A compact and high-resolution version of a capacitively coupled contactless conductivity detector


Autoria(s): FRANCISCO, Kelliton Jose Mendonca; LAGO, Claudimir Lucio do
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

20/10/2012

20/10/2012

2009

Resumo

An all-in-one version of a capacitively coupled contactless conductivity detector is introduced. The absence of moving parts (potentiometers and connectors) makes it compact (6.5 cm(3)) and robust. A local oscillator, working at 1.1 MHz, was optimized to use capillaries of id from 20 to 100 lam. Low noise circuitry and a high-resolution analog-to-digital converter (ADC) (21 bits effective) grant good sensitivities for capillaries and background electrolytes currently used in capillary electrophoresis. The fixed frequency and amplitude of the signal generator is a drawback that is compensated by the steady calibration curves for conductivity. Another advantage is the possibility of determining the inner diameter of a capillary by reading the ADC when air and subsequently water flow through the capillary. The difference of ADC reading may be converted into the inner diameter by a calibration curve. This feature is granted by the 21-bit ADC, which eliminates the necessity of baseline compensation by hardware. In a typical application, the limits of detection based on the 3 sigma criterion (without baseline filtering) were 0.6, 0.4, 0.3, 0.5, 0.6, and 0.8 mu mol/L for K(+), Ba(2+), Ca(2+), Na(+), Mg(2+), and Li(+), respectively, which is comparable to other high-quality implementations of a capacitively coupled contactless conductivity detector.

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Fundacao de Amparo Pesquisa do Estado de Sao Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Conselho Nacional de Desenvolvmtento Cientifico e Tecnologico (CNPq)

Identificador

ELECTROPHORESIS, v.30, n.19, p.3458-3464, 2009

0173-0835

http://producao.usp.br/handle/BDPI/31152

10.1002/elps.200900080

http://dx.doi.org/10.1002/elps.200900080

Idioma(s)

eng

Publicador

WILEY-V C H VERLAG GMBH

Relação

Electrophoresis

Direitos

restrictedAccess

Copyright WILEY-V C H VERLAG GMBH

Palavras-Chave #Alkaline ions #Caffeine #Contactless conductivity detection #Detection #Dynamic range #MICROCHIP CAPILLARY-ELECTROPHORESIS #ELECTROKINETIC CHROMATOGRAPHY #CONDUCTOMETRIC DETECTOR #OSCILLOMETRIC DETECTOR #ZONE-ELECTROPHORESIS #DETECTION CELL #AMINO-ACIDS #FREQUENCY #SEPARATION #OPTIMIZATION #Biochemical Research Methods #Chemistry, Analytical
Tipo

article

original article

publishedVersion