923 resultados para DC Distribution System
Resumo:
A simple method is presented to evaluate the effects of short-range correlations on the momentum distribution of nucleons in nuclear matter within the framework of the Greens function approach. The method provides a very efficient representation of the single-particle Greens function for a correlated system. The reliability of this method is established by comparing its results to those obtained in more elaborate calculations. The sensitivity of the momentum distribution on the nucleon-nucleon interaction and the nuclear density is studied. The momentum distributions of nucleons in finite nuclei are derived from those in nuclear matter using a local-density approximation. These results are compared to those obtained directly for light nuclei like 16O.
Resumo:
Motivation for the present study is to improve the scienti c understanding on the prominent gap areas in the average three-dimensional distribution of clouds and their impact on the energetics of the earth-atmosphere system. This study is focused on the Indian subcontinent and the surrounding oceans bound within the latitude-longitude bands of 30 S to 30 N and 30 E to 110 E. Main objectives of this study are to : (i) estimate the monthly and seasonal mean vertical distributions of clouds and their spatial variations (which provide the monthly and seasonal mean 3-dimensional distributions of clouds) using multi-year satellite data and investigate their association with the general circulation of the atmosphere, (ii) investigate the characteristics of the `pool of inhibited cloudiness' that appear over the southwest Bay of Bengal during the Asian summer monsoon season (revealed by the 3-dimensional distribution of clouds) and identify the potential mechanisms for its genesis, (iii) investigate the role of SST and atmospheric thermo-dynamical parameters in regulating the vertical development and distribution of clouds, (iv) investigate the vertical distribution of tropical cirrus clouds and their descending nature using lidar observations at Thiruvananthapuram (8.5 N, 77 E), a tropical coastal station at the southwest Peninsular India, and (v) assessment of the impact of clouds on the energetics of the earth-atmosphere system, by estimating the regional seasonal mean cloud radiative forcing at top-of-the-atmosphere (TOA) and latent heating of the atmosphere by precipitating clouds using satellite data
Resumo:
Short term load forecasting is one of the key inputs to optimize the management of power system. Almost 60-65% of revenue expenditure of a distribution company is against power purchase. Cost of power depends on source of power. Hence any optimization strategy involves optimization in scheduling power from various sources. As the scheduling involves many technical and commercial considerations and constraints, the efficiency in scheduling depends on the accuracy of load forecast. Load forecasting is a topic much visited in research world and a number of papers using different techniques are already presented. The accuracy of forecast for the purpose of merit order dispatch decisions depends on the extent of the permissible variation in generation limits. For a system with low load factor, the peak and the off peak trough are prominent and the forecast should be able to identify these points to more accuracy rather than minimizing the error in the energy content. In this paper an attempt is made to apply Artificial Neural Network (ANN) with supervised learning based approach to make short term load forecasting for a power system with comparatively low load factor. Such power systems are usual in tropical areas with concentrated rainy season for a considerable period of the year
Resumo:
This study gave the first report on the biennial metal divergence in the sediments of Cochin Estuarine system (CES). Surface sediments from 6 prominent regions of CES were sampled in 2009 and 2011 for the geochemical and environmental assessment of trace metals (Cd, Co, Cr, Cu, Pb Fe, Mg, Mn, Ni and Zn).Besides texture, total organic carbon (TOC) and CHNS were also done. The contamination and risk assessment were performed by determining geochemical indices. Comparison with sediment quality guidelines were done to assess the probability for ecotoxicological threat to the estuary. Results showed that the measured heavy metals had varied spatial distribution patterns, indicating that they had complex origins and controlling factors
Resumo:
Salient pole brushless alternators coupled to IC engines are extensively used as stand-by power supply units for meeting in- dustrial power demands. Design of such generators demands high power to weight ratio, high e ciency and low cost per KVA out- put. Moreover, the performance characteristics of such machines like voltage regulation and short circuit ratio (SCR) are critical when these machines are put into parallel operation and alterna- tors for critical applications like defence and aerospace demand very low harmonic content in the output voltage. While designing such alternators, accurate prediction of machine characteristics, including total harmonic distortion (THD) is essential to mini- mize development cost and time. Total harmonic distortion in the output voltage of alternators should be as low as possible especially when powering very sophis- ticated and critical applications. The output voltage waveform of a practical AC generator is replica of the space distribution of the ux density in the air gap and several factors such as shape of the rotor pole face, core saturation, slotting and style of coil disposition make the realization of a sinusoidal air gap ux wave impossible. These ux harmonics introduce undesirable e ects on the alternator performance like high neutral current due to triplen harmonics, voltage distortion, noise, vibration, excessive heating and also extra losses resulting in poor e ciency, which in turn necessitate de-rating of the machine especially when connected to non-linear loads. As an important control unit of brushless alternator, the excitation system and its dynamic performance has a direct impact on alternator's stability and reliability. The thesis explores design and implementation of an excitation i system utilizing third harmonic ux in the air gap of brushless al- ternators, using an additional auxiliary winding, wound for 1=3rd pole pitch, embedded into the stator slots and electrically iso- lated from the main winding. In the third harmonic excitation system, the combined e ect of two auxiliary windings, one with 2=3rd pitch and another third harmonic winding with 1=3rd pitch, are used to ensure good voltage regulation without an electronic automatic voltage regulator (AVR) and also reduces the total harmonic content in the output voltage, cost e ectively. The design of the third harmonic winding by analytic methods demands accurate calculation of third harmonic ux density in the air gap of the machine. However, precise estimation of the amplitude of third harmonic ux in the air gap of a machine by conventional design procedures is di cult due to complex geome- try of the machine and non-linear characteristics of the magnetic materials. As such, prediction of the eld parameters by conven- tional design methods is unreliable and hence virtual prototyping of the machine is done to enable accurate design of the third har- monic excitation system. In the design and development cycle of electrical machines, it is recognized that the use of analytical and experimental methods followed by expensive and in exible prototyping is time consum- ing and no longer cost e ective. Due to advancements in com- putational capabilities over recent years, nite element method (FEM) based virtual prototyping has become an attractive al- ternative to well established semi-analytical and empirical design methods as well as to the still popular trial and error approach followed by the costly and time consuming prototyping. Hence, by virtually prototyping the alternator using FEM, the important performance characteristics of the machine are predicted. Design of third harmonic excitation system is done with the help of results obtained from virtual prototype of the machine. Third harmonic excitation (THE) system is implemented in a 45 KVA ii experimental machine and experiments are conducted to validate the simulation results. Simulation and experimental results show that by utilizing third harmonic ux in the air gap of the ma- chine for excitation purposes during loaded conditions, triplen harmonic content in the output phase voltage is signi cantly re- duced. The prototype machine with third harmonic excitation system designed and developed based on FEM analysis proved to be economical due to its simplicity and has the added advan- tage of reduced harmonics in the output phase voltage.
Resumo:
A stand-alone power system is an autonomous system that supplies electricity to the user load without being connected to the electric grid. This kind of decentralized system is frequently located in remote and inaccessible areas. It is essential for about one third of the world population which are living in developed or isolated regions and have no access to an electricity utility grid. The most people live in remote and rural areas, with low population density, lacking even the basic infrastructure. The utility grid extension to these locations is not a cost effective option and sometimes technically not feasible. The purpose of this thesis is the modelling and simulation of a stand-alone hybrid power system, referred to as “hydrogen Photovoltaic-Fuel Cell (PVFC) hybrid system”. It couples a photovoltaic generator (PV), an alkaline water electrolyser, a storage gas tank, a proton exchange membrane fuel cell (PEMFC), and power conditioning units (PCU) to give different system topologies. The system is intended to be an environmentally friendly solution since it tries maximising the use of a renewable energy source. Electricity is produced by a PV generator to meet the requirements of a user load. Whenever there is enough solar radiation, the user load can be powered totally by the PV electricity. During periods of low solar radiation, auxiliary electricity is required. An alkaline high pressure water electrolyser is powered by the excess energy from the PV generator to produce hydrogen and oxygen at a pressure of maximum 30bar. Gases are stored without compression for short- (hourly or daily) and long- (seasonal) term. A proton exchange membrane (PEM) fuel cell is used to keep the system’s reliability at the same level as for the conventional system while decreasing the environmental impact of the whole system. The PEM fuel cell consumes gases which are produced by an electrolyser to meet the user load demand when the PV generator energy is deficient, so that it works as an auxiliary generator. Power conditioning units are appropriate for the conversion and dispatch the energy between the components of the system. No batteries are used in this system since they represent the weakest when used in PV systems due to their need for sophisticated control and their short lifetime. The model library, ISET Alternative Power Library (ISET-APL), is designed by the Institute of Solar Energy supply Technology (ISET) and used for the simulation of the hybrid system. The physical, analytical and/or empirical equations of each component are programmed and implemented separately in this library for the simulation software program Simplorer by C++ language. The model parameters are derived from manufacturer’s performance data sheets or measurements obtained from literature. The identification and validation of the major hydrogen PVFC hybrid system component models are evaluated according to the measured data of the components, from the manufacturer’s data sheet or from actual system operation. Then, the overall system is simulated, at intervals of one hour each, by using solar radiation as the primary energy input and hydrogen as energy storage for one year operation. A comparison between different topologies, such as DC or AC coupled systems, is carried out on the basis of energy point of view at two locations with different geographical latitudes, in Kassel/Germany (Europe) and in Cairo/Egypt (North Africa). The main conclusion in this work is that the simulation method of the system study under different conditions could successfully be used to give good visualization and comparison between those topologies for the overall performance of the system. The operational performance of the system is not only depending on component efficiency but also on system design and consumption behaviour. The worst case of this system is the low efficiency of the storage subsystem made of the electrolyser, the gas storage tank, and the fuel cell as it is around 25-34% at Cairo and 29-37% at Kassel. Therefore, the research for this system should be concentrated in the subsystem components development especially the fuel cell.
Resumo:
Contemporary food production, given the degree of technology being applied in it and the present state of scientific knowledge, should be able to feed the world. Corresponding statistics show that in fact the volumes of modern food production confirm this statement. Yet, the present nutritional situation across the globe leaves much to be desired: on the one hand the numbers of undernourished and malnourished people are still high and even growing in some regions, and on the other hand there is an increasing number of overweight and obese people who are experiencing (or are at risk of) adverse health impacts as consequences. The question arises how this situation is possible given the present state of food production and knowledge, and also in terms of nutrition basics when talking about the latter. When arguing about the main causes of the present situation with nutrition across the globe, it is the modern food system with its distortions that is often criticised with emphasis placed on inappropriate food distribution as one of the key problems. However it is not only food distribution that shapes inequalities in terms of food availability and accessibility – there is a number of other factors contributing to this situation including political influences. Each of the drivers of the present situation might affect more than one part and have outcomes in different dimensions. Therefore it makes sense to apply a holistic approach when viewing the modern food system, embracing all the elements and existing relationships between them for this will facilitate taking appropriate actions in order to target the desired outcome in the best possible way. Applying a systematic approach and linking various elements with corresponding interactions among them allows for picturing all the possible outcomes and hence finding the way for a better solution on global level – a solution to the present problem with nutritional disbalance across the globe.
Resumo:
The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand-alone device and as part of a pneumatic conveying system were investigated. In the former case granular attrition was carried out at three different rotary valve speeds and the experimental results obtained were found to be in good agreement with the Gwyn correlation. In the latter case three typical air flow rates were used in the pneumatic conveying system. The size distribution of the attrition product obtained at the lowest air flow rate used was not adequately described by the Gwyn correlation. The attrition process and mechanisms involved were analysed and the minimum size of the attrition product obtained from both modes of operations was found to be similar.
Resumo:
This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
Se realizó un estudio genético – poblacional en dos grupos etarios de población colombiana con la finalidad de evaluar las diferencias genéticas relacionadas con el polimorfismo MTHFR 677CT en busca de eventos genéticos que soporten la persistencia de este polimorfismo en la especie humana debido que este ha sido asociado con múltiples enfermedades. De esta manera se genotipificaron los individuos, se analizaron los genotipos, frecuencias alélicas y se realizaron diferentes pruebas genéticas-poblacionales. Contrario a lo observado en poblaciones Colombianas revisadas se identificó la ausencia del Equilibrio Hardy-Weinberg en el grupo de los niños y estructuras poblacionales entre los adultos lo que sugiere diferentes historias demográficas y culturales entre estos dos grupos poblacionales al tiempo, lo que soporta la hipótesis de un evento de selección sobre el polimorfismo en nuestra población. De igual manera nuestros datos fueron analizados junto con estudios previos a nivel nacional y mundial lo cual sustenta que el posible evento selectivo es debido a que el aporte de ácido fólico se ha incrementado durante las últimas dos décadas como consecuencia de las campañas de fortificación de las harinas y suplementación a las embarazadas con ácido fólico, por lo tanto aquí se propone un modelo de selección que se ajusta a los datos encontrados en este trabajo se establece una relación entre los patrones nutricionales de la especie humana a través de la historia que explica las diferencias en frecuencias de este polimorfismo a nivel espacial y temporal.
Resumo:
Las reacciones alérgicas a medicamentos cutáneas severas (RAM) como el Síndrome Stevens Johnson (SJS) y la Necrólisis Epidérmica Tóxica (NET),caracterizadas por exantema, erosión de la piel y las membranas mucosas, flictenas, desprendimiento de la piel secundario a la muerte de queratinocitos y compromiso ocular. Son infrecuentes en la población pero con elevada morbi-mortalidad, se presentan luego de la administración de diferentes fármacos. En Asia se ha asociado el alelo HLA-B*15:02 como marcador genético para SJS. En Colombia no hay datos de la incidencia de estas RAM, ni de la relación con medicamentos específicos o potenciales y tampoco estudios de aproximación genómica de genes de susceptibilidad.
Resumo:
Introducción: La simpatectomía es el tratamiento de la hiperhidrosis palmar y consiste en denervación simpática de miembros superiores que produce un efecto en el flujo sanguíneo al impactar la respuesta vasoconstrictora. El cambio en el flujo sanguíneo se puede evaluar a través de la onda fotopletismográfica. Metodología: Se realizaron 2 sesiones (presimpatectomía y postsimpatectomía) de 10 minutos en cada miembro superior en 28 pacientes obteniendo 79 señales fotopletismográficas distribuidas así: 37 presimpatectomía y 42 señales postsimpatectomía. De cada señal se analizó 1.5 minutos donde se tienen 80 ondas de fotopletismografía y se miden 6 variables: 1. Componente AC (componente pulsátil), 2. Componente DC (componente no pulsátil), 3. Relación entre AC/DC (índice de perfusión), 4. Area bajo la curva (AUC), 5. Tiempo entre el inicio de la onda y pico sistólico (T_DA) y 6. Tiempo entre cada onda de pulso (T_DD). Resultados: Aumentó 120% el componente AC y disminuyó 78% en DC del miembro superior derecho (MSD) con 99% de confiabilidad (p<0.001) entre presimpatectomía (n=18) y postsimpatectomía (n=21). AC/DC aumentó 55% con 95% de confiabilidad entre presimpatectomía (n=19) y postsimpatectomía (n=21) en el miembro superior izquierdo (p<0.05). No se encontró diferencia para T_DA, T_DD ni AUC. Discusión y Conclusión: La simpatectomía en pacientes con hiperhidrosis palmar produce un cambio en el flujo sanguíneo de los miembros superiores evidenciado por los cambios en el componente no pulsátil (DC) y pulsátil (AC) que es secundario a la vasodilatación consecuencia del bloqueo simpático por la denervación quirúrgica de los ganglios simpáticos torácicos.
Resumo:
Introducción: La infección por un tipo de Virus del Papiloma Humano de alto riesgo (VPH-AR), es el factor principal en el desarrollo de Cáncer de Cérvix (CC). La carga viral puede modular esta asociación, por lo que resulta importante su cuantificación y el establecimiento de su relación con lesiones precursoras de CC. Metodología: 60 mujeres con lesiones escamosas intraepiteliales (LEI) y 120 mujeres sin LEI, confirmadas por colposcopia, fueron incluidas en el estudio. Se determinó la carga viral de 6 tipos de VPH-AR, mediante PCR en tiempo real. Se estimaron OR crudos y ajustados para evaluar la asociación entre la carga viral de cada tipo y las lesiones cervicales. Resultados: 93.22% de mujeres con LEI y 91.23% de mujeres negativas, fueron positivas para al menos un tipo de VPH. VPH-18 y VPH-16 fueron los tipos más prevalentes, junto con VPH-31 en mujeres sin LEI. No se encontraron diferencias estadísticamente significativas de las cargas virales entre éstos dos grupos, aunque se observó un mayor carga viral en lesiones para algunos tipos virales. Una mayor frecuencia de lesiones se asoció a infecciones con carga baja de VPH-16 (ORa: 3.53; IC95%: 1.16 – 10.74), en comparación a mujeres con carga alta de VPH-16, (ORa: 2.63; IC95%: 1.09 – 6.36). En infecciones por VPH-31, la presencia de carga viral alta, se asoció con una menor frecuencia de lesiones (ORa: 0.34; IC95%: 0.15 – 0.78). Conclusiones: La prevalencia tipo-específica de VPH se corresponde con las reportadas a nivel mundial. La asociación entre la carga viral del VPH y la frecuencia de LEI es tipo específica y podría depender de la duración de la infección, altas cargas relacionadas con infecciones transitorias, y bajas cargas con persistentes. Este trabajo contribuye al entendimiento del efecto de la carga viral en la historia natural del CC; sin embargo, estudios prospectivos son necesarios para confirmar estos resultados.
Resumo:
Objetivo: Determinar los valores del índice cintura/cadera (ICC) en una población escolar de Bogotá, Colombia, pertenecientes al estudio FUPRECOL. Métodos: Estudio descriptivo y transversal, realizado en 3.005 niños y 2.916 adolescentes de entre 9 y 17,9 años de edad, pertenecientes a 24 instituciones educativas oficiales de Bogotá, Colombia. Se tomaron medidas de peso, talla, circunferencia de cintura, circunferencia de cadera. El estado de maduración sexual se recogió por auto-reporte. Se calcularon los percentiles (P3, P10, P25, P50, P75, P90 y P97) según sexo y edad y se realizó una comparación entre los valores del ICC observados con estándares internacionales. Resultados: De la población general (n=5.921), el 57,0% eran mujeres (promedio de edad 12,7 ± 2,3 años). En todas las edades el ICC fue mayor en los varones que en las mujeres, observándose un descenso en la media de los valores obtenidos desde los 9 hasta los 17,9 años. En varones, los valores del ICC mayores del P90 (asociados a riesgo cardiovascular) estuvieron en el rango 0,87 y 0,93 y en las mujeres entre 0,85 y 0,89. Al comparar los resultados de este estudio, por grupos de edad y sexo, con trabajos internacionales de niños y adolescentes de Europa, Suramérica, Asia y África, se observa que los valores del ICC fueron menores en este estudio en ambos sexos, con excepción de los escolares originarios de Grecia y Venezuela. Conclusiones: Se presentan percentiles del ICC según edad y sexo que podrán ser usados de referencia en la evaluación del estado nutricional y en la predicción del riesgo cardiovascular desde edades tempranas en población de Bogotá, Colombia.