954 resultados para Convolution Operators


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microcirculatory resistance (IMR) is an invasive method for quantitatively assessing the coronary microcirculation status. OBJECTIVES: To examine heart microcirculation after intracoronary injection of mesenchymal stem/stromal cells with the index of microcirculatory resistance. METHODS: Healthy swine were randomized to receive by intracoronary route either 30x106 MSC or the same solution with no cells (1% human albumin/PBS) (placebo). Blinded operators took coronary pressure and flow measurements, prior to intracoronary infusion and at 5 and 30 minutes post-delivery. Coronary flow reserve (CFR) and the IMR were compared between groups. RESULTS: CFR and IMR were done with a variance within the 3 transit time measurements of 6% at rest and 11% at maximal hyperemia. After intracoronary infusion there were no significant differences in CFR. The IMR was significantly higher in MSC-injected animals (at 30 minutes, 14.2U vs. 8.8U, p = 0.02) and intragroup analysis showed a significant increase of 112% from baseline to 30 minutes after cell infusion, although no electrocardiographic changes or clinical deterioration were noted. CONCLUSION: Overall, this study provides definitive evidence of microcirculatory disruption upon intracoronary administration of mesenchymal stem/stromal cells, in a large animal model closely resembling human cardiac physiology, function and anatomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica, Sistemas e Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis submitted in fulfilment of the requirements for the Degree of Master of Science in Computer Science

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nowadays, reducing energy consumption is one of the highest priorities and biggest challenges faced worldwide and in particular in the industrial sector. Given the increasing trend of consumption and the current economical crisis, identifying cost reductions on the most energy-intensive sectors has become one of the main concerns among companies and researchers. Particularly in industrial environments, energy consumption is affected by several factors, namely production factors(e.g. equipments), human (e.g. operators experience), environmental (e.g. temperature), among others, which influence the way of how energy is used across the plant. Therefore, several approaches for identifying consumption causes have been suggested and discussed. However, the existing methods only provide guidelines for energy consumption and have shown difficulties in explaining certain energy consumption patterns due to the lack of structure to incorporate context influence, hence are not able to track down the causes of consumption to a process level, where optimization measures can actually take place. This dissertation proposes a new approach to tackle this issue, by on-line estimation of context-based energy consumption models, which are able to map operating context to consumption patterns. Context identification is performed by regression tree algorithms. Energy consumption estimation is achieved by means of a multi-model architecture using multiple RLS algorithms, locally estimated for each operating context. Lastly, the proposed approach is applied to a real cement plant grinding circuit. Experimental results prove the viability of the overall system, regarding both automatic context identification and energy consumption estimation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: O cancro de mama e o mais frequente diagnoticado a indiv duos do sexo feminino. O conhecimento cientifico e a tecnologia tem permitido a cria ção de muitas e diferentes estrat egias para tratar esta patologia. A Radioterapia (RT) est a entre as diretrizes atuais para a maioria dos tratamentos de cancro de mama. No entanto, a radia ção e como uma arma de dois canos: apesar de tratar, pode ser indutora de neoplasias secund arias. A mama contralateral (CLB) e um orgão susceptivel de absorver doses com o tratamento da outra mama, potenciando o risco de desenvolver um tumor secund ario. Nos departamentos de radioterapia tem sido implementadas novas tecnicas relacionadas com a radia ção, com complexas estrat egias de administra ção da dose e resultados promissores. No entanto, algumas questões precisam de ser devidamente colocadas, tais como: E seguro avançar para tecnicas complexas para obter melhores indices de conformidade nos volumes alvo, em radioterapia de mama? O que acontece aos volumes alvo e aos tecidos saudaveis adjacentes? Quão exata e a administração de dose? Quais são as limitações e vantagens das técnicas e algoritmos atualmente usados? A resposta a estas questões e conseguida recorrendo a m etodos de Monte Carlo para modelar com precisão os diferentes componentes do equipamento produtor de radia ção(alvos, ltros, colimadores, etc), a m de obter uma descri cão apropriada dos campos de radia cão usados, bem como uma representa ção geometrica detalhada e a composição dos materiais que constituem os orgãos e os tecidos envolvidos. Este trabalho visa investigar o impacto de tratar cancro de mama esquerda usando diferentes tecnicas de radioterapia f-IMRT (intensidade modulada por planeamento direto), IMRT por planeamento inverso (IMRT2, usando 2 feixes; IMRT5, com 5 feixes) e DCART (arco conformacional dinamico) e os seus impactos em irradia ção da mama e na irradia ção indesejada dos tecidos saud aveis adjacentes. Dois algoritmos do sistema de planeamento iPlan da BrainLAB foram usados: Pencil Beam Convolution (PBC) e Monte Carlo comercial iMC. Foi ainda usado um modelo de Monte Carlo criado para o acelerador usado (Trilogy da VARIAN Medical Systems), no c odigo EGSnrc MC, para determinar as doses depositadas na mama contralateral. Para atingir este objetivo foi necess ario modelar o novo colimador multi-laminas High- De nition que nunca antes havia sido simulado. O modelo desenvolvido est a agora disponí vel no pacote do c odigo EGSnrc MC do National Research Council Canada (NRC). O acelerador simulado foi validado com medidas realizadas em agua e posteriormente com c alculos realizados no sistema de planeamento (TPS).As distribui ções de dose no volume alvo (PTV) e a dose nos orgãos de risco (OAR) foram comparadas atrav es da an alise de histogramas de dose-volume; an alise estati stica complementar foi realizadas usando o software IBM SPSS v20. Para o algoritmo PBC, todas as tecnicas proporcionaram uma cobertura adequada do PTV. No entanto, foram encontradas diferen cas estatisticamente significativas entre as t ecnicas, no PTV, nos OAR e ainda no padrão da distribui ção de dose pelos tecidos sãos. IMRT5 e DCART contribuem para maior dispersão de doses baixas pelos tecidos normais, mama direita, pulmão direito, cora cão e at e pelo pulmão esquerdo, quando comparados com as tecnicas tangenciais (f-IMRT e IMRT2). No entanto, os planos de IMRT5 melhoram a distribuição de dose no PTV apresentando melhor conformidade e homogeneidade no volume alvo e percentagens de dose mais baixas nos orgãos do mesmo lado. A t ecnica de DCART não apresenta vantagens comparativamente com as restantes t ecnicas investigadas. Foram tamb em identi cadas diferen cas entre os algoritmos de c alculos: em geral, o PBC estimou doses mais elevadas para o PTV, pulmão esquerdo e cora ção, do que os algoritmos de MC. Os algoritmos de MC, entre si, apresentaram resultados semelhantes (com dferen cas at e 2%). Considera-se que o PBC não e preciso na determina ção de dose em meios homog eneos e na região de build-up. Nesse sentido, atualmente na cl nica, a equipa da F sica realiza medi ções para adquirir dados para outro algoritmo de c alculo. Apesar de melhor homogeneidade e conformidade no PTV considera-se que h a um aumento de risco de cancro na mama contralateral quando se utilizam t ecnicas não-tangenciais. Os resultados globais dos estudos apresentados confirmam o excelente poder de previsão com precisão na determinação e c alculo das distribui ções de dose nos orgãos e tecidos das tecnicas de simulação de Monte Carlo usados.---------ABSTRACT:Breast cancer is the most frequent in women. Scienti c knowledge and technology have created many and di erent strategies to treat this pathology. Radiotherapy (RT) is in the actual standard guidelines for most of breast cancer treatments. However, radiation is a two-sword weapon: although it may heal cancer, it may also induce secondary cancer. The contralateral breast (CLB) is a susceptible organ to absorb doses with the treatment of the other breast, being at signi cant risk to develop a secondary tumor. New radiation related techniques, with more complex delivery strategies and promising results are being implemented and used in radiotherapy departments. However some questions have to be properly addressed, such as: Is it safe to move to complex techniques to achieve better conformation in the target volumes, in breast radiotherapy? What happens to the target volumes and surrounding healthy tissues? How accurate is dose delivery? What are the shortcomings and limitations of currently used treatment planning systems (TPS)? The answers to these questions largely rely in the use of Monte Carlo (MC) simulations using state-of-the-art computer programs to accurately model the di erent components of the equipment (target, lters, collimators, etc.) and obtain an adequate description of the radiation elds used, as well as the detailed geometric representation and material composition of organs and tissues. This work aims at investigating the impact of treating left breast cancer using di erent radiation therapy (RT) techniques f-IMRT (forwardly-planned intensity-modulated), inversely-planned IMRT (IMRT2, using 2 beams; IMRT5, using 5 beams) and dynamic conformal arc (DCART) RT and their e ects on the whole-breast irradiation and in the undesirable irradiation of the surrounding healthy tissues. Two algorithms of iPlan BrainLAB TPS were used: Pencil Beam Convolution (PBC)and commercial Monte Carlo (iMC). Furthermore, an accurate Monte Carlo (MC) model of the linear accelerator used (a Trilogy R VARIANR) was done with the EGSnrc MC code, to accurately determine the doses that reach the CLB. For this purpose it was necessary to model the new High De nition multileaf collimator that had never before been simulated. The model developed was then included on the EGSnrc MC package of National Research Council Canada (NRC). The linac was benchmarked with water measurements and later on validated against the TPS calculations. The dose distributions in the planning target volume (PTV) and the dose to the organs at risk (OAR) were compared analyzing dose-volume histograms; further statistical analysis was performed using IBM SPSS v20 software. For PBC, all the techniques provided adequate coverage of the PTV. However, statistically significant dose di erences were observed between the techniques, in the PTV, OAR and also in the pattern of dose distribution spreading into normal tissues. IMRT5 and DCART spread low doses into greater volumes of normal tissue, right breast, right lung, heart and even the left lung than tangential techniques (f-IMRT and IMRT2). However,IMRT5 plans improved distributions for the PTV, exhibiting better conformity and homogeneity in target and reduced high dose percentages in ipsilateral OAR. DCART did not present advantages over any of the techniques investigated. Di erences were also found comparing the calculation algorithms: PBC estimated higher doses for the PTV, ipsilateral lung and heart than the MC algorithms predicted. The MC algorithms presented similar results (within 2% di erences). The PBC algorithm was considered not accurate in determining the dose in heterogeneous media and in build-up regions. Therefore, a major e ort is being done at the clinic to acquire data to move from PBC to another calculation algorithm. Despite better PTV homogeneity and conformity there is an increased risk of CLB cancer development, when using non-tangential techniques. The overall results of the studies performed con rm the outstanding predictive power and accuracy in the assessment and calculation of dose distributions in organs and tissues rendered possible by the utilization and implementation of MC simulation techniques in RT TPS.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Portugal, having responsibilities at European level, needs to ensure compliance with European standards, particularly with regard to the European Security Plan for Critical Infrastructures. National critical infrastructures should be a focus of attention with regard to the management of public risks, since these represent "a set of services that are essential to the functioning of the country and the functioning of the forces that ensure national defense." (Soares, 2008) This contribution on national critical infrastructures (CI) has the essential objective of clarifying the development of the strategy adopted by Portugal in pursuit of the security of these fundamental infrastructures. The goal lies not only through producing a descriptive document, but also carry a brief confrontation between the legal framework related to these subjects and the reality in which the Critical Infrastructure Operators and the National Civil Protection Authority (ANPC) operate. It is intended, in this sense, to understand the development of the project for the national security program of critical infrastructures and what effects of its measures on operators. As for the methodology, we followed a methodological strategy, where we combine the literature with data obtained through semi-structured interviews. Portugal, being a geographically peripheral country and having no record of incidents capable of causing major contingencies in key services for the normal development of society, does not have a structured and regulator plan that substantiates the need for operators responsible for CI to invest in security. This same approach is expected at the State level, believing that even though this theme has be widely explored by international institutions, Portugal has not yet tried to give the attention it deserves. Without the existence of an institution and a regulatory system, CI operators can become less available to comply with the legal framework.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The technological evolution of the past fifty years has provided Humanity the contact with the last frontier of knowledge: space. An unknown world, explored by a small group of nations, which has become crucial to understanding who we are and where we come from. Space assets in recent years have opened the way to a digital society, shaped by the rapid exchange of information, whose means are mostly in space. A place of fascination and curiosity, restricted to a few people in these decades, which may soon be changing. This essay addresses some legal issues concerning the private exploration of space. Liability on space tourism is the core of this investigation, focusing on the comprehension of the international legal framework and its connection with the states national law. In particular, the study of the main international treaties, the U.S. legal system of space law and the developments in Europe are the fundamental tools of the current analysis, not forgetting the point of view of a possible international harmonization. Besides the needed theoretical context on the evolution of space law and a brief approach of the technical matters of the current aerospace engineering, the goal is to examine the characteristics of international space law and its relation with the new private actors, responsible for providing suborbital flights, operating in a near future. Within these circumstances, given the economic potential of the growing private space industry, it is essential to discuss the legal aspects of a spatial regulation. Being liability, undoubtedly, the emerging issue in the legal debate on this topic, it is important to safeguard the interests of the operators, States and, above all, future space tourists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Currently, Portugal assumes itself as a democratic rule of substantive law State, sustained by a legal system seeking the right balance between the guarantee of fundamental rights and freedoms constitutional foreseen in Portugal’s Fundamental Law and criminal persecution. The architecture of the penal code lies with, roughly speaking, a accusatory basic structure, “deliberately attached to one of the most remarkable achievements of the civilizational democratic progress, and by obedience to the constitutional commandment”, in balance with the official investigation principle, valid both for the purpose of prosecution and trial. Regarding the principle of non self-incrimination - nemo tenetur se ipsum accusare, briefly defined as the defendant’s right of not being obliged to contribute to the self-incrimination, it should be stressed that there isn’t an explicit consecration in the Portuguese Constitution, being commonly accepted in an implicit constitutional prediction and deriving from other constitutional rights and principles, first and foremost, the meaning and scope of the concept of democratic rule of Law State, embedded in the Fundamental Law, and in the guidelines of the constitutional principles of human person dignity, freedom of action and the presumption of innocence. In any case, about the (in) applicability of the principle of the prohibition of self-incrimination to the Criminal Police Bodies in the trial hearing in Court, and sharing an idea of Guedes Valente, the truth is that the exercise of criminal action must tread a transparent path and non-compliant with methods to obtain evidence that violate the law, the public order or in violation of democratic principles and loyalty (Guedes Valente, 2013, p. 484). Within the framework of the penal process relating to the trial, which is assumed as the true phase of the process, the witness represents a relevant figure for the administration of criminal justice, for the testimonial proof is, in the idea of Othmar Jauernig, the worst proof of evidence, but also being the most frequent (Jauernig, 1998, p. 289). As coadjutant of the Public Prosecutor and, in specific cases, the investigating judge, the Criminal Police Bodies are invested with high responsibility, being "the arms and eyes of Judicial Authorities in pursuing the criminal investigation..." which has as ultimate goal the fulfillment of the Law pursuing the defense of society" (Guedes Valente, 2013, p. 485). It is in this context and as a witness that, throughout operational career, the Criminal Police Bodies are required to be at the trial hearing and clarify the Court with its view about the facts relating to occurrences of criminal context, thus contributing very significantly and, in some cases, decisively for the proper administration of the portuguese criminal justice. With regards to the intervention of Criminal Police Bodies in the trial hearing in Court, it’s important that they pay attention to a set of standards concerning the preparation of the testimony, the very provision of the testimony and, also, to its conclusion. Be emphasized that these guidelines may become crucial for the quality of the police testimony at the trial hearing, thus leading to an improvement of the enforcement of justice system. In this vein, while preparing the testimony, the Criminal Police Bodies must present itself in court with proper clothing, to read before and carefully the case files, to debate the facts being judged with other Criminal Police Bodies and prepare potential questions. Later, while giving his testimony during the trial, the Criminal Police Bodies must, summing up, to take the oath in a convincing manner, to feel comfortable, to start well by convincingly answering the first question, keep an attitude of serenity, to adopt an attitude of collaboration, to avoid the reading of documents, to demonstrate deference and seriousness before the judicial operators, to use simple and objective language, to adopt a fluent speech, to use nonverbal language correctly, to avoid spontaneity responding only to what is asked, to report only the truth, to avoid hesitations and contradictions, to be impartial and to maintain eye contact with the judge. Finally, at the conclusion of the testimony, the Criminal Police Bodies should rise in a smooth manner, avoiding to show relief, resentment or satisfaction, leaving a credible and professional image and, without much formality, requesting the judge permission to leave the courtroom. As final note, it’s important to stress that "The intervention of the Police Criminal Bodies in the trial hearing in Court” encloses itself on a theme of crucial importance not only for members of the Police and Security Forces, who must welcome this subject with the utmost seriousness and professionalism, but also for the proper administration of the criminal justice system in Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction Despite the great advances in serological testing for transfusion-transmitted infections, the selection of blood donors by blood bank operators remains the only way to avoid transmission within the testing window period. Part of this selection is the self-exclusion form, on which the donors can exclude their blood from donation without any explanation. This study assessed the clinical and epidemiological characteristics related to positivity for viral hepatitis and to the use of the confidential self-exclusion (CSE) form. Methods This transversal study analyzed the data collected from blood donors' files in a hospital in Southern Brazil. Univariate and multivariate analyses identified the clinical and epidemiological variables related to positive serologies of viral hepatitis and to whether the donor was self-excluded. Results Of the 3,180 donors included in this study, 0.1% tested positive for HBsAg, 2.1% for anti-HBc, and 0.9% for anti-HCV. When the 93 donors with positive serologies for viral hepatitis were compared with those who were negative, a greater proportion of the positive serology group was found to have had a history of blood transfusions (OR=4.908; 95%CI=1.628 - 14.799; p<0.01), had repeatedly donated (OR=2.147; 95%CI=1.236 - 3.729; p<0.01), and used the CSE form for self-exclusion (OR=7.139; 95%CI=2.045 - 24.923; p<0.01). No variables were independently associated with self-exclusion. Conclusions A history of blood transfusion, repeated donations, and self-exclusion are factors that should be considered during viral hepatitis screenings in blood banks.