891 resultados para limits of visual detection
Resumo:
The present investigation is the first part of an initiative to prepare a regional map of the natural abundance of selenium in various areas of Brazil, based on the analysis of bean and soil samples. Continuous-flow hydride generation electrothermal atomic absorption spectrometry (HG-ET AAS) with in situ trapping on an iridium-coated graphite tube has been chosen because of the high sensitivity and relative simplicity. The microwave-assisted acid digestion for bean and soil samples was tested for complete recovery of inorganic and organic selenium compounds (selenomethionine). The reduction of Se(VI) to Se(IV) was optimized in order to guarantee that there is no back-oxidation, which is of importance when digested samples are not analyzed immediately after the reduction step. The limits of detection and quantification of the method were 30 ng L(-1) Se and 101 ng L(-1) Se, respectively, corresponding to about 3 ng g(-1) and 10 ng g(-1), respectively, in the solid samples, considering a typical dilution factor of 100 for the digestion process. The results obtained for two certified food reference materials (CRM), soybean and rice, and for a soil and sediment CRM confirmed the validity of the investigated method. The selenium content found in a number of selected bean samples varied between 5.5 +/- 0.4 ng g(-1) and 1726 +/- 55 ng g(-1), and that in soil samples varied between 113 +/- 6.5 ng g(-1) and 1692 +/- 21 ng g(-1). (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Microemulsion electrokinetic capillary chromatography has been successfully applied to the separation and determination of water-soluble vitamins (thiamine hydrochloride, riboflavin, niacin, pyridoxine hydrochloride, folic acid, cobalamin, ascorbic acid) and a fat-soluble vitamin (alpha-tocopherol acetate). The optimal microemulsion buffer contained sodium dodecylsulfate (SDS) as surfactant, butan-1-ol as the co-surfactant, ethyl acetate as the oil and pH 9.2 tetraborate buffer, modified with 15% (v/v) 2-propanol. UV detection at 214 nm gave adequate sensitivity without interference from sample excipients. Under the optimized conditions, the vitamins were baseline separated in less than 7 min. Analytical curves of peak area versus concentration presented coefficients of determination (R (2) ) > 0.99, acceptable limits of quantification between 8.40 and 16.23 mu g mL(-1) were obtained. Vitamin levels in liquid formulation were quantified with intra-day precision better than 0.99% RSD for migration time and 1.19% RSD for peak area ratio. Recoveries ranged between 98.7 and 101.7%. The method was considered appropriate for rapid and routine analysis.
Resumo:
A simple and rapid development of a stability-indicating LC method for determination of chloroquine diphosphate in the presence of its hydrolysis, oxidative and photolysis degradation products is described. Stress testing showed that chloroquine diphosphate was degraded under basic conditions and by photolytic treatment but was stable under the other stress conditions investigated. Separation of the drug from its degradation products was achieved with a Nova Pack C18 column, 0.01 M PIC B7 and acetonitrile (40:60 v/v) pH 3.6, as mobile phase. Response was linear over the range 0.08-5.70 mu g mL(-1) (r = 0.996), with limits of detection and quantification (LOD and LOQ) of 0.17 and 0.35 mu g mL(-1), respectively.
Resumo:
A three-phase LPME (liquid-phase microextraction) method for the enantioselective analysis of venlafaxine (VF) metabolites (O-desmethylvenlafaxine (ODV) and N-desmethylvenlafaxine (NDV) in microsomal preparations is described for the first time. The assay involves the chiral HPLC separation of drug and metabolites using a Chiralpak AD column under normal-phase mode of elution and detection at 230 nm. The LPME procedure was optimized using multifactorial experiments and the following optimal condition was established: sample agitation at 1,750 rpm, 20 min of extraction, acetic acid 0.1 mol/L as acceptor phase, 1-octanol as organic phase and donor phase pH adjustment to 10.0. Under these conditions, the mean recoveries were 41% and 42% for (-)-(R)-ODV and (+)-(S)-ODV, respectively, and 47% and 48% for (-)-( R)-NDV and (+)-( S)-NDV, respectively. The method presented quantification limits of 200 ng/mL and it was linear over the concentration range of 200-5,000 ng/mL for all analytes. The validated method was employed to study the in vitro biotransformation of VF using rat liver microsomal fraction. The results demonstrated the enantioselective biotransformation of VF.
Resumo:
A method for simultaneous determination of seven benzodiazepines (BZPs) (flunitrazepam, clonazepam, oxazepam, lorazepam, chlordiazepoxide, nordiazepam and diazepam using N-desalkylflurazepam as internal standard) in human plasma using liquid-liquid and solid-phase extractions followed by high-performance liquid chromatography (HPLC) is described. The analytes were separated employing a LC-18 DB column (250 mm x 4.6 mm, 5 mu m) at 35 degrees C under isocratic conditions using 5 mM KH(2)PO(4) buffer solution pH 6.0: methanol: diethyl ether (55:40:5, v/v/v) as mobile phase at a flow rate of 0.8 mL min(-1). UV detection was carried out at 245 nm. Employing LLE, the best conditions were achieved with double extraction of 0.5 mL, plasma using ethyl acetate and Na(2)HPO(4) pH 9.5 for pH adjusting. Employing SPE, the best conditions were achieved with 0.5 mL plasma plus 3 mL 0.1 M borate buffer pH 9.5, which were then passed through a C18 cartridge previously conditioned, washed for 3 times with these solvents: 3 mL 0.1 M borate buffer pH 9.5,4 mL Milli-Q water and 1 mL acetonitrile 5%, finally the BZPs elution was carried with diethyl ether: n-hexane: methanol (50:30:20). In both methods the solvent was evaporated at 40 degrees C under nitrogen flow. The validation parameters obtained in LLE were linearity range of 50-1200 ng mL(-1) plasma (r >= 0.9927), limits of quantification of 50 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15%, and recovery above 65% for all BZPs. In SPE, the parameter obtained were linearity range of 30-1200 ng mL(-1) plasma (r >= 0.9900), limits of quantification of 30 ng mL(-1) plasma, within-day and between-day CV% and E% for precision and accuracy lower than 15% and recovery above 55% for all BZPs. These extracting procedures followed by HPLC analysis showed their suitable applicability in order to examine one or more BZPs in human plasma. Moreover, it could be suggested that these procedures might be employed in various analytical applications, in special for toxicological/forensic analysis. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Copaifera species (Leguminoseae) are popularly known as ""copaiba"" or ""copaiva"". The oleoresins obtained from the trunk of these species have been extensively used in folk medicine and are commercialized in Brazil as crude oil and in several pharmaceutical and cosmetic products. This work reports a complete validated method for the quantification of beta-caryophyllene, alpha-copaene, and alpha-humulene in distinct copaiba oleoresins available commercially. Thus, essential oil samples (100 mu L) were dissolved in 20 mL of hexanes containing internal standard (1,2,4,5-tetramethylbenzene, 3.0 mM) in a 25 mL glass flask. A 1 mu L aliquot was injected into the GC-FID system. A fused-silica capillary column HP-5, coated with 5% phenylmethylsiloxane was used for this study. The developed method gave a good detection response with linearity in the range of 0.10-18.74 mM. Limits of detection and quantitation variety ranged between 0.003 and 0.091 mM. beta-Caryophyllene, alpha-copaene, and alpha-humulene were recovered in a range from 74.71% to 88.31%, displaying RSD lower than 10% and relative errors between -11.69% and -25.30%. Therefore, this method could be considered as an analytical tool for the quality control of different Copaifera oil samples and its products in both cosmetic and pharmaceutical companies. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.
Resumo:
The eye lenses of Parma microlepis from the rocky barrens of Sydney (New South Wales, Australia) were found to contain Ba, Hg, Rb, and Sr at concentrations above the quantitative detection limits of solution-based inductively-coupled plasma-mass spectrometry (ICP-MS). Lenses were separated into the hard central nucleus and the softer surrounding cortex. Nuclei contained lower (equal for Ba) concentrations of these metals. Biochemical analysis of the protein composition of these lenses revealed differences in the ratio of gamma-crystallin to beta-crystallin in the lens nucleus and cortex. These changes were shown to be attributable both to protein degradation and changes in protein synthesis as fish age. Such changes may lead to the loss of sequestered metals from older cell layers, or change the affinity of new layers for particular trace metals. Differential binding affinities of these crystallins may, therefore, partially account for trace-metal differences observed in the lens nucleus and cortex.
Resumo:
Reproductive conflicts within animal societies occur when all females can potentially reproduce. In social insects, these conflicts are regulated largely by behaviour and chemical signalling. There is evidence that presence of signals, which provide direct information about the quality of the reproductive females would increase the fitness of all parties. In this study, we present an association between visual and chemical signals in the paper wasp Polistes satan. Our results showed that in nest-founding phase colonies, variation of visual signals is linked to relative fertility, while chemical signals are related to dominance status. In addition, experiments revealed that higher hierarchical positions were occupied by subordinates with distinct proportions of cuticular hydrocarbons and distinct visual marks. Therefore, these wasps present cues that convey reliable information of their reproductive status.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.
Resumo:
Purpose: To evaluate rates of visual field progression in eyes with optic disc hemorrhages and the effect of intraocular pressure (IOP) reduction on these rates. Design: Observational cohort study. Participants: The study included 510 eyes of 348 patients with glaucoma who were recruited from the Diagnostic Innovations in Glaucoma Study (DIGS) and followed for an average of 8.2 years. Methods: Eyes were followed annually with clinical examination, standard automated perimetry visual fields, and optic disc stereophotographs. The presence of optic disc hemorrhages was determined on the basis of masked evaluation of optic disc stereophotographs. Evaluation of rates of visual field change during follow-up was performed using the visual field index (VFI). Main Outcome Measures: The evaluation of the effect of optic disc hemorrhages on rates of visual field progression was performed using random coefficient models. Estimates of rates of change for individual eyes were obtained by best linear unbiased prediction (BLUP). Results: During follow-up, 97 (19%) of the eyes had at least 1 episode of disc hemorrhage. The overall rate of VFI change in eyes with hemorrhages was significantly faster than in eyes without hemorrhages (-0.88%/year vs. -0.38%/year, respectively, P < 0.001). The difference in rates of visual field loss pre- and post-hemorrhage was significantly related to the reduction of IOP in the post-hemorrhage period compared with the pre-hemorrhage period (r = -0.61; P < 0.001). Each 1 mmHg of IOP reduction was associated with a difference of 0.31%/year in the rate of VFI change. Conclusions: There was a beneficial effect of treatment in slowing rates of progressive visual field loss in eyes with optic disc hemorrhage. Further research should elucidate the reasons why some patients with hemorrhages respond well to IOP reduction and others seem to continue to progress despite a significant reduction in IOP levels. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2010; 117: 2061-2066 (C) 2010 by the American Academy of Ophthalmology.
Resumo:
Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
The spectral sensitivities of avian retinal photoreceptors are examined with respect to microspectrophotometric measurements of single cells, spectrophotometric measurements of extracted or in vitro regenerated visual pigments, and molecular genetic analyses of visual pigment opsin protein sequences. Bird species from diverse orders are compared in relation to their evolution, their habitats and the multiplicity of visual tasks they must perform. Birds have five different types of visual pigment and seven different types of photo receptor-rods, double (uneven twin) cones and four types of single cone. The spectral locations of the wavelengths of maximum absorbance (lambda (max)) of the different visual pigments, and the spectral transmittance characteristics of the intraocular spectral filters (cone oil droplets) that also determine photoreceptor spectral sensitivity, vary according to both habitat and phylogenetic relatedness. The primary influence on avian retinal design appears to be the range of wavelengths available for vision, regardless of whether that range is determined by the spectral distribution of the natural illumination or the spectral transmittance of the ocular media (cornea, aqueous humour, lens, vitreous humour). Nevertheless, other variations in spectral sensitivity exist that reflect the variability and complexity of avian visual ecology. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Quantification of stress echocardiography may overcome the training requirements and subjective nature of visual wall motion score (WMS) assessment, but quantitative approaches may be difficult to apply and require significant time for image processing. The integral of long-axis myocardial velocity is displacement, which may be represented as a color map over the left ventricular myocardium. This study was designed to explore the feasibility and accuracy of measuring long-axis myocardial displacement, derived from tissue Doppler, for the detection of coronary artery disease (CAD) during dobutamine stress echocardiography (DBE). One hundred thirty patients underwent standard DBE, including 30 patients at low risk of CAD, 30 patients with normal coronary angiography (both groups studied to define normal ranges of displacement), and 70 patients who underwent coronary angiography in whom the accuracy of normal ranges was tested. Regional myocardial displacement was obtained by analysis of color tissue Doppler apical images acquired at peak stress. Displacement was compared with WMS, and with the presence of CAD by angiography. The analysis time was 3.2 +/- 1.5 minutes per patient. Segmental displacement was correlated with wall motion (normal 7.4 +/- 3.2 mm, ischemia 5.8 +/- 4.2 mm, viability 4.6 +/- 3.0 mm, scar 4.5 +/- 3.5 mm, p <0.001). Reversal of normal base-apex displacement was an insensitive (19%) but specific (90%) marker of CAD. The sum of displacements within each vascular territory had a sensitivity and specificity of 89% and 79%, respectively, for prediction of significant CAD, compared with 86% and 78%, respectively, for WMS (p = NS). The displacements in the basal segments had a sensitivity and specificity of 83% and 78%, respectively (p = NS). Regional myocardial displacement during DBE is feasible and offers a fast and accurate method for the diagnosis of CAD. (C),2002 by Excerpta Medica, Inc.