918 resultados para coefficient of discharge


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nanometer-scale plowing friction and wear of a polycarbonate thin film were directly measured using an atomic force microscope (AFM) with nanoscratching capabilities. During the nanoscratch tests, lateral forces caused discrepancies between the maximum forces for the initial loadings prior to the scratch and the unloading after the scratch. In the case of a nanoscratch test performed parallel to the cantilever probe axis, the plowing friction added another component to the moment acting at the cantilevered end compared to the case of nanoindentation, resulting in an increased deflection of the cantilever. Using free-body diagrams for the cases of nanoindentation and nanoscratch testing, the AFM force curves were analyzed to determine the plowing friction during nanoscratch testing. From the results of this analysis, the plowing friction was found to be proportional to the applied contact force, and the coefficient of plowing friction was measured to be 0.56 +/- 0.02. Also, by the combination of nanoscratch and nanoindentation testing, the energetic wear rate of the polycarbonate thin film was measured to be 0.94 +/- 0.05 mm(3)/(N m).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of potassium thiocyanate on the partitioning of lysozyme and BSA in polyethylene glycol 2000/ammonium sulfate aqueous two-phase system has been investigated. As a result of the addition of potassium thiocyanate to the PEG/ammonium sulfate system, the PEG/mixed salts aqueous two-phase system was formed. It was found that the potassium thiocyanate could alter the pH difference between the two phases, and, thus, influence the partition coefficients of the differently charged proteins. The relationship between partition coefficient of the proteins and pH difference between two phases has been discussed. It was proposed that the pH difference between two phases could be employed as the measurement of electrostatic driving force for the partitioning of charged proteins in polyethylene glycol 2000/ammonium sulfate aqueous two-phase system.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A new method for immobilization of a chemiluminescent reagent is presented. It is based on immobilizing hematin, a catalyst for luminol reaction, in the bulk of a carbon paste electrode. Bulk-immobilization allows renewal of the surface by simple polishing or cutting to expose anew and fully active surface in the case of fouling or deactivation by other means. By using a hematin-modified carbon paste electrode, the applied potential shifted negatively compared with that of unmodified carbon paste electrode or a glassy carbon electrode. The shift in potential changed the reaction processes and effectively stabilized the chemiluminescent signal during successive measurements. Under this condition, the signal was stable during 3 hours of continuous operation. The log-log plots of the emitted light intensity vs. luminol concentration and hydrogen peroxide concentration were linear over the region 10(-8)-10(-3) mol L-1 with a correlation coefficient of 0.999 and 3.9 x 10(-6)-10(-3) mol L-1 with a correlation coefficient of 0.994, respectively. Application of this method for other chemiluminescent and bioluminescent systems is suggested.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel method for the highly sensitive determination of perchlorate was proposed. It was based on solvent extraction in the presence of Ru(bpy)(3)(2+) followed by Ru(bpy)(3)(2+) electrochemiluminescent determination. A linear calibration was obtained over the range of 0.1 to 10 mu mol l(-1) with a correlation coefficient of 0.998. The detection limit (S/N = 3) was 5.0 x 10(-8) mol l(-1). The relative standard deviation for 10 replicates of 1 mu mol l(-1) perchlorate was 1.6%. Interference studies suggest that this method is selective for the determination of perchlorate. Application of this method to the highly sensitive determination of other anions is suggested. (C) 1999 Elsevier Science S.A. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Selectivity coefficient measurement has been performed for K+,Ni2+,Fe3+ with Nafion 117 perfluorosulfonate polymer as-received forms. The results show that a linear Nernst response is exhibited for H+,K+,Pb2+,Ni2+,Co2+,Fe3+, and the ion selectivity coefficient of Nafion membrane for KC is better than Ni2+ and Fe3+.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Separation of Th4+ and RE3+ was investigated by hollow fiber membrane extraction with N1923 in countercurrent recirculating operation. The effect of Hf concentration in aqueous phase and flow rates of aqueous and organic phases on mass transfer coefficient was tested. Then the extraction of Th4+ from RE sulfate obtained from Baotou ore was carried out. The results obtained show that the mass transfer coefficient of Th4+ changes with the flow rate of aqueous phase, but does not change with the flow rate of organic phase and H+ concentration in aqueous phase, which suggests that the mass transfer rate of Th4+ is controlled bg that in the water critical layer, The mass transfer rate of RE3+ does not change with the flow rate of water phase, changes a little with the flow rate of organic phase, and changes with H+ concentration, which suggests that the mass transfer rate is controlled by their reaction rate with N1923. Th4+ could be extracted completely in 8 h from RE sulfate solution of Baotou ore with relatively less extraction of RE3+. So the separation of radioactive element under the sealed condition could be done.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A flow injection analysis detection method for glucose is presented which is based on the oxidation of glucose by glucose oxidase followed by chemiluminescent detection of hydrogen peroxide. Both glucose oxidase and hematin, a chemiluminescent reaction catalyst, were bulk-immobilized conveniently by direct mixing with carbon paste, which allows renewal of the electrode surface by simply polishing or cutting to expose a new and fully active surface in the case of fouling. Luminol in reagent solution passed through the flow cell and reacted with hydrogen peroxide produced by the enzyme reactor in the presence of the catalyst to yield light. An applied potential of -0.4 V avoided the electrode fouling effectively. The log-log plot of the emitted light intensity vs glucose concentration was linear over the range of 1-100 mmol L-1 with a correlation coefficient of 0.992. Application of this method to other chemiluminescent and bioluminescent systems is suggested. (C) 1999 Academic Press.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A rapid and sensitive detection method for the determination of 5-fluorouracil(5-FU) in real samples such as human urine and bovine serum albumin (BSA) was described. A carbon fiber microdisk electrode was used to perform end-column amperometric detection in capillary zone electrophoresis. The detection limit was as low as 2.5x10(-7) M and the wider linear range for the concentration was between 5x10(-6) and 1x10(-4) M with a correlation coefficient of 0.995.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

From the chemical bond viewpoint, second-order nonlinear optical (NLO) tensor coefficients of the family of new oxoborates Ca4ReO(BO3)(3) (CReOB, Re = La, Nd, Sm, Gd, Er, and Y) have been theoretically predicted. The d(11) tensor coefficient of CReOB is predicted to be -11 d(36)(KDP), which is the largest d(ij) tensor that has been found in borate crystals. From the structural characteristic of CReOB, we find the isolated BO33- clusters play a dominant role in contributions to the total nonlinearity, and the largest d(11) tensor of CReOB-type crystals is also ascribed to these BO33- clusters. We also find the NLO property of this family does not change dramatically for different rare-earth elements. The details of the calculation of CGdOB only are presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Separation of Ce(IV) and RE(III) was investigated by hollow fiber membrane-based extraction with contercurrent recirculating operation. The mass transfer coefficients of Ce(IV) and RE(III) and the effective factors to them were tested. The results show the mass transfer coefficient of Ce(IV) is larger than that of RE(III), and their mass transfer mechanism is different. The mass transfer of Ce(IV) was controlled by the resistance in water critical layer due to its more rapid interfacial reaction rate and larger distribution coefficient, which was different from RE(III) mass transfer with a slow interfacial reaction rate and small distribution coefficient. Ce(IV) was separated from the mixed solution of Ce(IV) and RE(III) by means of the difference of their mass transfer rates.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A highly dispersed ultramicro palladium-particle modified carbon fiber microdisk array electrode (Pd-CFE) was employed for capillary electrophoresis-electrochemical (CEEC) detection of hydroxylamine (HA). The Pd particles obtained were in the nanometer scale, had a high electrocatalytic activity towards HA and exhibited good reproducibility and stability. A linear relationship between the current and the analyte concentration was found between 5 x 10(-6) and 1 x 10(-3) mol/l of HA with a correlation coefficient of 0.9992. The detection limit was 5 x 10(-8) mol/l. The applicability of the method for the determination of HA in river water and waste water was investigated.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A palladium particle-modified carbon fiber microdisk array electrode was designed and employed in capillary electrophoresis for the simultaneous detection of hydrazine, methylhydrazine, and isoniazid. The Pd-modified microdisk electrode had high catalytic ability for hydrazines and exhibited good reproducibility and stability. The response for hydrazine was linear over 3 orders of magnitude with a correlation coefficient of 0.993. The detection limits far hydrazine, methylhydrazine, and isoniazid were 1.2, 2.1, and 6.2 pg, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Eastman-AQ 55D was coated onto a carbon fiber microelectrode surface, and the resulting modified electrodes exhibited high stability. Substantial improvement in the stability was observed as a result of good adhesion and the strong binding of large hydrophobic cations of Eastman AQ 55D. The electrode reaction of meldola blue bound in the polymer film showed a reversible, one-electron transfer process. The effects of solution pH and influence of supporting electrolyte on the modified carbon fiber microelectrode are discussed. The diffusion coefficient of meldola blue in the AQ polymer film determined by chronoamperometry is 2.3 x 10(-18) cm(2) s(-1), and the heterogeneous rate constant of meldola blue at the AQ polymer film/electrode determined by normal pulse voltammetry is 3.97 x 10(-3) cms(-1).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The electrocatalytic oxidation of NADH by ferrocene derivatives and the influence of complexation with beta-cyclodextrin (beta-CD) were investigated at a microdisk electrode in a buffer solution. The cyclic voltammetric behavior of the ferrocene derivatives on the microdisk electrode was used to determine the electron-transfer rate constant from NADH to the ferricinium species. The heterogeneous rate constants and the diffusion coefficient of ferrocene derivatives were determined with the microdisk electrode. The effect of temperature and pH on the electrocatalytic oxidation of NADH were assessed.