998 resultados para energized shield wire line
Resumo:
The performance of the current sensor in power equipment may become worse affected by the environment. In this paper, based on ICA, we propose a method for on-line verification of the phase difference of the current sensor. However, not all source components are mutually independent in our application. In order to get an exact result, we have proposed a relative likelihood index to choose an optimal result from different runs. The index is based on the maximum likelihood evaluation theory and the independent subspace analysis. The feasibility of our method has been confirmed by experimental results.
Resumo:
Submitted by 阎军 (yanj@red.semi.ac.cn) on 2010-06-04T07:40:23Z No. of bitstreams: 1 Reconfigurable Optical Add-Drop Multiplexer Based on Silicon Photonic Wire Waveguide.pdf: 416355 bytes, checksum: 5b80992194ba9fa818a011244cec6363 (MD5)
Resumo:
Submitted by 阎军 (yanj@red.semi.ac.cn) on 2010-04-04T06:57:43Z No. of bitstreams: 1 71.pdf: 92858 bytes, checksum: 2a0a4972af8e56b0fced818042dd6dbd (MD5)
Resumo:
Emporiki Bank; Microsoft; Alpha Bank
Resumo:
A three-dimensional analytical solution of the microheater temperature based on heat diffusion equation is developed and compared with experimental results. Dimensionless parameters are introduced to analyze the temperature rise time and the distribution under steady state. To study the microheater temperatures before bubble nucleation, a set of working fluids and microheaters are considered. It is shown that the dimensionless time xi(-)(0) required for the temperature rise from room to 95% of the steady state temperature is about 75, not dependent on working fluids and microheaters. Heat transfer to the surrounding liquid is mainly caused by conduction, not by convection and radiation mechanisms. The microheater length affects the surface temperature uniformity, while its width influences the steady temperatures significantly, yielding the transition from heterogeneous to homogeneous nucleation mechanism from square microheaters to narrow line microheaters.
Resumo:
A theoretical investigation of ballistic electron transport in a quantum wire with soft wall confinement is presented. A general method of the electron transmission calculation is proposed for structures with complicated geometries. The effects of the lateral guiding potential on ballistic transport are investigated using three soft wall confinement models and the results are compared with those obtained from the hard wall confinement approximation. It is shown that the calculated transmission coefficients are notably dependent on the lateral confining potential especially when the incident electron energy is larger than the energy of the second transverse mode. It is found that the transmission profile obtained from soft wall confinement models exhibits simpler resonance structures than that obtained from the hard wall confinement approximation. Our results suggest that only in the single-channel regime the hard wall confinement approximation can give reasonable results.
HIGH-EFFICIENCY TOP SURFACE-EMITTING LASERS FABRICATED BY 4 IMPLANTATION USING TUNGSTEN WIRE AS MASK
Resumo:
We report the results of a high efficiency room temperature continuous wave (cw) vertical-cavity surface-emitting laser. The structure is obtained by four deep H+ implantation using tungsten wires as the mask. The fabrication process is the simplest ever reported in vertical-cavity surface-emitting laser fabrication. The largest differential quantum efficiency of 65% and maximum cw light output power over 4 mW have been achieved for the 15X15 mu m(2) device. (C) 1995 American Institute of Physics.
Resumo:
GaAs/AIGaAs two-dimensional quantum-well wire laser arrays fabricated by metal-organic chemical vapour deposition on nonplanar substrates have realised a linear light pulse output Fewer of over 100mW. This is the highest figure reported to date for all kinds of quantum-well wire lasers.
Resumo:
Different chemical mechanical polishing (CMP) slurries are used to obtain single-damascene Cu-wires with different surface fluctuations as well as pre-existing surface-defects in wires with rougher surfaces. The presence of such pre-existing defects strongly increases the rate of early failures to almost 100%, reduces electromigration lifetime rapidly to the level of early failures, and changes the multimodal failure distribution into monomodal. The activation energy (0. 74±0.02eV) for the failure mechanism associated with these pre-existing defects confirms a dominant surface diffusion. It shows how a weakest link approximation analysis can he applied to a single wire by dividing the wire into relevant segments and assigning different failure mechanisms to the various segments. The analysis confirms that, although surface-defects are not the fastest early failure mechanism, the ten times higher surface-defectdensity in the rougher wires is responsible for the observed high early-failure rate and unreliable performance.
Resumo:
于2010-11-23批量导入