Intraoperative fabrication of patient-specific moulded implants for skull reconstruction: single-centre experience of 28 cases


Autoria(s): Stieglitz, Lennart Henning; Gerber, Nicolas; Schmid, Thomas; Mordasini, Pasquale; Fichtner, Jens; Fung, Christian; Murek, Michael; Weber, Stefan; Raabe, Andreas; Beck, Jürgen
Data(s)

18/01/2014

Resumo

BACKGROUND Intraoperatively fabricated polymethylmethacrylate (PMMA) implants based on computer-designed moulds were used to improve cosmetic results after hard tissue replacement. To assess the implant's cosmetic and functional results we performed both subjective and objective assessments. METHODS This retrospective analysis was performed using a cohort of 28 patients who received PMMA implants between February 2009 and March 2012. The cosmetic and functional results were assessed using a patient questionnaire. Furthermore an objective volumetric subtraction score (0-100) was applied and implant thickness, as well as gaps and tiers, were measured. RESULTS Patients mainly judged their cosmetic result as "good". Two of the 28 patients found their cosmetic result unfavourable. The functional result and stability was mainly judged to be good. Measurements of implant thickness showed a very high correlation with the thickness of the contralateral bone. Volumetric subtraction led to a median quality of 80 on a scale from 0 to 100. Median gaps around the margins of the implant were 1.5 mm parietally, 1.7 mm frontally and 3.5 mm fronto-orbitally, and median tiers were 1.2 mm, 0 mm and 0 mm respectively. The overall rate of surgical revisions was 10.7 % (three patients). Two patients suffered from wound healing disturbances (7.1 %). The overall complication rate was comparable to other reports in the literature. CONCLUSIONS Implantation of intraoperatively fabricated patient-specific moulded implants is a cost-effective and safe technique leading to good clinical results with a low complication rate.

Formato

application/pdf

Identificador

http://boris.unibe.ch/45810/1/art%253A10.1007%252Fs00701-013-1977-5.pdf

Stieglitz, Lennart Henning; Gerber, Nicolas; Schmid, Thomas; Mordasini, Pasquale; Fichtner, Jens; Fung, Christian; Murek, Michael; Weber, Stefan; Raabe, Andreas; Beck, Jürgen (2014). Intraoperative fabrication of patient-specific moulded implants for skull reconstruction: single-centre experience of 28 cases. Acta neurochirurgica, 156(4), pp. 793-803. Springer 10.1007/s00701-013-1977-5 <http://dx.doi.org/10.1007/s00701-013-1977-5>

doi:10.7892/boris.45810

info:doi:10.1007/s00701-013-1977-5

info:pmid:24442601

urn:issn:0001-6268

Idioma(s)

eng

Publicador

Springer

Relação

http://boris.unibe.ch/45810/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Stieglitz, Lennart Henning; Gerber, Nicolas; Schmid, Thomas; Mordasini, Pasquale; Fichtner, Jens; Fung, Christian; Murek, Michael; Weber, Stefan; Raabe, Andreas; Beck, Jürgen (2014). Intraoperative fabrication of patient-specific moulded implants for skull reconstruction: single-centre experience of 28 cases. Acta neurochirurgica, 156(4), pp. 793-803. Springer 10.1007/s00701-013-1977-5 <http://dx.doi.org/10.1007/s00701-013-1977-5>

Palavras-Chave #610 Medicine & health #570 Life sciences; biology #940 History of Europe
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed