929 resultados para Edge detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atmospheric parameters, Such as pressure (P), temperature (T) and density (rho proportional to P/T), affect the development of extensive air showers initiated by energetic cosmic rays. We have Studied the impact of atmospheric variations on extensive air showers by means of the surface detector of the Pierre Auger Observatory. The rate of events shows a similar to 10% seasonal modulation and similar to 2% diurnal one. We find that the observed behaviour is explained by a model including the effects associated with the variations of P and rho. The former affects the longitudinal development of air showers while the latter influences the Moliere radius and hence the lateral distribution of the shower particles. The model is validated with full simulations of extensive air showers using atmospheric profiles measured at the site of the Pierre Auger Observatory. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Pierre Auger Observatory is a detector for ultra-high energy cosmic rays. It consists of a surface array to measure secondary particles at ground level and a fluorescence detector to measure the development of air showers in the atmosphere above the array. The ""hybrid"" detection mode combines the information from the two subsystems. We describe the determination of the hybrid exposure for events observed by the fluorescence telescopes in coincidence with at least one water-Cherenkov detector of the surface array. A detailed knowledge of the time dependence of the detection operations is crucial for an accurate evaluation of the exposure. We discuss the relevance of monitoring data collected during operations, such as the status of the fluorescence detector, background light and atmospheric conditions, that are used in both simulation and reconstruction. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions. (C) 2010 Elsevier B.V All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach was developed for nitrate analysis in a FIA configuration with amperometric detection (E=-0.48 V). Sensitive and reproducible current measurements were achieved by using a copper electrode activated with a controlled potential protocol. The response of the FIA amperometric method was linear over the range from 0.1 to 2.5 mmol L(-1) nitrate with a detection limit of 4.2 mu mol L(-1) (S/N = 3). The repeatability of measurements was determined as 4.7% (n=9) at the best conditions (flow rate: 3.0 mL min(-1), sample volume: 150 mu L and nitrate concentration: 0.5 mmol L(-1)) with a sampling rate of 60 samples h(-1). The method was employed for the determination of nitrate in mineral water and soft drink samples and the results were in agreement with those obtained by using a recommended procedure. Studies towards a selective monitoring of nitrite were also performed in samples containing nitrate by carrying out measurements at a less negative potential (-0.20 V). (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An all-in-one version of a capacitively coupled contactless conductivity detector is introduced. The absence of moving parts (potentiometers and connectors) makes it compact (6.5 cm(3)) and robust. A local oscillator, working at 1.1 MHz, was optimized to use capillaries of id from 20 to 100 lam. Low noise circuitry and a high-resolution analog-to-digital converter (ADC) (21 bits effective) grant good sensitivities for capillaries and background electrolytes currently used in capillary electrophoresis. The fixed frequency and amplitude of the signal generator is a drawback that is compensated by the steady calibration curves for conductivity. Another advantage is the possibility of determining the inner diameter of a capillary by reading the ADC when air and subsequently water flow through the capillary. The difference of ADC reading may be converted into the inner diameter by a calibration curve. This feature is granted by the 21-bit ADC, which eliminates the necessity of baseline compensation by hardware. In a typical application, the limits of detection based on the 3 sigma criterion (without baseline filtering) were 0.6, 0.4, 0.3, 0.5, 0.6, and 0.8 mu mol/L for K(+), Ba(2+), Ca(2+), Na(+), Mg(2+), and Li(+), respectively, which is comparable to other high-quality implementations of a capacitively coupled contactless conductivity detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new compact system encompassing in flow gas diffusion unit and a wall-jet amperometric FIA detector, coated with a supramolecular porphyrin film, was specially designed as an alternative to the time-consuming Monier-Williams method, allowing fast, reproducible and accurate analyses of free sulphite species in fruit juices. In fact, a linear response between 0.64 and 6.4 ppm of sodium sulphite. LOD = 0.043 ppm, relative standard deviation of +/- 1.5% (n = 10) and analytical frequency of 85 analyses/h were obtained utilising optimised conditions. That superior analytical performance allows the precise evaluation of the amount of free sulphite present in foods, providing an important comparison between the standard addition and the standard injection methods. Although the first one is most frequently used, it was strongly influenced by matrix effects because of the unexpected reactivity of sulphite ions with the juice matrixes, leading to its partial consumption soon after addition. In contrast, the last method was not susceptible to matrix effects yielding accurate results, being more reliable for analytical purposes. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two decades after mountaineer Bill Holland ’72 was lost in a fall, his daughter retraces his steps on Mayflower Hill.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have focused on the optical absorption edge of nanocrystalline Ga(1-x)Mn(x)N (0.00 <= x <= 0.18) films deposited by reactive RF magnetron sputtering. The films obtained are nanocrystalline with grain sizes of about 25 nm, having wurtzite structure and strong orientation texture in the c-axis direction. The optical characterizations of the absorption edges were obtained in the 190-2600 nm spectral range. The increase of the Mn content causes an increase of the absorption coefficient which can be clearly noticed at low energies, and a quasi-linear decrease of the optical gap. Broad absorption bands observed around similar to 1.3 and similar to 2.2 eV were associated with transitions between the Mn acceptor level and the valence and conduction bands, respectively. The observed changes in the optical properties due to the Mn incorporation observed in these nanocrystalline films are similar to those reported for ferromagnetic GaMnN single-crystal films.