777 resultados para P-y curves, offshore foundation, pile foundation, jacket structures, Plaxis3D 2013
Resumo:
Assembly processes used to bond components to printed circuit boards can have a significant impact on these boards and the final packaged component. Traditional approaches to bonding components to printed circuit boards results in heat being applied across the whole board assembly. This can lead to board warpage and possibly high residual stresses. Another approach discussed in this paper is to use Variable Frequency Microwave (VFM) heating to cure adhesives and underfills and bond components to printed circuit boards. In terms of energy considerations the use of VFM technology is much more cost effective compared to convection/radiation heating. This paper will discuss the impact of traditional reflow based processes on flexible substrates and it will demonstrate the possible advantages of using localised variable frequency microwave heating to cure materials in an electronic package.
Resumo:
Encapsulant curing using a Variable Frequency Microwave (VFM) system is analysed numerically. Thermosetting polymer encapsulant materials require an input of heat energy to initiate the cure process. In this article, the heating is considered to be performed by a novel microwave system, able to perform the curing process more rapidly than conventional techniques. Thermal stresses are induced when packages containing materials with differing coefficients of thermal expansion are heated, and cure stresses are induced as thermosetting polymer materials shrink during the cure process. These stresses are developed during processing and remain as residual stresses within the component after the manufacturing process is complete. As residual stresses will directly affect the reliability of the device, it is necessary to assess their magnitude and the effect on package reliability. A coupled multiphysics model has been developed to numercially analyse the microwave curing process. In order to obtain a usefully accurate model of this process, a holistic approach has been taken, in which the process is not considered to be a sequence of discrete steps, but as a complex coupled system. An overview of the implemented numerical model is presented, with particular focus paid to analysis of induced thermal stresses. Results showing distribution of stresses within an idealised microelectronics package are presented and discussed.
Resumo:
Curing of encapsulant material in a simplified microelectronics package using an open oven Variable Frequency Microwave (VFM) system is numerically simulated using a coupled solver approach. A numerical framework capable of simulating electromagnetic field distribution within the oven system, plus heat transfer, cure rate, degree of cure and thermally induced stresses within the encapsulant material is presented. The discrete physical processes have been integrated into a fully coupled solution, enabling usefully accurate results to be generated. Numerical results showing the heating and curing of the encapsulant material have been obtained and are presented in this contribution. The requirement to capture inter-process coupling and the variation in dielectric and thermophysical material properties is discussed and illustrated with simulation results.
Resumo:
This paper presents the challenges encountered in modelling biofluids in microchannels. In particular blood separation implemented in a T-microchannel device is analysed. Microfluids behave different from the counterparts in the microscale and a different approach has been adopted here to model them, which emphasize the roles of viscous forces, high shear rate performance and particle interaction in microscope. A T-microchannel design is numerically analysed by means of computational fluid dynamics (CFD) to investigate the effectiveness of blood separation based on the bifurcation law and other bio-physical effects. The simulation shows that the device can separate blood cells from plasma.
Resumo:
The separation of red blood cells from plasma flowing in microchannels is possible by bio-physical effects such as an axial migration effect and Zweifach-Fung bifurcation law. In the present study, subchannels are placed alongside a main channel to collect cells and plasma separately. The addition of a constriction in the main microchannel creates a local high shear force region, forcing the cells to migrate and concentrate towards the centre of the channel. The resulting lab-on-a-chip was manufactured using biocompatible materials. Purity efficiency was measured for mussel and human blood suspensions as different parameters including flow rate and geometries of parent and daughter channels were varied.
Resumo:
This paper presents preliminary studies in electroplating using megasonic agitation to avoid the formation of voids within high aspect ratio microvias that are used for the redistribution of interconnects in high density interconnection technology in printed circuit boards. Through this technique, uniform deposition of metal on the side walls of the vias is possible. High frequency acoustic streaming at megasonic frequencies enables the decrease of the Nernst diffusion layer down to the sub-micron range, allowing thereby conformal electrodeposition in deep grooves. This effect enables the normally convection free liquid near the surface to be agitated. Higher throughput and better control of the material properties of the deposits can be achieved for the manufacturing of embedded interconnections and metal-based MEMS. For optimal filling performance of the microvias, a full design of experiments (DOE) and a multi-physics numerical simulation have been conducted to analyse the influence of megasonic agitation on the plating quality of the microvias. Megasonic based deposition has been found to increase the deposition rate as well as improving the quality of the metal deposits.
Resumo:
Nano-imprint forming (NIF) is among the most attractive manufacturing technologies offering high yield and low-cost fabrication of three-dimensional fine structures and patterns with resolution of few nanometres. Optimising NIF process is critical for achieving high quality products and minimising the risk of commonly observed defects. Using finite element analysis, the effect of various process parameters is evaluated and design rules for safe and reliable NIF fabrication formulated. This work is part of a major UK Grand Challenge project - 3D-Mintegration - for design, simulation, fabrication, assembly and test of next generation 3D-miniaturised systems.
Resumo:
Nano-imprint forming (NIF) as manufacturing technology is ideally placed to enable high resolution, low-cost and high-throughput fabrication of three-dimensional fine structures and the packaging of heterogeneous micro-systems (S.Y. Chou and P.R. Krauss, 1997). This paper details a thermo-mechanical modelling methodology for optimising this process for different materials used in components such as mini-fluidics and bio-chemical systems, optoelectronics, photonics and health usage monitoring systems (HUMS). This work is part of a major UK Grand Challenge project - 3D-Mintegration - which is aiming to develop modelling and design technologies for the next generation of fabrication, assembly and test processes for 3D-miniaturised systems.
Resumo:
Experimental, analytical and simulated data are presented in this article to assess the performance of electrodeposited nickel-iron within a novel solenoid microinductor. A design flowchart highlights the primary design principles when developing a microscale magnetic component for DC-DC power converters. Thermal modeling is used to predict the operational conditions that generate undesirable thermal generation within the component. Operating at 0.5MHz, the microinductor achieves an efficiency and power density of 78% and 7.8 W/cm3, respectively.
Resumo:
Dual-section variable frequency microwave systems enable rapid, controllable heating of materials within an individual surface mount component in a chip-on=board assembly. The ability to process devices individually allows components with disparate processing requirements to be mounted on the same assembly. The temperature profile induced by the microwave system can be specifically tailored to the needs of the component, allowing optimisation and degree of cure whilst minimising thermomechanical stresses. This paper presents a review of dual-section microwave technology and its application to curing of thermosetting polymer materials in microelectronics applications. Curing processes using both conventional and microwave technologies are assessed and compared. Results indicate that dual-section microwave systems are able to cure individual surface mount packages in a significantly shorter time, at the expense of an increase in thermomechanical stresses and a greater variation in degree of cure.
Resumo:
In this paper we propose an agitation method based on megasonic acoustic streaming to overcome the limitations in plating rate and uniformity of the metal deposits during the electroplating process. Megasonic agitation at a frequency of 1 MHz allows the reduction of the thickness of the Nernst diffusion layer to less than 600 nm. Two applications that demonstrate the benefits of megasonic acoustic streaming are presented: the formation of uniform ultra-fine pitch flip-chip bumps and the metallisation of high aspect ratio microvias. For the latter application, a multi-physics based numerical simulation is implemented to describe the hydrodynamics introduced by the acoustic waves as they travel inside the deep microvias.
Resumo:
Electrodeposition is a widely used technique for the fabrication of high aspect ratio microstructures. In recent years, much research has been focused within this area aiming to understand the physics behind the filling of high aspect ratio vias and trenches on substrates and in particular how they can be made without the formation of voids in the deposited material. This paper reports on the fundamental work towards the advancement of numerical algorithms that can predict the electrodeposition process in micron scaled features. Two different numerical approaches have been developed, which capture the motion of the deposition interface and 2-D simulations are presented for both methods under two deposition regimes: those where surface kinetics is governed by Ohm’s law and the Butler–Volmer equation, respectively. In the last part of this paper the modelling of acoustic forces and their subsequent impact on the deposition profile through convection is examined.
Resumo:
This paper presents an analysis of biofluid behavior in a T-shaped microchannel device and a design optimization for improved biofluid performance in terms of particle liquid separation. The biofluid is modeled with single phase shear rate non-Newtonian flow with blood property. The separation of red blood cell from plasma is evident based on biofluid distribution in the microchannels against various relevant effects and findings, including Zweifach-Fung bifurcation law, Fahraeus effect, Fahraeus-Lindqvist effect and cell free phenomenon. The modeling with the initial device shows that this T-microchannel device can separate red blood cell from plasma but the separation efficiency among different bifurcations varies largely. In accordance with the imbalanced performance, a design optimization is conducted. This includes implementing a series of simulations to investigate the effect of the lengths of the main and branch channels to biofluid behavior and searching an improved design with optimal separation performance. It is found that changing relative lengths of branch channels is effective to both uniformity of flow rate ratio among bifurcations and reduction of difference of the flow velocities between the branch channels, whereas extending the length of the main channel from bifurcation region is only effective for uniformity of flow rate ratio.
Resumo:
Biofluid behaviour in microchannel systems is investigated in this paper through the modelling of a microfluidic biochip developed for the separation of blood plasma. Based on particular assumptions, the effects of some mechanical features of the microchannels on behaviour of the biofluid are explored. These include microchannel, constriction, bending channel, bifurcation as well as channel length ratio between the main and side channels. The key characteristics and effects of the microfluidic dynamics are discussed in terms of separation efficiency of the red blood cells with respect to the rest of the medium. The effects include the Fahraeus and Fahraeus-Lindqvist effects, the Zweifach-Fung bifurcation law, the cell-free layer phenomenon. The characteristics of the microfluid dynamics include the properties of the laminar flow as well as particle lateral or spinning trajectories. In this paper the fluid is modelled as a single-phase flow assuming either Newtonian or Non-Newtonian behaviours to investigate the effect of the viscosity on flow and separation efficiency. It is found that, for a flow rate controlled Newtonian flow system, viscosity and outlet pressure have little effect on velocity distribution. When the fluid is assumed to be Non-Newtonian more fluid is separated than observed in the Newtonian case, leading to reduction of the flow rate ratio between the main and side channels as well as the system pressure as a whole.