanding task.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.