898 resultados para Experience Sampling Methods
Resumo:
BACKGROUND: Lodox-Statscan is a whole-body, skeletal and soft-tissue, low-dose X-ray scanner Anterior-posterior and lateral thoraco-abdominal studies are obtained in 3-5 minutes with only about one-third of the radiation required for conventional radiography. Since its approval by the Food and Drug Administration (FDA) in the USA, several trauma centers have incorporated this technology into their Advanced Trauma Life Support protocols. This review provides a brief overview of the system, and describes the authors' own experience with the system. METHODS: We performed a PubMed search to retrieve all references with 'Lodox' and 'Stat-scan' used as search terms. We furthermore used the google search engine to identify existing alternatives. To the best of our knowledge, this is the only FDA-approved device of its kind currently used in trauma. RESULTS AND CONCLUSION: The intention of our review has been to sensitize the readership that such alternative devices exist. The key message is that low dosage full body radiography may be an alternative to conventional resuscitation room radiography which is usually a prelude to CT scanning (ATLS algorithm). The combination of both is radiation intensive and therefore we consider any reduction of radiation a success. But only the future will show whether LS will survive in the face of low-dose radiation CT scanners and magnetic resonance imaging devices that may eventually completely replace conventional radiography.
Resumo:
PURPOSE: To retrospectively evaluate the safety and effectiveness of the use of bivalirudin, a direct thrombin antagonist, compared with unfractionated heparin in endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Between March 1994 and September 2007, 740 consecutive patients (mean age, 75.7 y +/- 7.7; 69 women) underwent elective EVAR for infrarenal abdominal aortic aneurysm. Bivalirudin was used in 98 of these 740 (13.2%) and unfractioned heparin was used in the other 642 (86.8%). Complications were classified according to the Society of Vascular Surgery/International Society for Cardiovascular Surgery criteria. Major bleeding was defined as clinically overt blood loss resulting in a decrease of hemoglobin of more than 3 g/dL, any decrease in hemoglobin of more than 4 g/dL, transfusion of 2 U or more of red blood cells, or intracranial or retroperitoneal hemorrhage. RESULTS: Grade 1 major complications were observed in 161 of 642 patients (25.2%) in the heparin group and 12 of 98 patients (12.2%) in the bivalirudin group (P = .0046), whereas the incidences of grade 3 major complications were not significantly different between groups (P = .57). The rate of total complications was higher in the heparin group than in the bivalirudin group (247 of 642 [38.5%] vs 21 of 98 [21.4%]; P = .001). Major bleeding occurred in 10 of 98 patients (10.2%) receiving bivalirudin and in 91 of 642 patients (14.2%) receiving heparin (P = .34). One of 21 major complications (4.76%) in the bivalirudin group and 12 of 247 major complications (4.86%) in the heparin group were attributable to thrombosis (P = 1.0). CONCLUSIONS: Bivalirudin is a safe and feasible alternative to unfractionated heparin in patients undergoing EVAR.
Resumo:
BACKGROUND: Enquiries among patients on the one hand and experimental and observational studies on the other suggest an influence of stress on inflammatory bowel diseases (IBD). However, since this influence remains hypothetical, further research is essential. We aimed to devise recommendations for future investigations in IBD by means of scrutinizing previously applied methodology. METHODS: We critically reviewed prospective clinical studies on the effect of psychological stress on IBD. Eligible studies were searched by means of the PubMed electronic library and through checking the bibliographies of located sources. RESULTS: We identified 20 publications resulting from 18 different studies. Sample sizes ranged between 10 and 155 participants. Study designs in terms of patient assessment, control variables, and applied psychometric instruments varied substantially across studies. Methodological strengths and weaknesses were irregularly dispersed. Thirteen studies reported significant relationships between stress and adverse outcomes. CONCLUSIONS: Study designs, including accuracy of outcome assessment and repeated sampling of outcomes (i.e. symptoms, clinical, and endoscopic), depended upon conditions like sample size, participants' compliance, and available resources. Meeting additional criteria of sound methodology, like taking into account covariates of the disease and its course, is strongly recommended to possibly improve study designs in future IBD research.
Resumo:
High-resolution and highly precise age models for recent lake sediments (last 100–150 years) are essential for quantitative paleoclimate research. These are particularly important for sedimentological and geochemical proxies, where transfer functions cannot be established and calibration must be based upon the relation of sedimentary records to instrumental data. High-precision dating for the calibration period is most critical as it determines directly the quality of the calibration statistics. Here, as an example, we compare radionuclide age models obtained on two high-elevation glacial lakes in the Central Chilean Andes (Laguna Negra: 33°38′S/70°08′W, 2,680 m a.s.l. and Laguna El Ocho: 34°02′S/70°19′W, 3,250 m a.s.l.). We show the different numerical models that produce accurate age-depth chronologies based on 210Pb profiles, and we explain how to obtain reduced age-error bars at the bottom part of the profiles, i.e., typically around the end of the 19th century. In order to constrain the age models, we propose a method with five steps: (i) sampling at irregularly-spaced intervals for 226Ra, 210Pb and 137Cs depending on the stratigraphy and microfacies, (ii) a systematic comparison of numerical models for the calculation of 210Pb-based age models: constant flux constant sedimentation (CFCS), constant initial concentration (CIC), constant rate of supply (CRS) and sediment isotope tomography (SIT), (iii) numerical constraining of the CRS and SIT models with the 137Cs chronomarker of AD 1964 and, (iv) step-wise cross-validation with independent diagnostic environmental stratigraphic markers of known age (e.g., volcanic ash layer, historical flood and earthquakes). In both examples, we also use airborne pollutants such as spheroidal carbonaceous particles (reflecting the history of fossil fuel emissions), excess atmospheric Cu deposition (reflecting the production history of a large local Cu mine), and turbidites related to historical earthquakes. Our results show that the SIT model constrained with the 137Cs AD 1964 peak performs best over the entire chronological profile (last 100–150 years) and yields the smallest standard deviations for the sediment ages. Such precision is critical for the calibration statistics, and ultimately, for the quality of the quantitative paleoclimate reconstruction. The systematic comparison of CRS and SIT models also helps to validate the robustness of the chronologies in different sections of the profile. Although surprisingly poorly known and under-explored in paleolimnological research, the SIT model has a great potential in paleoclimatological reconstructions based on lake sediments
Resumo:
Background: Previous research has focused on the positive consequences of flow, an intrinsically rewarding state of deep absorption. In contrast, the present research links flow to impaired risk awareness and to risky behaviour. We expected flow to enhance self-efficacy beliefs, which in turn were hypothesised to result in low risk awareness and risky behaviour in sports. In addition, we predicted that individuals' level of experience in the activity would moderate the expected effects. Methods: One study with kayakers (Study 1) and two studies with rock climbers (Studies 2 and 3) were conducted. Kayakers completed a survey while still on the river; climbers responded during and upon completion of a climb. Results: In all studies flow was related to risk awareness. Study 2 additionally showed its association with risky behaviour. Studies 2 and 3 revealed that these relationships were mediated by self-efficacy. The mediations were moderated by level of experience (Study 3). Conclusions: The results indicated that inexperienced but not experienced participants respond to self-efficacy beliefs evoked by flow with impaired risk awareness and with risky behaviour. Theoretical implications for flow and risk research as well as practical implications for risk prevention are discussed.
Resumo:
In this note, we show that an extension of a test for perfect ranking in a balanced ranked set sample given by Li and Balakrishnan (2008) to the multi-cycle case turns out to be equivalent to the test statistic proposed by Frey et al. (2007). This provides an alternative interpretation and motivation for their test statistic.
Resumo:
OBJECTIVES To report a 10-year single center experience with Amplatzer devices for left atrial appendage (LAA) occlusion. BACKGROUND Intermediate-term outcome data following LAA occlusion are scarce. METHODS Short- and intermediate-term outcomes of patients who underwent LAA occlusion were assessed. All procedures were performed under local aesthesia without transesophageal echocardiography. Patients were discharged on acetylsalicylic acid and clopidogrel for 1-6 months. RESULTS LAA occlusion was attempted in 152 patients (105 males, age 72 ± 10 years, CHA2 DS2 -Vasc-score 3.4 ± 1.7, HAS-BLED-score 2.4 ± 1.2). Nondedicated devices were used in 32 patients (21%, ND group) and dedicated Amplatzer Cardiac Plugs were used in 120 patients (79%, ACP group). A patent foramen ovale or atrial septal defect was used for left atrial access and closed at the end of LAA occlusion in 40 patients. The short-term safety endpoints (procedural complications, bleeds) occurred in 15 (9.8%) and the efficacy endpoints (death, stroke, systemic embolization) in 0 patients. Device embolization occurred more frequently in the ND as compared to the ACP group (5 patients or 12% vs. 2 patients or 2%). Mean intermediate-term follow up of the study population was 32 months (range 1-120). Late deaths occurred in 15 patients (5 cardiovascular, 7 noncardiac, 3 unexplained). Neurologic events occurred in 2, peripheral embolism in 1, and major bleeding in 4 patients. The composite efficacy and safety endpoint occurred in 7% and 12% of patients. CONCLUSION LAA closure may be a good alternative to oral anticoagulation. This hypothesis needs to be tested in a randomized clinical trial to ensure that all potential biases of this observational study are accounted for.
Resumo:
OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device.
Resumo:
BACKGROUND Intraoperatively fabricated polymethylmethacrylate (PMMA) implants based on computer-designed moulds were used to improve cosmetic results after hard tissue replacement. To assess the implant's cosmetic and functional results we performed both subjective and objective assessments. METHODS This retrospective analysis was performed using a cohort of 28 patients who received PMMA implants between February 2009 and March 2012. The cosmetic and functional results were assessed using a patient questionnaire. Furthermore an objective volumetric subtraction score (0-100) was applied and implant thickness, as well as gaps and tiers, were measured. RESULTS Patients mainly judged their cosmetic result as "good". Two of the 28 patients found their cosmetic result unfavourable. The functional result and stability was mainly judged to be good. Measurements of implant thickness showed a very high correlation with the thickness of the contralateral bone. Volumetric subtraction led to a median quality of 80 on a scale from 0 to 100. Median gaps around the margins of the implant were 1.5 mm parietally, 1.7 mm frontally and 3.5 mm fronto-orbitally, and median tiers were 1.2 mm, 0 mm and 0 mm respectively. The overall rate of surgical revisions was 10.7 % (three patients). Two patients suffered from wound healing disturbances (7.1 %). The overall complication rate was comparable to other reports in the literature. CONCLUSIONS Implantation of intraoperatively fabricated patient-specific moulded implants is a cost-effective and safe technique leading to good clinical results with a low complication rate.
Resumo:
PURPOSE Validity of the seventh edition of the American Joint Committee on Cancer/International Union Against Cancer (AJCC/UICC) staging systems for gastric cancer has been evaluated in several studies, mostly in Asian patient populations. Only few data are available on the prognostic implications of the new classification system on a Western population. Therefore, we investigated its prognostic ability based on a German patient cohort. PATIENTS AND METHODS Data from a single-center cohort of 1,767 consecutive patients surgically treated for gastric cancer were classified according to the seventh edition and were compared using the previous TNM/UICC classification. Kaplan-Meier analyses were performed for all TNM stages and UICC stages in a comparative manner. Additional survival receiver operating characteristic analyses and bootstrap-based goodness-of-fit comparisons via Bayesian information criterion (BIC) were performed to assess and compare prognostic performance of the competing classification systems. RESULTS We identified the UICC pT/pN stages according to the seventh edition of the AJCC/UICC guidelines as well as resection status, age, Lauren histotype, lymph-node ratio, and tumor grade as independent prognostic factors in gastric cancer, which is consistent with data from previous Asian studies. Overall survival rates according to the new edition were significantly different for each individual's pT, pN, and UICC stage. However, BIC analysis revealed that, owing to higher complexity, the new staging system might not significantly alter predictability for overall survival compared with the old system within the analyzed cohort from a statistical point of view. CONCLUSION The seventh edition of the AJCC/UICC classification was found to be valid with distinctive prognosis for each stage. However, the AJCC/UICC classification has become more complex without improving predictability for overall survival in a Western population. Therefore, simplification with better predictability of overall survival of patients with gastric cancer should be considered when revising the seventh edition.
Resumo:
Background: As scholars who prepare future school leaders to be innovative instructional leaders for their learning communities, we are on the verge of a curriculum design revolution. The application of brain research findings promotes educational reform efforts to systemically change the way in which children experience school. However, most educators, school leaders, board members, and policy makers are ill prepared to reconsider the implications for assessment, pedagogy, school climate, daily schedules, and use of technology. This qualitative study asked future school leaders to reconsider how school leadership preparedness programs prepared them to become instructional leaders for the 21st century. The findings from this study will enhance the field of school leadership, challenging the current emphasis placed on standardized testing, traditional school calendars, assessments, monocultural instructional methods, and meeting the needs of diverse learning communities. [See PDF for complete abstract]
Resumo:
Introduction This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure. Methods and Results A total of 55 patients were enrolled in this study of the novel ACD. Of the 55 patients, 39 were enrolled in the DA group and 16 were enrolled in the PCI group. Six patients were excluded. A device was deployed in 49 patients. Time to hemostasis (TTH), time to ambulation (TTA), device function, and device-related vascular complications were measured. In the device group, the TTH for the combined DA and PCI patients was 32 seconds (0.54 ± 0.93 minutes), significantly lower when compared with 16.0 ± 12.2 minutes (P < 0.0001) for the control group. Overall major vascular complication rate did not differ significantly, device group (1/49) and the historical control group (1/217). TTA in the combined PCI and DA device group was 226.4 ± 231.9 at the German site (site ambulation policy). In the Irish site, the average TTA in the PCI group was 187 minutes (n = 8) and 85 minutes (n = 14) in the DA group. Conclusion The Celt ACD® device is safe, effective, and significantly decreases the TTH compared to manual pressure and has a low vascular complications rate. The device may be effective in early ambulation and discharge of patients postcoronary intervention procedures.
Resumo:
How do university training and subsequent practical experience affect expertise in clinical psychology? To answer this question we developed methods to assess psychological knowledge and the competence to diagnose, construct case conceptualizations, and plan psychotherapeutic treatment: a knowledge test and short case studies in a first study, and a complex, dynamically evolving case study in the second study. In our cross-sectional studies, psychology students, trainees in a certified postgraduate psychotherapist curriculum, and behavior therapists with more than 10 years of experience were tested (100 in total: 20 each of novice, intermediate, and advanced university students, postgraduate trainees, and therapists). Clinical knowledge and competence increased up to the level of trainees but unexpectedly decreased at the level of experienced therapists. We discuss the results against the background of expertise research and the training of clinical psychologists (in Germany). Important factors for the continuing professional development of psychotherapists are proposed.
Resumo:
INTRODUCTION: Thyroid cancer is the most common endocrine malignancy. The outcomes of patients with relapsed thyroid cancer treated on early-phase clinical trials have not been systematically analyzed. PATIENTS AND METHODS: We reviewed the records of consecutive patients with metastatic thyroid cancer referred to the Phase I Clinical Trials Program from March 2006 to April 2008. Best response was assessed by Response Evaluation Criteria in Solid Tumors. RESULTS: Fifty-six patients were identified. The median age was 55 yr (range 35-79 yr). Of 49 patients evaluable for response, nine (18.4%) had a partial response, and 16 (32.7%) had stable disease for 6 months or longer. The median progression-free survival was 1.12 yr. With a median follow-up of 15.6 months, the 1-yr survival rate was 81%. In univariate analysis, factors predicting shorter survival were anaplastic histology (P = 0.0002) and albumin levels less than 3.5 g/dl (P = 0.05). Among 26 patients with tumor decreases, none died (median follow-up 1.3 yr), whereas 52% of patients with any tumor increase died by 1 yr (P = 0.0001). The median time to failure in our phase I clinical trials was 11.5 months vs. 4.1 months for the previous treatment (P = 0.04). CONCLUSION: Patients with advanced thyroid cancer treated on phase I clinical trials had high rates of partial response and prolonged stable disease. Time to failure was significantly longer on the first phase I trial compared with the prior conventional treatment. Patients with any tumor decrease had significantly longer survival than those with any tumor increase.
Resumo:
OBJECTIVE: The objective of this study was to evaluate the impact of newer therapies on the highest risk patients with congenital diaphragmatic hernia (CDH), those with agenesis of the diaphragm. SUMMARY BACKGROUND DATA: CDH remains a significant cause of neonatal mortality. Many novel therapeutic interventions have been used in these infants. Those children with large defects or agenesis of the diaphragm have the highest mortality and morbidity. METHODS: Twenty centers from 5 countries collected data prospectively on all liveborn infants with CDH over a 10-year period. The treatment and outcomes in these patients were examined. Patients were followed until death or hospital discharge. RESULTS: A total of 1,569 patients with CDH were seen between January 1995 and December 2004 in 20 centers. A total of 218 patients (14%) had diaphragmatic agenesis and underwent repair. The overall survival for all patients was 68%, while survival was 54% in patients with agenesis. When patients with diaphragmatic agenesis from the first 2 years were compared with similar patients from the last 2 years, there was significantly less use of ECMO (75% vs. 52%) and an increased use of inhaled nitric oxide (iNO) (30% vs. 80%). There was a trend toward improved survival in patients with agenesis from 47% in the first 2 years to 59% in the last 2 years. The survivors with diaphragmatic agenesis had prolonged hospital stays compared with patients without agenesis (median, 68 vs. 30 days). For the last 2 years of the study, 36% of the patients with agenesis were discharged on tube feedings and 22% on oxygen therapy. CONCLUSIONS: There has been a change in the management of infants with CDH with less frequent use of ECMO and a greater use of iNO in high-risk patients with a potential improvement in survival. However, the mortality, hospital length of stay, and morbidity in agenesis patients remain significant.