957 resultados para Voltage Total Harmonic Distortion
Resumo:
\alpha T3-1 cells showed a slope resistance of 1.8 G\omega. The cell membrane surface was not smooth and a scanning electron micrograph showed a complex structure with blebs and microvilli like projections. The cells showed spontaneous fluctuations at zero current resting membrane potential and hyperpolarization increased the amplitude of membrane potential fluctuations. The amplitude of membrane potential fluctuations at hyperpolarized membrane potential was attenuated on application of TTX to the bath solution. The potential at which half steady state inactivation of isolated sodium current occurred, was at a very hyperpolarized potential (-95.4 mV). The study presented in this paper shows that the voltage gated sodium channels contribute to the increase in the amplitude of electrical noise with hyperpolarization in \alpha T3-1 cells.
Resumo:
We obtained the images of the eastern part of the solar corona in the Fe xiv 530.3 nm (green) and Fe x 637.4 nm (red) coronal emission lines during the total solar eclipse of 29 March 2006 at Manavgat, Antalya, Turkey. The images were obtained using a 35 cm Meade telescope equipped with a Peltier-cooled 2k x 2k CCD and 0.3 nm pass-band interference filters at the rates of 2.95 s (exposure times of 100 ms) and 2.0 s (exposure times of 300 ms) in the Fe xiv and Fe x emission lines,respectively. The analysis of the data indicates intensity variations at some locations with period of strongest power around 27 s for the green line and 20 s for the red line. These results confirm earlier findings of variations in the continuum intensity with periods in the range of 5 to 56 s by Singh et al. (Solar Phys. 170, 235, 1997). The wavelet analysis has been used to identify significant intensity oscillations at all pixels within our field of view. Significant oscillations with high probability estimates were detected for some locations only. These locations seem to follow the boundary of an active region and in the neighborhood, rather than within the loops themselves. These intensity oscillations may be caused by fast magneto-sonic waves in the solar corona and partly account for heating of the plasma in the corona.
Resumo:
Structural, microstructural, and dielectric studies have been carried out on Pr-modified PbTiO3. A comparative analysis with La-modified PbTiO3 suggests that for chemical modification by same amount, the Pr-modified system has larger tetragonal strain and Curie point. No clear feature of relaxor ferroelectric state is observed for Pr concentration as high as x=0.35, suggesting that Pr modification is less effective, as compared to La-modification, in inducing a relaxor ferroelectric state. Results suggest that inspite of increased chemical disorder, Pr modification partly tends to restore the ferroelectric distortion of the lattice through partial occupancy of the Pr4+ ions on the Ti4+ sites.
Resumo:
The first aim of the current study was to evaluate the survival of total hip arthroplasty (THA) in patients aged 55 years and older on a nation-wide level. The second aim was to evaluate, on a nation wide-basis, the geographical variation of the incidence of primary THA for primary OA and also to identify those variables that are possibly associated with this variation. The third aim was to evaluate the effects of hospital volume: on the length of stay, on the numbers of re-admissions and on the numbers of complications of THR on population-based level in Finland. The survival of implants was analysed based on data from the Finnish Arthroplasty Register. The incidence and hospital volume data were obtained from the Hospital Discharge Register. Cementless total hip replacements had a significantly reduced risk of revision for aseptic loosening compared with cemented hip replacements. When revision for any reason was the end point in the survival analyses, there were no significant differences found between the groups. Adjusted incidence ratios of THA varied from 1.9- to 3.0-fold during the study period. Neither the average income within a region nor the morbidity index was associated with the incidence of THA. For the four categories of volume of total hip replacements performed per hospital, the length of the surgical treatment period was shorter for the highest volume group than for the lowest volume group. The odds ratio for dislocations was significantly lower in the high volume group than in the low volume group. In patients who were 55 years of age or older, the survival of cementless total hip replacements was as good as that of the cemented replacements. However, multiple wear-related revisions of the cementless cups indicate that excessive polyethylene wear was a major clinical problem with modular cementless cups. The variation in the long-term rates of survival for different cemented stems was considerable. Cementless proximal porous-coated stems were found to be a good option for elderly patients. When hip surgery was performed on with a large repertoire, the indications to perform THAs due to primary OA were tight. Socio-economic status of the patient had no apparent effect on THA rate. Specialization of hip replacements in high volume hospitals should reduce costs by significantly shortening the length of stay, and may reduce the dislocation rate.
Resumo:
There is an ongoing controversy as to which methods in total hip arthroplasty (THA) could provide young patients with best long-term results. THA is an especially demanding operation in patients with severely dysplastic hips. The optimal surgical treatment for these patients also remains controversial. The aim of this study was to evaluate the long-term survival of THA in young patients (<55 years at the time of the primary operation) on a nation-wide level, and to analyze the long-term clinical and radio-graphical outcome of uncemented THA in patients with severely dysplastic joints. Survival of 4661 primary THAs performed for primary osteoarthritis (OA), 2557 primary THAs per-formed for rheumatoid arthritis (RA), and modern uncemented THA designs performed for primary OA in young patients, were analysed from the Finnish Arthroplasty Register. A total of 68 THAs were per-formed in 56 consecutive patients with high congenital hip dislocation between 1989-1994, and 68 THAs were performed in 59 consecutive patients with severely dysplastic hips and a previous Schanz osteotomy of the femur between 1988-1995 at the Orton Orthopaedic Hospital, Helsinki, Finland. These patients underwent a detailed physical and radiographical evaluation at a mean of 12.3 years and 13.0 years postoperatively, respectively. The risk of stem revision due to aseptic loosening in young patients with primary OA was higher for cemented stems than for proximally porous-coated or HA-coated uncemented stems implanted over the 1991-2001 period. There was no difference in the risk of revision between all-poly cemented-cups and press-fit porous-coated uncemented cups implanted during the same period, when the end point was defined as any revision (including exchange of liner). All uncemented stem designs studied in young patients with primary OA had >90% survival rates at 10 years. The Biomet Bi-Metric stem had a 95% (95% CI 93-97) survival rate even at 15 years. When the end point was defined as any revision, 10 year survival rates of all uncemented cup designs except the Harris-Galante II decreased to <80%. In young patients with RA, the risk of stem revision due to aseptic loosening was higher with cemented stems than with proximally porous-coated uncemented stems. In contrast, the risk of cup revision was higher for all uncemented cup concepts than for all-poly cemented cups with any type of cup revision as the end point. The Harris hip score increased significantly (p<0.001) both in patients with high con-genital hip dislocation and in patients with severely dysplastic hips and a previous Schanz osteotomy, treated with uncemented THA. There was a negative Trendelenburg sign in 92% and in 88% of hips, respectively. There were 12 (18%) and 15 (22%) perioperative complications. The rate of survival for the CDH femoral components, with revision due to aseptic loosening as the end point, was 98% (95% CI 97-100) at 10 years in patients with high hip dislocation and 92% (95% CI, 86-99) at 14 years in patients with a previous Schanz osteotomy. The rate of survival for press-fit, porous-coated acetabular components, with revision due to aseptic loosening as the end point, was 95% (95% CI 89-100) at 10 years in patients with high hip dislocation, and 98% (95% CI 89-100) in patients with a previous Schanz osteotomy. When revision of the cup for any reason was defined as the end point, 10 year sur-vival rates declined to 88% (95% CI 81-95) and to 69% (95% CI, 56-82), respectively. For young patients with primary OA, uncemented proximally circumferentially porous- and HA-coated stems are the implants of choice. However, survival rates of modern uncemented cups are no better than that of all-poly cemented cups. Uncemented proximally circumferentially porous-coated stems and cemented all-poly cups are currently the implants of choice for young patients with RA. Uncemented THA, with placement of the cup at the level of the true acetabulum, distal advancement of the greater trochanter and femoral shortening osteotomy provided patients with high congenital hip dislocation good long-term outcomes. Most of the patients with severely dysplastic hips and a previous Schanz osteotomy can be successfully treated with the same method. However, the subtrochanteric segmental shortening with angular correction gives better leg length correction for the patients with a previous low-seated unilateral Schanz osteotomy.
Resumo:
In these lectures we plan to present a survey of certain aspects of harmonic analysis on a Heisenberg nilmanifold Gammakslash}H-n. Using Weil-Brezin-Zak transform we obtain an explicit decomposition of L-2 (Gammakslash}H-n) into irreducible subspaces invariant under the right regular representation of the Heisenberg group. We then study the Segal-Bargmann transform associated to the Laplacian on a nilmanifold and characterise the image of L-2 (GammakslashH-n) in terms of twisted Bergman and Hermite Bergman spaces.
Resumo:
A formal total synthesis of (-)-didemniserinolipid B from L-(+)-tartaric acid is presented. Key features of the synthesis include construction of the bicyclic acetal core from bisdimethyl amide of tartaric acid and further elaboration by cross metathesis.
Resumo:
Total tRNAs isolated from N2- and NH4(+)-grown Azospirillum lipoferum cells were compared with respect to amino acid acceptance, isoacceptor tRNA species levels and extent of nucleotide modifications. Amino-acylation of these two tRNA preparations with ten different amino acids indicated differences in the relative acceptor activities. Comparison of aminoacyl-tRNA patterns by RPC-5 column chromatography revealed no qualitative differences in the elution profiles. However, quantitative differences in the relative amounts of some isoacceptors were observed. These results indicate that alterations of relative amounts of functional tRNA species occur to match cellular requirements of the bacterial cells using N2 or NH4+ as nitrogen source. In addition, the content of modified nucleotides in total tRNAs of N2- and NH4(+)-grown cells was determined. In the NH4(+)-grown cells, content of most of the modified nucleotides decreased significantly. Based upon these results, the relationship of chargeability of tRNAs to base modifications is discussed.
Resumo:
Total tRNA isolated from cucumber cotyledons grown in the presence of radioactive sulfur was analyzed for the occurrence of thionucleosides. The analysis revealed the presence of at least five thionucleosides which were identified as 5-methylaminomethyl-2-thiouridine (mnm5s2U), 2-methylthio-N6-isopentenyladenosine (ms2i6A), 2-methylthio-N6-hydroxyisopentenyladenosine (ms2io6A), 5-methyl-2-thiouridine (m5s2U) and N-[(9-beta-ribofuranosyl-2- methylthiopurine-2-yl)-carbamoyl]-threonine (ms2t6A). A comparison of relative amounts of these thionucleosides in the total tRNAs of dark-, and light-grown cotyledons shows that the relative amounts of ms2i6A, ms2io6A and ms2t6A remain unchanged whereas mnm5s2U increases with a concomitant decrease in the relative amounts of m5s2U after light treatment of dark-grown cotyledons.
Resumo:
In reporting a total synthesis of erythromycin (la) we described in the preceding paper1 the synthesis of the erythronolide A seco acid derivative 2 in optically active form. In this paper we wish to report a successful transformation of 2 to 12 (synthetically equivalent to erythronolide A) via lactonization and also demonstrate that the proper functionalization of a substrate is critical for the successful lactonization.
Resumo:
In the preceding paper' we described the preparation of the key lactone intermediate la in optically active form. In this paper we report the synthesis of erythromycin (2) from la. In essence,this transformation involves the glycosidation of a suitable derivative of la with L-cladinose and D-desosamine and the generation of the C-9 ketone functionality.
Resumo:
In this paper, we present Dynamic Voltage and Frequency Managed 256 x 64 SRAM block in 65nm technology, for frequency ranging from 100MHz to 1GHz. The total energy is minimized for any operating frequency in the above range and leakage energy is minimized during standby mode. Since noise margin of SRAM cell deteriorates at low voltages, we propose Static Noise Margin improvement circuitry, which symmetrizes the SRAM cell by controlling the body bias of pull down NMOS transistor. We used a 9T SRAM cell that isolates Read and Hold Noise Margin and has less leakage. We have implemented an efficient technique of pushing address decoder into zigzag-super-cut-off in stand-by mode without affecting its performance in active mode of operation. The Read Bit Line (RBL) voltage drop is controlled and pre-charge of bit lines is done only when needed for reducing power wastage.
Resumo:
In this work, for the first time, we present a physically based analytical threshold voltage model for omega gate silicon nanowire transistor. This model is developed for long channel cylindrical body structure. The potential distribution at each and every point of the of the wire is derived with a closed form solution of two dimensional Poisson's equation, which is then used to model the threshold voltage. Proposed model can be treated as a generalized model, which is valid for both surround gate and semi-surround gate cylindrical transistors. The accuracy of proposed model is verified for different device geometry against the results obtained from three dimensional numerical device simulators and close agreement is observed.