Initial clinical experience with the Coherex FlatStent™ and FlatStent™ EF PFO closure system for in-tunnel PFO closure: Results of the Coherex-EU study
Data(s) |
01/06/2014
|
---|---|
Resumo |
OBJECTIVE The Coherex-EU Study evaluated the safety and efficacy of PFO closure utilizing novel in-tunnel PFO closure devices. BACKGROUND Transcatheter closure of patent foramen ovale (PFO) followed the development of transcatheter closure devices designed to patch atrial septal defects (ASDs). The Coherex FlatStent™ and FlatStent™ EF devices were designed specifically to treat PFO anatomy. METHODS A total of 95 patients with a clinical indication for PFO closure were enrolled in a prospective, multicenter first in man study at six clinical sites. Thirty-six patients received the first-generation FlatStent study device, and 57 patients received the second-generation FlatStent EF study device, which was modified based on clinical experience during the first 38 cases. Two patients enrolled to receive the first generation did not receive a device. RESULTS At 6 months post-procedure, 45% (17/38) of the intention-to-treat (ITT) cohort receiving the first-generation FlatStent device had complete closure, 26% (10/38) had a trivial residual shunt, and 29% (11/38) had a moderate to large residual shunt. In the ITT cohort receiving the second-generation FlatStent EF device, 76% (43/57) had complete closure, 12% (7/57) had a trivial shunt, and 12% had a moderate to large shunt. Five major adverse events occurred, all without sequelae. CONCLUSION This initial study of the Coherex FlatStent/FlatStent EF PFO Closure System demonstrated the potential for in-tunnel PFO closure. The in-tunnel Coherex FlatStent EF may offer an alternative to septal repair devices for PFO closure in appropriately selected patients; however, further investigation will be necessary to establish the best use of this device. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/44978/1/ccd24565.pdf Sievert, Horst; Wunderlich, Nina; Reiffenstein, Isabel; Ruygrok, Peter; Grube, Eberhard; Büllesfeld, Lutz; Meier, Bernhard; Schofer, Joachim; Muller, David; Jones, Randall K; Gillam, Linda (2014). Initial clinical experience with the Coherex FlatStent™ and FlatStent™ EF PFO closure system for in-tunnel PFO closure: Results of the Coherex-EU study. Catheterization and cardiovascular interventions, 83(7), pp. 1135-1143. Wiley-Blackwell 10.1002/ccd.24565 <http://dx.doi.org/10.1002/ccd.24565> doi:10.7892/boris.44978 info:doi:10.1002/ccd.24565 info:pmid:22815250 urn:issn:1522-1946 |
Idioma(s) |
eng |
Publicador |
Wiley-Blackwell |
Relação |
http://boris.unibe.ch/44978/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Sievert, Horst; Wunderlich, Nina; Reiffenstein, Isabel; Ruygrok, Peter; Grube, Eberhard; Büllesfeld, Lutz; Meier, Bernhard; Schofer, Joachim; Muller, David; Jones, Randall K; Gillam, Linda (2014). Initial clinical experience with the Coherex FlatStent™ and FlatStent™ EF PFO closure system for in-tunnel PFO closure: Results of the Coherex-EU study. Catheterization and cardiovascular interventions, 83(7), pp. 1135-1143. Wiley-Blackwell 10.1002/ccd.24565 <http://dx.doi.org/10.1002/ccd.24565> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |