988 resultados para Static volumetric method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of the Etest and the reference broth macrodilution susceptibility test for fluconazole, ketoconazole, itraconazole and amphotericin B was performed with 59 of Candida species isolated from the oral cavities of AIDS patients. The Etest method was performed according to the manufacturer's instructions, and the reference method was performed according to National Committee for Clinical Laboratory Standards document M27-A guidelines. Our data showed that there was a good correlation between the MICs obtained by the Etest and broth dilution methods. When only the MIC results at ± 2 dilutions for both methods were considered, the agreement rates were 90.4% for itraconazole, ketoconazole and amphotericin B and 84.6% for fluconazole of the C. albicans tested. In contrast, to the reference method, the Etest method classified as susceptible three fluconazole-resistant isolates and one itraconazole-resistant isolate, representing four very major errors. These results indicate that Etest could be considered useful for antifungal sensitivity evaluation of yeasts in clinical laboratories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os agentes quelantes, como é o caso do EDTA, são utilizados numa ampla variedade de indústrias como a indústria têxtil, da pasta de papel, alimentar, de cosméticos ou de detergentes. Contudo, os agentes complexantes sintéticos, habitualmente usados, não são biodegradáveis, pelo que a sua acumulação no meio ambiente constitui motivo de preocupação. Deste modo, existe um interesse crescente na substituição destes compostos por compostos similares biodegradáveis sendo, deste modo, ambientalmente amigáveis. Alguns microrganismos são capazes de produzir moléculas com capacidade de captar metais. Um desses exemplos são os sideróforos: compostos produzidos por bactérias, fungos e plantas gramíneas, com capacidade de formar quelatos muito estáveis com o ferro. A presente dissertação teve como objetivo estudar o efeito de diferentes condições culturais e nutricionais na produção de sideróforo pela bactéria Bacillus megaterium. A avaliação da produção de sideróforo, utilizando o método colorimétrico Chrome Azurol S (CAS), durante o crescimento da bactéria, em meio de cultura deficiente em ferro, na presença de 5 ou de 20 g/L de glucose, mostrou que o início da sua produção ocorre, durante a fase exponencial de crescimento, não está relacionada com a esporulação e não é afetada pela concentração de glucose. Contudo, o crescimento da bactéria na presença de diferentes fontes de carbono (glicerol, frutose, galactose, glucose, manose, lactose, maltose ou sacarose) evidenciou que a produção de sideróforo é afetada pelo tipo de fonte de carbono. O crescimento na presença de glicerol promoveu a maior produção de sideróforo; efeito inverso foi observado na presença de manose. A bactéria B. megaterium, quando crescida na presença de frutose, galactose, glucose, lactose, maltose ou sacarose, produziu concentrações similares de sideróforo. O aumento da concentração de arginina, no meio de cultura, não aumentou a produção de sideróforo. A agitação apresentou um efeito positivo na produção de sideróforo; o crescimento em condições estáticas atrasou e diminuiu a produção de sideróforo. Em conclusão, o glicerol parece constituir uma fonte de carbono alternativa, aos monossacáridos e dissacáridos, para a produção de sideróforo. A agitação apresenta um efeito positivo na produção de sideróforo pela bactéria B. megaterium ATCC 19213.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Para o projeto de qualquer estrutura existente (edifícios, pontes, veículos, máquinas, etc.) é necessário conhecer as condições de carga, geometria e comportamento de todas as suas partes, assim como respeitar as normativas em vigor nos países nos quais a estrutura será aplicada. A primeira parte de qualquer projeto nesta área passa pela fase da análise estrutural, onde são calculadas todas as interações e efeitos de cargas sobre as estruturas físicas e os seus componentes de maneira a verificar a aptidão da estrutura para o seu uso. Inicialmente parte-se de uma estrutura de geometria simplificada, pondo de parte os elementos físicos irrelevantes (elementos de fixação, revestimentos, etc.) de maneira a simplificar o cálculo de estruturas complexas e, em função dos resultados obtidos da análise estrutural, melhorar a estrutura se necessário. A análise por elementos finitos é a ferramenta principal durante esta primeira fase do projeto. E atualmente, devido às exigências do mercado, é imprescindível o suporte computorizado de maneira a agilizar esta fase do projeto. Existe para esta finalidade uma vasta gama de programas que permitem realizar tarefas que passam pelo desenho de estruturas, análise estática de cargas, análise dinâmica e vibrações, visualização do comportamento físico (deformações) em tempo real, que permitem a otimização da estrutura em análise. Porém, estes programas demostram uma certa complexidade durante a introdução dos parâmetros, levando muitas vezes a resultados errados. Assim sendo, é essencial para o projetista ter uma ferramenta fiável e simples de usar que possa ser usada para fins de projeto de estruturas e otimização. Sobre esta base nasce este projeto tese onde se elaborou um programa com interface gráfica no ambiente Matlab® para a análise de estruturas por elementos finitos, com elementos do tipo Barra e Viga, quer em 2D ou 3D. Este programa permite definir a estrutura por meio de coordenadas, introdução de forma rápida e clara, propriedades mecânicas dos elementos, condições fronteira e cargas a aplicar. Como resultados devolve ao utilizador as reações, deformações e distribuição de tensões nos elementos quer em forma tabular quer em representação gráfica sobre a estrutura em análise. Existe ainda a possibilidade de importação de dados e exportação dos resultados em ficheiros XLS e XLSX, de maneira a facilitar a gestão de informação. Foram realizados diferentes testes e análises de estruturas de forma a validar os resultados do programa e a sua integridade. Os resultados foram todos satisfatórios e convergem para os resultados de outros programas, publicados em livros, e para cálculo a mão feitos pelo autor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total antioxidant capacity (TAC) of 28 flavoured water samples was assessed by ferric reducing antioxidant potential (FRAP), oxygen radical absorbance capacity (ORAC), trolox equivalent antioxidant capacity (TEAC) and total reactive antioxidant potential (TRAP) methods. It was observed that flavoured waters had higher antioxidant activity than the corresponding natural ones. The observed differences were attributed to flavours, juice and vitamins. Generally, higher TAC contents were obtained on lemon waters and lower values on guava and raspberry flavoured waters. Lower and higher TACs were obtained by TRAP and ORAC method, respectively. Statistical analysis suggested that vitamins and flavours increased the antioxidant content of the commercial waters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molecular imprinting is a useful technique for the preparation of functional materials with molecular recognition properties. A Biomimetic Sensor Potentiometric System was developed for assessment of doxycycline (DOX) antibiotic. The molecularly imprinted polymer (MIP) was synthesized by using doxycycline as a template molecule, methacrylic acid (MAA) and/or acrylamide (AA) as a functional monomer and ethylene glycol dimethacrylat (EGDMA) as a cross-linking agent. The sensing elements were fabricated by the inclusion of DOX imprinted polymers in polyvinyl chloride (PVC) matrix. The sensors showed a high selectivity and a sensitive response to the template in aqueous system. Electrochemical evaluation of these sensors under static (batch) mode of operation reveals near-Nernstian response. MIP/MAA membrane sensor was incorporated in flow-through cells and used as detectors for flow injection analysis (FIA) of DOX. The method has the requisite accuracy, sensitivity and precision to assay DOX in tablets and biological fluids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local fractional Poisson equations in two independent variables that appear in mathematical physics involving the local fractional derivatives are investigated in this paper. The approximate solutions with the nondifferentiable functions are obtained by using the local fractional variational iteration method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryptococcus neoformans detection was optimized using PCR technique with the objective of application in the clinical laboratory diagnosis. The amplification area was ITS and 5,6S which encodes the ribosomal RNA (rRNA). A total of 72 cerebrospinal fluid (CSF) samples were used, obtained from cases with and without AIDS. The patients had cryptococcal meningitis (n = 56) and meningitis caused by other agents (n = 16). The results demonstrated that PCR test had the highest sensitivity rates, superior to culture (85.7%) and to India ink test (76.8%). PCR was found to be sensitive in detecting 1 cell/mL and highly specific since it did not amplify other fungal DNA. The comparative analysis of the methods showed that PCR is more sensitive and specific and is applicable as an important laboratorial resource for neurocryptococcosis diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation to obtain the Master degree in Electrical Engineering and Computer Science

Relevância:

20.00% 20.00%

Publicador:

Resumo:

13th International Conference on Autonomous Robot Systems (Robotica), 2013, Lisboa

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents an automatic calibration method for a vision based external underwater ground-truth positioning system. These systems are a relevant tool in benchmarking and assessing the quality of research in underwater robotics applications. A stereo vision system can in suitable environments such as test tanks or in clear water conditions provide accurate position with low cost and flexible operation. In this work we present a two step extrinsic camera parameter calibration procedure in order to reduce the setup time and provide accurate results. The proposed method uses a planar homography decomposition in order to determine the relative camera poses and the determination of vanishing points of detected lines in the image to obtain the global pose of the stereo rig in the reference frame. This method was applied to our external vision based ground-truth at the INESC TEC/Robotics test tank. Results are presented in comparison with an precise calibration performed using points obtained from an accurate 3D LIDAR modelling of the environment.