929 resultados para MBF-apparatus
Resumo:
A simple and inexpensive device to automate a water distilling apparatus is shown. It is composed by a magnetic floater placed in the water reservoir and a level control unit, which acts over the heating element circuit. In order to provide water saving, an electromagnetic valve is inserted in the water supply inlet. Some suggestions for the adaptation to other types of equipment are also offered.
Resumo:
This article describes the progress of a group of investigation on thermochemistry, which started in 1972. A homemade calorimeter was employed to provide quantitative support to the information on interative effect between lanthanide cations and halides or pseudohalides, in non-aqueous solvents, previously derived from conductometric titrations. However, the features of this instrument were not able to detect the thermal effects. Therefore, the great input to the group came from the acquisition of an LKB commercial apparatus, by the University in 1975. Considering the historical development of the coordination chemistry in Brazil, which was previously dedicated to strutural features of adducts, without focusing the energetic envolved in any coordinationcompound. Since starting the thermochemistry study, numerous masters and doctoral thesis covering more than a hundred adducts and a reasonable number of chelates, were presented systematizing data in order to understand the behavior of this kind of coordination compounds (C. Airoldi and A. P. Chagas, Coord. Chem. Rev. 1992, 119, 29). This knowledge enabled an extension of the study to include some heterogeneous systems formed by natural or synthetic materials like immobilized silica gel, lamellar phosphate, phosphonate or sulphate compounds, clays, polysaccharides, chrysotile, soils, etc. Many students are now engaged as staff members in Universities, Research Instituitions or other private institutions, developing many activities. Due to a multiplying effect on the formation of researchers, the group is now reaching the fourth generation.
Resumo:
This paper presents the design of a simple apparatus that periodically switches off both working and auxiliary electrodes short-circuiting them for a couple of seconds. Depolarization takes place and the initial current is re-established.
Resumo:
Reproductive morphology of the Mediterranean red alga Kallymenia patens is described for the first time, confirming its position in the genus. K. patens is characterized by a non-procarpic female reproductive apparatus, carpogonial branch systems consisting of supporting cells bearing both three-celled carpogonial branches and subsidiary cells that lack a hypogynous cell and carpogonium; fusion cells develop numerous connecting filaments, and tetrasporangia are scattered over the thallus and are probably cruciately divided. Old fertile spathulate specimens of K. patens are morphologically similar to K. spathulata, but they can be distinguished by the length of spathulated proliferations (up to 0.6 cm and 6 cm, respectively), the length of inner cortical cells (up to 70 and 30 μm, respectively), and the gonimoblast location (in proliferations from the perennial part of the blade and over all the thallus surface, respectively)
Resumo:
A simple and inexpensive time-of-flight mass spectrometer, dedicated to the study of gas-phase ionization processes induced by high energy electrons (0.5 - 3.0 keV), is described. The spectrometer design is based on the Wiley-McLaren principle, with a total length of about 18 cm. As a demonstration of the performance of the apparatus, mass spectra for Ar, CH4, CO2, and SF6, obtained at 1 keV electron energy, are presented.
Resumo:
La col·lecció «La Novel·la Estrangera» és constituïda per trenta-vuit títols d’aparició quinzenal en una primera etapa i setmanal en una segona i última. De dimensions reduïdes (entre 40 i 80 pàgines), no va arribar, amb alguna excepció, a publicar novel·les, sinó tan sols narrativa curta. Pel format, el disseny, el contingut, el preu i la forma de distribució i venda, la col·lecció anava destinada a un públic ampli. La selecció d’autors traduïts, eclèctica, respon també a la voluntat d’arribar a un sector extens de lectors. Iniciativa d’escriptors joves, la trajectòria de la col·lecció estigué marcada per la precarietat de l’estructura editorial adoptada, cosa que la va condemnar a la fallida.
Resumo:
We intend to divulge an easy experiment that permits the determination of molar masses of various compounds by cryoscopy. The major advantage of this is the use of the tert-butyl alcohol as a solvent, which requires simple apparatus and easy procedures. The melting point of this alcohol is around 25 ºC, which makes it easy to freeze and then melt the solutions. This solvent has a high cryoscopic constant and is miscible with both polar and non-polar compounds. The molar masses of acetone, water, chloroform, dichloro-methane, ethanol, hexane, carbon tetrachloride and toluene were determined. The results were good except for water. Even though there are reliable techniques of molar mass determination nowadays, this method is still frequently taught in undergraduate courses.
Resumo:
The degradation of the catalytic filaments is the main factor limiting the industrial implementation of the hot wire chemical vapor deposition (HWCVD) technique. Up to now, no solution has been found to protect the catalytic filaments used in HWCVD without compromising their catalytic activity. Probably, the definitive solution relies on the automatic replacement of the catalytic filaments. In this work, the results of the validation tests of a new apparatus for the automatic replacement of the catalytic filaments are reported. The functionalities of the different parts have been validated using a 0.2 mm diameter tungsten filament under uc-Si:H deposition conditions.
Resumo:
Seeds Citrus oils (C. sinensis, C. limon and C. reticulata) extraction with hexane in a soxhlet apparatus and through supercritical fluid (CO2) were done. Besides triglycerides, the oils obtained with hexane comprised volatile compounds such as terpenes and fatty alcohols, esters, and aldehydes. However, the oils obtained by extraction with supercritical fluid presented only triglycerides. These results indicate that the extraction using supercritical fluid presents better selectivity. The activity of the oils on the development of the ant symbiotic fungus, Leucoagaricus gongylophorus, showed week activity and the topic insecticide assay showed better activity for the tangerine seed oil.
Resumo:
Streaming potential measurements for the surface charge characterisation of different filter media types and materials were used. The equipment was developed further so that measurements could be taken along the surfaces, and so that tubular membranes could also be measured. The streaming potential proved to be a very useful tool in the charge analysis of both clean and fouled filter media. Adsorption and fouling could be studied, as could flux, as functions of time. A module to determine the membrane potential was also constructed. The results collected from the experiments conducted with these devices were used in the study of the theory of streaming potential as an electrokinetic phenomenon. Several correction factors, which are derived to take into account the surface conductance and the electrokinetic flow in very narrow capillaries, were tested in practice. The surface materials were studied using FTIR and the results compared with those from the streaming potentials. FTIR analysis was also found to be a useful tool in the characterisation of filters, as well as in the fouling studies. Upon examination of the recorded spectra from different depths in a sample it was possible to determine the adsorption sites. The influence of an external electric field on the cross flow microflltration of a binary protein system was investigated using a membrane electroflltration apparatus. The results showed that a significant improvement could be achieved in membrane filtration by using the measured electrochemical properties to help adjust the process conditions.
Resumo:
In the literature survey retention mechanisms, factors effecting retention and microparticles were studied. Also commercial microparticle retention systems and means to measure retention were studied. Optical retention measurement with RPA and Lasentec FBRM was studied. The experimental part contains study of different cationic polyacrylamides, anionic silica, bentonite and new generation micropolymer. In these studies the dosage, dosing order and dosing history were changing factors. The experimental work was done with RPA-apparatus with which, the retention process can be followed in real time. In testing was found that silica yielded better retention, when dosed nontraditionally before the polymer. Also silica was very dependant on the polymer dosage. With bentonite good colloidal retention was achieved with relatively low doses. Unlike silica bentonite was not dependant on polymer dosage. The relation of bentonite and polymer dosage is more defining when high retention is wanted. With 3-component systems using bentonite very high retention was achieved. With silica no improvement in retention was found in 3-component systems compared to dual component systems.
Resumo:
A simple system to measure the magnetic susceptibility of different materials is presented. The system uses an analytical scale with sensitivity on the order of micrograms and a permanent NdBFe magnet, based in the Rankine method. In this apparatus, the sample is placed near to the magnet that is fixed on the scale. Depending on the magnetic properties of the sample, an attractive or repulsive force will appear between the magnet and the magnetizing sample. Measuring this force, registered by the scale as a mass, the magnetic parameters such as: permeability and susceptibility of the sample can be determined. Despite it is simplicity the method is quantitative, precise and easily reproducible in many laboratories, what makes it attractive for teaching experiments.
Resumo:
Nanofiltration performance was studied with effluents from the pulp and paper industry and with model substances. The effect of filtration conditions and membrane properties on nanofiltration flux, retention, and fouling was investigated. Generally, the aim was to determine the parameters that influence nanofiltration efficiency and study how to carry out nanofiltration without fouling by controlling these parameters. The retentions of the nanofiltration membranes studied were considerably higher than those of tight ultrafiltration membranes, and the permeate fluxes obtained were approximately the same as those of tight ultrafiltration membranes. Generally, about 80% retentions of total carbon and conductivity were obtained during the nanofiltration experiments. Depending on the membrane and the filtration conditions, the retentions of monovalent ions (chloride) were between 80 and 95% in the nanofiltrations. An increase in pH improved retentions considerably and also the flux to some degree. An increase in pressure improved retention, whereas an increase in temperature decreased retention if the membrane retained the solute by the solution diffusion mechanism. In this study, more open membranes fouled more than tighter membranes due to higher concentration polarization and plugging of the membrane material. More irreversible fouling was measured for hydrophobic membranes. Electrostatic repulsion between the membrane and the components in the solution reduced fouling but did not completely prevent it with the hydrophobic membranes. Nanofiltration could be carried out without fouling, at least with the laboratory scale apparatus used here when the flux was below the critical flux. Model substances had a strong form of the critical flux, but the effluents had only a weak form of the critical flux. With the effluents, some fouling always occurred immediately when the filtration was started. However, if the flux was below the critical flux, further fouling was not observed. The flow velocity and pH were probably the most important parameters, along with the membrane properties, that influenced the critical flux. Precleaning of the membranes had only a small effect on the critical flux and retentions, but it improved the permeability of the membranes significantly.
Resumo:
A laboratory procedure was devised to recover bromine from waste alkaline aqueous solutions used in the isotopic determination of N-15. The laboratory apparatus comprises two round bottom flasks (1 and 2 L), a dropping funnel, a gas bubbler, a gas regulator and glass fittings. The waste solution is acidified with sulfuric acid forming molecular bromine that is stripped out by a flow of nitrogen gas bubbled through the solution. This gas is then bubbled through a solution of lithium hydroxide generating lithium bromide and lithium hypobromite. The efficiency of bromine recovery was estimated to be 82±2%. This resulting solution was successfully reused in the isotopic determination of N-15. The procedure can recycle most of the bromine used in the laboratory saving resources and preserving the environment. The procedure can be adapted to recover bromine of other laboratory waste streams.
Resumo:
The volatile constituents obtained from a static cryogenic headspace of Caesalpinia echinata Lam. (Leguminosae) showed E-beta-ocimene as the major compound (57.2%), beside other monoterpenes, C6 derivatives like n-hexanal and (E)-2-hexenal and nitrogen compounds such as indole and methyl anthranilate. From the essential oil of the leaves obtained by hydrodistillation in a Clevenger apparatus, (E)-3-hexen-1-ol was identified as the major constituent while phenolic compounds were the most representative class of secondary metabolites.