Resumo

A graphite furnace atomic absorption spectrometric method is proposed for the direct and simultaneous determination of Cd, Cu, and Se in human blood. Samples were diluted 1:10 (v/v) in 0.5% (v/v) HNO(3) + 0.5% (v/v) Triton X-100 solution. For 12 mu L injected sample volume + 5 mu L, of 1000 mg L(-1) Pd(NO(3))(2) + 3 mu L of 1000 mg L(-1) Mg(NO(3))(2), the calculated characteristic masses (mo) were 0.9 pg Cd, 16 pg Cu, and 39 pg Se, which are close to those mo values for single-element conditions for THGA furnace (1.3 pg Cd, 17 pg Cu, and 45 pg Se). Calibration curves with linear correlations better than 0.999 were obtained. The limits of detection (LOD) were 0.03 mu g L(-1) Cd, 0.075 mu g L(-1) Cu and 0.3 mu g L(-1) Se, and the relative standard deviations (n= 12) were 2.5%, 0.3%, and 1.5%, respectively. The method was applied for Cd, Cu, and Se determination in 10 human blood samples and the results were in agreement at the 95% confidence level with those obtained by inductively coupled plasma mass spectrometry. Concentrations of analytes in the selected blood samples varied from 1.7 to 3.2 mu g L(-1) Cd, 700 to 921.7 mu g L(-1) Cu, and from 68.6 to 350 mu g L(-1) Se. The accuracy of the proposed method was also evaluated by an addition-recovery experiment and recoveries of Cd, Cu, and Se added to blood samples ranged from 99-109%, 91-103%,and 93-103%, respectively.

Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

Coordenacao de Aperfeicoamento de Pessoal de Nivel Superior (CAPES)

Identificador

ATOMIC SPECTROSCOPY, v.30, n.4, p.115-119, 2009

0195-5373

http://producao.usp.br/handle/BDPI/20221

http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000269328100001&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord

Idioma(s)

eng

Publicador

PERKIN-ELMER CORP

Relação

Atomic Spectroscopy

Direitos

closedAccess

Copyright PERKIN-ELMER CORP

Palavras-Chave #PLASMA-MASS SPECTROMETRY #WHOLE-BLOOD #ETAAS METHOD #CADMIUM #ELEMENTS #LEAD #PB #DEFICIENCY #FRACTIONS #CHROMIUM #Spectroscopy
Tipo

article

original article

publishedVersion