854 resultados para Transmission Line Method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the research on the transmission characteristic of slow-light-mode in the photonic crystal line-defect waveguide bends on SOL After optimizing the structure parameters in the vicinity of the bends, the normalized transmission efficiency of slow-light-mode through the photonic crystal 60 degree and 120 degree waveguide bends are as high as 80% and 60% respectively, which are 10 times higher than that in the undeformed case. To slow down light further, we design novel coupled cavity waveguide bend structures with high quality-factor. High normalized transmission efficiency of 75% and low group velocity of c/170 ( c is the light velocity in vacuum) are realized. These results are beneficial to enhance the slow light effect of photonic crystal structures and improve the miniaturization and integration of photonic crystal slow light devices.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Butt joint line-defect-waveguide microlasers are demonstrated on photonic crystal slabs with airholes in a triangular lattice. Such microlaser is designed to increase the output power from the waveguide edge directly. The output power is remarkably enhanced to 214 times higher by introducing chirped structure in the output waveguide. The lasing mode operates in the linear dispersion region of the output waveguide so that the absorption loss due to the band-edge effect is reduced. The laser resonance is illustrated theoretically using the finite difference time domain method. A practical high power efficiency of 20% is obtained in this microlaser. (C) 2008 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigated the transmission probability of a single electron transmission through a quantum ring device based on the single-band effective mass approximation method and transfer matrix theory. The time-dependent Schrodinger equation is applied on a Gaussian wave packet passing through the quantum ring system. The electron tunneling resonance peaks split when the electron transmits through a double quantum ring. The splitting energy increases as the distance between the two quantum rings decreases. We studied the tunneling time through the single electron transmission quantum ring from the temporal evolution of the Gaussian wave packet. The electron probability density is sensitive to the thickness of the barrier between the two quantum rings. (C) 2008 American Institute of Physics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for fabrication of long-wavelength narrow line-width InGaAs resonant cavity enhanced (RCE) photodetectors in a silicon substrate operating at the wavelength range of 1.3-1.6 mu m has been developed. A full width at half maximum (FWHM) of 0.7 nm and a peak responsivity of 0. 16 A/W at the resonance wavelength of 1.55 mu m have been accomplished by using a thick InP layer as part of the resonant cavity. The effects of roughness and tilt of the InP layer surface, and its free carrier absorption, as well as the thickness deviation of the mirror pair on the resonance wavelength shift and the peak quantum efficiency of the RCE photodetectors are analyzed in detail, and approaches for minimizing them toward superior performance are suggested. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transmission of an electromagnetic wave from a heavily doped n-type GaAs film is studied theoretically. The calculations are performed using the two-dimensional finite-different time-domain method. From the calculations, we find the extraordinary transmission of p-polarized waves through the film with subwavelength grooves on both surfaces at mid-infrared frequencies. By determining a set of groove parameters, we optimize the transmission to as high as 55.2%. We ascribe this extraordinary transmission to the coupling of the surface-plasmon polariton modes and waveguide modes. Such an enhanced transmission device can be useful for mid-infrared wave filters, emitters, and monitors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new double-layer grating template is designed to reduce the out-of-band loss as much as 1.8dB when the loss of LP03 reaches 10.2 dB. Meanwhile, we propose a method to remove the sidelobes in the transmission spectra by the adjustment of the thickness of pressure plates. The plate-thickness-induced shift of resonant wavelength and the attenuation of loss peak intensity when removing sidelobes can be modified by the fibre distance and contact point on the pressure plates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A small-size optical interleaver based on directional coupler in a 2D photonic crystal slab with triangular lattice of air holes is designed and theoretically simulated using plane wave expansion and finite-difference time-domain method. The interleaver is formed by two parallel and identical photonic crystal slab waveguides which are separated by three rows of air holes. The coupling region is designed below the light line to avoid vertical radiation. The simulated results show that the coupling coefficient is increased and the final length of the interleaver is decreased by enlarging the radius of the middle row of air holes. The transmission properties are analyzed after the interleaver's structure is optimized, and around 100 GHz channel spacing can be got when the length of the interleaver is chosen as 40.5 mu m. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Straight single-line defect optical waveguides in photonic crystal slabs are designed by the plane wave expansion method and fabricated into silicon-on-insulator (SOI) wafer by 248-nm deep UV lithography. We present an efficient way to measure the light transmission spectrum of the photonic crystal waveguide (PhC WG) at given polarization states. By employing the Mueller/Stokes method, we measure and analyse the light propagation properties of the PhC WG at different polarized states. It is shown that experimental results are in agreement with the simulation results of the three-dimensional finite-difference-time-domain method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Details of the design, fabrication and testing of a strained InGaAsP/InGaAsP multiple quantum well (MQW) electroabsorption modulator (EAM) monolithically integrated with a DFB laser by ultra-low-pressure selective area growth (SAG) are presented. The method greatly simplifies the integration process. A study of the controllability of band-gap energy by SAG has been performed. After being completely packaged in a seven-pin butterfly compact module, the device successfully performs 10 Gb s(-1) nonreturn to zero (NRZ) operation on uncompensated transmission span >53 km in a standard fibre with a 8.7 dB dynamic extinction ratio. A receiver sensitivity of -18.9 dBm at a bit error rate (BER) of 10(-10) is confirmed. 10 GHz short pulse trains with 15.3 ps pulsewidth have also been generated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A one-to-two splitter for self-collimated beams in photonic crystal (PC) is designed by inserting one row of line defects. Finite-difference time-domain (FDTD) method is used to simulate the light propagation process. Our systematical studies show that the splitting ratio is a function of the airholes size of the line defect radius, and stays fairly constant as a function of frequency. Furthermore, it is shown the numerical results can be analyzed by coupled-mode theory. (C) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a novel light source of strained InGaAsP/InGaAsP MQW EAM monolithically integrated with DFB laser is fabricated by ultra-low-pressure (22 x 10(2) Pa) selective area growth ( SAG) MOCVD technique. Superior device performances have been obtained, sue h as low threshold current of 19 mA, output light power of about 7 mW, and over 16 dB extinction ratio at 5 V applied voltage when coupled into a single mode fiber. Over 10 GHz 3 dB bandwidth in EAM part is developed with a driving voltage of 3 V. After the chip is packaged into a 7-pin butterfly compact module, 10-Gb/s NRZ transmission experiments are successfully performed in standard fiber. A clearly-open eye diagram is achieved in the module output with over 8.3 dB dynamic extinction ratio. Power penalty less than 1.5 dB has been obtained after transmission through 53.3 km of standard fiber, which demonstrates that high-speed, low chirp EAM/DFB integrated light source can be obtained by ultra-low-pressure (22 x 102 Pa) SAG method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a novel method for determining semiconductor parameters such as diffusion length L, lifetime tau and surface recombination velocity S of minority carriers by employing scanning electron microscopy (SEM). This new method is applicable to both electron beam induced current (EBIC and surface electron beam induced voltage (SEBIV) modes in SEM. The quantitative descriptions for EBIC and SEBIV signals are derived. The parameters L, S and tau can be directly extracted from the expressions for EBIC or SEBIV signals and their relaxation characteristics in experiment. As an example, the values of L, S and tau for n-p junction and p-Si crystal are determined by using the novel method in EBIC or SEBIV mode. The carrier diffusion length of a p-Si crystal is determined to be 8.74 mum in SEBIV mode. It is very close to the normal diffusion length of 7.41 mum of this sample. The novel method is proved to be very helpful for the quantitative characterization of semiconductor materials and devices. Especially, the SEBIV mode in SEM shows great potential for investigating semiconductor structures nondestructively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of phase uncertainty arising in calibration of the test fixtures is investigated in this paper, It is shown that the problem exists no matter what kinds of calibration standards are used. It is also found that there is no need to determine the individual S-parameters of the test fixtures. In order to eliminate the problem of phase uncertainty, three different precise (known) reflection standards or one known reflection standard plus one known transmission standard should be used to calibrate symmetrical test fixtures. For the asymmetrical cases, three known standards, including at least one transmission standard, should be used. The thru-open-match (TOM) and thru-short-match (TSM) techniques are the simplest methods, and they have no bandwidth limitation. When the standards are imprecise (unknown), it is recommended to use any suitable technique, such as the thru-reflect-line, line-reflect-line, thru-short-delay, thru-open-delay,line-reflect-match, line-reflect-reflect-match, or multiline methods, to accurately determine the values of the required calibration terms and, in addition, to use the TOM or TSM method with the same imprecise standards to resolve the phase uncertainty.