Interfacial area measurement in a gas - liquid ejector for a sodium chloride - air system
Data(s) |
01/05/2009
|
---|---|
Resumo |
Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system. |
Formato |
application/pdf |
Identificador |
http://eprints.iisc.ernet.in/21124/1/IJCT_16%283%29_278-282.pdf Raghuram, PT (2009) Interfacial area measurement in a gas - liquid ejector for a sodium chloride - air system. In: Indian Journal of Chemicla Technology, 16 (3). pp. 278-282. |
Publicador |
National Institute of Science Communication and Information Resources |
Relação |
http://www.niscair.res.in/ScienceCommunication/ResearchJournals/rejour/ijct/ijct2k9/ijct_may09.asp#278 http://eprints.iisc.ernet.in/21124/ |
Palavras-Chave | #Chemical Engineering |
Tipo |
Journal Article PeerReviewed |