672 resultados para Aspheric collimating lens


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The successful design of polymers for contact lens applications depends on the ability to provide a balance of properties appropriate to the ocular environment. Principal relevant aspects of the anterior eye are the tear film, eyelid and cornea, which govern the requirements for surface properties, modulus and oxygen permeability, respectively. Permeability requirements and the developing view of the needs of the cornea, in terms of oxygen consumption and the particular roles of fluorine and silicon in the design of silicone hydrogels, which have proved to be the most successful family of materials for this demanding application, are discussed. The contact lens field is complicated by the fact that contact lenses are used in a range of wear modalities, the extremes of which can conveniently be classified as lenses that are disposed of at the end of a single period of daily wear and those used for 30. days of successive day-and-night periods, frequently referred to as extended or continuous wear. As silicone hydrogels developed, in the decade following their launch there has been a progressive trend in properties taking both modulus and water content closer to those of conventional hydrogels. This is particularly evident in the family of daily disposable contact lenses that have appeared since 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to develop an instrument to measure high school students’ perspectives on global awareness and attitudes toward social issues. The research questions that guided this study were: (a) Can acceptable validity and reliability estimates be established for an instrument developed to measure high schools students' global awareness? (b) Can acceptable validity and reliability estimates be established for an instrument developed to measure high schools students' attitudes towards global social issues? (c) What is the relationship between high school students’ GPA, race/ethnicity, gender, socio-economic status, parents’ education, getting the news, reading and listening habits, the number of classes taken in the social sciences, whether they speak a second language, and have experienced living in or visiting other countries, and their perception of global awareness and attitudes toward global social issues. ^ An ex post facto research design was used and the data were collected using a 4-part Likert-type survey. It was administered to 14 schools in the Miami-Dade County, Florida area to 704 students. A factor analysis with an orthogonal varimax rotation was vii used to select the factors that best represented the three constructs – global education, global citizenship, and global workforce. This was done to establish construct validity. Cronbach’s alpha was used to determine the reliability of the instrument. Descriptive statistics and a hierarchical multiple regression were used for the demographics to establish their relationship, if any, to the findings. ^ Key findings of the study were that reliable and valid estimates can be developed for the instrument. The multiple regression analysis for model 1 and 2 accounted for a variance of 3% and 5% for self-perceptions of global awareness (factor 1). The regression model also accounted for a 5% and 13% variance in the two models for attitudes toward global social issues (factor 2). The demographics that were statistically significant were: ethnicity, gender, SES, parents’ education, listening to music, getting the news, speaking a second language, GPA, classes taken in the social sciences, and visiting other countries. An important finding for the study was those attending public schools (as opposed to private schools) had more positive attitudes towards global social issues (factor 2) The statistics indicated that these students had taken history, economics, and social studies – a curriculum infused with global perspectives.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The challenge that continues to face HRD is how to integrate real concerns for diversity into programs, practices, and research. Critical race theory was used as a lens to examine work on diversity published in Human Resource Development Quarterly (HRDQ). Eight publications were selected and analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This qualitative study used critical discourse analysis to highlight how educational stakeholders can examine discourses and react to power in texts using a feminist lens to problematize identity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated faculty library demand from an organizational culture perspective at one college where annual requests for library instruction are received from a mere six percent of faculty. Analysis of survey data revealed a statistically significant difference in academic discipline assignment of library research, with the English-Humanities faculty group far exceeding all other faculty groups including the Social Sciences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Culture, trust and prejudice may impact cross-cultural mentoring relationships among African American students attending colleges in the United States. By recognizing the cultural perceptions and differences that exist, mentors and protégés may develop a better understanding of each other’s culture so as to enhance mentoring outcomes and student success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The growth of spring break tourism in many destinations has become problematic, predominantly due to the excessive behaviour of college students. This paper examines residents’ attitudes toward spring break tourism in South Padre Island (located in Texas, USA) through the lens of community attachment. By understanding the attitudes of residents of the host communities, tourism planners and policy-makers can create policies to shape the character of tourism according to the residents’ needs. The findings suggest that, at this point in time, community residents perceive that the benefits of spring break tourism benefits exceed its’ costs. Also, the short and intense season of spring break tourism allows residents to better deal with social costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Medical Research Council (ref G0701604) and administered by the NIHR-EME (ref 09-800-26)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient’s medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods.

The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data.

The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult.

First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion factors were derived for each scanner individually, but also were derived with the combined data from the two scanners as a means to investigate the feasibility of a scanner-independent method. Using the scanner-independent method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter, most of the fitted lens dose values fell within 10-15% of the measured values from the phantom study, suggesting that this is a fairly accurate method of estimating lens dose from the CTDIvol with knowledge of the patient’s head size.

Second, the dose reduction potential of organ-based tube current modulation (OB-TCM) and its effect on the CTDIvol-to-lens dose estimation method was investigated. The lens dose was measured with MOSFET dosimeters placed within the same six anthropomorphic phantoms. The phantoms were scanned with the five clinical head CT protocols with OB-TCM enabled on the one scanner model at our institution equipped with this software. The average decrease in lens dose with OB-TCM ranged from 13.5 to 26.0%. Using the size-specific method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter for protocols with OB-TCM, the majority of the fitted lens dose values fell within 15-18% of the measured values from the phantom study.

Third, the effect of gantry angulation on lens dose was investigated by measuring the lens dose with TLDs placed within the six anthropomorphic phantoms. The 2-dimensional spatial distribution of dose within the areas of the phantoms containing the orbit was measured with radiochromic film. A method was derived to determine the CTDIvol-to-lens dose conversion factor based upon distance from the primary beam scan range to the lens. The average dose to the lens region decreased substantially for almost all the phantoms (ranging from 67 to 92%) when the orbit was exposed to scattered radiation compared to the primary beam. The effectiveness of this method to reduce lens dose is highly dependent upon the shape and size of the head, which influences whether or not the angled scan range coverage can include the entire brain volume and still avoid the orbit.

The clinical component of this dissertation involved performing retrospective patient studies in the pediatric and adult populations, and reconstructing the lens doses from head CT examinations with the methods derived in the physics component. The cumulative lens doses in the patients selected for the retrospective study ranged from 40 to 1020 mGy in the pediatric group, and 53 to 2900 mGy in the adult group.

This dissertation represents a comprehensive approach to lens of the eye dosimetry in CT imaging of the head. The collected data and derived formulas can be used in future studies on radiation-induced cataracts from repeated CT imaging of the head. Additionally, it can be used in the areas of personalized patient dose management, and protocol optimization and clinician training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As complex radiotherapy techniques become more readily-practiced, comprehensive 3D dosimetry is a growing necessity for advanced quality assurance. However, clinical implementation has been impeded by a wide variety of factors, including the expense of dedicated optical dosimeter readout tools, high operational costs, and the overall difficulty of use. To address these issues, a novel dry-tank optical CT scanner was designed for PRESAGE 3D dosimeter readout, relying on 3D printed components and omitting costly parts from preceding optical scanners. This work details the design, prototyping, and basic commissioning of the Duke Integrated-lens Optical Scanner (DIOS).

The convex scanning geometry was designed in ScanSim, an in-house Monte Carlo optical ray-tracing simulation. ScanSim parameters were used to build a 3D rendering of a convex ‘solid tank’ for optical-CT, which is capable of collimating a point light source into telecentric geometry without significant quantities of refractive-index matched fluid. The model was 3D printed, processed, and converted into a negative mold via rubber casting to produce a transparent polyurethane scanning tank. The DIOS was assembled with the solid tank, a 3W red LED light source, a computer-controlled rotation stage, and a 12-bit CCD camera. Initial optical phantom studies show negligible spatial inaccuracies in 2D projection images and 3D tomographic reconstructions. A PRESAGE 3D dose measurement for a 4-field box treatment plan from Eclipse shows 95% of voxels passing gamma analysis at 3%/3mm criteria. Gamma analysis between tomographic images of the same dosimeter in the DIOS and DLOS systems show 93.1% agreement at 5%/1mm criteria. From this initial study, the DIOS has demonstrated promise as an economically-viable optical-CT scanner. However, further improvements will be necessary to fully develop this system into an accurate and reliable tool for advanced QA.

Pre-clinical animal studies are used as a conventional means of translational research, as a midpoint between in-vitro cell studies and clinical implementation. However, modern small animal radiotherapy platforms are primitive in comparison with conventional linear accelerators. This work also investigates a series of 3D printed tools to expand the treatment capabilities of the X-RAD 225Cx orthovoltage irradiator, and applies them to a feasibility study of hippocampal avoidance in rodent whole-brain radiotherapy.

As an alternative material to lead, a novel 3D-printable tungsten-composite ABS plastic, GMASS, was tested to create precisely-shaped blocks. Film studies show virtually all primary radiation at 225 kVp can be attenuated by GMASS blocks of 0.5cm thickness. A state-of-the-art software, BlockGen, was used to create custom hippocampus-shaped blocks from medical image data, for any possible axial treatment field arrangement. A custom 3D printed bite block was developed to immobilize and position a supine rat for optimal hippocampal conformity. An immobilized rat CT with digitally-inserted blocks was imported into the SmART-Plan Monte-Carlo simulation software to determine the optimal beam arrangement. Protocols with 4 and 7 equally-spaced fields were considered as viable treatment options, featuring improved hippocampal conformity and whole-brain coverage when compared to prior lateral-opposed protocols. Custom rodent-morphic PRESAGE dosimeters were developed to accurately reflect these treatment scenarios, and a 3D dosimetry study was performed to confirm the SmART-Plan simulations. Measured doses indicate significant hippocampal sparing and moderate whole-brain coverage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proteins are specialized molecules that catalyze most of the reactions that can sustain life, and they become functional by folding into a specific 3D structure. Despite their importance, the question, "how do proteins fold?" - first pondered in in the 1930's - is still listed as one of the top unanswered scientific questions as of 2005, according to the journal Science. Answering this question would provide a foundation for understanding protein function and would enable improved drug targeting, efficient biofuel production, and stronger biomaterials. Much of what we currently know about protein folding comes from studies on small, single-domain proteins, which may be quite different from the folding of large, multidomain proteins that predominate the proteomes of all organisms.

In this thesis I will discuss my work to fill this gap in understanding by studying the unfolding and refolding of large, multidomain proteins using the powerful combination of single-molecule force-spectroscopy experiments and molecular dynamic simulations.

The three model proteins studied - Luciferase, Protein S, and Streptavidin - lend insight into the inter-domain dependence for unfolding and the subdomain stabilization of binding ligands, and ultimately provide new insight into atomistic details of the intermediate states along the folding pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[No abstract as this is a book chapter: the following represents the first 2 paragraphs.] The screen fills with close-ups of smiling African faces against a black-and-orange background: the carefree child, the gap-toothed man with smoke curling from his pipe. The faces retreat into an outline of a map of Africa as the saccharine background music dissolves into birdsong. The silhouette of an acacia tree appears. This is not the much-derided Western romantic stereotype of the continent: it is an extract from a promotional trailer on CCTV Africa, the embodiment of China’s “soft power” drive and a spearhead of Chinese state television’s overseas expansion. Yet this image is at variance with the English-language channel’s professed ambitions. The Chinese premier, Li Keqiang, himself declared that “CCTV embraces the vision of seeing Africa from an African perspective and reporting Africa from the viewpoint of Africa”. These contradictory messages prompt fundamental questions about CCTV’s expansion into Africa. Are the channel’s English-language news bulletins aimed at African or Chinese viewers? What kind of Africa – and indeed China – do they represent, and could the framing of African events by CCTV News provide an alternative to the perspective of international rivals? Is CCTV’s main mission in Africa to provide news or to act as mouthpiece of the Chinese Communist Party and state? This chapter addresses these questions by applying a cross-cultural variant of framing theory to the news content of CCTV’s Africa Live and that of its closest direct competitor, Focus on Africa from BBC World News TV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many 16th century Spanish chroniclers and missionaries, arriving at what they interpreted as a New World, saw the Devil as a “hermeneutic wildcard” that allowed them to comprehend indigenous religions. Pedro Cieza de León, a soldier in the conquest of Peru, is a case in point. Cieza considers the Devil responsible for the most aberrant religious practices and customs of the Indians, although he views the natives in a positive light, as men susceptible to divine salvation. From a providentialist perspective of the history of the conquest, Cieza interprets that the evangelization and conversion of the Indians and the implantation of Christian civilization by the Spanish Crown, were able to defeat the Devil.